• Title/Summary/Keyword: Fault positions

Search Result 39, Processing Time 0.026 seconds

Utilization of Energy Storage System based on the Assessment of Area of Severity in Islanded Microgrid

  • Lee, Kyebyung;Yoon, Minhan;Park, Chang-Hyun;Jang, Gilsoo
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.2
    • /
    • pp.569-575
    • /
    • 2017
  • This paper proposes a method to utilize an energy storage system (ESS) based on the assessment of an area of severity (AOS) to voltage sag. The AOS is defined as a set of the fault positions that can cause voltage sags at many buses simultaneously. The assessment of AOS helps to determine an optimal location of ESS installation to minimize the expected sag frequency (ESF) at concerned buses. The ESS has the ability not only to play traditionally known roles but also to mitigate voltage sag impact on renewable energy sources (RES) in the islanded microgrid. Accordingly, using the proposed method the ESS has additional features to prevent the operation failure of RESs and improve the stability of the microgrid. In order to verify the presented method, a case study was conducted on the sample microgrid system that is modified from an IEEE 57-bus system.

Vibration Analysis of Ball Bearing Fault using HFRT (HFRT 기법을 이용한 결함 볼베어링의 진동분석)

  • Kim, Ye-Hyun;Kang, Byoung-Yong;kim, Dong-Il;Chang, Ho-Gyeong
    • The Journal of the Acoustical Society of Korea
    • /
    • v.14 no.2
    • /
    • pp.92-100
    • /
    • 1995
  • In this study, the bearing defects were modeled and the vibration of ball bearing faults was presented for the defective pattern. The vibration signal was measured for the single and multiple defected ball bearing at the various defect positions and rotation speed, and then the signal components using the HFRT(high frequency resonance technique) were analyzed by FFT. The experimental data analysis has shown that the frequencies generated in the single or multiple defected ball bearings appear with the characteristic defect frequency and harmonics of ball pass frequency peak. Signal processing by HFRT makes it possible not only to detect the presence of a defect but also to diagnose the defect part of the bearing.

  • PDF

Orbit Ephemeris Failure Detection in a GNSS Regional Application

  • Ahn, Jongsun;Lee, Young Jae;Won, Dae Hee;Jun, Hyang-Sig;Yeom, Chanhong;Sung, Sangkyung;Lee, Jeong-Oog
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.16 no.1
    • /
    • pp.89-101
    • /
    • 2015
  • To satisfy civil aviation requirements using the Global Navigation Satellite System (GNSS), it is important to guarantee system integrity. In this work, we propose a fault detection algorithm for GNSS ephemeris anomalies. The basic principle concerns baseline length estimation with GNSS measurements (pseudorange, broadcasted ephemerides). The estimated baseline length is subtracted from the true baseline length, computed using the exact surveyed ground antenna positions. If this subtracted value differs by more than a given threshold, this indicates that an ephemeris anomaly has been detected. This algorithm is suitable for detecting Type A ephemeris failure, and more advantageous for use with multiple stations with various long baseline vectors. The principles of the algorithm, sensitivity analysis, minimum detectable error (MDE), and protection level derivation are described and we verify the sensitivity analysis and algorithm availability based on real GPS data in Korea. Consequently, this algorithm is appropriate for GNSS regional implementation.

LFSR-based PRPG with phase shifters (페이지 쉬프터를 갖는 LFSR기반의 PRPG)

  • Cho, S.J.;Choi, U.S.;Hwang, Y.H.;Kweon, M.J.;Kim, J.G.;Yim, J.M.;Heo, S.H.
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.10a
    • /
    • pp.343-346
    • /
    • 2009
  • Since an LFSR as a pattern generator has solely linear dependency in itself, it generates sequences by moving the bit positions for a pattern generation. So the correlation between the generated patterns is high and thus reduces the possibility of fault detection. To overcome these problems many researchers have studied to have goodness of randomness between the output test patterns. In this paper, we propose the new and effective method to construct phase shifter as PRPG.

  • PDF

Two-dimensional Analysis of MT Data across Northern Victoria, Australia (호주 북부 Victoria주 MT 탐사 자료의 2차원 해석)

  • Lee, Seong-Kon;Lee, Tae-Jong;Uchida, Toshihiro;Park, In-Hwa;Song, Yoon-Ho;Cull, Jim
    • Geophysics and Geophysical Exploration
    • /
    • v.13 no.4
    • /
    • pp.407-415
    • /
    • 2010
  • MT soundings were carried out in 2008, in northern Victoria, Australia, as a continuing collaboration research of 2007 between Republic of Korea, Australia, and Japan. The main purpose of this research is to investigate electrical conductivity structure and thus help understanding of tectonic structure in central Victoria, which is believed to be closely linked to mineralization and magmatic processes of this region. The survey area is located in western Lachlan Fold Belts, which is the part of Tasman Fold Belts in southeastern Australia. An MT profile of 2008 is almost parallel to the one of 2007 and approximately 50 km away. The 2D inversion result of MT data also shows that the position of conductivity discontinuity near surface are well matched with the positions of major faults, such as Avoca Fault, which is the structural boundary between Stawell and Bendigo Zones, and Heathcote Fault Zone, which marks the boundary between Bendigo and Melbourne Zones. It is also confirmed from resistivity image that internal faults in Bendigo Zone are in listric form, which is implied to be formed by structural shortening during compressional orogenic activity in Silurian.

The Analysis of Underground Utility Tunnel Positions using Lineament and GPR (선구조와 지하 투과 레이더를 이용한 지하공동구 위치 해석)

  • Jang, Ho-Sik;Seo, Dong-Ju
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.9 no.4
    • /
    • pp.142-150
    • /
    • 2006
  • In this study, GPR and lineament methods are used for the effective construction. GPR method is non-destructive testing to understand underground utility tunnel while lineament method is to understand locational environment. First, soil condition of the subject area is surveyed by location analysis. As the result of GPR survey, small-scale and large-scale of underground utility tunnel's location and scale were estimated. From the result of estimation, it is found that the main cause of underground utility tunnel's generation was not the effect of landslide or disturbed foundation from the excavation work but crack of shear & tension from the effect of fault movement which grew by insulation surroundings. From now on, this investigation method would be very useful in the survey and design stage on site for the effective construction and maintenance.

  • PDF

AC Loss Characteristics of a Single-layered Cylindrical High Temperature Superconductor (단층원통형 고온초전도도체의 교류손실 특성)

  • Ma, Yong-Hu;Li, Zhu-Yong;Ryu, Kyung-Woo;Sohn, Song-Ho;Hwang, Si-Dol
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.7
    • /
    • pp.626-630
    • /
    • 2007
  • The AC loss is an important issue in the design of the high temperature superconductor (HTS) power cables and fault current limiters. In these applications, a cylindrical HTS conductor is often used. In commercialization of these apparatuses, AC loss is a critical factor but not elucidated completely because of complexities in its measurement, e.g. non-uniform current distribution and phase difference between currents flowing in an individual HTS tape. We have prepared two cylindrical conductors composed of a Bi-2223 tape with different critical current density. In this paper, the AC loss characteristics of the conductors have been experimentally investigated and numerically analyzed. The result show that the measured losses for two conductors are not dependent on both arrangements and contact positions of a voltage lead. This implies that most of loss flux is only in the conductors. The loss for the Bi-2223 conductor with low critical current density is in good agreement with the calculated loss from Monoblock model, whereas the loss measured for the Bi-2223 conductor with high critical current density doesn't coincide with the loss calculated from the Monoblock model. The measured loss is also different from numerically calculated one based on the polygon model especially in low transport current.

Shear behavior of non-persistent joints in concrete and gypsum specimens using combined experimental and numerical approaches

  • Haeri, Hadi;Sarfarazi, V.;Zhu, Zheming;Hokmabadi, N. Nohekhan;Moshrefifar, MR.;Hedayat, A.
    • Structural Engineering and Mechanics
    • /
    • v.69 no.2
    • /
    • pp.221-230
    • /
    • 2019
  • In this paper, shear behavior of non-persistent joint surrounded in concrete and gypsum layers has been investigated using experimental test and numerical simulation. Two types of mixture were prepared for this study. The first type consists of water and gypsum that were mixed with a ratio of water/gypsum of 0.6. The second type of mixture, water, sand and cement were mixed with a ratio of 27%, 33% and 40% by weight. Shear behavior of a non-persistent joint embedded in these specimens is studied. Physical models consisting of two edge concrete layers with dimensions of 160 mm by 130 mm by 60 mm and one internal gypsum layer with the dimension of 16 mm by 13 mm by 6 mm were made. Two horizontal edge joints were embedded in concrete beams and one angled joint was created in gypsum layer. Several analyses with joints with angles of $0^{\circ}$, $30^{\circ}$, and $60^{\circ}$ degree were conducted. The central fault places in 3 different positions. Along the edge joints, 1.5 cm vertically far from the edge joint face and 3 cm vertically far from the edge joint face. All samples were tested in compression using a universal loading machine and the shear load was induced because of the specimen geometry. Concurrent with the experiments, the extended finite element method (XFEM) was employed to analyze the fracture processes occurring in a non-persistent joint embedded in concrete and gypsum layers using Abaqus, a finite element software platform. The failure pattern of non-persistent cracks (faults) was found to be affected mostly by the central crack and its configuration and the shear strength was found to be related to the failure pattern. Comparison between experimental and corresponding numerical results showed a great agreement. XFEM was found as a capable tool for investigating the fracturing mechanism of rock specimens with non-persistent joint.

Russia-Ukraine War and a Change in the International Order (러시아-우크라이나 전쟁과 국제질서의 변화)

  • Jang, Seho
    • Analyses & Alternatives
    • /
    • v.6 no.2
    • /
    • pp.5-36
    • /
    • 2022
  • The Russia-Ukraine War was a "three-layer compounded war" between the US and Russia, Russia and Ukraine, and Ukrainian government forces and rebels. First, the war is a phenomenon that occurred when the western sphere of influence seeking to maintain and strengthen the liberal international order and the Sino-Russian sphere of influence seeking a new alternative order collided in Ukraine, a geopolitical fault zone. Second, this war is the result of a typical 'security dilemma' phenomenon caused by the 'chain reaction' game of NATO's continuous expansion and Russia's response. Third, the Russia-Ukraine war was caused by the Russian military projection to prevent the military restoration of Donbas region by Ukraine. Until now, the Western world, led by the US, showed unexpected solidarity after the war despite subtle differences in positions. However, the non-Western world, including China, is not participating in the condemnation and sanctions against Russia. This war will be an important turning point in the existence and change of the current international order that has been formed and is operating since the end of the Cold War. The direction of maintenance/restoration, revision/change, and end/transformation of the current international order is highly likely to be determined depending on the development pattern and method of ending the war.