• Title/Summary/Keyword: Fault Safety

Search Result 814, Processing Time 0.036 seconds

Actuator Fault Detection and Adaptive Fault-Tolerant Control Algorithms Using Performance Index and Human-Like Learning for Longitudinal Autonomous Driving (종방향 자율주행을 위한 성능 지수 및 인간 모사 학습을 이용하는 구동기 고장 탐지 및 적응형 고장 허용 제어 알고리즘)

  • Oh, Sechan;Lee, Jongmin;Oh, Kwangseok;Yi, Kyongsu
    • Journal of Auto-vehicle Safety Association
    • /
    • v.13 no.4
    • /
    • pp.129-143
    • /
    • 2021
  • This paper proposes actuator fault detection and adaptive fault-tolerant control algorithms using performance index and human-like learning for longitudinal autonomous vehicles. Conventional longitudinal controller for autonomous driving consists of supervisory, upper level and lower level controllers. In this paper, feedback control law and PID control algorithm have been used for upper level and lower level controllers, respectively. For actuator fault-tolerant control, adaptive rule has been designed using the gradient descent method with estimated coefficients. In order to adjust the control parameter used for determination of adaptation gain, human-like learning algorithm has been designed based on perceptron learning method using control errors and control parameter. It is designed that the learning algorithm determines current control parameter by saving it in memory and updating based on the cost function-based gradient descent method. Based on the updated control parameter, the longitudinal acceleration has been computed adaptively using feedback law for actuator fault-tolerant control. The finite window-based performance index has been designed for detection and evaluation of actuator performance degradation using control error.

OPRoS based Fault Tolerance Support for Reliability of Service Robots (서비스로봇의 신뢰성 향상을 위한 OPRoS 기반 Fault-tolerance 기법)

  • Ahn, Hee-June;Lee, Dong-Su;Ahn, Sang-Chul
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.16 no.6
    • /
    • pp.601-607
    • /
    • 2010
  • For commercial success of emerging service robots, the fault tolerant technology for system reliability and human safety is crucial. Traditionally fault tolerance methods have been implemented in application level. However, from our studies on the common design patterns in fault tolerance, we argue that a framework-based approach provides many benefits in providing reliability for system development. To demonstrate the benefits, we build a framework-based fault tolerant engine for OPRoS (Open Platform for Robotic Services) standards. The fault manager in framework provides a set of fault tolerant measures of detection, isolation, and recovery. The system integrators choose the appropriate fault handling tools by declaring XML configuration descriptors, considering the constraints of components and operating environment. By building a fault tolerant navigation application from the non-faulttolerant components, we demonstrate the usability and benefits of the proposed framework-based approach.

A Study on the Protection System for AT Feeding on the Electric Railway (전기철도 AT급전방식 보호시스템 최적구성 방안 연구)

  • 창상훈;이형수;홍재승;김정훈
    • Proceedings of the KSR Conference
    • /
    • 1999.11a
    • /
    • pp.344-351
    • /
    • 1999
  • The safe operation of electro railways is greatly dependant on its protective systems. The system so-called Fault Protection Wire(FW) is now widely adapted to protect in AT feeding systems. It is connected between the feeder and trolley circuit to return the fault current to autotransfonmers at substation. This paper computed the distribution of fault currents at FW in the system and also evaluated the safety from electric shock when ground fault or flashover occur in the feeding system. The results show FW is useful to protect power supply network from fault in electric railways

  • PDF

Radio Communication Based Train Control system architecture and handoff scheme for supporting the safety and reliability (안정성과 신뢰성을 고려한 무선통신기한 열차제어시스템 (Radio CBTC) 구조 및 핸드오프 방법)

  • 윤용기;정락교;이병송;최규형;황현철;이재호;곽경섭
    • Proceedings of the KSR Conference
    • /
    • 2000.11a
    • /
    • pp.594-601
    • /
    • 2000
  • Communication Based Train Control System supports the easy maintenance & management and also have the capability to send more informations than the existing one but is less expensive. Tolerance against fault/failure and reliable data transmission are very important issues with this system since it has the responsibility of man's safety. In this paper, we suggested the schemes to support the reliable transmission quality and fault safety. Also we verified through simulation.

  • PDF

Minimal Cut Set of Electric Power Installations using Fault Tree Analysis (FTA를 이용한 수변전설비의 최소절단집합 도출)

  • Park, Young-Ho;Kim, Doo-Hyun;Kim, Sung-Chul
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.1
    • /
    • pp.41-46
    • /
    • 2017
  • In this paper, from making an electrical fire which is thought to be the most damaging among potential dangers as a top event, minimal cut sets (MCS) about it were analyzed. For this, components of a power substation were classified into 15 items. Failure rates and modes were extracted based on Korea Electrical Safety Corporation, IEEE Gold Book, and RAC. To analyze the top event (an electrical fire), main events were assorted into "safety devices for overcurrent" and "ampere meter of detecter". Failure of components was divided into failure of VCB, COS, and MCCB. A fault tree was composed of 3 AND gate, 5 OR gates and 17 basic events. Overlapped events among the basic events are things which occur from relevant components. They were attached to the tree by distinguishing identifiers. In case of FT, two minimal cut sets of "IO_METER", "MF_METER", "DO_MCCB" and "IO_METER", "MF_METER", "DO_VCB" take 46% of electrical fires. Therefore, about basic events which are included in the top two minimum cut sets, strict control is necessary.

Safety Assessment Analysis of the Rotorcraft Fuel Pumps (회전익기 연료펌프 안전성 평가 분석)

  • Lee, Junghoon;Park, Jang-Won
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.21 no.2
    • /
    • pp.21-25
    • /
    • 2013
  • The system and components for aircraft are required the design data on which the safety requirements are properly reflected for their certification. This paper presents the procedure and results of a safety assessments analysis for the rotorcraft fuel pumps in oder to confirm and verify them. The fuel pumps design assessment must be performed, including a detailed failure analysis to identify all failures that will prevent continued safe flight or safe landing. In order to assess the fuel pumps design safety, not only system safety hazard analysis and but FTA(Fault Tree Analysis) for proofing the safety objective of the fuel pumps are performed. The results of the safety assessment for fuel pumps validate that no single failure or malfunction could result in catastrophic failure or critical accidents of the rotorcraft.

An Experimental Study on Operation Setting Optimization of Circuit Breaker for Improving Safety on DC Railroad Feeder System (직류철도 급전계통의 안전성 향상을 위한 차단기 동작 최적 설정의 실험적 고찰)

  • Lee, Jae-Bong;Jung, No-Geon;Kim, Jae-Moon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.3
    • /
    • pp.526-531
    • /
    • 2016
  • This paper presents an experimental study on the optimal settings for the selected DC fault relay (50F) to improve the operating performance for the high-speed circuit breaker on DC feeding system which ensure safety within rolling stock maintenance depot. In this study, current supplied to overhead contact wire was calculated on 1 ms interval to analyze the correction values of DC fault selective relay for the operation of current supply cutout. Particularly, standards for the accurate detection of accidents between an electric railway vehicle and the electric power facilities are shown by investigating the optimal correction values for detection of fault current, and the results indicated that it takes about 213 ms for the DC fault selective relay(50F) to fully open. In the future, the correction values of DC fault selective relay suggested in this paper will be used as the reference values of protective relay for the safe operation of DC electric railroad system such as urban railway.

Support vector ensemble for incipient fault diagnosis in nuclear plant components

  • Ayodeji, Abiodun;Liu, Yong-kuo
    • Nuclear Engineering and Technology
    • /
    • v.50 no.8
    • /
    • pp.1306-1313
    • /
    • 2018
  • The randomness and incipient nature of certain faults in reactor systems warrant a robust and dynamic detection mechanism. Existing models and methods for fault diagnosis using different mathematical/statistical inferences lack incipient and novel faults detection capability. To this end, we propose a fault diagnosis method that utilizes the flexibility of data-driven Support Vector Machine (SVM) for component-level fault diagnosis. The technique integrates separately-built, separately-trained, specialized SVM modules capable of component-level fault diagnosis into a coherent intelligent system, with each SVM module monitoring sub-units of the reactor coolant system. To evaluate the model, marginal faults selected from the failure mode and effect analysis (FMEA) are simulated in the steam generator and pressure boundary of the Chinese CNP300 PWR (Qinshan I NPP) reactor coolant system, using a best-estimate thermal-hydraulic code, RELAP5/SCDAP Mod4.0. Multiclass SVM model is trained with component level parameters that represent the steady state and selected faults in the components. For optimization purposes, we considered and compared the performances of different multiclass models in MATLAB, using different coding matrices, as well as different kernel functions on the representative data derived from the simulation of Qinshan I NPP. An optimum predictive model - the Error Correcting Output Code (ECOC) with TenaryComplete coding matrix - was obtained from experiments, and utilized to diagnose the incipient faults. Some of the important diagnostic results and heuristic model evaluation methods are presented in this paper.

Systematic Evaluation of Fault Trees using Real-Time Model Checker (실시간 모델 체커를 이용한 풀트 트리의 체계적 검증)

  • 지은경;차성덕;손한성;유준범;구서룡;성풍현
    • Journal of KIISE:Software and Applications
    • /
    • v.29 no.12
    • /
    • pp.860-872
    • /
    • 2002
  • Fault tree analysis is the most widely used saftly analysis technique in industry. However, the analysis is often applied manually, and there is no systematic and automated approach available to validate the analysis result. In this paper, we demonstrate that a real-time model checker UPPAAL is useful in formally specifying the required behavior of safety-critical software and to validate the accuracy of manually constructed fault trees. Functional requirements for emergency shutdown software for a nuclear power plant, named Wolsung SDS2, are used as an example. Fault trees were initially developed by a group of graduate students who possess detailed knowledge of Wolsung SDS2 and are familiar with safety analysis techniques including fault tree analysis. Functional requirements were manually translated in timed automata format accepted by UPPAAL, and the model checking was applied using property specifications to evaluate the correctness of the fault trees. Our application demonstrated that UPPAAL was able to detect subtle flaws or ambiguities present in fault trees. Therefore, we conclude that the proposed approach is useful in augmenting fault tree analysis.

Fault Tree Analysis and Reliability Analysis by Fuzzy Set Approach (퍼지집합에 의한 FT 분석 및 신뢰성분석)

  • Kim, Gil-Dong;Cho, Am
    • Journal of the Korean Society of Safety
    • /
    • v.12 no.3
    • /
    • pp.155-160
    • /
    • 1997
  • The conventional fault tree and reliability analysis gives in many cases insufficient information concerning the relative frequencies of hazard events. This stems from that the basic events are not stationary and ergodic, and therefore the tolerances of the induced and top events cannot be calculated reliably based on the classical probability theory. To overcome this difficulty, the paper considers the relative frequencies of the basic events as fuzzy numbers and uses instead of probability, possible considerations for evaluating the mean values and tolerances of the top events. The possibility distribution of the basic events can be approximated based on heuristic considerations. This paper shows the use of these operators for constructing fault trees. The use of the method for numerical calculation is demonstrated on a field safety problem.

  • PDF