• Title/Summary/Keyword: Fault Analysis

검색결과 2,756건 처리시간 0.036초

Bi-directional fault analysis of evaporator inspection system

  • Kang, Dae-Ki;Kang, Jeong-Jin
    • International journal of advanced smart convergence
    • /
    • 제1권1호
    • /
    • pp.57-60
    • /
    • 2012
  • In this paper, we have performed a safety analysis on an automotive evaporator inspection system. We performed the bi-directional analysis on the manufacturing line. Software Fault Tree Analysis (SFTA) as backward analysis and Software Failure Modes, Effects, & Criticality Analysis (SFMECA) as forward analysis are performed alternately to detect potential cause-to-effect relations. The analysis results indicate the possibility of searching and summarizing fault patterns for future reusability.

Fault Tree Analysis을 활용한 집진기(Bag Filter) 고장의 체계적 분석 (A System Approach to A Bag Filter Failure using Fault Tree Analysis)

  • 이근희;이동형
    • 산업경영시스템학회지
    • /
    • 제12권20호
    • /
    • pp.1-24
    • /
    • 1989
  • This paper takes aim at the reliability evaluation by application of Fault Tree Analysis and its computerization. FTA is one of the methods for evaluation of system reliability and safety analysis. The important characteristic of this paper is that computer program is written in the package program(dBaseIII+) by 16Bit/AT personal computer. The program consists of three program segments. (1) The minimal cut sets of the system fault tree are obtained by means of "Fault tree reduction algorithm" (2) The minimal path sets are obtained by inversion of the minimal cut sets determined from fault tree (3) The importance of the basic events which are presented in the minimal cut sets is obtained by means of structural importance analysis. In this paper, a Fault Tree Analysis is applied to a BAG FILTER which is a kind of dust collector.collector.

  • PDF

FT구축 및 평가를 위한 FTA방법의 일반적 고찰(I) (A Review of FTA Methods for FT Construction & Evaluation(I))

  • 박주식;김길동;강경식;박상민
    • 대한안전경영과학회지
    • /
    • 제2권3호
    • /
    • pp.13-25
    • /
    • 2000
  • This paper reviews and classify fault-tree analysis methods developed since 1960 for system safety and reliability. Fault-tree analysis is a useful analytic tool for the reliability and safety of complex systems. The literature on fault-tree analysis is, for the most part, scattered through conference proceedings and company reports. This paper classify the literature according to system definition, fault-tree construction, qualitative evaluation, quantitative evaluation, and available computer codes for fault-tree analysis.

  • PDF

4단자망을 아용한 고장계산에 관한 연구 (Short-Circuit Calculation Using Tow-Port Network)

  • 김주용;이재용;백영식
    • 대한전기학회논문지
    • /
    • 제43권4호
    • /
    • pp.533-542
    • /
    • 1994
  • This paper presents the new algorithm for fault analysis and this algorithm obtains requisite term for fault analysis by the two-port network technique. Therefore, the fault calculation time is composed of only few fundamental arithmetic calculation. The graphic user environment for fault analysis is implemented in mouse-oriented user interface with window and pull-down menu. The result of the algorithm proved to be identical with the sample system in Ref.[8]. this package can be a useful tool for fault analysis.

기능 전개 결과를 이용한 Function Tree 구성에 관한 연구 (A Study on the Construction of Function Tree using Function Deployment)

  • 하성도;이언경;박선주;강달모
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2000년도 추계학술대회 논문집
    • /
    • pp.401-406
    • /
    • 2000
  • Fault tree analysis (FTA) is a widely used methodology for reliability analysis. The method is useful in that it suggests a very comprehensive way of describing the hierarchical relations of causes of faults and the corresponding results. However it is difficult to get appropriate fault trees for given products or systems without very profound knowledge and experience. This work aims to develop a methodology of fault tree construction using the results of function deployment for machine parts, which provides an objective way of preparing fault trees. The failure modes are defined to each function network generated by the function deployment method and the fault tree with respect to each viewpoint is constructed by arranging the failure modes. The fault tree is finally obtained by synthesizing the fault trees with respect to each viewpoint. The example of fault tree construction is also shown.

  • PDF

지중송전케이블 고장신호 처리를 위한 필터 설계 (Filter Design for Fault Location Detection on Underground Power Cable)

  • 이재덕;류희석;최상봉;남기영;정성환;김대경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.361-363
    • /
    • 2003
  • To reduce the effect of fault on underground power cable, we need exact and fast fault location detection technique. In this thesis, we describe on filter design technique that can be applied to on-line fault defection technique. To design fitter for fault location defection on Power cable, we should analysis fault signal. So we designed test bed for fault generation and measured fault signals for analysis. Through the analysis of signals, we found that ANC filter can be applied to separate fault signals and we designed a ANC filter. We tested on the designed filter through computer simulation, and we describe its results in this paper.

  • PDF

교류전기철도 보호특성 해석 및 고장점표정 시뮬레이션 (The Analysis of Protection -Characteristics and Fault-Locator Simulation on the Electrical Railway)

  • 창상훈;이장무
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 1998년도 추계학술대회 논문집
    • /
    • pp.262-269
    • /
    • 1998
  • In case the fault occurs in AC power supply network, protective relaying system must selectively detect line-to-line/ground fault and immediately cut off the power flow into the fault location for guaranteeing the safety of people, electric vehicle and ground installation etc. It is the most important point in power system operation to minimize the fault duration by rapid trip scheme and accurate estimation of the fault location. In this paper, we analyze the load characteristics of each vehicle, perform the fault analysis of AC power supply network using AT current-ratio method. The result shows its usefulness.

  • PDF

Wavelet 변환을 이용한 고저항 지락사고 고장점 추정 (Fault Location Estimation for High Impedance Fault using Wavelet Transform)

  • 김현;김철환
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제49권8호
    • /
    • pp.369-373
    • /
    • 2000
  • High impedance fault(HIF) is defined as a fault that the general overcurrent relay can not detect or interrupt. Especially when HIF occurs in residential areas, energized high voltage conductor results in fire hazard, equipment damage or personal threat. This paper proposes a fault location estimation algorithm for high impedance fault using wavelet transform. The algorithm is based on the wavelet analysis of the fault voltage and current signals. The performance of the proposed algorithm is tested on a typical 154kV korean transmission line system under various fault conditions. From the tests presented in this paper it can be concluded that a fault location estimation algorithm using wavelet transform can precisely calculate the fault point for HIF.

  • PDF

Analysis on Current Limiting Characteristics of Transformer Type SFCL with Additionally Coupled Circuit

  • Lim, Seung-Taek;Ko, Seok-Cheol;Lim, Sung-Hun
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권2호
    • /
    • pp.533-539
    • /
    • 2018
  • In this paper, the transformer type superconducting fault current limiter (SFCL) with additionally coupled circuit was suggested and its peak fault current limiting characteristics due to the fault condition to affect the fault current were analyzed through the fault current limiting tests. The suggested transformer type SFCL is basically identical to the previous transformer type SFCL except for the additional coupled circuit. The additional coupled circuit, which consists of the magnetically coupled winding to the primary and the secondary windings together with another superconducting element and is connected in parallel with the secondary winding of the transformer type SFCL, is contributed to the peak fault current limiting operation for the larger transient fault current directly after the fault occurrence. To confirm the fault current limiting operation of the suggested SFCL, the fault current limiting tests of the suggested SFCL were performed and its effective peak fault current limiting characteristics were analyzed through the analysis on the electrical equivalent circuit.

HVAC 시스템의 중복고장 검출을 위한 실험적 연구 (An Experimental Study on Multi-Fault Detection and Diagnosis Analysis of HVAC System)

  • 조성환;홍영주;양훈철;안병천
    • 설비공학논문집
    • /
    • 제16권10호
    • /
    • pp.932-941
    • /
    • 2004
  • The objective of this study is to detect the multi-fault of HVAC system using a new pattern classification technique. To classify the effect of single-fault in determining the pattern, supply air temperature, OA-damper, supply fan, and air flowrate were chosen as experimental parameters. The combination of supply temperature, flow rate, supply fan and OA-damper were chosen as multi-fault conditions. Three kinds of patterns were introduced in the analysis of multi-fault problem. To solve multi-fault problem, the new pattern classification technique using residual ratio analysis was introduced to detect the multi-fault as well as single-fault. The residual ratio could diagnose single-fault or multi-fault into several patterns.