• Title/Summary/Keyword: Fatigue load

Search Result 1,495, Processing Time 0.029 seconds

HIGH HEAT FLUX TEST WITH HIP BONDED 35X35X3 BE/CU MOCKUPS FOR THE ITER BLANKET FIRST WALL

  • Lee, Dong-Won;Bae, Young-Dug;Kim, Suk-Kwon;Jung, Hyun-Kyu;Park, Jeong-Yong;Jeong, Yong-Hwan;Choi, Byung-Kwon;Kim, Byoung-Yoon
    • Nuclear Engineering and Technology
    • /
    • v.42 no.6
    • /
    • pp.662-669
    • /
    • 2010
  • To develop the manufacturing methods for the blanket first wall (FW) of the International Thermonuclear Experimental Reactor (ITER) and to verify the integrity of the joint, Be/Cu mockups were fabricated and tested at the KoHLT-1 (Korea Heat Load Test facility), a graphite heater facility located at the Korea Atomic Energy Research Institute (KAERI). Since Be and Cu joining is the focus of the present study, the fabricated mockups had a CuCrZr heat sink joined with three Be tiles as an armor material, unlike the original ITER blanket FW, which has a stainless steel structure and coolant tubes. Hot isostatic pressing (HIP) was carried out at $580^{\circ}C$ and 100 MPa for 2 hours as the method for Be/Cu joining. Three interlayers, namely, $1{\mu}mCr/10{\mu}mCu$, $1{\mu}mTi/0.5{\mu}mCr/10{\mu}mCu$, and $5{\mu}mTi/10{\mu}mCu$ were applied as a coating to the Be tiles by a physical vapor deposition (PVD) method. A shear test was performed with the specimens, which were fabricated by the same methods as those used to fabricate the mockups. The average values were 125 MPa to 180 MPa, and the samples with the $1{\mu}mCr/10{\mu}mCu$ interlayer showed the lowest value. No defect or delamination was found in the joints of the mockups by the developed ultrasonic test using a flat-type probe with a 10 MHz frequency and a 0.25 inch diameter. High heat flux (HHF) tests were performed at $1.0\;MW/m^2$ heat flux for each mockup using the given conditions, and the results were analyzed by ANSYS-CFX code. For the test criteria, an expected fatigue lifetime about 1,000 cycles was obtained by analysis with ANSYS-mechanical code. Mockups using the interlayers of $1{\mu}mTi/0.5{\mu}mCr/10{\mu}mCu$ and $5{\mu}mTi/10{\mu}mCu$ survived up to 1,100 cycles over the required number of cycles. However, one of the Be tiles in the other two mockups using the $1{\mu}mCr/10{\mu}mCu$ interlayer was detached during the screening test, and others were detached by discharge after 862 cycles. The integrity of the joints using the proposed interlayers was proven by the HHF test, but the other interlayer requires more study before it can be used for the joining of Be to Cu. Moreover, it was confirmed that the measured temperatures agreed well with the analysis temperatures, which were used to estimate the lifetime and that the developed facility showed its capability of the long time operation.

Comparison of Kinematics and Myoelectrical Activity during Deadlift, with and without Variable Banded Resistance, in Healthy, Trained Athletes

  • Everett B. Lohman;Mansoor Alameri;Fulden Cakir;Chih Chieh Chia;Maxine Shih;Owee Mulay;Kezia Marceline;Simran Jaisinghani;Gurinder Bains;Michael DeLeon;Noha Daher
    • Physical Therapy Rehabilitation Science
    • /
    • v.13 no.1
    • /
    • pp.53-70
    • /
    • 2024
  • Background: The conventional deadlift is a popular exercise for enhancing trunk, core, and lower extremity strength. However, its use in sports medicine is constrained by concerns of lumbar injuries, despite evidence supporting its safety and rehabilitative benefits. To optimize muscle activation using resistive bands in variable resistance therapy, we explored their feasibility in the deadlift. Design: Comparative experimental design Methods: Surface electromyography recorded muscle activity in the trunk and lower extremities during lifting, with normalization to the isometric Floor Lift using Maximal Voluntary Contraction. Kinematics were measured using inclinometer sensors to track hip and trunk sagittal plane angles. To prevent fatigue, each subject only used one of the three pairs of bands employed in the study. Results: Our study involved 45 healthy subjects (mean age: 30.4 ± 6.3 years) with similar baseline characteristics, except for years of lifting and strength-to-years-of-lifting ratio. Various resistance band groups exhibited significantly higher muscle activity than conventional deadlifts during different phases. The minimal resistance band group had notably higher muscle activity in the trunk, core, and lower extremity muscles, particularly in the end phase. The moderate resistance band group showed increased muscle activity in the mid-and end-phases. The maximum resistance band group demonstrated greater muscle activity in specific muscles during the early phase and overall higher activity in all trunk and lower extremity muscles in the mid and end phases of the deadlift (p<0.05). Conclusion: Our findings provide valuable insights into muscle activation with various resistance bands during deadlift exercise in clinical and gym settings. There appears to be a dose-response relationship between increased resistance bandwidth, external load, myoelectric activation, and range.

Wave Analysis and Spectrum Estimation for the Optimal Design of the Wave Energy Converter in the Hupo Coastal Sea (파력발전장치 설계를 위한후포 연안의 파랑 분석 및 스펙트럼 추정)

  • Kweon, Hyuck-Min;Cho, Hongyeon;Jeong, Weon-Mu
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.25 no.3
    • /
    • pp.147-153
    • /
    • 2013
  • There exist various types of the WEC (Wave Energy Converter), and among them, the point absorber is the most popularly investigated type. However, it is difficult to find examples of systematically measured data analysis for the design of the point absorber type of power buoy in the world. The study investigates the wave load acting on the point absorber type resonance power buoy wave energy extraction system proposed by Kweon et al. (2010). This study analyzes the time series spectra with respect to the three-year wave data (2002.05.01~2005.03.29) measured using the pressure type wave gage at the seaside of north breakwater of Hupo harbor located in the east coast of the Korean peninsula. From the analysis results, it could be deduced that monthly wave period and wave height variations were apparent and that monthly wave powers were unevenly distributed annually. The average wave steepness of the usual wave was 0.01, lower than that of the wind wave range of 0.02-0.04. The mode of the average wave period has the value of 5.31 sec, while mode of the wave height of the applicable period has the value of 0.29 m. The occurrence probability of the peak period is a bi-modal type, with a mode value between 4.47 sec and 6.78 sec. The design wave period can be selected from the above four values of 0.01, 5.31, 4.47, 6.78. About 95% of measured wave heights are below 1 m. Through this study, it was found that a resonance power buoy system is necessary in coastal areas with low wave energy and that the optimal design for overcoming the uneven monthly distribution of wave power is a major task in the development of a WEF (Wave Energy Farm). Finding it impossible to express the average spectrum of the usual wave in terms of the standard spectrum equation, this study proposes a new spectrum equation with three parameters, with which basic data for the prediction of the power production using wave power buoy and the fatigue analysis of the system can be given.

THE EFFECT OF CYCLIC LOADING ON THE RETENTIVE STRENGTH OF FULL VENEER CROWNS (반복 하중이 Full veneer crown의 유지력에 미치는 영향에 관한 연구)

  • Kim, Ki-Youn;Lee, Sun-Hyung;Chung, Hun-Young;Yang, Jae-Ho;Heo, Seong-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.5
    • /
    • pp.583-594
    • /
    • 2000
  • Dislodgement of a crown or extension bridge and the loosening of a retainer of a bridge is a serious clinical problem in fixed restoration. Generally these problems are considered to be associated with deformation of the restoration. During biting, the restoration is subjected to complex forces and deforms considerably within the limit of its elasticity. Deformation of the restoration under the occlusal force induces excessive stress in the cement film, which then leads to the cement fracture. Such a fracture may eventually cause loss of the restoration. Because most of the past retention tests for full veneer crown were done without fatigue loading, they were not exactly simulating intraoral environment. And the purpose of this study was to evaluate the effect of cyclic cantilever loading on the retentive strength of full veneer crowns depending on different type of cements and taper of prepared abutment. Steel dies with $8^{\circ}\;or\;16^{\circ}$ convergence angle were fabricated through milling and crowns with the same method. These dies and crowns were divided into 8 groups. Group 1 : $16^{\circ}$ taper die, cementation with zinc phosphate cement, without loading Group 2 : $16^{\circ}$ taper die, cementation with zinc phosphate cement, with loading Group 3 : $8^{\circ}$ taper die, cementation with zinc phosphate cement, without loading Group 4 : $8^{\circ}$ taper die, cementation with zinc phosphate cement, with loading Group 5 : $16^{\circ}$ taper die, cementation with Panavia 21, without loading Group 6 : $16^{\circ}$ taper die, cementation with Panavia 21, with loading Group 7 : $8^{\circ}$ taper die, cementation with Panavia 21 without loading Group 8 : $8^{\circ}$ taper die, cementation with Panavia 21, with loading After checking the fit of die and crown, the luting surface of dies and inner surface of crowns were air-abraded for 10 seconds. The crowns were cemented to the dies, with cements mixed according to the manufacturer's recommendations. A static load of 5kg was then applied for 10 minutes with static loading device. Twenty-four hours later, group 1, 3, 5, 7 were only thermocycled, group 2, 4, 6, 8 were subjected to cyclic loading after thermocycling. Retentive tests were performed on the Instron machine. From the finding of this study, the following conclusions were obtained 1. Panavia 21 showed significantly higher retentive strength than zinc phosphate cement for all groups (p<0.05). 2. There was a significant difference in the retentive strength between $8^{\circ}\;and\;16^{\circ}$ taper for zinc phosphate cement(p<0.05), but no significant difference for Panavia 21 (p>0.05). 3. Cyclic loading significantly decreased the retentive strength for all groups(p<0.05). 4. For zinc phosphate cement, there was 35% reduction of the retentive strength after loading in the $16^{\circ}$ taper die, 25% in the $8^{\circ}$ taper die, and for Panavia 21, 21% in the $16^{\circ}$ taper die, 18% in the $8^{\circ}$ taper die.

  • PDF

A Study on Job Stress and Eating Behavior and Habits of Dental Hygienists (치과위생사의 직무스트레스와 식행동 및 식습관에 관한 연구)

  • Koong, Hwa-Soo;Kim, Seong-Min
    • Journal of dental hygiene science
    • /
    • v.12 no.5
    • /
    • pp.525-534
    • /
    • 2012
  • Study the effect of stress factors and increases in stress at work on the changes in eating behavior and habits and the influence of these changes on the health of dental hygienists. Use the responses of 273 dental hygienists who work in or around the Seoul area after surveying them by post or face to face. The biggest reason for skipping breakfast was having no time (60.4%) and the most desired change in eating habits was over eating (33.0%) while 51.6% responded that they over ate or binge ate due to stress. The largest stress factor was work load 39.6% and subjects responded that after stress the amount of food consumed increased very much for 12.1%, very for 49.8%, indicating increased food consumption than usual. The group with the most job stress had a high level of self stress awareness (p<0.001), nervousness (p<0.01), back pains (p<0.001), optical fatigue (p<0.01), headache (p<0.01) and indigestion (p<0.01). The higher the job stress, the poorer the eating behavior was (p<0.01) and job stress was high for dental hygienists working in dental clinics with less than three dental hygienists (p<0.05). Low eating behavior scores could be seen in groups that took 4 night shifts per week (p<0.05). Job stress scores for high for groups with no break time during work (p<0.001) and these groups showed low eating behavior scores (p<0.01). Furthermore, if high levels of self stress awareness was present, job stress was very high (p<0.001) and eating behavior scores were the lowest (p<0.05). Job stress of dental hygienists impede the eating behavior and habits therefore has a negative influence on their health. There is a need for more efforts to solve this problem and thus maintain the health of dental hygienists.