• 제목/요약/키워드: Fault Detection and Isolation(FDI)

검색결과 77건 처리시간 0.024초

특이치 분해를 이용한 중복 센서의 EDI 기법과 성능 분석 (Fault Detection and Isolation using Singular Value Decomposition for Redundant Sensors System)

  • 심덕선;양철관
    • 제어로봇시스템학회논문지
    • /
    • 제10권4호
    • /
    • pp.364-370
    • /
    • 2004
  • In this paper, we propose a FDI method, which comes from singular value decomposition of measurement matrix fur redundant sensors. We analyze the performance of the proposed FDI method by comparing with the GLT method in two ways such as FDI performance and GN&C performance. Also, we propose a GN&C performance index by combining FDI and GN&C performance.

퍼지로직을 이용한 항공기 고장 검출 및 분리 (A Study on Actuator Fault Detection and Isolation in Airplanes using Fuzzy Logic)

  • 이장호;김유단
    • 한국군사과학기술학회지
    • /
    • 제7권3호
    • /
    • pp.140-148
    • /
    • 2004
  • Fault detection and isolation(FDI) and reconfigurable flight control system provide better survivability even though actuator faults occur. In this study, a new fault detection and isolation algorithm is proposed using fuzzy logic. When the FDI system detects the actuator fault, the fuzzy logic investigates the state variables to find which actuator has fault. Proposed fuzzy detection algorithm detect not only a single fault but also multiple faults. After detecting the fault, the reconfigurable flight control system begins operating for compensating the effects of the fault. A numerical simulation using six degree-of-freedom nonlinear aircraft model is performed to verity the performance of the proposed fault detection and isolation scheme.

Simultaneous Fault Isolation of Redundant Inertial Sensors based on the Reduced-Order Parity Vectors

  • Yang, Cheol-Kwan;Shim, Duk-Sun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.2188-2191
    • /
    • 2005
  • We consider a fault detection and isolation problem for inertial navigation systems which use redundant inertial sensors. We propose a FDI method using average of multiple parity vectors which reduce false alarm and wrong isolation, and improve correct isolation. We suggest the number of redundant sensors required to isolate simultaneous faults. The performance of the proposed FDI algorithm is analyzed by Monte-Carlo simulation.

  • PDF

무인기 관성측정 센서의 비모델 복합 고장진단기법 (Model-Free Hybrid Fault Detection and Isolation For UAV Inertial Measurement Sensors)

  • 김승균;김유단
    • 제어로봇시스템학회논문지
    • /
    • 제11권3호
    • /
    • pp.200-206
    • /
    • 2005
  • In this paper, a redundancy management system for aircraft is studied, and FDI (Fault Detection and Isolation) algorithm of inertial sensor system is proposed. UAV system cannot allow triple or quadruple hardware redundancy due to the limitations on space and weight. In the UAV system with dual sensors, it is very difficult to identify the faulty sensor. Also, conventional FDI method cannot isolate multiple faults in a triple redundancy system. In this paper, hardware based FDI technique is proposed, which combines a parity equation approach with the wavelet based technique, which is a model-free FDI method. To verify the effectiveness of the proposed FDI method, numerical simulations are performed.

이산시간 상태지연 시스템을 위한 ℋ_/ℋ 고장검출 및 분리 (ℋ_/ℋ Fault Detection and Isolation for Discrete-Time Delayed Systems)

  • 지성철;이호재
    • 제어로봇시스템학회논문지
    • /
    • 제17권10호
    • /
    • pp.960-966
    • /
    • 2011
  • In this paper, an $\mathfrak{H}$_/$\mathfrak{H}_{\infty}$ fault detection and isolation (FDI) observer design problem is investigated for discrete-time delayed systems. To that end, a bank consisting of the sensor's number of observers is introduced. Each residual should be sensitive to a certain partial group of faults, but robust against the disturbance as far as possible. We formulate this multiobjective FDI problem as $\mathfrak{H}$_/$\mathfrak{H}_{\infty}$ observers design problem. Sufficient design condition is expressed as iterative linear matrix inequalities. The fault is then detected and isolated by evaluating the residuals through an FDI decision logic. A computer simulation is provided for verification of the proposed technique.

역진자 제어계의 고장검출식별 기법 (Fault Detection and Isolation Scheme for Inverted Pendulum Control System)

  • 이상문;류지수;이기상;박태건
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 D
    • /
    • pp.2227-2229
    • /
    • 2004
  • Fault Detection and Isolation(FDI) schemes using unknown input functional observers with very low order are presented. These schemes resolve the major practical difficulties with all FDI systems employing multiple observers for residual generation and can be implemented by the use of microprocessors that are normally used in commercial processes mainly due to the simplicity of the residual generation block. Various design objectives including detection, isolation, estimation and compensation of instrument fault/or process fault are achievable with these schemes. The proposed FDI scheme is applied to an inverted pendulum control system for instrument fault detection.

  • PDF

Performance Comparison of GPS Fault Detection and Isolation via Pseudorange Prediction Model based Test Statistics

  • Yoo, Jang-Sik;Ahn, Jong-Sun;Lee, Young-Jae;Sung, Sang-Kyung
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권5호
    • /
    • pp.797-806
    • /
    • 2012
  • Fault detection and isolation (FDI) algorithms provide fault monitoring methods in GPS measurement to isolate abnormal signals from the GPS satellites or the acquired signal in receiver. In order to monitor the occurred faults, FDI generates test statistics and decides the case that is beyond a designed threshold as a fault. For such problem of fault detection and isolation, this paper presents and evaluates position domain integrity monitoring methods by formulating various pseudorange prediction methods and investigating the resulting test statistics. In particular, precise measurements like carrier phase and Doppler rate are employed under the assumption of fault free carrier signal. The presented position domain algorithm contains the following process; first a common pseudorange prediction formula is defined with the proposed variations in pseudorange differential update. Next, a threshold computation is proposed with the test statistics distribution considering the elevation angle. Then, by examining the test statistics, fault detection and isolation is done for each satellite channel. To verify the performance, simulations using the presented fault detection methods are done for an ideal and real fault case, respectively.

Speed and Current Sensor Fault Detection and Isolation Based on Adaptive Observers for IM Drives

  • Yu, Yong;Wang, Ziyuan;Xu, Dianguo;Zhou, Tao;Xu, Rong
    • Journal of Power Electronics
    • /
    • 제14권5호
    • /
    • pp.967-979
    • /
    • 2014
  • This paper focuses on speed and current sensor fault detection and isolation (FDI) for induction motor (IM) drives. A new, accurate and high-efficiency FDI approach is proposed so that a system can continue operating with good performance even in the presence of speed sensor faults, current sensor faults or both. The proposed three paralleled adaptive observers are capable of current sensor fault detection and localization. By using observers, the rotor flux and rotor speed can be estimated which allows the system to run under the speed sensorless vector control mode when a speed sensor fault occurs. In order to detect speed sensor faults, a threshold-based scheme is proposed. To verify the feasibility and effectiveness of the proposed FDI strategy, experiments are carried out under different conditions based on a dSPACE DS1104 induction motor drive platform.

선형시스템의 모델기반 고장감지와 분류 (Model-based fault detection and isolation of a linear system)

  • 이인수;전기준
    • 전자공학회논문지S
    • /
    • 제35S권1호
    • /
    • pp.68-79
    • /
    • 1998
  • In this paper, we propose a model-based FDI(fault detetion and isolation) algorithm to detect and isolate fault in a linear system. The proposed algorithm is gased on an HFC(hydrid fault classifier) which consists of an FCART2(fault classifier by ART2 neural network) and an FCFM(fault classifier by fault models) which operate in parallel to isolate faults. The proposed algorithm is functionally composed of three main parts-parameter estimation, fault detection, and isolation. When a change in the system occurs, the estimated parameters go through a transition zone in which errors between the system output and the stimated output and the estimated output cross a predetermined thrseshold, and in this zone the estimated parameters are tranferred to the FCART2 for fault isolation. On the other hand, once a fault in the system is detected, the FCFM statistically isolates the fault by using the error between ach fault model out put and the system output. From the computer simulation resutls, it is verified that the proposed model-based FDI algorithm can be performed successfully to detect and isolate faults in a position control system of a DC motor.

  • PDF

2 자유도 동조자이로 직교배치에 대한 고장검출기법 연구 (Study of Fault Detection Method for Two-Degree of Freedom Dynamically Tuned Gyros on Orthogonal Configuration)

  • 김정용;오준석;노웅래
    • 항공우주기술
    • /
    • 제6권2호
    • /
    • pp.150-156
    • /
    • 2007
  • 본 논문에서는 2축 자유도를 갖는 동조자이로 3개가 직교배치를 이루고 있는 관성항법 장치의 관성센서 고장검출기법에 대해 다루었다. 특히 동조자이로 고장특성을 고려하여 동조자이로 입력 축에 대한 고장 판단보다는 자이로 단위의 고장 판단을 수행하였으며, 보다 신뢰성 있는 고장 판단을 위해 검출할 고장 크기에 따른 개별 고장검출 모듈을 설정하였다. 큰 고장 감지는 현재 순간의 관성센서 정보만을 이용하는 방법을 이용하여 짧은 시간내에 고장판단이 가능하도록 하였으며, 작은 고장감지는 과거부터 현재까지 누적된 정보를 순차적으로 사용하여 고장판단에 소요되는 시간은 다소 길지만 보다 신뢰성 있는 고장정보를 제공하도록 하였다. 동조자이로 고장특성 및 고장 크기에 따른 개별 고장검출 모듈을 통해 성공적인 관성센서 고장검출이 가능함을 확인할 수 있었다.

  • PDF