• Title/Summary/Keyword: Fault-prevention

Search Result 149, Processing Time 0.038 seconds

An Inducement problem on the principle liability without fault in a legislative bill of injury and relief in a medical accident (의료사고피해구제법안상 무과실책임주의 도입 문제)

  • Jeong, Yong-Yeub
    • The Korean Society of Law and Medicine
    • /
    • v.7 no.2
    • /
    • pp.271-310
    • /
    • 2006
  • In the situation of bringing out of social problem about the medical accident and medical dispute, from 1988 the enactment activity for a legislative bill on conciliation of dispute has promoted, a legislative bill on prevention and relief of medical accident was again proposed in December, 2005. This bill has been faced rough going in review process of National Assembly. Because the purpose of this legislative bill is the conciliation of interest of between medical service consumer and medical service supplier, an item of issues of law is no-fault compensation scheme. However, as no-fault compensation scheme runs counter to the principle liability with fault in our civil law, as expected, whether the inducement is valid or, if induced, the problem is not must be totally reviewed. First of all, the general of principle liability without fault and especially the medical system in foreign countries are reviewed, by reviewing an issue and the pros and cons of the inducement of no-fault compensation scheme, this article draws the conclusion. After all, considering that the necessity adapting Gefahrdungschftung in medical accident as much as other industrial fields exists, the many provisions of the principle liability without fault exists in civil law and special law of our law system, and no-fault compensation scheme let legislative purpose be, to what extent, achieved by conciliating patient and doctor, the inducement of principle liability without fault in medical field is reasonable in the aspect of politic and legal system.

  • PDF

A System IC for Controlling the Fire Prevention (화재방지제어 시스템 IC)

  • Kim, Byung-Cheul
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.4
    • /
    • pp.737-746
    • /
    • 2009
  • In this study, we have developed one chip system IC for preventing the overload, detecting an abnormal conditions, and controlling the fire prevention in the intelligent home appliances. For the purpose, a circuit detectable an electric leak for preventing an electric shock, and a circuit detectable arc that has effect directly on the fire are designed. The circuits designed on every block are verified by comparing simulation with bread-boarding using a standard transistors. The system IC is fabricated by using 34 V 2 metal $1.5{\mu}m$ bipolar transistor process from evaluation results. The electrical performances of IC application circuits and the system IC equipped on PCB board are evaluated. It is confirmed that the system IC is well operated for arc and ground fault(GF) signal.

A Analysis of a Pointed-end Equipment Arm Safety-Accident for Fault Tree Analysis (Fault Tree Analysis에 의한 첨단설비 Arm 안전사고의 분석)

  • Yun Yong-Gu;Park Beom
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2005.05a
    • /
    • pp.279-290
    • /
    • 2005
  • The purpose of this study is to attempt a Analysis of a pointed-end Equipment Arm Safety-Accident for Fault Tree Analysis. Three major techniques were used first problem is Z-Model by which accident Analysis & prevention of a pointed-end Industry can be made, Fault Tree Analysis(FTA) bywhich quantification of a pointed-end Equipment accident Analysis can be made it 5 years in past and the third, manual-written by which minimal cut set to accident can be Identified. A example has been made of issue point a pointed-end Equipment that the Arm in loader happen to Injuries. According to the Analysis lack of safety knowledge, unsafety-behavior seem to be the primal cause of accident. Comparision of the accident cause to actual report demonstratesthat the FTA a efficient tool for Industrial Accident prevention.

  • PDF

Characteristics of a FCL Applying Fast Interrupter According to the Current Limitation Elements (고속 인터럽터를 적용한 한류기의 전류제한요소에 따른 특성)

  • Im, In-Gyu;Choi, Hyo-Sang;Jung, Byung-Ik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.11
    • /
    • pp.1752-1757
    • /
    • 2012
  • With the development in industry, power demand has increased rapidly. As consumption of power has increased, Demand for new power line and electric capacity has risen. However, in the event of fault, problems occur in extending the range of fault coverage and increasing fault current. In these reasons, protection devise is recognized as the prevention of an accident and fault current. This paper dealt with minimizing fault propagation and limiting fault current by adjusting fault current limiter (FCL) with fast interrupter. At this point, we compared and analyzed characteristics between non-inductive resistance and fault current which is limited by superconducting units. In normal state of the power system, power was supplied to the load, but when fault occurred, the interrupter was operated as CT which detected the over-current. Its operation made the limitation of fault current through a FCL. We concluded that the limiter using superconducting units was more efficient with the increase of power voltage. Superconducting fault current limiter with the fast interrupter prevented the spread of a fault, and improved reliability of power system.

Development of Multiple Fault Diagnosis Methods for Intelligence Maintenance System (지적보전시스템의 실시간 다중고장진단 기법 개발)

  • Bae, Yong-Hwan
    • Journal of the Korean Society of Safety
    • /
    • v.19 no.1
    • /
    • pp.23-30
    • /
    • 2004
  • Modern production systems are very complex by request of automation, and failure modes that occur in thisautomatic system are very various and complex. The efficient fault diagnosis for these complex systems is essential for productivity loss prevention and cost saving. Traditional fault diagnostic system which perforns sequential fault diagnosis can cause catastrophic failure during diagnosis when fault propagation is very fast. This paper describes the Real-time Intelligent Multiple Fault Diagnosis System (RIMFDS). RIMFDS assesses current machine condition by using sensor signals. This system deals with multiple fault diagnosis, comprising of two main parts. One is a personal computer for remote signal generation and transmission and the other is a host system for multiple fault diagnosis. The signal generator generates various faulty signals and image information and sends them to the host. The host has various modules and agents for efficient multiple fault diagnosis. A SUN workstation is used as a host for multiple fault modules and agents for efficient multiple fault diagnosis. A SUN workstation is used as a host for multiple fault diagnosis and graphic representation of the results. RIMFDS diagnoses multiple faults with fast fault propagation and complex physical phenomenon. The new system based on multiprocessing diagnoses by using Hierarchical Artificial Neural Network (HANN).

The Arc Fault Determination Method for the Electric Fire Prevention (전기화재 방지를 위한 아크고장 판단기법에 대한 연구)

  • Ko, Yun-Seok
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.3 no.4
    • /
    • pp.260-265
    • /
    • 2008
  • The arc-fault occurring in the customer system becomes the direct cause of electric fire. However, it is very difficult to identify the arc-fault using the existing fault detection mechanism because the magnitude of the fault current is very small. Accordingly, this paper analyzes the causes of arc fault and designs the basic detection mechanism of arc fault. And then, it proposes an signal processing-based arc-fault determination methodology which can enhance the of accuracy of the arc-fault determination by applying DFT/DWT to the voltage and current waveform. Finally, this paper showed the application methodology of the proposed signal processing based fault determination method by applying and analyzing DFT/DWT to an high voltage in-rush current waveform.

  • PDF

Development of Arc Fault Circuit Interrupter Using the Distorted Voltage Wave in Electric Arc Faults (아크사고 발생 시 전압 왜형파를 이용한 아크차단기 개발)

  • Kwak, Dong-Kurl
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.6
    • /
    • pp.876-880
    • /
    • 2013
  • The major causes of electrical fire are classified to short circuit fault, overload fault, electric leakage and electric contact failure. The principal factor of the fire is electric arc or spark accompanied with such electric faults. Earth Leakage Circuit Breaker (ELB) and Molded_case Circuit Breaker (MCCB), that is, Residual Current Protective Devices (RCDs) used on low voltage distribution lines cut off earth leakage and overload, but the RCD can not cut off electric arc or spark to be a major factor of electrical fire. As the RCDs which are applied in low voltage distribution panel are prescribed to rated breaking time about 30[ms] (KS C 4613), the RCDs can't perceive to the periodic electric arc or spark of more short wavelength level. To improve such problems, this paper studies on an arc fault circuit interrupter (AFCI) using the distorted voltage wave in electric arc faults. The proposed voltage sensing type AFCI is an electrical fire prevention apparatus of new conception that operates a circuit breaker with sensing the instantaneous voltage drop of line voltage at electrical faults occurrence. The proposed AFCI is composed of control circuit topology using some semiconductor switching devices. Some experimental tests of the proposed AFCI confirm practicality and the validity of the analytical results.

A study on the detection of poor contact and arcing fault using a fuzzy logic (퍼지논리를 적용한 전기적 접촉불량 및 아크 검출에 관한 연구)

  • Kim, Hyun-Woo;Kim, In-Tae
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.205-210
    • /
    • 2007
  • This study on the prevention of electric fire. Generally the electric fire is caused by break or disconnection of the power line, short circuit and poor contact, arcing fault ect. In these causes, this paper is studied on the detection of poor contact and arcing fault. The arcing fault is caused by poor contact mainly. The arcing fault can occurs a electric fire by interaction of flammable gas and materials and it can be caused of tracking and carbonization. These phenomenons is also caused of electric fire. Therefore this paper is studied on the detection of arcing fault and poor contact.

  • PDF

A study on Fault Calculation and Coordination of Relays in Distribution System (배전계통의 고장계산 및 보호계전기 협조에 관한 연구)

  • Kim, Jun-Yoen;Nam, Hae-Kon;Kim, Tae-Seoung
    • Proceedings of the KIEE Conference
    • /
    • 1993.11a
    • /
    • pp.16-18
    • /
    • 1993
  • Recently, the scale of distribution system is being enlarged by increasing power demand. When system fault occurs, fault currents and damage power facilities increase, so system stability decreases. Effective prevention of system from fault extention becomes influential as a subject in distribution system operation. In this study, exact settings of relays are obtained from program for fault calculation and coordination of relays in distribution system. In order to make smooth coordination between relays even when power system conditions vary, operation time and sensitivity of relays are optimized. As a result, reliability of distribution system is increased with rapid and exact operation of relays when fault occurs.

  • PDF

Hydrochemistry and Noble Gas Isotopes of Groundwaters around the Fault Zones (단층대 지하수의 수리화학 및 노블가스 동위원소 특성)

  • Jeong, Chan Ho;Choi, Hyeon Young;Lee, Yong Cheon;Lee, Yu Jin;Yang, Jae Ha
    • The Journal of Engineering Geology
    • /
    • v.26 no.4
    • /
    • pp.551-559
    • /
    • 2016
  • The chemical composition and noble gas isotopes of 10 deep groundwater samples were analyzed to know the circulation of groundwaters in the Yangsan fault and the Gampo fault. The chemical types of groundwaters show the $Ca-HCO_3$ type and $Ca-SO_4(Cl)$ type, and show indistinct relationship with geology. Noble gas isotopic data of most groundwaters were plotted along the air-crust mixing line on $^3He/^4He$ vs. $4^He/^{20}Ne$ diagram, and show dominant $^3He$ of air origin except one sample that shows helium mixing of crust origin. This indicates that groundwater actively circulates along fault, and fault could not play an role of upward pathway of a deep-seated helium gas. A comparatively high $^4He$ indicates that groundwater flows in an aquifer assuring relatively enough water-rock interaction.