• Title/Summary/Keyword: Fault Monitor

Search Result 156, Processing Time 0.025 seconds

Implementation of an Integrated Machine Condition Monitoring Algorithm Based on an Expert System (전문가시스템을 기반으로 한 통합기계상태진단 알고리즘의 구현(I))

  • 장래혁;윤의성;공호성;최동훈
    • Tribology and Lubricants
    • /
    • v.18 no.2
    • /
    • pp.117-126
    • /
    • 2002
  • Abstract - An integrated condition monitoring algorithm based on an expert system was implemented in this work in order to monitor effectively the machine conditions. The knowledge base was consisted of numeric data which meant the posterior probability of each measurement parameter for the representative machine failures. Also the inference engine was constructed as a series of statistical process, where the probable machine fault was inferred by a mapping technology of pattern recognition. The proposed algorithm was, through the user interface, applied for an air compressor system where the temperature, vibration and wear properties were measured simultaneously. The result of the case study was found fairly satisfactory in the diagnosis of the machine condition since the predicted result was well correlated to the machine fault occurred.

A Study on Diagnosing Fouling of Heat Exchangers of a Hybrid Heat Pump (하이브리드 열펌프 열교환기 오염 진단 연구)

  • Shin, Younggy
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.5
    • /
    • pp.240-246
    • /
    • 2014
  • A fault detector was developed for heat exchangers of a hybrid heat pump (HP) for household. The proposed detector can be applied directly to raw operating data. It is to monitor a tracking error between a measured saturation temperature and its state observer. The observer was estimated from a state-space model simulating dynamics of a heat exchanger. The real hybrid HP was substituted with a dynamic simulator that implemented two-phased heat transfer and was validated by experimental data. And artificial fault data were generated using the simulator. Diagnosing the data showed the following. The residual calculated from the state observer error shows a relatively robust consistency with respect fouling level. The fault detector is practically useful because it detects a threshold fouling beyond which the performance starts to deteriorate significantly.

Architecture Modeling of a Performance Report Tool for a Cluster System (클러스터 시스템의 성능 레포트 툴의 아키텍처 모델링)

  • Kim, Ki;Choi, Eun-Mi
    • Proceedings of the Korea Society for Simulation Conference
    • /
    • 2003.06a
    • /
    • pp.67-71
    • /
    • 2003
  • In order to manage a cluster system that consists of a number servers, management aspects such as configuration management, fault management, performance management, and user management should be considered. Especially, it is necessary to monitor performances for performance and fault management. An agent in each server collects performance counters, status changes, and events occurred in normal or abnormal states. The data collected are delivered to a collector sorter and processed in a report tool for performance analysts and management decision in the cluster system point of view, by detecting fault state and tracing out resource usage, service response, and response, and states until failed. In this paper we propose an architecture modeling of a performance report tool for proactive cluster system management. Some results on a cluster system are presented.

  • PDF

A Development of mobile broadcasting monitor for improving reliability on IP-TV Platform based on TIT (TIT 기반에 IP-TV 플랫폼의 신뢰성 향상을 위한 방송 모니터 개발)

  • Sso, Sang-Jin;Jin, Hyun-Joon;Park, Noh-Kyung
    • Journal of Internet Computing and Services
    • /
    • v.8 no.5
    • /
    • pp.59-66
    • /
    • 2007
  • In korea, TIT(Transport Information Technology) based IP-TV services have been provided in Saemaeul trains and some sections of subway trains, But the software systems for the service performed in alternated fashions and suffered from many problems such as suspension, memory leaking and overflow, These problems increased playback loss time and resulted in bad reliabilities, In this paper, a software TIT monitor is designed and implemented for Monitoring module and Reset module in physically poor environments, The designed system formalized monitoring time intervals for effective monitoring, Through the real experiments, playback time is improved in 7.2% comparing to existing system.

  • PDF

Along-Track Position Error Bound Estimation using Kalman Filter-Based RAIM for UAV Geofencing

  • Gihun, Nam;Junsoo, Kim;Dongchan, Min;Jiyun, Lee
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.12 no.1
    • /
    • pp.51-58
    • /
    • 2023
  • Geofencing supports unmanned aerial vehicle (UAV) operation by defining stay-in and stay-out regions. National Aeronautics and Space Administration (NASA) has developed a prototype of the geofencing function, SAFEGUARD, which prevents stayout region violation by utilizing position estimates. Thus, SAFEGUARD depends on navigation system performance, and the safety risk associated with the navigation system uncertainty should be considered. This study presents a methodology to compute the safety risk assessment-based along-track position error bound under nominal and Global Navigation Satellite Systems (GNSS) failure conditions. A Kalman filter system using pseudorange measurements as well as pseudorange rate measurements is considered for determining the position uncertainty induced by velocity uncertainty. The worst case pseudorange and pseudorange rate fault-based position error bound under the GNSS failure condition are derived by applying a Receiver Autonomous Integrity Monitor (RAIM). Position error bound simulations are also conducted for different GNSS fault hypotheses and constellation conditions with a GNSS/INS integrated navigation system. The results show that the proposed along-track position error bounds depend on satellite geometries caused by UAV attitude change and are reduced to about 40% of those of the single constellation case when using the dual constellation.

Multi-block PCA for Sensor Fault Detection and Diagnosis of City Gas Network (도시가스 배관망의 고장 탐지 및 진단을 위한 다중블록 PCA 적용 연구)

  • Yeon-ju Baek;Tae-Ryong Lee;Jong-Seun Kim;Hong-Cheol Ko
    • Journal of the Korean Institute of Gas
    • /
    • v.28 no.2
    • /
    • pp.38-46
    • /
    • 2024
  • The city gas pipeline network is characterized by being widely distributed and hierarchically connected in a complex manner over a wide area. In order to monitor the status of the widely distributed network pressures with high precision, Multi-block PCA(MBPCA) is recommended. However, while MBPCA has excellent performance in identifying faulty sensors as the number of sensors increases, the fault detection performance deteriorates, and also there is a problem that the model needs to be updated entirely even if minor changes occur. In this study, we developed fault detectability index and fault identificability index to determine the effectiveness of MBPCA application block by block. Based on these indices, we distinguished MBPCA and PCA blocks and developed a fault detection and diagnostic system for the city gas pipeline network of Haean Energy Co., Ltd., and were able to solve the problems that arise when there are many sensors.

Design of Computer Hardware Fault Detector using ROM BIOS (ROM BIOS를 이용한 컴퓨터 하드웨어 장애인식 모듈 설계)

  • Nahm, Eui-Seok
    • Journal of the Korea Convergence Society
    • /
    • v.4 no.3
    • /
    • pp.21-26
    • /
    • 2013
  • Currently almost people use a personal computer for various purpose. But some people are not familiar to computer system. If they see only black screen on the monitor when they turn on the computer power, they can not recognize whether it is hardware or software faults. So, in this paper is aimed to develop the module of computer hardware fault detecter using ROM BIOS before OS booting. This module use PCI interface with mother board of computer. Before os booting, it can get the ROM BIOS memory by interrupt and show what hardware is fault according to the predefined memory content of BIOS.

A Study on the Fault Diagnosis of Roller-Shape Using Frequency-Domain Analysis of Tension Signals (장력신호의 주파수 해석을 이용한 롤 형상 이상 진단에 관한 연구)

  • Sin, Gi-Hyeon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.12
    • /
    • pp.107-114
    • /
    • 2000
  • Rollers and rolls in the continuous process systems are noes of key components that determine the quality of web products. The condition of rollers and rolls(ex. eccentricity wear) should be consistently monitored in order to maintain the process conditions (ex. tension, edge position) within a required specification. In this paper, a new diagnosis technique is suggested to detect the defect of rollers/rolls (ex. eccentricity, wear) based on frequency domain analysis of web tension signal. The kernel of this technique is to use the spectrum amplitude of tension signal which allows to identify the fault rollers/rolls and to also diagnose the degree of fault in corresponding rollers and rolls. The experimental results proved that the suggested diagnosis technique can be successfully used to identify the defect rollers and rolls as well as to diagnose the degree of the defect of those rollers. The suggested technique can be applied to monitor and diagnose the shape of rollers and rolls in various multi-span web transport systems.

  • PDF

Diagnosing the Cause of Operational Faults in Machine Tools with an Open Architecture CNC

  • Kim Dong Hoon;Kim Sun Ho;Song Jun-Yeob
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.8
    • /
    • pp.1597-1610
    • /
    • 2005
  • The conventional computerized numerical controller (CNC) of machine tools has been increasingly replaced by a PC-based open architecture CNC (OAC) that is independent of a CNC vendor. The OAC and machine tools with an OAC have led to a convenient environment in which user-defined applications can be efficiently implemented within a CNC. This paper proposes a method of diagnosing the cause of operational faults. The method is based on the status of a programmable logic controller in machine tools with an OAC. An operational fault is defined as a disability that occurs during the normal operation of machine tools. Operational faults constitute more than 70 percent of all faults and are also unpredictable because most of them occur without any warning. To quickly and correctly diagnose the cause of an operational fault, two diagnostic models are proposed: the switching function and the step switching function. The cause of the fault is logically diagnosed through a fault diagnosis system using diagnostic models. A suitable interface environment between a CNC and developed application modules is constructed to implement the diagnostic functions in the CNC domain. The results of the diagnosis were displayed on a CNC monitor for machine operators and transmitted to a remote site through a Web browser. The proposed diagnostic method and its results were useful to unskilled machine operators and reduced the machine downtime.

A Study on Multi Fault Detection for Turbo Shaft Engine Components of UAV Using Neural Network Algorithms

  • Kong, Chang-Duk;Ki, Ja-Young;Kho, Seong-Hee;Lee, Chang-Ho
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.03a
    • /
    • pp.187-194
    • /
    • 2008
  • Because the types and severities of most engine faults are various and complex, it is not easy that the conventional model based fault detection approach like the GPA(Gas Path Analysis) method can monitor all engine fault conditions. Therefore this study proposed newly a diagnostic algorithm for isolating and diagnosing effectively the faulted components of the smart UAV propulsion system, which has been developed by KARI(Korea Aerospace Research Institute), using the fuzzy logic and the neural network algorithms. A precise performance model should be needed to perform the model-based diagnostics. The based engine performance model was developed using SIMULINK. For the work and mass flow matching between components of the steady-state simulation, the state-flow library was applied. The proposed steady-state performance model can simulate off-design point performance at various flight conditions and part loads, and in order to evaluate the steady-state performance model their simulation results were compared with manufacturer's performance deck data. According to comparison results, it was confirm that the steady-state model well agreed with the deck data within 3% in all flight envelop. The diagnosis procedure of the proposed diagnostic system has the following steps. Firstly after obtaining database of fault patterns through performance simulation, then secondly the diagnostic system was trained by the FFBP networks. Thirdly after analyzing the trend of the measuring parameters due to fault patterns, then fourthly faulted components were isolated using the fuzzy logic. Finally magnitudes of the detected faults were obtained by the trained neural networks. Because the detected faults have almost same as degradation values of the implanted fault pattern, it was confirmed that the proposed diagnostic system can detect well the engine faults.

  • PDF