• Title/Summary/Keyword: Fault signal

Search Result 666, Processing Time 0.027 seconds

Application of Potassium Feldspar pIR-IRSL Method to Dating Quaternary Marine and Fluvial Terrace Sediments in Korea: A Case Study on a Fluvial Terrace and Gusan Fault in Uljin, Korea (한반도 해안-하안단구 퇴적층에 대한 K 장석 pIR-IRSL연대측정법 적용가능성 고찰: 울진 하안단구와 구산단층 연대측정)

  • Hong, Seongchan;Choi, Jeong-Heon
    • The Journal of the Petrological Society of Korea
    • /
    • v.25 no.3
    • /
    • pp.241-252
    • /
    • 2016
  • In this paper, in order to test the possibility of applying K feldspar $pIR-IRSL_{290}$ signal(read out at $290^{\circ}C$) to date old terrace sediments(up to ~ 200 ka, MIS 7) in Korea, we investigated luminescence properties of $pIR-IRSL_{290}$ signals in K feldspar extracts from 27 marine and fluvial terrace sediment samples, and these were compared with those of quartz OSL and conventional K feldspar $IRSL_{50}$ (readout at $50^{\circ}C$) signals. The averaged $2D_0$ value of K feldspar $pIR-IRSL_{290}$ growth curves was ~ 700 Gy, which is consistent with that of $IRSL_{50}$ signal, and this is 3 times higher than that for quartz OSL (~ 250 Gy) on average. Where possible, K feldspar $pIR-IRSL_{290}$ ages were compared with quartz OSL and conventional $IRSL_{50}$ ages. Our preliminary K feldspar $pIR-IRSL_{290}$ ages were older than quartz OSL ages by about 200%, while fading rate-corrected conventional $IRSL_{50}$ ages are in good agreement with those based on quartz OSL. This seems to indicate the possibility of K-feldspar $pIR-IRSL_{290}$ age overestimation due to the presence of unbleachable $pIR-IRSL_{290}$ signals, even with a prolonged exposure to sunlight. Both quartz OSL and K-feldspar $pIR-IRSL_{290}$ signals for the samples from Noeum fluvial terrace and Gusan fault site were all in dose saturation level, thus unable to estimate the formation ages of the sediments. However, $2D_0$ values derived from the dose response growth curves strongly indicate that the Noeum fluvial terrace sediments have formed before 109-140 ka, while the fluvial sediments from Gusan fault were desposited before 100-105 ka. Further, this seems to suggest that the previous quartz OSL ages of ~40-50 ka for Gusan fault sediments should be the underestimated ones due to dose saturation problem.

Efficient Fault-Tolerant Multicast on Hypercube Multicomputer System (하이퍼 큐브 컴퓨터에서 효과적인 오류 허용 다중전송기법)

  • 명훈주;김성천
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.30 no.5_6
    • /
    • pp.273-279
    • /
    • 2003
  • Hypercube multicomputers have been drawing considerable attention from many researchers due to their regular structure and short diameter. One of keys to the performance of Hypercube is the efficiency of communication among processors. Among several communication patterns, multicast is important, which is found in a variety of applications as data replication and signal processing. As the number of processors increases, the probability of occurrences of fault components also increases. So it would be desirable to design an efficient scheme that multicasts messages in the presence of faulty component. In fault-tolerant routing and multicast, there are local information based scheme, global information based scheme and limited information based scheme in terms of information. In general, limited information is easy to obtain and maintain by compressing information in a concise format. In this paper, we propose a new routing scheme and a new multicast scheme using recently proposed fully reachability information scheme and new local information scheme. The proposed multicast scheme increases multicast success possibility and reduce deroute cases. Experiments show that multicast success possibility can increase at least 15% compared to previous method.

Analysis of Electrical and Thermal Signal for Series Arc in Electrical Contact (전선의 접속부에서 직렬아크에 의한 전기적 및 열적 신호 분석)

  • Kim, Doo Hyun;Hwang, Dong Kyu
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.5
    • /
    • pp.1-7
    • /
    • 2015
  • This paper is aimed to analyze the electrical and thermal signal such as ignition possibility, ignition time, thermal characteristics and arc fault power that are associated with electrical fire in case of the occurrence of series arc at IV wiring used for interior wiring at commercial power source. In order to analyze the signal, series arc was induced by generating the constant vibration through vibrating device in the one phase (R phase) and ignition possibility was analyzed along the condition of current value by adding cotton material to the contact point of wiring. The ignition time is shortened as the electric current value increased, burning time is not associated with current value and the temperature rose up to $740^{\circ}C$ though it was not ignited. It was checked out that the temperature was the energy source enough that can generate the fire related with insulation aging of wiring and the inflammable. The possibility of electrical fire by series arc was shown as more than 12% at 5A, more than 42% at 20A and arc showed 27W at 5A, 180W at 20A. It was confirmed that the possibility of electrical fire exists at the condition as above and the circuit breaker did not operate. This data can be used as the reference value for the investigation of electrical fire or development of the circuit breaker.

Development of Operational Flight Program for Smart UAV (스마트무인기 비행운용프로그램 개발)

  • Park, Bum-Jin;Kang, Young-Shin;Yoo, Chang-Sun;Cho, Am
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.10
    • /
    • pp.805-812
    • /
    • 2013
  • The operational flight program(OFP) which has the functions of I/O processing with avionics, flight control logic calculation, fault diagnosis and redundancy mode is embedded in the flight control computer of Smart UAV. The OFP was developed in the environment of PowerPC 755 processor and VxWorks 5.5 real-time operating system. The OFP consists of memory access module, device I/O signal processing module and flight control logic module, and each module was designed to hierarchical structure. Memory access and signal processing modules were verified from bench test, and flight control logic module was verified from hardware-in-the-loop simulation(HILS) test, ground integration test, tethered test and flight test. This paper describes development environment, software structure, verification and management method of the OFP.

Development of Low Voltage Power Cable Fault Diagnosis System (저압용 전력 케이블 결함 진단 장치 개발)

  • Jeon, Jeong-Chay;Kim, Taek-Hee;Choi, Myeong-Il;Kim, Jae-Jin;Yoo, Jae-Gen;Oh, Hun
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.15-16
    • /
    • 2016
  • 본 논문에서는 케이블 결함과 위치를 검출하기 위한 SSTDR(spread spectrum domain reflectomerty) 기반의 진단 장치를 개발하였다. 개발된 진단 장치는 sstdr 기법의 검출 성능을 향상시키기 위해 시간-주파수 상관 분석을 이용하여 기준신호(reference signal)의 상관계수 최댓값 위치를 검출 한 후 기준신호를 제거하여 반사신호의 상관계수의 최댓값 위치를 검출하는 2단계 과정을 갖는다. 개발된 케이블 결함 진단 장치는 실증 시험장을 구축하고, 성능시험을 실시한 결과, ${\pm}1%$ 내 외의 오차를 갖는 것으로 확인되었다.

  • PDF

A New Mean Frequency Extension Method in Doppler System (초음파 도플러 시스템에서 새로운 평균 주파수 확장 방법)

  • 백광렬
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.2
    • /
    • pp.183-190
    • /
    • 1995
  • The use of ultrasound pulsed Doppler systems has become increasingly popular due to the advantages of easy measurements of blood velocity, volume blood blow, and irregularities of the circulatory system. However, the 2-D Doppler systems have several problems, such as range ambiguity, low signal to noise ratio, and slow frame rate. The mean frequency aliasing problem originating from the pulse repetition frequency is one of major limitations in pulsed Doppler systems. A conventional approach to resolve this problem is tracking the mean frequency close to and beyond the Nyquist frequency along the temporal axis. In this paper, a new concept of tracking the mean frequency along the spatial axis is proposed. The proposed technique is fault tolerant by nature and more suitable for multi gate and 2-D Doppler system than conventional methods.

  • PDF

Feature extraction with distance measures and fuzzy entropy

  • Lee, Sang-Hyuk;Kim, Sung-Shin;Hyeon Bae;Kim, Youn-Tae
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2003.09a
    • /
    • pp.543-546
    • /
    • 2003
  • Representation and quantification of fuzziness are required for the uncertain system modelling and controller design. Conventional results show that entropy of fuzzy sets represent the fuzziness of fuzzy sets. In this literature, the relations of fuzzy enropy, distance measure and similarity measure are discussed, and distance measure is proposed. With the help of relations of fuzzy entropy, distance measure and similarity measure, fuzzy entropy is proposed by the distance measure. Finally, proposed entropy is applied to measure the fault signal of induction machine.

  • PDF

High-resolution Seismic Study Using Weigh-drop at the Boundary of Pungam Basin (중력추를 이용한 풍암분지 경계 부근에서의 고해상도 반사파 탐사)

  • Kim, Hyoun Gyu;Kim, Ki Young
    • Economic and Environmental Geology
    • /
    • v.31 no.6
    • /
    • pp.519-526
    • /
    • 1998
  • A high-resolution seismic survey was conducted at the northeastern boundary of Pungam basin, one of the Cretaceous sedimentary basins in Korea. A 100 kg weight was used as an energy source and was found to be better than a sledge hammer in mapping deeper geologic structures. Several processing techniques such as f-k filtering, predictive deconvolution, and time-variant filtering are useful to enhance the signal-to-noise ratio by suppressing unwanted seismic energy. Four seismic units are recognized where many vertical faults are developed. The boundary fault between sedimentary rocks and Precambrian gneiss is identified along with a fracture zone of approximately 30 m wide. Bedding planes of the sedimentary rocks dipping westward are interpreted to be limbs of a syncline or volcanic flow. There faults and tilted bedding planes indicate that the basin had undergone significant tectonic deformation.

  • PDF

Design of incident signal of time-frequency domain reflectometry in application to detect fault in a XLPE cable (XLPE 전력 케이블 결함 진단을 위한 시간-주파수 영역 반사파 계측법 기준신호 설계)

  • Jang, Seung-Jin;Lee, Sin-Ho;Lee, Chun-Ku;Park, Jin-Bae
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1870-1871
    • /
    • 2011
  • 본 논문에서는 전력케이블에서의 시간-주파수 영역 반사파 계측법을 기반으로 한 기준신호를 설계한다. 사용된 기준신호는 시간과 주파수 영역에서 동시에 분석할 수 있는 가우시안 포락선을 가지는 첩 신호이다. 10m 전력케이블의 특성에 적합하게 설계된 기준신호를 케이블에 직접 인가하여 반사파를 측정하고 정규화된 시간-주파수 영역 상호상관함수로 비교 분석하였다.

  • PDF

Modelling of a Ring-type Multi-pole Inductive Position Sensor Using Magnetic Circuit Theory (자기회로 이론을 이용한 링형 다극 유도형 변위센서의 모델링)

  • 김지미;노명규
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.207-211
    • /
    • 2004
  • The performance of an inductive position sensor has approved by previous research papers. In this paper, magnetic circuit model of a ring-type multi-pole insuctive position sensor is described. The magnetic circuit model is required to design in ductive position sensor as well as draw a fault tolerance algorithm. Using the magnetic circuit theory, we derived the relationship between voltage applied and flux density in the normal air-gap. By idealizing the modulation/demodulation processes of signal processing circuit, sensor gain with respect to change of displacement is theoretically calculation using the magnetic circuit model, which validate the theoretical derivation.

  • PDF