• Title/Summary/Keyword: Femoral fixation

Search Result 92, Processing Time 0.027 seconds

Effects of Femoral Head Anterior Glide Fixation during Active Straight Leg Raise on Hip Flexor Strength in Subjects with Femoral Anterior Glide Type

  • Su-yeon Bae;Jin-seok Lee;Eun-seop Shin;Geum-seong Myung;Kyung-joon Kang;In-Cheol Jeon
    • The Journal of Korean Physical Therapy
    • /
    • v.35 no.4
    • /
    • pp.117-123
    • /
    • 2023
  • Purpose: In this study, subjects with femoral anterior glide type were examined to investigate the effects of femoral head anterior glide fixation during active straight leg raise on the strength of the hip flexor in a supine position. Methods: Fifteen subjects participated in this study. All subjects were classified through an evaluation form for femoral anterior glide type (FAGT). The strength of the hip flexor was measured during active straight leg raise test (ASLR test), and compared with and without femoral anterior glide fixation in a supine position. The fixation of the femoral head was achieved as per the therapist's manual guidelines. Paired t-test was applied to compare changes in the strength of the hip flexor according to fixation conditions. The level of statistical significance was set at α=0.05. Results: The strength of the hip flexor was lesser during the ASLR test with fixation compared to without fixation (p=0.007). Conclusion: The strength of the hip flexor decreases with fixation. Results of this study revealed a difference between hip flexor strength, with and without femoral anterior glide fixation during ASLR, in subjects with femoral anterior glide type.

Conversion to Internal Fixation after Temporary External Fixation for Femoral Shaft Fractures in Polytrauma Patients (다발성 외상 환자의 대퇴골 간부 골절에서 임시 외고정술 후 내고정술로의 전환)

  • Choo, Suk-Kyu;Kang, Kyung-Woon;Kim, Young-Woo;Oh, Hyoung-Keun
    • Journal of Trauma and Injury
    • /
    • v.27 no.4
    • /
    • pp.151-157
    • /
    • 2014
  • Purpose: We report the surgical outcomes for femoral shaft fractures in polytrauma patients who were temporarily treated with external fixation and subsequently converted to internal fixation. Methods: From August 2008 to April 2012, we enrolled 13 patients with multiple traumas due to high-energy injuries and concurrent femoral shaft fractures in which temporary external fixation was carried out. The mean age was 39 years, with a range from 18 to 55 years. Ten were men and 3 were women. According to the AO/OTA classification of fractures, type A was found in 5 patients, type B in 6, and type C in 2, with open fractures being found in 6 patients and femoral artery rupture occurring in 2. For internal fixation, intramedullary nailing was performed in 7 patients, and minimally-invasive fixation of locking compression plates was used in 6. Results: Of the 7 patients converted to intramedullary nailing, 1 experienced delayed union. Of the 6 patients treated with minimally-invasive plate fixation, delayed union occurred in 5, and an auto-bone graft was performed within, on average, 8 months (range: 5~10 months), leading to bone union in all cases in the final follow-up. None of the patients experienced infections or complications involving other organs after having been converted to internal fixation. During the mean follow-up of 19 months, patients achieved satisfactory functional outcomes. Conclusion: In polytrauma patients with a femoral shaft fracture who have been treated with temporary external fixation and who may need internal fixation due to the occurrence of delayed union, an appropriate internal fixation method needs to be selected based on the patient's physical status, and the fracture type.

Surgical Treatment of Ipsilateral Multi-Level Femoral Fracture Treated Using Antegrade Intramedullary Nail

  • Kim, Beom-Soo;Cho, Jae-Woo;Yeo, Do-Hyun;Oh, Jong-Keon
    • Journal of Trauma and Injury
    • /
    • v.31 no.2
    • /
    • pp.96-102
    • /
    • 2018
  • Ipsilateral fractures of proximal femur with shaft and condylar region are very rare. Current concept of management is based on fixation of each fracture as independent entity using separate fixation modalities for proximal and distal parts of femur. However, we considered that antegrade femoral nailing with cephalomedullary screw fixation is a good option for ipsilateral multi-level femoral fractures. Here, we present an experience of satisfactory treatment for ipsilateral femoral neck fracture, subtrochanteric fracture, comminuted shaft fracture with supracondylar fracture following road traffic accident.

Comparative Study for Osteosynthesis of Femoral Neck Fractures: Cannulated Screws versus Femoral Neck System

  • Youngho Cho;Jae-uk Shin;Sangwoo Kim
    • Hip & pelvis
    • /
    • v.35 no.1
    • /
    • pp.47-53
    • /
    • 2023
  • Purpose: The purpose of this study is to compare the radiological results of fixation using the femoral neck system (FNS) and cannulated screw (CS) for treatment of femoral neck fractures. Materials and Methods: A retrospective study of patients with femoral neck fractures who underwent internal fixation and had follow-up of more than six months from 2010 to 2020 was conducted. A total of 87 patients were enrolled in the study. The FNS group included 20 patients and the CS group included 67 patients. Classification of fractures was performed according to Garden and Pauwels classification. Operation time, intraoperative blood loss, sliding distance of the implant, lateral soft tissue irritation caused by implants, and complications were evaluated. Results: The mean operation time was 40.30 minutes in the FNS group and 46.84 minutes in the CS group. The mean intraoperative bleeding volume was 51.25 mL in the FNS group and 72.16 mL in the CS group. Bone union was achieved in 18 patients in the FNS group (90.0%) and in 61 patients in the CS group (91.0%). The mean sliding distance of the implant was 4.06 mm in the FNS group and 3.92 mm in the CS group. No patients in the FNS group and 12 patients in the CS group complained of soft tissue irritation. Conclusion: A shorter operative time, less intraoperative bleeding, and less irritation of soft tissue were observed in the FNS group. FNS could be an alternative to CS for fixation of femoral neck fractures.

Stress Analysis of Plate Augumentation for Distal Femur Fracture (대퇴부 원위부 골절에 관한 금속판 보강술의 응력 해석)

  • 김지숙;범현규;양영수
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.816-819
    • /
    • 1997
  • The operation of femoral non-union after IM(Intramedullary) nailing in distally femoral fractures is considered. Augmentive plate fixation is the management of femoral non-union after IM nailing. The purpose of this study is to compare the bending, torsional stiffness and stress distribution of the two operations by the FEM(Finite Element Method). Augmentive plate fixation is better than IM nail fixation. These results conclude that plate augmentation is a useful method for the unstable femoral non-union after interlocking IM nailing.

  • PDF

Treatment of Femoral Neck Fractures in the Elderly: A Survey of the Korean Hip Society Surgeons

  • Hong Seok Kim;Je-Hyun Yoo;Young-Kyun Lee;Jong-Seok Park;Ye-Yeon Won
    • Hip & pelvis
    • /
    • v.35 no.3
    • /
    • pp.157-163
    • /
    • 2023
  • Purpose: This study examined the methods for treatment of femoral neck fracture (FNF) preferred by members of the Korean Hip Society (KHS) and identified factors that influence decisions regarding the surgical intervention of choice. Materials and Methods: A total of 97 members of the KHS responded to the 16-question survey which included questions about the mean number of surgeries performed each month for treatment of femoral neck fractures, the cut-off age for deciding between internal fixation and arthroplasty, the implant used most often, usage of cement, and factors influencing each decision. Results: The mean cut-off age used when deciding between internal fixation and arthroplasty was 64 years old. Hemiarthroplasty (HA) (70%) was the most preferred option for treatment of displaced FNFs in cases where arthroplasty was indicated (total hip arthroplasty [THA] 19% and dual mobility THA 11%). The main reasons for selection of arthroplasty over reduction with internal fixation were age and pre-fracture ambulatory status. Pre-trauma ambulatory status and/or sports activity were the main factors in selection of HA over THA. Cement was used by 33% of responders. Poor bone quality and a broad femoral canal were factors that influenced the usage of cement. Conclusion: Management of FNFs in the elderly is a major health problem worldwide; thus, remaining alert to current trends in treatment is essential for surgeons. The mean cut-off age used in deciding between internal fixation and arthroplasty was 64 years old. HA is the preferred method for treatment of displaced FNFs for members of the KHS.

Exchange Nailing for Aseptic Nonunion of the Femoral Shaft after Intramedullary Nailing

  • Ha, Sung-Soo;Oh, Chang-Wug;Jung, Jae-Wook;Kim, Joon-Woo;Park, Kyeong-Hyeon;Kim, Seong-Min
    • Journal of Trauma and Injury
    • /
    • v.33 no.2
    • /
    • pp.104-111
    • /
    • 2020
  • Purpose: Although exchange nailing is a standard method of treating femoral shaft nonunion, various rates of healing, ranging from 72% to 100%, have been reported. The purpose of this study was to evaluate the efficacy of exchange nailing in femoral shaft nonunion. Methods: We retrospectively reviewed 30 cases of aseptic femoral shaft nonunion after intramedullary nailing. The mean postsurgical period of nonunion was 66.8 weeks. A nail at least 2 mm larger in diameter was selected to replace the previous nail after reaming. Distal fixation was performed using at least two interlocking screws. The success of the procedure was determined by the finding of union on simple radiographs. Possible reasons for failure were analyzed, including the location of nonunion, the type of nonunion, and the number of screws used for distal fixation. Results: Of the 30 cases, 27 achieved primary healing with the technique of exchange nailing. The average time to achieve union was 23.1 weeks (range, 13.7-36.9 weeks). The three failures involved nonunion at the isthmic level (three of 15 cases), not at the infraisthmic level (zero of 15 cases). Of eight cases of oligotrophic nonunion, two (25%) failed to heal, and of 22 cases of hypertrophic nonunion, one (4.5%) failed to heal. Of 11 cases involving two screws at the distal fixation, two (18.2%) failed to heal, and of 19 cases involving three or more screws, one (5.3%) failed to heal. None of these findings was statistically significant. Conclusions: Exchange nailing may enable successful healing in cases of aseptic nonunion of the femoral shaft. Although nonunion at the isthmic level, oligotrophic nonunion, and weaker distal fixation seemed to be associated with a higher chance of failure, further study is needed to confirm those findings.

Postoperative Valgus Deformity and Progression of Ostheoarthritis in Non-Displaced Femoral Neck Fractures

  • Hyungtae Kim;Ji Su Kim;Yerl Bo Sung
    • Hip & pelvis
    • /
    • v.35 no.4
    • /
    • pp.259-267
    • /
    • 2023
  • Purpose: Nondisplaced femoral neck fractures have traditionally been treated with in situ fixation. However, poor surgical and clinical outcomes have been reported for fractures with valgus deformity >15°, and the reduction of valgus impaction has recently been emphasized. In addition, early degenerative osteoarthritis can be caused by cam-type femoroacetabular impingement after healing of femoral neck fractures. This study was designed with the objective of confirming the difference in progression of radiographic osteoarthritis according to the severity of the valgus deformity. Materials and Methods: Patients who underwent internal fixation using multiple cannulateld screws for management of nondisplaced femoral neck fractures were divided into two groups: high valgus group (postoperative valgus angle ≥15°) and low valgus group (postoperative valgus angle <15°). Evaluation of demographic data and changes in the joint space width from the immediate postoperative period to the latest follow-up was performed. Results: A significant decrease in joint space width in both hip joints was observed in the high valgus group when compared with the low valgus group, including cases with an initial valgus angle less than 15° and those corrected to less than 15° of valgus by reduction. No complications requiring surgical treatment were observed in either group; however, two cases of avascular necrosis, one in each group, which developed in the low valgus group after reduction of the fracture, were followed for observation. Conclusion: Performing in situ fixation in cases involving a valgus deformity ≥15° in non-displaced femoral neck fractures may cause accelerated narrowing of the hip joint space.

Surgical Treatment of the Atypical Femoral Fracture: Overcoming Femoral Bowing

  • Lee, Kyung-Jae;Min, Byung-Woo
    • Hip & pelvis
    • /
    • v.30 no.4
    • /
    • pp.202-209
    • /
    • 2018
  • Atypical femoral fractures differ from ordinary femoral diaphyseal or subtrochanteric fractures in several aspects. Although several authors have reported the results of surgical treatment for atypical femoral fractures, the rate of complications (e.g., delayed union, nonunion, fixation failure, and reoperation) is still high. Therefore, we reviewed principles of surgical treatment and describe useful methods for overcoming femoral bowing in these high-risk patients.

Comparison of Primary Stability of Different Femoral Fixation Techniques in Anterior Cruciate Ligament Reconstruction (전 십자 인대 재건술에서 대퇴골측 고정 방법의 초기 안정성의 비교)

  • Song, Eun-Kyoo;Lee, Keun-Bae;Lee, Moon
    • Journal of the Korean Arthroscopy Society
    • /
    • v.2 no.1
    • /
    • pp.85-92
    • /
    • 1998
  • Various methods for fixation of graft have been widely used for reconstruction of anterior cruciate ligament. However, the biomechanical strength of each fixation techniques are not fully understood. The purpose of this study is to compare the pull out strength of different fixation techniques which is probably the most important factor for the success at the initial stage of healing. Biomechanical test was carried out to measure and compare the pull out tensile strength of five different fixation techniques in 35 pig(Yorkshire) knees. ANOVA and Duncan multiple comparison test was applied for statistical analysis. In the two fixation techniques with bone patellar tendon bone graft, the mean maximum tensile strength was $1333.4{\pm}148.5N$ with titanium interference screw, while it was $1310.1{\pm}168.9N$ with biodegradable interference screw. The failure mode were pulled out of bone plugs from the femoral tunnel in majority cases. In the fixations with hamstring tendon, the mean maximum tensile strength were $1405.9{\pm}135.1N$ with SemiFix screw, $820.3{\pm}104.5N$ with biodegradable interference screw, and $682.1{\pm}54.2N$ with Endobutton. The mode of failure was variable in each technique. The tendon was pulled out from the tunnel in biodegradable interference screw fixation, the screw was bent in the SemiFix system, and the polyester tape were ruptured or the buttons were pulled into tunnel in Endobutton fixation. The mean maximum tensile strength of two interference screws with bone patellar tendon bone was statistically comparable to that of SemiFix with hamstring tendon. However biodegradable interference screw and Endobutton with hamstring tendon showed weaker maximum tensile strength than above three fixation techniques (P<0.05).

  • PDF