• Title/Summary/Keyword: Feeding Point

Search Result 242, Processing Time 0.027 seconds

A Study of Flexible T-DMB Antenna Using Rectangular Stub and Matching Circuit (매칭 회로와 구형 Stub를 이용한 Flexible T-DMB 안테나 구현에 관한 연구)

  • Kim, Ho-Jin;Lee, Seon-Hyeon;Lee, Young-Hun;Lee, Sang-Seok
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.2
    • /
    • pp.236-244
    • /
    • 2011
  • In this paper, we proposed flexible T-DMB dipole-shaped antenna that has strength of glass antenna and also has portability and ease of production. The input impedance of antenna according to vehicle body-effect was considered in order to install the antenna on the top of the front window. Installation position of on-glass antennas are changeable defends on driver, so we proposed Interdigital capacitor in feeding point to achieve matching characteristic with no position limit. The measurement result showed good return loss characteristic-below -6 dB in the T-DMB frequency band and maintained fixed resonant frequency.

Frequency-Dependent Grounding Impedances of Counterpoises Associated with Soil Resistivity (대지저항률에 따른 매설지선의 접지임피던스의 주파수의존성)

  • Kim, Tae-Ki;Choi, Young-Chul;Choi, Jong-Hyuk;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.5
    • /
    • pp.114-121
    • /
    • 2010
  • This paper deals with the frequency-dependent grounding impedances of counterpoises relevant to the soil resistivity, the length of counterpoises and the feeding point of test current. The grounding impedances of counterpoises buried in one-layered and two-layered soils were measured and analyzed in the frequency range from 1[kHz] to 10[MHz]. As a result, the frequency-dependent grounding impedances strongly depend on the soil resistivity, and the grounding impedances within the frequency of several tens [kHz] are capacitive behavior in high soil resistivity. When injecting the ground current to the end of counterpoise buried in soil with high resistivity, the grounding impedances in high frequency are increased.

Design of Wideband Circular polarized Patch Antenna for 1.6GHz band (1.6GHz대역용 광대역 원편파 패치 안테나 설계)

  • Kim, GunKyun;Rhee, Seung-Yeop;Yeo, Junho;Lee, Jong-Ig;Kang, NyoungHak
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.05a
    • /
    • pp.61-62
    • /
    • 2017
  • In this study, a circular polarization patch antenna operates at the wide bandwidth of 1.5GHz~1.7GHz was designed. To obtain the wide bandwidth and high gain, the high air substrate was applied. The impedance bandwidth is improved by adjusting the sizes of patch, the distance between main patch and ground plate, the length of internal slots, the position of feeding point, the length of external stub, etc. The antenna is designed by simulation for an operation in the frequency range of 1.5GHz~1.7GHz band, and the antenna characteristics such as return loss, gain, radiation patterns are examined.

  • PDF

A New Waveshaper for Harmonic Mitigation in Vector Controlled Induction Motor Drives

  • Singh, Bhim;Garg, Vipin;Bhuvaneshwari, G.
    • Journal of Electrical Engineering and Technology
    • /
    • v.3 no.2
    • /
    • pp.152-161
    • /
    • 2008
  • This paper deals with a new wave shaping technique for cost effective harmonic mitigation in ac-dc converter feeding Vector Controlled Induction Motor Drives(VCIMD's) for improving power quality at the point of common coupling(PCC). The proposed harmonic mitigator consists of a polygon connected autotransformer based twelve-pulse ac-dc converter and a small rating passive shunt filter tuned for $11^{th}$ harmonic frequency. This ac-dc converter eliminates the most dominant $5^{th},\;7^{th},\;and\;11^{th}$ harmonics and imposes the reduction of other higher order harmonics from the ac main current, thereby improving the power quality at ac mains. The design of autotransformer is carried out for the proposed ac-dc converter to make it suitable for retrofit applications, where presently a 6-pulse ac-dc converter is used. The effect of load variation on VCIMD is also studied to demonstrate the effectiveness of the proposed ac-dc converter in a wide operating range of the drive. Experimental results obtained on the developed laboratory prototype of the proposed harmonic mitigator are used to validate the model and design of the ac-dc converter.

The Effects of the Arc Pressure Variation on the Penetration by the filler Wire Feed Rate in Pulsed TIG Welding (펄스 TIG용접에서 필러 와이어 송급속도에 따른 아크압력 변동이 용입에 미치는 영향)

  • 조상명;김진우
    • Journal of Welding and Joining
    • /
    • v.22 no.1
    • /
    • pp.71-76
    • /
    • 2004
  • In the standpoint of the arc pressure, the effects of the filler wire feed rate on the penetration was investigated in this study. The pure Ar gas was used as a shield gas and the parameters investigated were the welding current and the filler wire feed rate. By making the experiment on the arc pressure, we could know that the arc pressure was fluctuated as the depth-into-arc of the tungsten rod. Instead of the filler wire, the tungsten rod was supplied into the molten pool to make this experiment. Because the filler wire melted in arc and then we couldn't measure the arc pressure. So, the tungsten rod - the highest melting point - was used. According to the depth-into-arc of the tungsten rod, the arc pressure could be measured by using the manometer. It was proved that the arc pressure got higher as the wire feed rate was slow. It is reported the arc pressure is proportion to welding voltage and the square of welding current. But, in the filler wire TIG welding, we could blow that arc pressure was fluctuated as the depth-into-arc of filler wire was changed. We could measure the arc pressure by the variation of the filler wire feed rate and could verify that it affected bead shape and penetration.

Property of Water Environment and Evaluation of Zooplankton as Predators for the Control of Algal Bloom in the Agricultural Reservoir (농업용저수지의 녹조제어를 위한 수환경 특성과 포식성 천적생물의 분리 및 효과분석)

  • Nam, Gui-Sook;Song, Young-Hee;Lee, Eui-Haeng;Hong, Dae-Byuk;Han, Myung-Soo
    • KCID journal
    • /
    • v.18 no.1
    • /
    • pp.33-43
    • /
    • 2011
  • Jundae reservoir has basin area of 234ha, average depth of 3.77m and total storage of $619{\times}10^3m^3$, and is located in Dangin-gun, Chungcheongnam-do. The water quality of Jundae reservoir exceeded the IV grade of water quality standard as available for irrigation water in COD, TN, TP, Chl-a. COD and Chl-a were higher in spring season, because the algal bloom by phytoplankton increased. And the algal blooms in October by inflow non-point pollution during summer rainy season. The most dominant zooplankton was rotifers during study period at all stations. Dominant species were Keratella cochlearis, Polyarthra spp., and Trichocerca spp. We successfully established 2 isolated clone cultures as predator. One is Rotifer, Euchlanis sp. and another is cladocerans, Bosmina sp. To test the removal rate of 2 cultures against Microcystis aeruginosa, we inoculated Euchlanis sp. and Bosmina sp. separately when the abundance reached at $1.0{\times}10^6$cells/ml. Euchlanis sp. removed M. aeruginosa around 98.9% and Bosmina sp. removed it around 98.4%. They are useful grazers for controling algae blooms, Euchlanis sp. and Bosmina sp. feeding on M. aeruginosa highly.

  • PDF

Development and Utilization of Guidelines for Customized Hygiene Management of Children's Meal Facilities (어린이 급식시설 맞춤형 위생관리 지도서의 개발과 활용)

  • Choi, Kyunga;Lee, Sunghyun;Park, Hyekyung
    • Journal of the FoodService Safety
    • /
    • v.2 no.1
    • /
    • pp.36-43
    • /
    • 2021
  • The development of food poisoning prevention guidelines aims to prevent food poisoning in advance and improve the safety of children's meals through hygiene management of children's feeding facilities, especially infants' facilities. Therefore, the composition of the content should be designed so that it can be fully understood from the point of view of the layperson. In terms of meal service management, various standards must be fully reflected and reviewed to increase utilization in the field. Daycare centers and kindergartens have different administrative agencies, similar application laws and guidelines, but different parts exist and various types of facilities, so management standards are often ambiguous. Therefore, such management requires easy guidance, not special guidance, and it should be universally applicable to any facility. Prior studies have shown that the management of meal facilities is the most efficient, but it is difficult to hire and deploy specialists due to the operation of children's meal facilities, so guidance, facilities managers and workers need to voluntarily practice them. It is time to prepare hygiene guidelines that reflect the characteristics of these children's cafeterias, and it is necessary to prepare and utilize guidance suitable for reality until it is institutionalized for the deployment of manpower exclusively for meals.

New Backstepping-DSOGI hybrid control applied to a Smart-Grid Photovoltaic System

  • Nebili, Salim;Benabdallah, Ibrahim;Adnene, Cherif
    • International Journal of Computer Science & Network Security
    • /
    • v.22 no.4
    • /
    • pp.1-12
    • /
    • 2022
  • In order to overcome the power fluctuation issues in photovoltaic (PV) smart grid-connected systems and the inverter nonlinearity model problem, an adaptive backstepping command-filter and a double second order generalized Integrators (DSOGI) controller are designed in order to tune the AC current and the DC-link voltage from the DC side. Firstly, we propose to present the filter mathematical model throughout the PV system, at that juncture the backstepping control law is applied in order to control it, Moreover the command filter is bounded to the controller aiming to exclude the backstepping controller differential increase. Additionally, The adaptive law uses Lyapunov stability criterion. Its task is to estimate the uncertain parameters in the smart grid-connected inverter. A DSOGI is added to stabilize the grid currents and eliminate undesirable harmonics meanwhile feeding maximum power generated from PV to the point of common coupling (PCC). Then, guaranteeing a dynamic effective response even under very unbalanced loads and/or intermittent climate changes. Finally, the simulation results will be established using MATLAB/SIMULINK proving that the presented approach can control surely the smart grid-connected system.

A mark-release-recapture experiment with Anopheles sinensis in the northern part of Gyeonggi-do, Korea

  • Cho, Shin-Hyeong;Lee, Hyeong-Woo;Shin, E-Hyun;Lee, Hee-Il;Lee, Wook-Gyo;Kim, Chong-Han;Kim, Jong-Taek;Lee, Jong-soo;Lee, Won-Ja;Jong, Gi-Gon;Kim, Tong-Soo
    • Parasites, Hosts and Diseases
    • /
    • v.40 no.3
    • /
    • pp.139-148
    • /
    • 2002
  • In order to study the range of flight and feeding activity of Anopheles sinensis, the dispersal experiment was conducted in Paju city, located in the northern part of Gyeonggi-do, Republic of Korea, during the period of 7th to 28th September 1998. Unfed females An. sinensis were collected in cowshed and released after being marked with fluorescent dye at 23:00 hours on the same day. Released female mosquitoes were recaptured everyday during 21 days using light traps, which were set at 10 sites in the cowsheds located 1, 3, 6, 9 and 12 km north-northwest and north-northeast and at 3 sites located 1, 6 and 9 km toward south-west from the release point. In addition, to study the longest flight distance in one night, we set the light traps at 16 and 20 km toward north-northeast from the release site. All the collected mosquitoes were placed on filter papers and observed on UV transilluminator after treatment with one drop of 100% ethanol. Out of 12,773 females of An. sinensis released, 194 marked females mosquitoes were recaptured, giving 1.52% recapture rate. Of 194, 72 mosquitoes (37 1%) were recaptured in light traps from three places set at 1 km from the release point, 57 mosquitoes (29.4%) from two places at 1-3 km, 41 mosquitoes (21.1%) from three places at 3-6 km, 20 mosquitoes (10.3%) from three places at 6-9 km, and 4 mosquitoes (2.1%) from two places at 9-12 km. Since 170 female mosquitoes (87.6%) out of 194 marked mosquitoes were captured within 6 km from the release point, this flight radius represents the main activity area. An. sinensis was found to be able to fly at least 12 km during one night.

Anatomic Analysis of Rectus Femoris Functional Flap in Korean (대퇴직근 기능성 유리 피판술을 위한 신경 및 혈관에 대한 해부학적 고찰)

  • Han, Kyoung-Jin;Lee, Young-Kil;Kim, Joon-Yong;Han, Seung-Hwan;Lee, Du-Hyoung;Cho, Jae-Ho
    • Archives of Reconstructive Microsurgery
    • /
    • v.16 no.1
    • /
    • pp.1-5
    • /
    • 2007
  • The purpose of this article to evaluate the availability of the rectus femoris flap in Korean subjects. Material and Methods is that Cadaveric dissections were done on 51 femoral triangles of 26 cadevers. We measured the length of the direct head of rectus femoris from anterior superior iliac spine to patella upper pole, ASIS to lateral border of femoral nerve, and entry point of femoral nerve and vessel branches to rectus. Usually, there were three terminal branches to rectus femoris from the femoral nerve. The entry point of the first branch was at the proximal $17.5{\sim}31.4%$ portion of the rectus femoris. The second and the third branch entered at the proximal $22.5{\sim}40.7%$ and $26.3{\sim}42.3%$, respectively. The vessel entry was at $20.2{\sim}37.3%$. The length from ASIS to femoral nerve was $3.5{\sim}8.5\;cm$. Among the 51 rectus femoris muscles, 44 had one nutrient artery, and 7 had 2 nutrient arteries. The nutrient artery originated from the descending branch of the lateral femoral circumflex artery in 18(40.9%) cases, directly from the lateral femoral circumflex artery in 8(18.0%) cases, and from proximal(6 cases, 13.6%) and distal(12 cases, 27.3%) portion of the deep femoral artery. The average length of the nutrient artery was 29.8 mm and the width was 2.14 mm. The point where it meets the main feeding artery of the rectus femoris was $9.0{\sim}15.0\;cm$ from the ASIS. In all cases, the main artery's entrance was proximal to the first nerve branch. Conclusion is that rectus femoris has available data for functional flap.

  • PDF