• 제목/요약/키워드: Fecal-indicator bacteria

검색결과 42건 처리시간 0.032초

Intra-event variability of bacterial composition in stormwater runoff from mixed land use and land cover catchment

  • Paule-Mercado, Ma. Cristina A.;Salim, Imran;Lee, Bum-Yeon;Lee, Chang-Hee;Jahng, Deokjin
    • Membrane and Water Treatment
    • /
    • 제10권1호
    • /
    • pp.29-38
    • /
    • 2019
  • Microbial community and composition in stormwater runoff from mixed land use land cover (LULC) catchment with ongoing land development was diverse across the hydrological stage due different environmental parameters (hydrometeorological and physicochemical) and source of runoff. However, limited studies have been made for bacterial composition in this catchment. Therefore, this study aims to: (1) quantify the concentration of fecal indicator bacteria (FIB), stormwater quality and bacterial composition and structure according to hydrological stage; and (2) determine their correlation to environmental parameters. The 454 pyrosequencing was used to determine the bacterial community and composition; while Pearson's correlation was used to determine the correlation among parameters-FIB, stormwater quality, bacterial composition and structure-to environmental parameters. Results demonstrated that the initial and peak runoff has the highest concentration of FIB, stormwater quality and bacterial composition and structure. Proteobacteria, Bacteroidetes, Actinobacteria and Firmicutes were dominant bacteria identified in this catchment. Furthermore, the 20 most abundant genera were correlated with runoff duration, average rainfall intensity, runoff volume, runoff flow, temperature, pH, organic matter, nutrients, TSS and turbidity. An increase of FIB and stormwater quality concentration, diversity and richness of bacterial composition and structure in this study was possibly due to leakage from septic tanks, cesspools and latrines; feces of domestic and wild animals; and runoff from forest, destroyed septic system in land development site and urban LULC. Overall, this study will provide an evidence of hydrological stage impacts on the runoff microbiome environment and public health perspective.

Bacterial Removal Efficiencies by Unit Processes in a Sewage Treatment Plant using Activated Sludge Process (활성슬러지공정 하수종말처리장의 단위공정별 세균 제거효율)

  • Lee, Dong-Geun;Jung, Mira;Sung, Gi Moon;Park, Seong Joo
    • Journal of Korean Society on Water Environment
    • /
    • 제26권5호
    • /
    • pp.871-879
    • /
    • 2010
  • To figure out the removal efficiency of indicator and pathogenic bacteria by unit processes of a sewage treatment plant using activated sludge process, analyses were done for incoming sewage, influent and effluent of primary clarifier, aeration tank, secondary clarifier and final discharge conduit of the plant. A matrix of bacterial items (average of bacterial reduction [log/ml], p value of paired t-test, number of decreased cases of twenty analyses, removal percentage only for decreased cases) between incoming sewage and final effluent of the plant were heterotrophic plate counts (1.54, 0.000, 20, 95.01), total coliforms (1.38, 0.000, 19, 83.94), fecal coliforms (0.90, 0.000, 20, 94.84), fecal streptococci (0.90, 0.000, 20, 98.08), presumptive Salmonella (0.23, 0.561, 7, 99.09), and presumptive Shigella (1.02, 0.002, 15, 92.98). Total coliforms, fecal coliforms, heterotrophic plate counts, and fecal streptococci showed highest decrease through secondary clarifier about 1-log (p<0.001) between 88% and 96%, and primary clarifier represented the significant (p<0.05) decrease. However, final effluent through discharge conduit showed higher total coliforms and fecal streptococci than effluent of secondary clarifier (p<0.05). In addition, final effluent once violated the water quality standard while effluent of secondary clarifier satisfied the standard. Hence some control measures including elimination of deposits in discharge conduit or disinfection of final effluent are necessary.

Removal of Fecal Indicator Bacteria from Bivalves under Natural and Electrolyzed Water (패류 중 자연정화 및 인공정화에 의한 위생지표세균의 변화)

  • Oh, Eun-Gyoung;Yoo, Hyun-Duk;Yu, Hong-Sik;Ha, Kwang-Soo;Shin, Soon-Bum;Lee, Tae-Seek;Lee, Hee-Jung;Kim, Ji-Hoe;Son, Kwang-Tae
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • 제45권1호
    • /
    • pp.11-16
    • /
    • 2012
  • In coastal areas that are affected by continuous, seasonal or occasional pollution sources, bivalves accumulate biological contaminants such as pathogenic bacteria. We investigated the effect of natural seawater relaying and electrolyzed seawater depuration on the bacteriological quality of artificially contaminated oysters Crassostrea gigas and short-necked clams Ruditapes philippinarum to suggest an alternative method of shellfish sanitation control.When artificially contaminated oysters and short-necked clams (fecal coliform level 1,700 MPN/100 g) were relayed into a sea area of safe bacteriological water quality, the fecal coliform level dropped to below 110 MPN/100 g after 1 day. The bacteriological quality of oysters and short-necked clams that are contaminated at a fecal coliform level of 1,700 MPN/100 g could be improved, and become appropriate for raw consumption by a single day relay under proper environmental conditions. When artificially contaminated oysters (fecal coliform level 330 MPN/100 g) were depurated with electrolyzed seawater, 94% of fecal coliform was eliminated after 12 h and fecal coliform was undetectable after 24 h. After 24 h depuration with electrolyzed seawater, the fecal coliform level of short-necked clams with initial fecal coliform of 2,400 MPN/100 g was below 20 MPN/100 g. However, the fecal coliform level of short-necked clams with initial fecal coliform of 17,000 MPN/100 g was relatively high, at 790 MPN/100 g, even after 24 h of depuration with electrolyzed seawater, because of the repeated cycle of excretion and accumulation of fecal coliform in shellfish tissue under the closed depuration environment. Such natural seawater relaying and electrolyzed seawater depuration can be restrictively applied to improve or secure the bacteriological quality of oysters and short-necked clams in accordance with safety levels for bivalves for raw consumption.

Changes of Indicator Microorganisms and Pathogenic Bacteria in Spinach during Cook-Chill Process (시금치의 cook-chill 가공 중 오염지표균 및 병원성세균의 변화)

  • Kim, Hye-Jung;Park, Jae-Kap;Lee, Dong-Sun;Paik, Hyun-Dong
    • Korean Journal of Food Science and Technology
    • /
    • 제34권5호
    • /
    • pp.927-930
    • /
    • 2002
  • Spinach minimally processed using cook-chill and sous vide techniques was vacuum-packed in low gas permeable plastic film, pasteurized at $70^{\circ}C$ for 2 min, cooled rapidly at $3^{\circ}C$, and stored at 3 and $10^{\circ}C$. Contents of mesophilic bacteria, psychrophilic bacteria, anaerobic bacteria, spore-forming bacteria, total coliforms, yeast and molds, fecal Streptococcus, and Enterobacteriacea were measared to identify the degree of food contamination. Number of mesophilic bacteria, detected at $2.2{\times}10^8\;cfu/g$ in raw spinish, decreased to about $6.0{\times}10^3\;cfu/g$ after cook-chill process. During the storage at 3 or $10^{\circ}C$, levels of mesophilic, psychrophilic and anaerobic bacteria increased, whereas total coliforms, yeast and molds, fecal Streptococcus, and Enterobacteriacea were not detected. Twelve strains of Aeromonas hydphila, Escherichia coli O157:H7, Plesiomonas shigelloides, Pseudomonas aeruginosa, Salmonella spp., Shigella spp., Yersinia enterocolitica, Bacillus cereus, Campylococcus spp., Clostridium perfringens, Listeria monocytogenes, and Staphylococcus aureus were examined for detecting the presence of pathogenic bacteria in spinach. B. cereus and C. perfringens were isolated from raw, washed, and cook-chilled spinach, whereas A. hydrophila was isolated only from washed spinach. S. aureus was isolated from raw and washed spinach, but not from cook-chilled spinach. Other pathogenic organisms were not detected in raw, washed, and cook-chilled spinach.

Occurrence of Cryptosporidium and Giardia and the Relationship between Protozoa and Water Quality Indicators in Swimming Pools

  • Xiao, Shumin;Yin, Pengna;Zhang, Yan;Hu, Sike
    • Parasites, Hosts and Diseases
    • /
    • 제55권2호
    • /
    • pp.129-135
    • /
    • 2017
  • A total of 60 samples were collected from 35 swimming pools in Beijing, China, and the presence of Cryptosporidium and Giardia were investigated. The results showed that 16.7% and 15.0% of samples were positive for Cryptosporidium oocyst and Giardia cysts, respectively, with a mean concentration of 0.30 oocysts/10 L and 0.27 cysts/10 L. The oocysts and cysts were found to have higher rates of occurrence in August than in May. Genotyping confirmed the presence of Cryptosporidium hominis, C. parvum, and Giardia assemblages A and B, all of which were associated with human infections. The predominant species/assemblages were C. hominis and Giardia assemblage A. Analyses of the relationships between parasite oocysts/cysts, indicator bacteria, and physical-chemical parameters revealed that there was no correlation between 2 parasites and fecal bacterial indicators, whilst there was a significant correlation between protozoa and urea concentration, which indicates that urea concentration rather than fecal bacterial indicators might be an appropriate index for chlorine-resistant protozoa in swimming pools. This study provides useful information to improve the safety of swimming pool water and deduce the risk of protozoan infections.

Modeling the impact of land use change on Fecal Indicator Bacteria basin-scale transfers: assets and limitations from the SWAT model (토지이용변화에 따른 박테리아 거동 모의: SWAT 모델의 한계점과 개선점을 중심으로)

  • Kim, Min-Jeong;Jo, Gyeong-Hwa
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 한국수자원학회 2018년도 학술발표회
    • /
    • pp.49-49
    • /
    • 2018
  • 라오스의 Houay Pano 유역은 상업적 조림으로 인해 2011년부터 2013년까지 급속한 토지이용 변화를 겪어왔다. 본 연구는 이러한 토지이용변화가 박테리아 거동에 어떠한 영향을 주는지 이해하기 위해 Soil and Water Assessment Tool (SWAT) 모형을 활용한 박테리아 거동 모델링을 수행하였다. SWAT 모형은 수치 표고 모델, 토양 특성, 토지 이용 등의 정보를 종합하여, 유역 내수량 및 수질의 변화를 모의할 수 있는 모형으로, 본 연구는 대표적인 분원성 지표 세균 (Fecal Indicator Bacteria)인 대장균 (Escheichia coli, E. coli)을 대상으로 모델링을 수행하였다. SWAT 모형은 지표면 위 박테리아를 1)식물 위, 2)토양 용액상, 3)토양 입자상으로 구분하여 모의한다. 각 상태로 분할된 박테리아는 소멸 (die-off), 씻김 (wash-off), 침투, 표면 유출을 통한 수계로의 이동 등의 단계를 통하여 유역 내에서 거동한다. 본 연구는 서로 다른 기후의 영향을 배제하기 위해 각 토지이용 시나리오를 (2011, 2012, 2013) 실제 기후 조건과 동일 기후(2011-2013 평균) 조건으로 분류하여 분석하였다. 실제 기후 조건에서 SWAT 모형은 표면 유출, 토사 유출, E. coli 거동에 대해 2011년부터 2012년까지 감소, 2012년부터 2013년까지 증가로 모두 동일한 양상을 모의하였다. 이는 강수량의 양상과 동일한 것으로, 강수량이 표면 유출의 양을 결정하고, 달라진 표면 유출에 따라 토사 유출과 E. coli 거동이 결정되기 때문이다. 하지만 동일 기후 조건에서는, E. coli 거동 동인인 표면 유출과 토사 유출이 비교적 일정해짐에 따라, 각 상태로 분할된 박테리아의 초기 부하량값이 E. coli 거동을 결정하는 주된 요인임을 확인 할 수 있었다. 따라서 초기 부하량 분할에 활용되는 엽면적 지수 (Leaf Area Index)와 분배계수 (BACTKDDB)의 정확도가 요구된다. 추가적으로 본 연구는 박테리아의 유입원인 비료 모델링과, LAI를 활용한 박테리아 초기 부하량 산정, 토양 특성 변수와 토지 이용 변수의 분리, 지하수를 통한 박테리아 거동 등을 중심으로 SWAT 모형의 한계점과 개선점을 제시하였으며, 본 연구 결과는 토지이용변화가 박테리아 거동에 주는 영향을 모형적으로 이해하고, 또한 추후 박테리아 모델링 개발에 도움을 줄 것으로 예상된다.

  • PDF

Impact of Pollution Sources on the Bacteriological Water Quality in the Yongnam-Gwangdo Shellfish Growing Area of Western Jinhae Bay, Korea (진해만 서부 용남·광도해역의 세균학적 수질에 미치는 육상 오염원의 영향)

  • Shim, Kil Bo;Ha, Kwang Soo;Yoo, Hyun Duk;Lee, Tae Seek;Kim, Ji Hoe
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • 제45권6호
    • /
    • pp.561-569
    • /
    • 2012
  • To evaluate the bacteriological water quality in Yongnam-Gwangdo, located in western Jinhae Bay, seawater samples were analyzed using sanitary indicator bacteria at 57 sampling stations. According to survey results from January 2007 to December 2009, the range of the geometric mean and the estimated 90th percentile for coliforms and fecal coliforms in the samples were <1.8-16.5 and 1.8-246.8 MPN/100 mL and <1.8-7.1 and 1.8-74.8 MPN/100 mL, respectively. The samples, including those taken from stations located in Wonmunman, Gwangdo, and Dangdong, showed high levels of microbial contamination caused by the climate and weather patterns in the marine environment. The bacteriological water quality in the area met Korean criteria for a designated shellfish growing area for export and National Shellfish Sanitation Program criteria for an approved shellfish growing area, except at station #49. A total of 24 direct pollution sources were discharged into the shellfish growing area. The radius of impact was calculated for each pollution source to assess the effect on the shellfish growing area. The calculated radius of impact for most of the pollution sources was below 300 m. However, the radius of impact for the combined pollution sources in Kyeonnaeryang was 93-1973 m. There were significant differences between the calculated closed sea area and actual monitoring results. The closed sea area values calculated from the fecal coliform load in drainage water tended to be higher than the actual monitoring results. Tidal currents and environmental factors such as salinity, water temperature, sunlight, and microbiological factors affect the survival of fecal indicator bacteria in seawater.

NUMERICAL CHANGES OF THE COLIFORM BACTERIA IN A RECIRCULATING AQUARIUM (순환여과수조수의 대장균군)

  • PARK Soo-Il
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • 제11권1호
    • /
    • pp.5-8
    • /
    • 1978
  • Numerical changes of coliform bacteria in a recirculating aquarium were measured as fouling indicator. The contamination of the filter bed was mainly due to the food given to fishes, the fecal materials and the additional supply of water polluted already. Abundance of the bacteria in the aquarium was controlled by the physiochemical factors of water quality. Of these factors, pH was the main factor. Under the water temperature $20^{\circ}C$, if pH was controlled at lower than $5\~6$, the bacteria did not flourish seriously. Under the water temperature over $30^{\circ}C$, the bacterial growth was markedly decreased regardless of the pH value, and the bacterial flora seemed to be active in growth under temperature condition lower than $30^{\circ}C$.

  • PDF

Evaluation of adenosine triphosphate testing for on-farm cleanliness monitoring compared to microbiological testing in an empty pig farrowing unit

  • Yi, Seung-Won;Cho, Ara;Kim, Eunju;Oh, Sang-Ik;Roh, Jae Hee;Jung, Young-Hun;Choe, Changyong;Yoo, Jae Gyu;Do, Yoon Jung
    • Journal of Animal Science and Technology
    • /
    • 제62권5호
    • /
    • pp.682-691
    • /
    • 2020
  • Careful cleaning and disinfection of pigpens is essential to prevent disease spread and avoid the resultant economic losses. Hygiene in pigpens is generally evaluated by visual monitoring supplemented with bacteriological monitoring, which includes counting the total aerobic bacteria (TAB) and/or fecal indicator bacteria (FIB). However, these methods present drawbacks such as time and labor requirements. As adenosine triphosphate (ATP) is ubiquitous in all living organisms including microorganisms, this study aimed to directly compare the results of microbial assessment and ATP quantification, and to suggest possible detailed application methods of the ATP test for hygiene evaluation in pigpens of a farrowing unit. Before and after standard cleaning procedures, samples were collected from the floor corner, floor center, and feeding trough of four pigpens at different time points. No FIB were detected and both the TAB and ATP levels were significantly decreased in the floor center area after cleaning. FIB were continuously detected after cleaning and disinfection of the floor corners, and there was no significant ATP level reduction. The feeding trough did not show any significant difference in these values before and after cleaning, indicating insufficient cleaning of this area. The levels of TAB and ATP after cleaning were significantly correlated and the average ATP value was significantly lower in the absence of FIB than in their presence. In the absence of standard references, a more thorough hygiene management could be achieved evenly by supplementing cleaning or disinfection based on the lowest ATP results obtained at the cleanest test site, which in the present study was the floor center. Overall, these results indicate that the on-farm ATP test can be used to determine the cleanliness status, in addition to visual inspection, as an alternative to laboratory culture-based testing for the presence of microorganisms.

Investigation of Microbiological and Physiochemical Quality for Irrigation Water used in Napa Cabbage Cultivation (배추 재배에 이용되는 농업용수의 미생물 오염도 조사 및 이화학성분 분석)

  • Yun, Bohyun;Kim, Min Kyung;Ryu, Jin Hee;Kim, Won-Il;Park, Byeong-Yong;Kim, Hyun-Ju;Lee, Seung-Don;Kim, Se-Ri
    • Journal of Food Hygiene and Safety
    • /
    • 제32권5호
    • /
    • pp.396-403
    • /
    • 2017
  • The purpose of this study was to investigate water quality for irrigation water used in Napa cabbage cultivation. The water samples were analyzed for physiochemical and microbiological quality for a total of 111 samples including surface water (n = 75) and groundwater (n = 36) collected from five different regions where Napa cabbage is massively grown. As a conclusion, the levels of fecal indicators for surface water were higher than those for groundwater. The numbers of coliform from surface water and groundwater were 1.96-4.96 and 0-3.98 log MPN/100 mL, respectively. Enterococci were detected in 95% (72/75) of surface water samples and 22% (8/36) of groundwater samples. Besides, 97% (73/75) of surface water samples were observed being contaminated with Escherichia coli, and 22% (8/36) of groundwater sample was positive for E. coli. In the case of surface water, E. coli and coliform correlate to T-P, and enterococci showed relevance to the suspended solid (SS) and biochemical oxygen demand (BOD). In groundwater, fecal indicator bacteria showed relevance to the SS and chemical oxygen demand (COD). These results could be provided as fundamental date for establishing microbial standard of water used in leafy vegetables cultivation.