• Title/Summary/Keyword: Fault Frequency

Search Result 604, Processing Time 0.031 seconds

Resonance Investigation and Active Damping Method for VSC-HVDC Transmission Systems under Unbalanced Faults

  • Tang, Xin;Zhan, Ruoshui;Xi, Yanhui;Xu, Xianyong
    • Journal of Power Electronics
    • /
    • v.19 no.6
    • /
    • pp.1467-1476
    • /
    • 2019
  • Grid unbalanced faults can cause core saturation of power transformer and produce lower-order harmonics. These issues increase the electrical stress of power electronic devices and can cause a tripping of an entire HVDC system. In this paper, based on the positive-sequence and negative-sequence impedance model of a VSC-HVDC system as seen from the point of common connection (PCC), the resonance problem is analyzed and the factors determining the resonant frequency are obtained. Furthermore, to suppress over-voltage and over-current during resonance, a novel method using a virtual harmonic resistor is proposed. The virtual harmonic resistor emulates the role of a resistor connected in series with the commutating inductor without influencing the active and reactive power control. Simulation results in PSCAD/EMTDC show that the proposed control strategy can suppress resonant over-voltage and over-current. In addition, it can be seen that the proposed strategy improves the safety of the VSC-HVDC system under unbalanced faults.

Required Capacity Assessment of Energy Storage System for Relieving Operation Condition of SPS Using Generator Acceleration Energy (발전기 가속에너지를 이용한 고장파급방지장치 운전조건 완화용 전기저장장치 적정용량 산정방안)

  • Song, Seung-Heon;Choi, Woo-Yeong;Gwon, Han-Na;Kook, Kyung Soo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.68 no.1
    • /
    • pp.1-7
    • /
    • 2019
  • Due to the highly concentrated power plants integrated through the limited transmission lines in Korea, a Special Protection System(SPS) has been applied to stabilize the power systems by instantly tripping the pre-determined generators in a large-scaled power plant when a fault occurs on the drawing transmission lines. Moreover, power outputs of those generators are constrained to avoid any activation of Under Frequency Load Shedding(UFLS) even after those generators are tripped by SPS action. For this, this paper proposes a method for calculating the required capacity of Energy Storage System(ESS) expected to relieve the operating constraints to generators using its fast response for controlling power system frequency. The proposed method uses the generator acceleration energy to derive the stable condition during the SPS action. In addition, its effectiveness is verified by the case studies adopting actual SPS operations in Korean power systems.

Development Direction of Reliability-based ROK Amphibious Assault Vehicles (신뢰성 기반 한국군 차기 상륙돌격장갑차 발전방향)

  • Baek, Ilho;Bong, Jusung;Hur, Jangwook
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.2
    • /
    • pp.14-22
    • /
    • 2021
  • A plan for the development of reliability-based ROK amphibious assault vehicles is proposed. By analyzing the development case of the U.S. EFV, considerations for the successful development of the next-generation Korea Forces amphibious assault vehicle are presented. If the vehicle reliability can be improved to the level of the fourth highest priority electric unit for power units, suspensions, decelerators, and body groups, which have the highest priority among fault frequency items, a system level MTBF of 36.4%↑ can be achieved, and the operational availability can be increased by 3.5%↑. The next-generation amphibious assault vehicles must fulfill certain operating and performance requirements, the underlying systems must be built, and sequencing of the hybrid engine and the modular concept should be considered. Along with big-data- and machine-learning-based failure prediction, machine maintenance based on augmented reality/virtual reality and remote maintenance should be used to improve the ability to maintain combat readiness and reduce lifecycle costs.

Internal Event Level 1 Probabilistic Safety Assessment for Korea Research Reactor (국내 연구용원자로 전출력 내부사건 1단계 확률론적안전성평가)

  • Lee, Yoon-Hwan;Jang, Seung-Cheol
    • Journal of the Korean Society of Safety
    • /
    • v.36 no.3
    • /
    • pp.66-73
    • /
    • 2021
  • This report documents the results of an at-power internal events Level 1 Probabilistic Safety Assessment (PSA) for a Korea research reactor (KRR). The aim of the study is to determine the accident sequences, construct an internal level 1 PSA model, and estimate the core damage frequency (CDF). The accident quantification is performed using the AIMS-PSA software version 1.2c along with a fault tree reliability evaluation expert (FTREX) quantification engine. The KRR PSA model is quantified using a cut-off value of 1.0E-15/yr to eliminate the non-effective minimal cut sets (MCSs). The final result indicates a point estimate of 4.55E-06/yr for the overall CDF attributable to internal initiating events in the core damage state for the KRR. Loss of Electric Power (LOEP) is the predominant contributor to the total CDF via a single initiating event (3.68E-6/yr), providing 80.9% of the CDF. The second largest contributor is the beam tube loss of coolant accident (LOCA), which accounts for 9.9% (4.49E-07/yr) of the CDF.

Capacitor Failure Detection Technique for Microgrid Power Converter (마이크로그리드 전력변환장치용 커패시터 고장 검출 기법)

  • Woo-Hyun Lee;Gyang-Cheol Song;Jun-Jae An;Seong-Mi Park;Sung-Jun Park
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.6_2
    • /
    • pp.1117-1125
    • /
    • 2023
  • The DC part of the DC microgrid power conversion system uses capacitors for buffers of charge and discharge energy for smoothing voltage and plays important roles such as high frequency component absorption, power balancing, and voltage ripple reduction. The capacitor uses an aluminum electrolytic capacitor, which has advantages of capacity, low price, and relatively fast charging/discharging characteristics. Aluminum electrolytic capacitors(AEC) have previous advantages, but over time, the capacity of the capacitors decreases due to deterioration and an increase in internal temperature, resulting in a decrease in use efficiency or an accident such as steam extraction due to electrolyte evaporation. It is necessary to take measures to prevent accidents because the failure diagnosis and detection of such capacitors are a very important part of the long-term operation, safety of use, and reliability of the power conversion system because the failure of the capacitor leads to not only a single problem but also a short circuit accident of the power conversion system.

Predictive Flooded Area Susceptibility and Verification Using GIS and Frequency Ratio (빈도비 모델과 GIS을 이용한 침수 취약 지역 예측 기법 개발 및 검증)

  • Lee, Moung-Jin;Kang, Jung-Eun
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.15 no.2
    • /
    • pp.86-102
    • /
    • 2012
  • For predictive flooded area susceptibility mapping, this study applied and verified probability model and the frequency ratio using a geographic information system (GIS) and frequency raio. Flooded areas were identified in the study area of field surveys, For predictive flooded area susceptibility mapping, this study applied and verified probability model and the frequency ratio using a geographic information system (GIS) and frequency raio. Flooded areas were identified in the study area of field surveys, and maps of the topography, geology, landcover and green infrastructure were constructed for a spatial database. The factors that influence flooded areas occurrence, such as slope gradient, slope, aspect and curvature of topography and distance from darinage, were calculated from the topographic database. Lithology and distance from fault were extracted and calculated from the geology database. The frequency ratio coefficient is overlaid for flooded areas susceptibility mapping as each factor's ratings. Then the flooded areas susceptibility map was verified and compared using the existing flooded areas. As the verification results, the frequency ratio model showed 82% in prediction accuracy. The method can be used to reduce hazards associated with flooded areas and to plan land use.

Computational Treatment for Plotting of the Planar and the Linear Structures in Fault Zone (단층대내(斷層帶內)의 면(面) 및 선구조(線構造)의 도식화(圖式化)를 위한 전산처리(電算處理))

  • Sunwoo, Choon;Lee, Byung-Joo
    • Economic and Environmental Geology
    • /
    • v.23 no.3
    • /
    • pp.359-366
    • /
    • 1990
  • Field sampling requires statistical description to draw inferences from data. Field data, or linear structures, are commonly analyzed by the graphical presentations, such as streonets and rose diagrams. For this purpose the DROPOL program is developed to analyze the data more efficiently with personal computer. DROPOL program written in FORTRAN 77 plots the structural data in points, poles or great circle on equalarea (Schmidt net) or equal-angle (Wulff net) projection surface. It is also capable to project the data from upper or lower hemisphere of stereonet and to draw pole contour diagrams from the plotted data. The rose diagram, representing the frequency of the strike and dip angle, can also be drawn in general or smooth type using $5^{\circ}$ or $10^{\circ}$ degrees interval.

  • PDF

Design of the Ground Resistance Measuring System to the Earth-Noise

  • Jung Min-Jae;Joo Hyung-Jun;Lee Ki-Hong;Oh Sung-Up;Jung Jae-Ki;Seong Se-Jin
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.566-570
    • /
    • 2001
  • Generally, grounding systems are responsible for the safe operation of a power system. Their performance guarantees equipment protection and personnel safety under condition of the limited ground potential rise and touch voltages as well as step voltages under ground fault conditions. Therefore, it is necessary to measure the ground resistance frequently for checking the performance of grounding system, In this paper the ground resistance measuring system using digital signal processor and high-performance L-C resonant band pass filter is presented. The signal current magnitude for measuring ground resistance in this system is $10^{-1}[A]\;to\;5\times10^{-2}[A]$ and the current frequency is 30[Hz].

  • PDF

Design of incident signal of time-frequency domain reflectometry in application to detect fault in a XLPE cable (XLPE 전력 케이블 결함 진단을 위한 시간-주파수 영역 반사파 계측법 기준신호 설계)

  • Jang, Seung-Jin;Lee, Sin-Ho;Lee, Chun-Ku;Park, Jin-Bae
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1870-1871
    • /
    • 2011
  • 본 논문에서는 전력케이블에서의 시간-주파수 영역 반사파 계측법을 기반으로 한 기준신호를 설계한다. 사용된 기준신호는 시간과 주파수 영역에서 동시에 분석할 수 있는 가우시안 포락선을 가지는 첩 신호이다. 10m 전력케이블의 특성에 적합하게 설계된 기준신호를 케이블에 직접 인가하여 반사파를 측정하고 정규화된 시간-주파수 영역 상호상관함수로 비교 분석하였다.

  • PDF

A Study on Excitation System for Synchronous Generator using Current Mode Controlled PWM Converter (전류제어형 PWM컨버터를 이용한 동기발전기용 여자시스템에 관한연구)

  • 장수진;류동균;서민성;김준호;원충연;배기훈
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.151-156
    • /
    • 2002
  • The output voltage of Synchronous Generator is regulated constantly by field current control in excitation system. A synchronous generator is equipped with an automatic voltage regulator(AVR), which is responsible for keeping the constant output voltage under normal operating conditions about various levels. High frequency PWM converter (Current Mode Control Buck converter) type excitation system for synchronous generator is able to sustain output voltage level properly when the fault condition happened. This paper deals with the design and evaluation of the excitation system controller for a synchronous generator to improve the steady state and transient stability. The simulation and experimental results show that the proposed excitation system is improve the respons time by the AVR(automatic voltage regulator) of 50kW synchronous generator that is applied the current mode control excitation system.

  • PDF