• Title/Summary/Keyword: Fault Diagnosis and Isolation

Search Result 75, Processing Time 0.023 seconds

Performance Evaluation Involving Multiple Parameters in Built-In-Test Systems

  • Kang, Hee-Jung;Yoo, Wang-Jin
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.16 no.2
    • /
    • pp.148-158
    • /
    • 1991
  • The Built-In-Test (BIT) system is an integrated subsystem for the determination of the health status of any primary system. The BIT consists of hardware and software installations directed at performance of the functions of fault detection, diagnosis and isolation, as well as primary system record failure information. Evaluation of the difinitions appropriate to the BIT system, including system characteristics and parameters, is important to an understanding of system functions. The object of this paper is to present general definitions of the BIT diagnosis parameters and a semiquantiative evaluation method for BIT systems. Finally, two case studies for actual problem solutions are included.

  • PDF

A Novel Equalization Method of Multiple Transceivers of Multiple Input Multiple Output Antenna for Beam-farming and the Estimation of Direction of Arrival (빔조향 및 전파도래각 추정을 위한 새로운 다중입력 다중출력 안테나 송수신부 구성방법)

  • 이성종;이종환;염경환;윤찬의
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.13 no.3
    • /
    • pp.288-300
    • /
    • 2002
  • In this paper, a novel method of equalization of RF transceivers is suggested for MIMO(Multiple Input Multiple Output) antenna actively studied for high speed data transmission in the recent IMT-2000 system. The core of suggestion is in equalizing the transfer characteristics of multiple transceivers using feedback and memory during the predefined calibration time. This makes it possible to weight the signals in the intermediate frequency, which is easier in the application of recently developed DoA(Direction of Arrival) algorithms. In addition, the time varying optimum cell formation according to traffic is feasible by antenna beam-forming based on the DoA information. The suggested method of equalizing multiple transceivers are successfully verified using envelope simulation. two outputs. This paper is concerned with the diagnosis of multiple crosstalk-faults in OSM. As the network size becomes larger in these days, the convent.nal diagnosis methods based on tests and simulation be.me inefficient, or even more impractical. We propose a simple and easily implementable alg?ithm for detection and isolation of the multiple crosstalk-faults in OSM. Specifically, we develop an algorithm for isolation of the source fault in switc.ng elements whenever the multiple crosstalk-faults are.etected in OSM. The proposed algorithm is illustrated by an example of 16$\times$16 OSM.

Vibration Signal Analysis of Running Electric Train using Adaptive Signal Processing (적응신호처리에 의한 주행전기동차의 진동신호해석)

  • 최연선;이봉현
    • Proceedings of the KSR Conference
    • /
    • 1999.05a
    • /
    • pp.143-150
    • /
    • 1999
  • The vibration signals of driving parts of electric train are distorted its signal patterns due to the impact components, which occurs when wheel passes rail joints. An elimination method of the impact components is investigated using adaptive signal processing technique in this study. The result shows that adaptive interference canceling method seems to be more effective than line enhancement technique. The application of adaptive interference canceling method to the signal measured at bogie shows that the extractions of the signals of driving parts of traction motor, reduction gear, and axle bearing are successful. Therefore, only the signals of bogie, which is the place to attach an accelerometer easily, is sufficient for the fault diagnosis and the safety evaluation of electric train. Also, adaptive interference canceling method can be applicable to evaluate the performance of vibration isolation between bogie and car body and to investigate the characteristics of indoor sound.

  • PDF

Design on Fult Diagnosis System based on Dynamic Fuzzy Model (동적포지모델기반 고장진단 시스템의 설계)

  • 배상욱
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.10 no.2
    • /
    • pp.94-102
    • /
    • 2000
  • This paper presents a new FDI scheme based on dynamic fuzzy model(DFM) for the unknown nonlinear system, which can detect and isolate process faults continuously over all ranges of operating condition. The dynamic behavior of a nonlinear process is represented by a set of local linear models. The parameters of the DFM are identified by an on-line methods. The residual vector of the FDI system is consisted of the parameter deviations from nominal model and the set of grade of membership values indicating the operating condition of the nonlinear process. The detection and isolation of faults are performed via a neural network classifier that are learned the relationship between the residual vector and fault type. We apply the proposed FDI scheme to the FDI system design for a two-tank system and show the usefulness of the proposed scheme.

  • PDF

Built-In-Test Coverage Analysis Considering Failure Mode of Electronics Components (전자부품 고장모드를 고려한 Built-In-Test 성능분석)

  • Seo, Joon-Ho;Ko, Jin-Young;Park, Han-Joon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.43 no.5
    • /
    • pp.449-455
    • /
    • 2015
  • Built-In-Test(hereafter: BIT) is necessary functionality for aircraft flight safety and it requires a high failure detection capacity of more than 95 % in the case of avionics equipment. The BIT coverage analysis is needed to make sure that BIT meets its fault diagnosis capability. FMECA is used a lot of for the BIT coverage analysis. However, in this paper, the BIT coverage analysis based on electronic components is introduced to minimize the analytical error. Further, by applying the failure mode of the electronic components and excluding electronic components that do not affect flight safety, the BIT coverage analysis can be more accurate. Finally, BIT demo was performed and it was confirmed that the performance of the actual BIT matches the analysis of BIT performance.