• Title/Summary/Keyword: Fatigue Endurance

Search Result 210, Processing Time 0.036 seconds

Spectral Electromyographic Fatigue Analysis of Back Muscles in Healthy Adult Men and Women During Sorensen Test (근전도를 이용한 Sorensen 검사시 성인남녀 등 근육의 근피로도 분석)

  • Lee, Mi-Seon;Kim, Tae-Young
    • Physical Therapy Korea
    • /
    • v.5 no.3
    • /
    • pp.63-71
    • /
    • 1998
  • Trunk holding test (Sorensen test) appear to have more value than strength test in prediction the occurrence of low back pain. Electromyographic activity of trunk extensor muscles during these test may provide clues to the etiology of neuromuscular-based low back pain. This study investigated the difference in back muscle endurance between healthy adult men and women using surface electromyographic (EMG) power spectral analysis. Thirty hea1thy subjects (15 men and 15 women) performed an unsupported trunk holding test for 60 seconds. Recording surface electrodes were placed over the erector spinae medially and laterally at vertebral levels of $L_1$ and $L_5$. Slope of total frequency was evaluated using the MP100WSW Fast Fourier Transform spectrum analysis program. The slopes of all indices of back muscle fatigue, except right $L_5$, were significantly steeper in men than in women (p<0.05). Our results indicated that the trunk holding test using EMG power spectral analysis of erector spinae muscles is useful for the evaluation of fatigue rate of these muscles. Our results also showed a higher muscle endurance in healthy adult women than in men.

  • PDF

Effects of Acute Transcranial Direct Current Stimulation on Muscle Endurance of the Lower Extremities for Young Healthy Adults (일회성 경두개 직류전기자극(tDCS) 적용이 젊은 성인의 하지 근지구력에 미치는 영향)

  • Park, Shin-Young;Ko, Do-Kyung;Jeong, Hyeong Do;Lee, Hanall;Lee, Hyungwoo;Kim, Chanki;An, Seungho;Kim, Jiyoung;Moon, Bosung;Son, Jee-Soo;Lee, Dohyeon;Lee, Eui-Young;Lee, Ju Hak;Im, Seungbin;Tan, Yuan;Jeon, Kyoungkyu;Kang, Nyeonju
    • Korean Journal of Applied Biomechanics
    • /
    • v.32 no.3
    • /
    • pp.94-102
    • /
    • 2022
  • Objective: The purpose of this study was to investigate the effect of acute transcranial direct current stimulation (tDCS) on the isokinetic muscular endurance of the lower extremity for young adults. Method: Thirteen young adults performed isokinetic fatigue tasks for two experimental conditions including real tDCS and sham stimulation protocols. Before and after the task, the tensiomyography was used for evaluating muscle contraction characteristics of vastus medialis and semitendinosus. Paired t-test was performed to compare the fatigue index, changes in maximum radial displacement (∆Dm), delay time (∆Tc), and velocity of contraction (∆Vc) between tDCS conditions. Results: We found no significant differences in the fatigue index between real and sham conditions. In addition, the analyses identified no significant different values of ∆Dm, ∆Tc, and ∆Vc in the vastus medialis and semitendinosus between real and sham conditions. Conclusion: These findings suggest that the tDCS protocols may have no acute effect on lower limb muscle endurance for young adults. Future studies should consider the long-term effects of repetitive tDCS sessions, various stimulation positions, exercise tasks, and participant characteristics to more clearly understand the effect of tDCS on muscle endurance of lower extremities.

Fatigue Life Evaluation of the Plastic Gear (플라스틱 기어의 피로수명 평가 및 수명 예측)

  • Chong Tae Hyong;Kang Sung Kyu;Ha Young Wook
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.239-245
    • /
    • 2005
  • Through the fatigue test of plastic gears using polyacetal polymer, this research aims at providing basic data for not only specifying operation conditions of plastic gears, but also designing dimensions of plastic gears with giving fatigue life and the estimated equation of fatigue life of plastic gears. That is, from the fatigue life curves, the estimated equation of fatigue life of plastic gears is taken out. For the estimated equation of fatigue life of plastic gears, this research provides two test methods; one is preserving non-limited temperature of tooth flank, the other is preserving limited temperature of tooth flank. As results, how the temperature of tooth flank affects the fatigue life is shown. In addition, based on the endurance limit, the essential factors of the unit load and K-factor are determined, which are needed in the design of gear by bending strength and surface durability.

  • PDF

An Analysis of Fatigue Characteristics of Upper limbs by Task Conditions Change (작업조건의 변화에 따른 상지의 피로 특성 분석)

  • Lee, Sang-Do;Sim, Jeong-Hoon
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.28 no.3
    • /
    • pp.75-86
    • /
    • 2005
  • To investigate the fatigue characteristic of upper limbs, this study analyzed RMS(root mean square) and MPF(mean power frequency) value between initial and terminal stages of each experiment condition. And the effect of intermittent endurance time was evaluated using the Borg's CR10 value that was measured for the parts of upper limb. According to the results of ANOVA on RMS value, there were significant difference on the %MVC about push, pull, and down force exertion. Particularly the ANOVA of up force exertion was significant difference on shoulder flexion, elbow flexion and rest time as well as %MVC. The results of ANOVA for MPF value were significant difference on the %MVC in regard of the push and up force exertion. In case of up force exertion, MPF value tended to shift low frequency at all of the experiment conditions. According to the analysis of duty cycle, RMS value considerably increased over 50% duty cycle and as the %MVC increased, the duty cycle affected the increase of RMS value. MPF value for up and down force exertion decreased at 33%, 50% and 67% duty cycle for all of %MVC. Borg CR10 value of hand and forearm were below the 3-point to the 40% of endurance time at 30%MVC and to the 20% of endurance time at 50%MVC with the exception of up force exertion. But Borg CR10 values of upper arm and shoulder at up force exertion were more than 3-point to the 20% of endurance time at 30%MVC and in the start point of endurance time at 50%MVC.

Deterioration in strength of studs based on two-parameter fatigue failure criterion

  • Wang, Bing;Huang, Qiao;Liu, Xiaoling
    • Steel and Composite Structures
    • /
    • v.23 no.2
    • /
    • pp.239-250
    • /
    • 2017
  • In the concept of two-parameter fatigue failure criterion, the material fatigue failure is determined by the damage degree and the current stress level. Based on this viewpoint, a residual strength degradation model for stud shear connectors under fatigue loads is proposed in this study. First, existing residual strength degradation models and test data are summarized. Next, three series of 11 push-out specimen tests according to the standard push-out test method in Eurocode-4 are performed: the static strength test, the fatigue endurance test and the residual strength test. By introducing the "two-parameter fatigue failure criterion," a residual strength calculation model after cyclic loading is derived, considering the nonlinear fatigue damage and the current stress condition. The parameters are achieved by fitting the data from this study and some literature data. Finally, through verification using several literature reports, the results show that the model can better describe the strength degradation law of stud connectors.

Fatigue Durability Analysis and Evaluation for Straighted Type Exhaust System of Automobile (자동차용 직선화 배기시스템의 피로내구 해석 및 평가)

  • Park Sejong;Suh Hocheol
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.13 no.1
    • /
    • pp.147-152
    • /
    • 2005
  • The exhaust system of automobile is faced with random or spectrum types of fatigue loads during usage life and so needs to be closely estimated for quality and performance to have enough certainty on design endurance lift during preliminary design process. Structural operation conditions, operation load history, property of material and manufacturing process etc. should be considered by performing experiment approach. Using the software program for predicting fatigue life quickly and exactly in preliminary design stage saves plenty of time and cost generated by fatigue tests. In this paper, fatigue life prediction was performed on the basis of fatigue analysis using MSC/FATIGUE and load data from field test and the life of development items was estimated and compared through the results.

Static and Fatigue Analysis of Bogie Rotating Frame for Light Rail Train (경량전철 대차 선회프레임의 정적강도와 피로특성 분석)

  • 구정서;조현직;송달호
    • Proceedings of the KSR Conference
    • /
    • 2001.10a
    • /
    • pp.253-260
    • /
    • 2001
  • Rotating bogie frame will be used in the bogie for the Light Rail Train being developed. In development of the bogie, analyzed were the structural strength and fatigue characteristics of the rotating bogie frame. Defined load cases were applied for the analysis. No part of the rotating bogie frame is subjected to stress beyond the fatigue endurance limits of the material used when grinding the weldment of the lower plate link bend. It is concluded that the rotating bogie frame is considered safe in the view of the structural strength.

  • PDF

Relationship between Tensile Characteristics and Fatigue Failure by Folding or Bending in Cu Foil on Flexible Substrate (유연성 기판에 사용되는 전해 동박의 절곡 및 굴곡 피로 파괴와 인장 특성과의 관계)

  • Kim, Byoung-Joon;Jeong, Myeong-Hyeok;Hwang, Sung-Hwan;Lee, Ho-Young;Lee, Sung-Won;Cbun, Ki-Do;Park, Young-Bae;Joo, Young-Cbang
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.18 no.1
    • /
    • pp.55-59
    • /
    • 2011
  • Folding endurance, bending fatigue and monotonic tensile tests of 4 kinds of Cu foil on flexible substrate was performed to investigate the relationship between folding or bending endurances and tensile characteristics. The repeated 5.3 or 2.0% strain was applied to Cu foil in folding endurance test or bending fatigue test while monitoring the electrical resistance. Elastic modulus, yield strength, ultimate tensile strength, ductility, and toughness were obtained by monotonic tensile test on the same samples. The Cu foil with higher toughness and ductility showed higher reliabilities in folding or bending fatigue. However, elastic modulus and yield strength did not show any relationship with folding and bending reliability. This is because the failures of Cu foil by folding or bending fatigue were closely related to the fracture energy of metal.

EMG Power Spectral Analysis on Masticatory Muscle Fatigue in Chronic Muscle Pain Patients (근전도 power spectrum을 이용한 만성근육동통 환자에 있어서의 저작근 피로에 관한 연구)

  • 이채훈;김영구;임형순
    • Journal of Oral Medicine and Pain
    • /
    • v.22 no.1
    • /
    • pp.145-155
    • /
    • 1997
  • The purpose of this study was to compare differences in endurance time and EMG power spectral characteristics of the masticatory muscles during sustained isometric contraction between patients and controls. 15 CMD patients{8 women and 7 men, aged 15 to 38 years(24.1$\pm$7.5)}, and 15 healthy volunteers{8 women and 7 men, aged 15 to 30 years(24.7$\pm$3.4)} without past history or present symptoms of CMD were included in this study. Sustained isometric contractions of masticatory muscles were perfomeed as long as possible at 50% level of maximum voluntary contraction(MVC) of EMG activity via visual feedback, and the duration of sustained isometric contraction(endurance time) was examined. The author perfomed EMG power spectral analysis in the myoelectric signals of masseter and anterior temporal muscle during sustained isometric contraction in CMD patients with chronic muscle pain and healthy controls. The author came to following conclusions from the results. 1. The endurance time of the patient group was shorter than the control group in sustained isometric contraction of masticatory muscles(p<0.01). 2. MF values of masticatory muscles with sustained isometric contraction during endurance time were decreased following regression line in both groups(p<0.01, r>0.9). 3. The amount of MF shift to lower frequency range exhibited no significant differences between the patients and the control group in sustained isometric contraction during endurance time. 4. SMF to lower frequency range of the patient group was steeper than the control group in sustained isometric contraction during endurance time(p<0.05).

  • PDF

A Comparative Study on Mechanical Properties of Rail Pad Material (레일패드 소재의 물리적 특성에 관한 비교 연구)

  • Kwon Sung-Tae;Na Sung-Hoon;Kim Jung-Nam
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.510-515
    • /
    • 2004
  • In this study, we investigate the mechanical properties of rail pad material according to pad types. Especially, to study the application and endurance of TEEE material, we conducted experiments such as tension strength test, hardness test, fatigue test and wear test. Test results showed that TEEE material was better application and endurance than other pad material, but there was difficulties for comparing with others because the variations of application according to pad' types were variable.

  • PDF