• Title/Summary/Keyword: Faults

Search Result 2,952, Processing Time 0.028 seconds

A Study of Instrument Failure Detection in PWR Pressurizer (PWR 가압기의 계측장치 고장 진단에 관한 연구)

  • 천희영;박귀태;박승엽;김인성
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.36 no.9
    • /
    • pp.678-684
    • /
    • 1987
  • The identification problem of instrument faults in PWR pressurizer is considered. The instrument failure detection technique in this paper consists of two filters, a normal-mode Kalman filter which estimates plant states in normal operation and a bias estimator which estimates the magnitudes and directions of bias faults. The concept of threshold based on the residual of a Kalman filter in normal operation is introduced. The bias estimator is driven when the absolute value of residual exceeds the threshold. The suggested failure detection algorithm is applied to a PWR pressurizer. Computer simulations show that the prompt detection of bias fault can be performed very successfully when there exist instrument faults.

  • PDF

The analysis and countermeasure to the lightning fault of transmission facilities (송전설비의 낙뢰고장사례 분석과 대책)

  • Sin, S.G.;An, J.S.;Bak, S.Y.;NamKung, D.;Han, S.O.;Choi, N.H.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.412-415
    • /
    • 2000
  • Generally, the fault of transmission facilities occurs by natural and artificial causes. Also, these faults are frequently developed by the lightning, a natural phenomenon. Therefore, In this paper, we investigated the case of lightning faults for transmission lines occurred for five years in the west and south of chung-nam province, and then considered a suitable countermeasure for lighting faults in these area

  • PDF

Multiple Fault Detection on a Coaxial Cable via TFDR (TFDR을 이용한 동측케이블의 다중 결함 측정)

  • Ki-Seok, Kwak;Yoon, Tae-Sung;Park, Jin-Bae;Koh, Jae-Won
    • Proceedings of the KIEE Conference
    • /
    • 2006.07d
    • /
    • pp.1771-1772
    • /
    • 2006
  • In this paper, we considered multiple faults detection on a coaxial cable through Time-Frequency Domain Reflectometry (TFDR). It is well known that TFDR has high resolution accuracy for detecting and estimating the fault detection on a coaxial cable. This approach was based on time-frequency signal analysis and utilized a chirp signal multiplied by a Gaussian time envelope. The Gaussian envelope provided time localization, while the chirp allowed one to excite the system interest. We carried out experiments with 10C-FBT coaxial cable having either one or two faults. The result shows TFDR can be extended to detect multiple faults with high accuracy on a coaxial cable.

  • PDF

Design of inference engine for PLC fault diagnosis system using wrong input backward tracking algorithm (오입력 역추적 알고리즘을 이용한 PLC 고장 진단 시스템의 추론부 설계)

  • 방원철;이승하;김수광
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.706-709
    • /
    • 1996
  • In this paper, an algorithm for PLC(Programmable Logic Controller) fault diagnosis system is proposed and experimentation is conducted with a PLC and a virtual plant. Wrong output backward tracking algorithm is proposed in order to find the external faults of PLC. And query with keywords of the fault systems and specially designed test sequence programs are used. We lay emphasis on the backward tracking algorithm to diagnose the faults of PLC. It is shown experimentally that the proposed algorithm can find the faults which a typical self diagnostics in the-commercially available PLC cannot.

  • PDF

What is the Faults? (단층이란 무엇인가?)

  • Lee, Byung-Joo;Cheong, Jang-Yeong
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2007.09a
    • /
    • pp.127-137
    • /
    • 2007
  • Faults are fractures along which there is visible offset by shear displacement parallel to the fracture surface. Faults can occur as single discrete breaks, but where the rock has been repeatedly faulted, or where the rock is especially weak, no discrete break may be evident. What forms instead is a fault zone composed of countless subparallel and interconnecting closely spaced fault surfaces. Faulting is fundamentally a brittle mechanism for achieving shear displacement. At deep crustal levels where rocks tend to deform plastically under conditions of elevated temperature and confining pressure, shear displacement is achieved by and development of shear zones. In this paper authors propose the fault grade in Korea.

  • PDF

Maximum Current Estimation Method for the Backup of Current Sensor Faults

  • Kim, Jae-Yeon;Park, Si-Hyun;Suh, Young-Suk
    • Journal of information and communication convergence engineering
    • /
    • v.18 no.3
    • /
    • pp.201-206
    • /
    • 2020
  • This paper presents a new method for controlling the current of lighting LEDs without current sensors. This method can be used as backup against LED current sensor faults. LED lighting requires a circuit with a constant current in order to maintain the same brightness when the ambient temperature changes. Therefore, we propose a new current estimation method to provide backup in case of current sensor faults based on the calculation of the inductor current. In the fabricated circuit, the average current changes from 144.03 mA to 155.97 mA when the ambient temperature changes from 0℃ to 60℃. The application of this study can enable the fabrication of a driving IC for LEDs in the form of a single chip without sensing resistors. This is expected to reduce the complexity of the peripheral circuit and enable precise feedback control.

A Study on the Algorithm for Fault Discrimination in Transmission Lines using Advanced Computational Intelligence(ACI) (ACI 기법을 이용한 송전선로 고장 종류 판별에 관한 연구)

  • Park Jae Hong;Lee Jong Beom
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.619-621
    • /
    • 2004
  • This paper presents the rapid and accurate algorithm for fault discrimination in transmission lines. When faults occur in transmission lines, fault discrimination is very important. If high impedance faults occur in transmission lines, it cannot be detected by overcurrent relays. The method using current and voltage cannot discriminate high impedance fault. Because of this reason this paper uses voltage and zero sequence current, and the proposed algorithm uses fuzzy logic method. This algorithm uses voltage and zero sequence current per period in case of faults. Single line ground fault and three-phase fault can be detective using voltage. Two-line ground fault and line to line fault and high impedance can be detected using zero sequence current. To prove the performance of the algorithm, it test algorithm with signal obtained from ATPDraw simulation.

  • PDF

Power System Fault Diagnosis using Possibility Theory (가능성 이론을 이용한 전력계통 고장진단)

  • Lee, Heung-Jae;Lee, Chul-Kyun;Park, Deung-Yong;Kim, Seong-Hee;Ahn, Bok-Shin
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.6
    • /
    • pp.665-670
    • /
    • 1999
  • This paper introduces a fuzzy expert systems for fault diagnosis, where the causal relationships between faults and protective devices are defined as fuzzy relations. The uncertainties existing in the fault diagnosis are figured out using the possibility theory and the possibility measure is associated with the fuzzy relation to evaluate the possibilities of faults. Besides, the knowledge base in the expert system is described and explained. In this way, multiple-fault can be handled easily and simultaneously together with single faults.

  • PDF

A Study on Adaptive Autoreclosure Scheme with Real-time Transient Stability

  • Jang Sung-Ik;Shin Myong-Chul;Yoon Chang-Dae;Campbell Ryan C.
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.1
    • /
    • pp.8-15
    • /
    • 2006
  • Since the power swing depends on the operating time of the relay, the swing's magnitude can be reduced by an autoreclosure relaying system with an optimal reclosing algorithm. This paper proposes a method for stability improvement using optimal reclosure relaying. An optimal reclosure algorithm is applied to identify both temporary and permanent faults, and to predict system stability by applying WAM and high speed communication technology. It provides optimal control by predicting and determining the degree of stability, considering the real time transient stability using EEEAC. For temporary faults, the algorithm determines the system's stability and either recloses optimally for stable systems, or inserts series capacitance before optimal reclosure for unstable systems. It also applies an optimal reclosure algorithm to minimize shock and damage to the power system when reclosure fails due to permanent faults.

A Study on Fault Detection Method in Underground Cables using the Detecting Electro Magnetic Wave and Acoustic Signal (전자파의 음향신호측정에 의한 지중 케이블의 고장점 검출기법에 관한 연구)

  • Min, Kyoung-Rae;Kim, Hun;Yoon, Yong-Han;Kim, Jae-Chul;Song, Ho-Yub
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1357-1359
    • /
    • 1999
  • This paper presents fault detection in cables. We developed the device for detecting pinpoint location of faults in power cables using acoustic method. The proposed device consists of hardware and software for the fault detection. Using the device, we explain how to detect the pinpoint of faults and introduce that the other method use the time delay between electro-magnetic and acoustic signals for the pinpoint of the faults.

  • PDF