• Title/Summary/Keyword: Feasibility studies

Search Result 1,124, Processing Time 0.025 seconds

Study on the Maintenance Cost of Railway Infrastructure Using Line Classification and TMV Data (선로등급 및 검측차 검측정보를 고려한 철도시설 유지보수비용 산정에 관한 연구)

  • Kim, In Kyum;Lee, Jun S.;Choi, Il Yoon;Lee, Hoo Seok
    • Journal of the Korean Society for Railway
    • /
    • v.20 no.2
    • /
    • pp.275-287
    • /
    • 2017
  • During the feasibility study of new rail lines, maintenance cost of railway infrastructure has mostly been estimated based on the track length and on simplified parameters; however, the estimation reliability can be improved by employing the correction factor from UIC 715, as well as the line classification in UIC 714. The correlations between maintenance cost and various parameters such as weighted track length based on line classification, radius of curvature, gradient and worn -out rate have been analyzed according to the case studies. Prediction of the maintenance cost has been carried out using the cost data, which were representative of the whole cost data; as a result, it was demonstrated that a cost model based on the line classification and the correction factor was more reliable than the existing models. Furthermore, possibilities of using data from both the track measurement vehicle and from the maintenance information system, which are under development, have been investigated and, based on this investigation, a combined cost model using line classification, radius of curvature, gradient and worn-out rate, among other factors, will be proposed in the near future.

Thin Hardboard Manufacture from Waste Lignocellulosic Papers as Overlay Substitutes in Low Grade Plywood and Particle Board Panels(I) (고지로부터 저급합판 및 파아티클보오드 표면단판으로 사용될 수 있는 박판 하아드보오드의 제조(I))

  • Lee, Byung-Guen;Lee, Sang-Yeob
    • Journal of the Korean Wood Science and Technology
    • /
    • v.22 no.4
    • /
    • pp.19-25
    • /
    • 1994
  • The purpose of this study was to determine the technical feasibility of making 3-dimensional thin hardboard panels for overlay substitutes of low grade particleboard and plywood panels. Experimental studies were directed at assembling bench-top apparatus, learning the characteristics of different types of lignocellulosic waste papers, for making thin hardboard with several combinations of them with and without resin addition. The raw materials used are waste corrugated cartons, cereal boxes, and old magazines which contain substantial amount of lignin in it. The experimental results showed that satisfactory thin(0.21~0.16cm) hardboard could be made from the residential mixed waste papers that have selected properties comparable to commercial 0.32cm hardboard. The significant mixing ratio effect of the waste papers was present on the thickness swelling, water absorption, linear expansion, and modulus of elasticity including Taber abrasion tests of the thin hardboard made. The mixing ratio of waste papers and resin in the thin hardboard prominently affected the specific gravity of it, which led to affect modulus of elasticity and those physical properties sensitively. And it was shown that the hardboard containing those physical properties can be used for overlay substitutes of low grade plywood and particleboard panels.

  • PDF

Studies on Microbial Utilization of Agricultural Wastes (Part IV) Cellulosic Waste Materials as Substrate on the Production of Cellulosic Single Cell Protein. (농산폐자원의 미생물학적 이용에 관한 연구 (제육보) 섬유소단세포단백 생산에서의 천연기질의 이용성)

  • Bae, Moo;Ko, Young-Hee
    • Microbiology and Biotechnology Letters
    • /
    • v.5 no.1
    • /
    • pp.18-23
    • /
    • 1977
  • Experiments were carried out to pursue the availability and the feasibility of utilizable cellulosic materials as substrate for the production of cellulosic single cell protein. The resuluts were obtained as fellows. 1. Effects of carbolydrates as a sole carton source on the growth of Cellulomonas flavigena KIST 321 were examined. The result showed that cellulose and xylose would be most utlizable for cell mass production. 2. Alkaline treated waste papers and clothes resulted in good growth of the organism than intact ones did. However the waste papers as substrate of cellulosic fermentation were not digestible, even if the meterial was treated with alkalies. 3. Rice straw, rape straw and panic grass appeared to be good substrates for the cell mass production. 4. Leaves were proved to be a good substrate for the cell mass production, but wood sawdust was hardly digested by merely alkaline treatment. 5. When cellulosic wastes as the substrate were examined into the concentration of alkaline solution, the result suggested that the best productivity of cell mass from cellulosic materials was obtained on treatment with 0.8∼1.0% NaOH solution. 6. The productivity of cell mass was increased by washing out with water after alkaline treatment of newspaper, pine sawdust, lime sawdust and pine leaf.

  • PDF

Bioactive Foam Reactors for the Enhanced Biological Degradation of Toluene (계면활성제 거품을 이용한 미생물반응기에서의 기체상 톨루엔 분해)

  • Kim, Yong-Sik;Son, Young-Kyu;Khim, Jee-Hyung;Song, Ji-Hyeon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.5
    • /
    • pp.468-475
    • /
    • 2005
  • Biofilters packed with various materials have emerged as a sustainable technology for the treatment of volatile organic compounds (VOCs); however, problems including low performance and clogging are commonly encountered. Recently, a bioactive foam reactor (BFR) using surfactants has been suggested to ensure efficient and stable VOCs removal performance. This study was mainly conducted to investigate the feasibility of BFRs using toluene as a model compound. Prior to bioreactor studies, a series of bottle tests were used to select a suitable surfactant for the BFR application. Experimental results of the batch bottle tests indicated that TritonX-100 was the most appropriate one among the surfactants tested, since it showed a minimal effect on the toluene biodegradation rate while the other surfactants lowered the toluene biodegradation rate significantly. Using the selected surfactant, the BFR performance was determined by changing operating parameters including gas residence time and toluene loading. As the gas residence time increased from 0.5 minutes to 2 minutes, the toluene removal efficiency increased from approximately 50% to 80%. In addition, an increase of the toluene loading from $38\;g/m^3/hr$ to $454\;g/m^3/hr$ resulted in a decrease of toluene removal efficiency from approximately 70% to 20%. The BFR had a maximum elimination capacity of $108\;g/m^3/hr$ for toluene, which was much higher than those generally reported in the literature. The high toluene-elimination performance indicates that the BFR be a potential alternative to the conventional, packed-type biofilters. However, the limitation of toluene solubilization and foam stability at either high or low gas flow rate are still problems to be challenged.

A Success factor for Technology Commercialization for Start-ups by the Weighted-BMO Model (BMO모형을 이용한 스타트업 기술사업화 성공요인 연구)

  • Min, Kwang-Dong;Huh, Moo-Yul;Han, Jeong-Hui
    • The Journal of Industrial Distribution & Business
    • /
    • v.9 no.11
    • /
    • pp.39-54
    • /
    • 2018
  • Purpose - To success, in spite of deficient resources, a start-up company has to check various circumstances. Many researchers proposed different appraisal methods for technology commercialization. But everybody agrees Merrifield is the first one, who is a pioneer of an appraisal model of technology commercialization. After he proposed it, many researchers and field workers developed a more complicated model, which called a BMO model. In this research, considering the circumstances of start-ups that lack available resources, it proposes a new appraisal method for technology commercialization, which is named a weighted-BMO model. Research design, data, and methology - For the new BMO-model, it studied the preceding studies. And it found that the success factors for start-ups were correlated with technology commercialization. After comparing the success factors for technology commercialization of start-ups with BMO appraisal factor, it withdraws the net BMO appraisal model: which we are calling the weighted-BMO model. Results - This study found a few things. First, actually, the BMO appraisal factors related with the success factors of technology commercialization. Second, the weighted-BMO model, which included the entrepreneur ability factor, was more accurately estimated the success of technology-based start-ups than the BMO model. Third, it overcame the weakness of the BMO-model, which did not include quantitative factors. In addition to evaluating the feasibility of the BMO model, we also presented a strategy for the future direction. But, still, it included a few shortcomings, which we are calling the arbitrage of weighted value. Sometimes, the intentional weighted value can deliberate the different valuation. Conclusitons - Due to this study, the weighted-BMO model included appraisal factors related with the success factors of technology commercialization and the entrepreneur ability factor, and quantitative factors. When evaluating the combined score of the existing Merrified BMO components, 35 points of the first pass criterion accounted for 29.17% of the total score, and 80 points of the merit score of the second rank criterion were 66.67% Considering that the weighted sum is taken into account, the baseline score of the weighted summing method for each component of the modified BMO model is 2.92 points, which is 29.17% of the weighted sum total of 10 points. The evaluation score was 6.67 points, 66.67% of the weighted total score of 10 points.

Study on Local Path Control Method based on Beam Modeling of Obstacle Avoidance Sonar (장애물회피소나 빔 모델링 기반의 국부경로제어 기법 연구)

  • Kim, Hyun-Sik
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.22 no.2
    • /
    • pp.218-224
    • /
    • 2012
  • Recently, as the needs of developing the micro autonomous underwater vehicle (AUV) are increasing, the acquisition of the elementary technology is urgent. While they mostly utilizes information of the forward looking sonar (FLS) in conventional studies of the local path control as an elementary technology, it is desirable to use the obstacle avoidance sonar (OAS) because the size of the FLS is not suitable for the micro AUV. In brief, the local path control system based on the OAS for the micro AUV operates with the following problems: the OAS offers low bearing resolution and local range information, it requires the system that has reduced power consumption to extend the mission execution time, and it requires an easy design procedure in terms of its structures and parameters. To solve these problems, an intelligent local path control algorithm based on the beam modeling of OAS with the evolution strategy (ES) and the fuzzy logic controller (FLC), is proposed. To verify the performance and analyze the characteristic of the proposed algorithm, the course control of the underwater flight vehicle (UFV) is performed in the horizontal plane. Simulation results show that the feasibility of real application and the necessity of additional work in the proposed algorithm.

Test-retest Reliability and Intratest Repeatability of Measuring Lumbar Range of Motion Using Inertial Measurement Unit (관성측정장치를 이용한 요추 가동범위 측정방법의 반복성 및 검사자 내 검사-재검사 신뢰도 연구)

  • Ahn, Ji Hoon;Kim, Hyun Ho;Youn, Woo Suck;Lee, Sun Ho;Shin, You Bin;Kim, Sang Min;Park, Young Jae;Park, Young Bae
    • Journal of Acupuncture Research
    • /
    • v.31 no.1
    • /
    • pp.61-73
    • /
    • 2014
  • Objectives : The purpose of this study is to estimate the test-retest reliability and the intratest repeatability in measuring the lumbar range of motion of healthy volunteers with wireless microelectromechanical system inertial measurement unit(MEMS-IMU) system and to discuss the feasibility of this system in the clinical setting to evaluate the lumbar spine movement. Methods : 19 healthy male volunteers were participated, who got under 21 points at oswestry disability index(ODI) were adopted. Their lumbar motion were measured with IMU twice in consecutive an hour for the test-retest reliability study. Intratest repeatability was calculated in the two tests separately. The calculated intraclass correlation coefficients(ICC) were discussed and compared with the those of the previous studies. Results : Lumbar range of motion of flexion $41.45^{\circ}$, extension $16.34^{\circ}$, right lateral bending $16.41^{\circ}$ left lateral bending $13.63^{\circ}$ right rotation $-2.47^{\circ}$, left rotation $-0.61^{\circ}$. ICCs were 0.96~1.00(intratest repeatability) and 0.61~0.92(test-retest reliability). Conclusion : This study shows that MEMS-IMU system demonstrates a high test-retest reliability and intratest repeatability by calculated intraclass correlation coefficients. The results of this study represents that wireless inertial sensor measurement system has portable and economical efficiency. By MEMS-IMU system, we can measures lumbar range of motion and analyze lumbar motion effectively.

Test-retest Reliability and Intratest Repeatability of Measuring Cervical Range of Motion Using Inertial Measurement Unit (관성측정장치를 이용한 경추관절 가동범위 측정의 검사 내 반복성 및 검사-재검사 신뢰도 연구)

  • Kim, Hyun Ho;Kim, Kyung Wook;Park, Ji Min;Kim, Eun Seok;Lee, Min Jun;Kang, Jung Won;Lee, Sang Hoon;Park, Young Bae
    • Journal of Acupuncture Research
    • /
    • v.30 no.4
    • /
    • pp.25-33
    • /
    • 2013
  • Objectives : To assess the test-retest reliability and the intratest repeatability in measuring the cervical range of motion of healthy subjects with wireless microelectromechanical system inertial measurement unit(MEMS-IMU) system and to discuss the feasibility of this system in the clinical setting to evaluate the cervical spine musculoskeletal. Methods : 12 healthy people who were evaluated as no- or mild-disability with neck disability index were participated. Their cervical motion were measured with IMU twice in consecutive two days for the test-retest reliability study. Intratest repeatability was calculated in the two tests separately. The calculated intraclass correlation coefficients(ICC) were discussed and compared with the those of the previous studies. Results : Cervical range of motion data were acquired and statistically processed: left rotation($61.64^{\circ}$), right rotation($65.12^{\circ}$), extension($61.98^{\circ}$), flexion($52.81^{\circ}$), left bending($39.31^{\circ}$), right bending($41.08^{\circ}$). ICCs were 0.77~0.98(intratest repeatability) and 0.74~0.93 (test-retest reliability) in the primary motion. In the coupling motion, intratest repeatability ICCs were 0.93~ 0.99(transverse primary plane), 0.88~0.97(saggital primay plane), and 0.77~0.93(coronal primary plane). Test-retest reliability of coupling motion were 0.90~0.97(transverse primary plane), 0.00~0.72(saggital primary plane), and 0.04~0.76(coronal primary plane). Conclusions : Several types of range-of-motion devices are now on use in many fields including medicine, but the practicality of the devices in clinical use is questionable for the convenient and economical aspects. In this study, we presented the reliability of cervical range of motion test with the developed wireless MEMS-IMU system and discussed its potential utility in clinical use.

Bone formation following dental implant placement with augmentation materials at dehiscence defects in dogs : pilot study (성견의 열개형 골결손 부위에 골형성 유도술식을 동반한 임플란트 식립 후의 골형성 : pilot study)

  • Jeong, Ji-Yun;Sohn, Joo-Yeon;Chai, Kyung-Jun;Kim, Sung-Tae;Chung, Sung-Min;Lee, In-Seop;Cho, Kyoo-Sung;Kim, Chong-Kwan;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.38 no.2
    • /
    • pp.191-198
    • /
    • 2008
  • Purpose: Guided bone regeneration(GBR) has emerged as a treatment in the management of osseous defects associated with dental implants. But several studies have reported different degrees of success of guided bone regeneration, depending upon the type of barrier selected, presence or absence of an underlying graft material, types of graft material, feasibility of technique, and clinician's preference. The aim of the present study was to evaluate bone formation following dental implant placement with augmentation materials at dehiscence defects in dogs. Material and Methods: Standardized buccal dehiscence defects($3{\times}5\;mm$) were surgically 2 Mongrel dog's mandibles, each 8 SLA surface, 8 anodizing surface implants. Each buccal dehiscence defect received flap surgery only(no treatment, control), $Cytoflex^{(R)}$ membrane only, Resolut $XT^{(R)}$ membrane only, Resolut $XT^{(R)}+Osteon^{TM}$. Animals were sacrificed at 8 weeks postsurgery and block sections were harvested for histologic analysis. Resuts: All experimental group resulted in higher bone formation than control. Resolut $XT^{(R)}+Osteon^{TM}$ group resulted appeared highest defect resolution. There was no difference between SLA and anodizing surface, nonresorbable and resorbable membrane. Conclusion: GBR results in rapid and clinically relevant bone closure on dehiscence defects of the dental implants.

The Accuracy of Imprint Cytology in the Intraoperative Diagnosis of Lymph Node Metastasis in Gastric Cancer Surgery (위암 수술 중 림프절 전이의 확인을 위해 시행한 수술 중 Imprint Cytology의 결과)

  • Lee, Young-Joon;Lee, Sung-Hyun;Park, Soon-Tae;Choi, Sang-Gyeong;Hong, Soon-Chan;Jung, Eun-Jung;Joo, Young-Tae;Jeong, Chi-Young;Ha, Woo-Song
    • Journal of Gastric Cancer
    • /
    • v.5 no.3 s.19
    • /
    • pp.186-190
    • /
    • 2005
  • Purpose: Intraoperative assessment of lymph node status is important when performing limited surgery in gastric cancer patients. Currently available techniques are frozen section, imprint cytology, and other molecular methods, and most current studies use the frozen section method. In the present study, the authors focused on the accuracy and the feasibility of imprint cytology as a tool to assess the lymph node status intraoperatively in gastric cancer surgery. Materials and Methods: Between April 2001 and March 2003, we performed imprint cytology of the sentinel nodes of 260 consecutive patients. After review by an experienced cytopathologist, the sensitivity, the specificity and the overall accuracy were determined. Results: The time required for intraoperative imprint cytology was 8 minutes, and the sensitivity, the specificity and the overall accuracy were 52.2%, 88.8%, and 73.8%, respectively. Conclusion: Imprint cytology can be a useful technique for assessing lymph node status intraoperatively if the sensitivity and the specificity can be improved to an acceptable level.

  • PDF