• Title/Summary/Keyword: Feeding Unit Design

Search Result 82, Processing Time 0.033 seconds

Development and Application of a Feeding Program for Infants Postoperatively following Cardiac Surgery (심장수술 받은 영아의 영양중재프로그램 개발 및 적용)

  • Moon, Ju-Ryoung;Cho, Yong Ae;Min, Sun-In;Yang, Ji-Hyuk;Huh, June;Jung, Yeon-Yi
    • Journal of Korean Academy of Nursing
    • /
    • v.39 no.4
    • /
    • pp.508-517
    • /
    • 2009
  • Purpose: Despite recent advances in the surgical and postoperative management of infants with congenital heart disease, nutritional support for this population is often suboptimal. The purpose of this study was to develop a nutritional program for the postoperative period for infants who have had cardiac surgery and to evaluate effects of the program. Methods: A quasi-experimental design with pretest and posttest measures was used. A newly developed nutritional program including a feeding protocol and feeding flow was provided to the study group (n=19) and usual feeding care to the control group (n=19). The effects of the feeding program were analyzed in terms of total feed intake, total calorie intake, gastric residual volume, and frequency of diarrhea. Results: Calorie intake and feeding amount in the study group were significantly increased compared to the control group. However, the two groups showed no significant differences in gastric residual volume and frequency of diarrhea. Conclusion: The results indicate that the nutritional program used in the study is an effective nursing intervention program in increasing feeding amount and calorie intake in infants postoperative to cardiac surgery and does not cause feeding-related complications.

A development of double-moving system for composite die using multi-axis shuttle unit in the sheet metal forming (판재성형 가공에서의 다축 단동 유닛을 이용한 복합금형용 Double-moving System 개발)

  • Kim, Dong-wook;Choi, Kyu-Kwang
    • Design & Manufacturing
    • /
    • v.10 no.2
    • /
    • pp.39-43
    • /
    • 2016
  • Most of automobile parts manufactured through sheet metal forming are mass-produced by using press mold. In recent years, automation and speeding up of press lines have been expanding to maximize product productivity using a press die. The proportion of the moving time in the press line is high, and therefore requires high-speed and automated equipment for the moving process. In this paper, to provide the double-moving system can be the moving time reduction and increased productivity. Developed transport system consists of the material supply, the material feeding device and the PLC controller and the devices are positioned between each of the pressing process. In this paper, the double-moving system including developed units using a multi-axial single-acting through this reduced the C/T(cycle time) and improved the productivity.

Cleaning Model of Head-feeding Combine (자탈형 콤바인의 선별모델)

  • Kim, S.H.;Kang, W.S.;Gregory, James M.
    • Journal of Biosystems Engineering
    • /
    • v.19 no.1
    • /
    • pp.22-32
    • /
    • 1994
  • The combine harvester is considered as an important but complicated and costly machine. The appropriate size of combine has to be developed to use efficiently in Korea. But the combine is such a complicated machine that a complete design model to develop a new type is impossible without understanding the relationship between each factor. The combine capacity is generally limited by the cleaning shoe performance. So a design model for a cleaning shoe has to be developed first for the complete combine design. The objective of this research was to develop a cleaning model of head-feeding combine to predict grain separation from chaff and broken straw on a sieve. A developed physically based model can explain the situation which can happen during separation process. A test apparatus based on the field going machine was developed. The test materials were paddy rice and barley. The data obtained were analyzed by the hand and the video camera. The developed model was verified as an adequate model through the test with $R^2$ of 0.934 and 0.837. The model can be used to evaluate design and operation alternatives of combine and also applied to the automatic control of separation unit of combine with a loss monitering sensors.

  • PDF

Reliability prediction of Centerless grinding machine (무심연삭 시스템의 신뢰성 예측)

  • Choi, H.Z.;Lee, S.W.;Kim, G.H.;ChoI, Y.J.
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1105-1108
    • /
    • 2004
  • As recently optical communication industry is developed, request of optical communication part is increased. Ferrule is very important part which determines transmission efficiency and quality of information in the optical communication part. Most of ferrule processes are grinding which request high processing precision. The ultra precision centerless grinding machine for ferrule grinding was designed. The centerless grinding machine is composed of the high damping bed, grinding wheel spindle unit, regulating wheel spindle unit, feeding table and dressing unit. Reliability prediction was very important for the high quality design. In this study, centerless grinding machine was predicted reliability.

  • PDF

Nutritional Support, Gastric Residual Volume and Nutritional Status during Enteral Nutrition in Intensive Care Unit Patients (중환자실 경장영양 환자의 영양지원, 위 잔여량 및 영양상태)

  • Lee, Minju;Kang, Jiyeon
    • Korean Journal of Adult Nursing
    • /
    • v.26 no.6
    • /
    • pp.621-629
    • /
    • 2014
  • Purpose: The purpose of this study was to investigate the nutritional support, gastric residual volume, and nutritional status of the intensive care unit (ICU) patients on enteral feeding. Methods: A descriptive longitudinal design was used to collect 5 day data on enteral nutrition of 52 ICU patients in an university hospital. Nutritional support was calculated with actual caloric intake compared to individual caloric requirement. Residual volumes were measured prior to routine feedings, and the serum albumin levels and the total lymphocyte counts were checked to evaluate nutritional status. The data were analyzed using one group repeated measures ANOVA, paired t-test, and Spearman's bivariate correlation analysis. Results: The subjects received their first enteral feeding on the $5.75^{th}$ day of ICU admission. The mean nutritional support rate was 49.1% of the requirement, however prescription rate and support rate were increased as time goes by. Gastric residual volumes were less than 10 cc in 95% cases. A significant negative correlation was found between nutritional support and nutritional status. Conclusion: The nutritional support for ICU patient was low compared to the requirement, and their nutritional status was worse than at the time of ICU admission. Further studies are necessary to develop nursing interventions for improving nutritional support for ICU patients.

Domestic Development of Vibrational Film Forming Machine and Die in the High Speed Production(II) - Multi-production forming machine - (고속 생산형 필름 진동판 성형기 및 금형 국산화 개발(II) - 다량 생산 진동판 성형기 -)

  • Kim, Jungl-Hyun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.13 no.1
    • /
    • pp.52-58
    • /
    • 2014
  • This study consists of two parts. The first discusses the development of a single production forming machine which was reported in earlier papers. The second outlines the development of a multi-production forming machine, which consists primarily of a film feeding unit, an unwinding unit, and a heating block unit. The heating block unit of the multi-production forming machine has 30 members per die. An analysis of the stress deformation and temperature deviation of this machine is carried out using ANSYS Workbench and CFX-11 under the design conditions. According to this analysis, the maximum deflection in the Z-direction is $0.05104{\mu}m$ and the maximum temperature deviation is $0.7^{\circ}C$ when the temperature of the heating block unit is $175^{\circ}C$. It was also found that these values are structurally safe. The advantage of the developed multi-production forming machine is demonstrated to be in its offering of a proper voice test.

A comparison of nursing effects after the improvement of nasogastric tube feeding method (비위관 영양방법 개선에 따른 간호효과 비교)

  • Choi, Ja-Yun;Jang, Keum-Seong;Hwang, Seon-Young
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.8 no.4
    • /
    • pp.645-654
    • /
    • 2002
  • Purposes : This study was conducted to examine nursing effects after using a new method of nasogastric tube feeding with recycled PETE bottle making use of gravity, and to compare with those of bolus method using syringe and pressure. Methods : The data collected from patients with nasogastric tube feeding more than a week at an internal medicine unit of C university hospital located in G-city from January 1st, 1998 through June 30th, 2000. For this nonequivalent control group posttest non-synchronized design, 28 patients were assigned to an experimental group and 35 patients to a control group. The homogeneity of two groups and the dependent variables were tested with use of $x^2-test$ and t-test. Results : The duration of hemostatic use was significantly shorter in the experimental group than control group(t=2.63, p=0.02). Also, the patients with PETE bottle feeding had a lower cost of material(t=3.51, p=0.01) and a lower rate of the time of direct nursing care(t=2.44, p=0.04) than those of control group. But, there was no significant difference between two groups in the length of hospital stay. Conclusion : This results indicates that nasogastric tube feeding with PETE bottle is superior to nasogastric tube feeding with syringe. This findings gave us an evidence to enhance nursing effectiveness in clinical setting.

  • PDF

Deformation and stress analysis of Vertical form-fill-seal machine (파우치 포장 장비의 변형량 및 응력해석)

  • Baek, Seung-Yub;Choi, Seung-Geon;Jung, Yeon-Seung;Jang, Young-Ju
    • Design & Manufacturing
    • /
    • v.10 no.1
    • /
    • pp.46-50
    • /
    • 2016
  • Beverage industry is the largest in the domestic packaging market. Usually, beverage is packed in palstic, glass, can and paper bags. However, the cost of these packaging methods are very high and the recycling are not easy to handle. Pouch packaging method is one of the packaging method to solve the drawbacks of former beverage containers. The pouch packaging methods are difficult to control, it requires a number of processes. A vertical form-fill-seal machine which is self-developed is the capable of processing in a single apparatus. In this paper, in order to develop a pouch equipment, the structure analysis was carried out for the main unit. The stress and deformation of feed unit which removes the air inside the pouch while feeding down has been analyzed. It receives the greatest impact from the rolling part. And also, the sealing unit has been analyzed. The analysis result shows that the stress and the deformation was slight to be applicable to the actual system.

Effects of Feeding Patterns and Sexes on Growth Rate, Carcass Trait and Grade in Korean Native Cattle

  • Choi, B.H.;Ahn, B.J.;Kook, K.;Sun, S.S.;Myung, K.H.;Moon, S.J.;Kim, J.H.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.15 no.6
    • /
    • pp.838-843
    • /
    • 2002
  • The objectives of this study were to examine growth performance and meat quality by three different feeding patterns in Korean native cattle (KNC). In each of 3 years, fifteen KNC were randomly assigned in a (3 feeding management)${\times}$(3 sex) factorial design experiment; thus, in total, there were 5 animals in each of the 9 treatments. The three feeding management treatments were longterm (24 month) restriction feeding (LTFR), long-term restriction feeding-hormone implant (LTFR-tH), and short-term (18 month) nonrestriction feeding (STFNR). Three sexes were bull, steer, and heifer. Concentrate diet was fed restriction-feeding method based on body weight in LTFR and LTFR-tH. However, the diet was fed ad libitum in STFNR. Hormonal implantation was made three times with M-$PO^{TM}$ for bulls and with F-$TO^{TM}$ for heifers at 18, 20, 22 month of age in LTFR-tH. Animal were purchased from the local cattle market and managed in two local farms and at the university research unit. Animals were slaughtered at 24 months for long-term trial and at 18 month for short-term trial. The growth rate was the highest in bulls and the lowest in heifers. However, the differences were diminished in F-$TO^{TM}$ implanted heifers. The average daily gain was high in STFNR due to ad libitum feeding. The carcass grade was similar among the treatments on percentage bases. Hormonal implants improved significantly the meat quality grade in all sexes. Castration increased body fat content and improved meat quality grade by intramuscular fat deposition. In conclusion, long-term feeding and hormone treatment increased meat quality grade more than short-term feeding. However, ADG was higher in the short-term trial although feedefficiency was lower.

Development and Effect of the Feeding Protocol for Preterm Infants (미숙아의 수유 프로토콜 개발 및 적용)

  • Lee, Jae-Young;Son, Hyun-Mi;Park, Kyung-Hee
    • Child Health Nursing Research
    • /
    • v.20 no.1
    • /
    • pp.20-29
    • /
    • 2014
  • Purpose: The purpose of this study was to develop a feeding protocol for premature infants and to evaluate the effects of protocol. Methods: The feeding protocol was developed through a literature review and discussions of an expert group. The developed feeding protocol was tested with 85 preterm infants in one neonatal intensive care unit in B city. A non-equivalent control group non-synchronized design was used. Data were collected from January 1 to April 30, 2013 for the control group and from June 1 to September 30, 2013 for the experimental group. The experimental group (n=38) received the feeding protocol, whereas the control group (n=47) had routine feeding care. Collected data were analyzed by t-test and -test using SPSS/WIN version 18.0. Results: First feeding time (t=2.22, p=.029) and full enteral feeding time (t=2.28, p=.026) were significantly decreased in the experimental group compared to the control group. There was no difference in incidence of complications (p>.05). Also no significant differences in weight reduction rate between the two groups were observed at the 7th postnatal day (t=-1.23, p=.222). Conclusion: The results indicate that the feeding protocol for preterm infants is effective in decreasing first feeding time and full enteral feeding time.