• Title/Summary/Keyword: Feeding Line

Search Result 426, Processing Time 0.037 seconds

Evaluation of the variable TAB Autotransformer for ascending collecting Voltage (집전전압 향상을 위한 가변탭 단권변압기 검토)

  • Lee, Chang-Mu;Han, Moon-Seub;Lee, Han-Min
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.1426-1430
    • /
    • 2009
  • AC AT feeding method consists return circuits of electric train inserting in parallel between trolly line and feeding line and connecting neutral line to rail and FPW. Due to increasing electric load at feeding system, collecting voltage of train and end voltage are going down. So to increase voltage between trolly line and rail, the usefulness of new autotransformer are considered which variation of short impedance and change of line voltage is simulated with modified winding ratio of autotransformer from 1:1 to variable tab.

  • PDF

The Concept Design of Joint Part Between Propellant Tank and Feeding Line for Launch Vehicle (발사체 추진제 탱크와 배관 연결부 개념설계)

  • Jung, Dong-Ho;Cho, Kie-Joo;Oh, Seung-Hyub
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.801-804
    • /
    • 2011
  • The concept design of joint part between propellant tank and feeding line for launch vehicle has been performed with the case study of oversea launch vehicles. we carried out, for the several configurations, numerical flow analyses to find the joint configuration which promises high flow uniformity at the outlet. There were a little difference in the numerical results, because the length of feeding lines are sufficiently long to stabilize the flow field.

  • PDF

Acoustic Effect of an Orifice on Suppression of Pressure Oscillation in a Fluid Feeding Line (유체 공급 배관내 압력진동 감쇠에 미치는 오리피스의 음향학적 효과)

  • Son, Chae-Hun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.34 no.4
    • /
    • pp.11-16
    • /
    • 2006
  • Effects of an orifice on suppression of pressure oscillation in a fluid feeding line are investigated numerically through the installation of an orifice inside the feeding line. Based on linear acoustic theory, acoustic-damping effect of an orifice is emphasized in this study. When an orifice is installed at the node of pressure oscillation corresponding to the anti-node of velocity oscillation, damping capacity is maximized. On the other hand, the orifice installed at the anti-node of pressure oscillation has little damping capacity. As the blockage ratio and thickness of an orifice increase in the feeding line, damping factor increases. The feeding line with smaller diameter has more damping capacity, but damping factor increases more appreciably with blockage ratio in the feeding line with larger diameter.

Analysis of Voltage Drop under Extended Feeding in KyungBu High Speed Line (I) (경부고속선의 전력공급 안정성 검토를 위한 연장급전 조건의 전압강하 검토 (I))

  • Kim, Joo-Rak;Lee, Chang-Mu;Jang, Dong-Uk
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.1432-1438
    • /
    • 2011
  • This paper presents the simulation of traction power supply system for the evaluation of voltage drop in Kyungbu high speed line. This simulation is performed in circumstance of extended feeding through vicinity substation. Extended feeding should be considered from design of system. Therefore, voltage drop at extended feeding must be accepted against regulation. In this paper, voltage drop is evaluated under condition of extended feeding targeting section from Shinchungju and Pyungtaek S/S.

  • PDF

Estimation of the Feeding Line Capacity according to Feeding Mehtod (급전방식에 따른 급전선로의 전송용량 예측)

  • Lee, Chang-Mu;Lee, Han-Min;Oh, Se-Chan;Kim, Gil-Dong;Jang, Gil-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1169-1170
    • /
    • 2007
  • The primary objective of this paper is to examine the capacity of electrical transmission in electric railway according to the type of feeding system. Although supply capacity of railway substation are sufficient and there is no accident, due to the electrical transmission limit of feeding line the voltage breakdown may occur when large capacity of electric load at feeding line exist. So, using multi-port analysis model, we draw P-V curve due to feeding method, load, location and power factor of electric locomotive.

  • PDF

An Analysis of Influence Between the Power Feeding Line Insulation and Negative Rail Potential for the DC Ground Fault Protection in the Rubber Wheel System (고무차륜시스템에서의 지락보호를 위한 급전선로 절연과 부극전위와의 영향 분석)

  • Jung, Hosung;Shin, Seongkuen;Kim, Hyungchul;Park, Young;Cho, Sanghoon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.4
    • /
    • pp.577-583
    • /
    • 2013
  • We have analyzed influence of potential rise in negative bus, which caused by decrease of power feeding line insulation, upon protecting method of DC ground protection device which detecting potential rise between negative bus and ground in order to detect ground fault in the rubber wheel system. For this purpose, we proposed negative potential equation between negative bus and ground and calculated negative potential according to system condition changes by estimating power feeding line insulation changes in steel wheel system and rubber wheel system, and equalizing DC power feeding system when ground fault occurred. Also, in order to estimate negative potential of real system, we modeled the rubber wheel system, and simulated normal status, grounding fault occurrence and power feeding line insulation changes. In normal status, negative potential did not rise significantly regardless of vehicle operation. When ground fault occurred, negative potential rose up over 300V regardless of fault resistance. However, we also observed that negative potential rose when power feeding line insulation dropped down under $1M{\Omega}$. In conclusion, our result shows that in case of rubber wheel system unlike steel wheel system, relay will be prevented maloperation and insulation status observation can be ensured when ground over voltage relay will be set 200V ~ 300V.

Liquid Oxygen in Feeding Line during Propellant Filling and Holding (산화제 충진 및 대기 과정의 추진제 공급배관 내부 현상)

  • Kwon, Oh-Sung;Cho, Nam-Kyung;Chung, Yong-Gahp;Lee, Joong-Youp
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2007.04a
    • /
    • pp.34-37
    • /
    • 2007
  • Propellant filling and holding test was carried out using liquid oxygen as a working fluid. The feeding line system has a filter at propellant tank outlet. Vaporization of liquid oxygen during holding after completion of filling and effect of vaporization to recirculation performance in this system was observed. Filling rate and pressure of tank ullage had the effect on state of liquid oxygen in feeding line. There was no geysering in feeding line during holding because of the position of filter.

  • PDF

The Design of microstrip line-probe feeding patch array antenna (마이크로스트립 라인-프로브 급전 패치 배열 안테나의 설계)

  • 박종렬;이윤경;윤현보
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2002.11a
    • /
    • pp.285-289
    • /
    • 2002
  • In this paper, microstrip line-probe feeding patch array antenna with center frequency 5.8㎓ is designed and manufactured. The microstrip line - probe feeding structure has broadband characteristic and be able to modify the array structure for improving antenna gain. In this result, microstrip line-probe feeding patch array antenna has 17.6% bandwidth and 8㏈i antenna gain, respectively.

  • PDF

Analysis of Voltage Stability in Electric Railway Feeding System (전기철도 급전계통의 집전전압 안정도 해석)

  • Lee Chang-Mu;Lee Han-Min;Han Moon-Seob;Kim Joo-Rak;Jung Ho-Seong
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.1384-1389
    • /
    • 2004
  • The primary objective of this paper is to examine the capacity of electrical transmission in electric railway feeding system. Although supply capacity of railway substation are sufficient and there is no accident, due to the electrical transmission limit of feeding line the voltage breakdown may occur when large capacity of electric load at feeding line exist. So, using multi-port analysis model, we draw P-V curve due to the length of feeding line, load, location and power factor of electric locomotive. And through case study, compare measurement result and simulation result

  • PDF

Effects of Enternal Feeding in Gastrotomized Dogs (위절개술견에 있어서 소화관내영양식급여의 효과)

  • Kweon Oh-Kyeong
    • Journal of Veterinary Clinics
    • /
    • v.7 no.1
    • /
    • pp.403-406
    • /
    • 1990
  • The effects of enternal feeding on wound healing and intestinal movement in 30 gastrotomized dogs were investigated. The dogs were divided into enteral and parenteral feeding groups. Wound healing was evaluated with tensile strengh on the suture line 4 days after surgery and intestinal movement with the auscultation of borborygmus sound in the abdomen. There was no difference of the tensile strengh on the suture line between enternal and parenteral feeding groups. Borborygmus was auscultated in all dogs of the enteral feeding groups from day2 after surgery. It was thought that enteral feeding had no detrimental effect on wound healing as compared with the parenteral feeding and had good effect on the prevention of ileus in gastrotomized dogs.

  • PDF