• Title/Summary/Keyword: Fat Dipole

Search Result 9, Processing Time 0.032 seconds

A Study on Wideband LC Oscillator Using Fat Dipole Antenna (팻 다이폴 안테나를 이용한 광대역 LC 오실레이터에 관한 연구)

  • Lee, Sang-Heun;Yoon, Young-Joong;Heo, Hoon;Nam, Sang-Hoon;Lee, Woo-Sang;Choi, Do-Won
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.11
    • /
    • pp.1185-1192
    • /
    • 2008
  • In this paper, a wideband LC oscillator which is composed of a high voltage switch and a fat dipole antenna was designed and radiation characteristics are analyzed. A Marx generator was used as a high voltage pulse generator of the proposed wideband LC oscillator and $90^{\circ}$ corner reflector was used to obtain high directivity. According to simulated and measured results, 3 dB bandwidth of high voltage switch without fat dipole based on the received power is about 9%(${\lambda}_1=0.7\;m$) and bandwidth Is about 30%(${\lambda}_2=1\;m$) by using the LC oscillator containing high voltage switch and fat dipole. Consequently, fat dipole affects not only radiating power but also operating frequency and bandwidth of the LC oscillator. This study will be useful to determine operating frequency and radiating power when we design LC oscillator which uses a high voltage switch and a fat dipole.

Miniaturization of Ultra Wideband Log-Periodic Dipole Antenna for Leaked Electromagnetic Measurement (누설전자파 측정을 위한 초광대역 로그주기 안테나의 소형화)

  • Choi, Dong-Hoon;Kim, Tae-Hyung;Moon, Jun-Ho;Yook, Jong-Gwan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.10
    • /
    • pp.761-768
    • /
    • 2017
  • In this paper, to implement the electromagnetic wave environment and solve electromagnetic compatibility(EMC) problem, miniaturization of ultra-wide band log periodic dipole antenna for measurement was investigated. In addition, in oder to improve the signal-to-noise ratio in high frequency band, balun was connected to the antenna to stabilize the operation of the differential mode antenna and the single mode coaxial cable. To minimize the total size and to increase bandwidth of the antenna, a fat dipole structure was used for the resonance frequency band below 4 GHz and a general dipole shape was used for that above 4 GHz. The bandwidth of the proposed antenna was represented from 0.6 GHz to 8.0 GHz with a ratio bandwidth of 12.3 : 1. Measured peak gain varies from 5.7 dBi to 9.1 dBi, and a half power beamwidth was presented from $29.4^{\circ}$ to $100.2^{\circ}$ in operating range.

Performance Verification and Improvement of UHF Sensor for the Increasement of the Partial Discharge Detection Reliability (부분방전검출 신뢰도 향상을 위한 UHF 센서개선 및 성능검증)

  • Kim, Won-Gyu;Kim, Min-Soo;Baek, Young-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.10
    • /
    • pp.1461-1466
    • /
    • 2014
  • GIS(Gas Insulated Switchgear) is important power apparatus which have strong dielectric strength, supply electric power and is a part of the power system. Most substation type is configured as GIS. Recently, because of continuous increasement of GIS demand resulted from high quality & big capacity of electric power, the necessity of the preventive & diagnosis system is being expanded gradually. GIS partial discharge occurred on the UHF band is detected effectively by the method to IEC 60270 that recommend to be able to detect the apparent minimum discharge, 5 pC. Additionally, the UHF sensor should be installed to detect PD signal if Partial discharge signal, 5 pC occur in every part of GIS. Currently PD diagnosis system applying UHF sensor for GIS with various voltage level like 154 kV, 345 kV, 765 kV have been operated. And it is necessary to measure and analyze insulation breakdown phenomenon of inside GIS exactly. In this paper, we proposed Fat-dipole patch UHF sensor that is developed and more sensitive, excellent wide-range characteristic than the exising UHF sensor. And we performed KERI (Korea Electrotechnology Research Institute) reference test, which showed the excellent result for the all tests.

Influence of lossy ground on impulse propagation in time domain for impulse ground penetrating radar (초광대역 임펄스 지반탐사레이더에서 지면의 영향에 따른 임펄스 전파 특성 연구)

  • Kim, Kwan-Ho;Park, Young-Jin;Yoon, Young-Joong
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.44 no.11
    • /
    • pp.42-47
    • /
    • 2007
  • In this paper, influence of lossy ground and gap variation between lossy ground and UWB antenna on impulse propagation in time domain for impulse ground penetrating radar (GPR) is numerically and experimentally investigated. For this study, a novel planar UWB fat dipole antenna is developed. First, influence of lossy ground and gap variation between lossy ground and UWB antenna is simulated. For verification, a test field of sand and wet clay soil is built and using the developed dipole antenna, transmission behavior is investigated at the test field. With an aid of IDFT (inverse discrete Fourier transform), time domain impulse response for transmission coefficient measured and simulated in frequency domain is obtained. Measurement and simulation show that the frequency of maximum transmission coefficient and transmission coefficient are increased with higher dielectric constant and larger gap distance. In time domain, it is shown that for higher dielectric constant, the amplitude of the received signal in time domain is higher and reflected signals are seriously modified. Also, it is found that variation of gap between antenna and ground surface makes timing of peak value changed.

Comparison of the characteristics related to the structure of external-type UHF UWB PD sensors for GIS (GIS용 외장형 광대역 극초단파 부분방전 센서의 구조에 따른 특성 비교)

  • Hwang, Chul-Min;Koo, Ja-Yoon;Park, Ki-Jun;Koo, Sun-Geun;Yoon, Jin-Yul;Lee, Young-Sang
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1769-1771
    • /
    • 2004
  • 가스절연 개폐장치(GIS)용 극초단파 부분 방전 측정장치에 다양하게 사용 할 수 있는 외장형 부분 방전 (PD) 센서를 제작하였다. Fat-dipole, 대수주기(log-periodic), spiral 및 log-spiral 형 패치안테나를 이용한 외장형 PD 센서의 주파수 특성과 검출감도를 기본 Dipole형 센서와 비교하였다. 제작된 센서는 170kV 단상 GIS의 스페이서에 장착하여 5 pC PD에 대한 각 센서의 주파수 특성과 감도를 측정 하였다.

  • PDF

A Study for the Fault Location of Insulation Defects considering Waveguide Characteristics in GIS (GIS의 도파관 특성을 고려한 절연결함 위치판정에 관한 연구)

  • Lee, Seung-Chul;Jung, Seung-Yong;Lee, Jae-Ho;Koo, Ja-Yoon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.2
    • /
    • pp.252-255
    • /
    • 2008
  • A study for discharge pattern analysis partial and fault location by use of UHF sensors in GIS. However, in the latter case, the results considered the velocity of EM waves modified by the waveguide characteristics of GIS bus bar were not reported yet. In this paper, UHF wide band sensor to detect partial discharge signals have been designed and manufactured to get the widest band characteristic by an application of Fat-Dipole UHF antenna and the result that the transmission velocity of EM waves is 2/3 of the light have been got through the consideration of waveguide characteristics. Also, to verify applicability on site of the developed method, self-designed external type UHF sensor have been installed on operating GIS in Korea Midland Power co. and detected location of the fault. Through the fault have been found at the location, the reliability of the developed method have been proved.

A study for the fault location of insulation defects considering waveguide characteristics in GIS (GIS의 도파관 특성을 고려한 절연결함 위치판정에 관한 연구)

  • Kim, Young-Hong;Lee, Young-Jo;Jeong, Sung-Yong;Ryu, Cheol-Hwi;Lee, Jeon-Seon;Koo, Ja-Yoon
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1434-1435
    • /
    • 2007
  • UHF 센서를 사용한 GIS의 절연결함 패턴분석 및 위치판독에 대한 많은 연구가 이루어지고 있으나, 후자의 경우 GIS Bus bar의 형태에 의한 전자파의 전달속도를 고려한 결과들은 아직 보고된바 없다. 본 논문은 이러한 관점에서 부분방전 신호검출용 광대역 센서를 Fat-Dipole를 변형시켜 가장 넓은 대역을 얻도록 설계 제작하였으며, GIS Bus bar 내에서 발생하는 부분방전 신호의 전달 속도 계산결과 이론치의 약 2/3 정도였다. 또한 개발된 방법의 현장적용 가능성을 확인하기 위하여 자체 설계 제작한 외장형 UHF 센서를 중부발전소에서 운전중인 GIS에 부착하여 절연결함 위치를 추정 후 해체 작업을 통하여 확인한 결과 추정된 위치에서 결함이 발견되어 개발된 방법의 신뢰성을 입증하였다.

  • PDF

Quantitative Analysis of Magnetization Transfer by Phase Sensitive Method in Knee Disorder (무릎 이상에 대한 자화전이 위상감각에 의한 정량분석법)

  • Yoon, Moon-Hyun;Sung, Mi-Sook;Yin, Chang-Sik;Lee, Heung-Kyu;Choe, Bo-Young
    • Investigative Magnetic Resonance Imaging
    • /
    • v.10 no.2
    • /
    • pp.98-107
    • /
    • 2006
  • Magnetization Transfer (MT) imaging generates contrast dependent on the phenomenon of magnetization exchange between free water proton and restricted proton in macromolecules. In biological materials in knee, MT or cross-relaxation is commonly modeled using two spin pools identified by their different T2 relaxation times. Two models for cross-relaxation emphasize the role of proton chemical exchange between protons of water and exchangeable protons on macromolecules, as well as through dipole-dipole interaction between the water and macromolecule protons. The most essential tool in medical image manipulation is the ability to adjust the contrast and intensity. Thus, it is desirable to adjust the contrast and intensity of an image interactively in the real time. The proton density (PD) and T2-weighted SE MR images allow the depiction of knee structures and can demonstrate defects and gross morphologic changes. The PD- and T2-weighted images also show the cartilage internal pathology due to the more intermediate signal of the knee joint in these sequences. Suppression of fat extends the dynamic range of tissue contrast, removes chemical shift artifacts, and decreases motion-related ghost artifacts. Like fat saturation, phase sensitive methods are also based on the difference in precession frequencies of water and fat. In this study, phase sensitive methods look at the phase difference that is accumulated in time as a result of Larmor frequency differences rather than using this difference directly. Although how MT work was given with clinical evidence that leads to quantitative model for MT in tissues, the mathematical formalism used to describe the MT effect applies to explaining to evaluate knee disorder, such as anterior cruciate ligament (ACL) tear and meniscal tear. Calculation of the effect of the effect of the MT saturation is given in the magnetization transfer ratio (MTR) which is a quantitative measure of the relative decrease in signal intensity due to the MT pulse.

  • PDF

A Study on the Lens Amplifier for Wideband Spatial Power Combining (광대역 공간 전력 합성을 위한 렌즈 증폭기에 관한 연구)

  • Kwon Oh-Sun;Kwon Se-Woong;Lee Byoung-Moo;Yoon Young-Joong
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.5 s.108
    • /
    • pp.483-489
    • /
    • 2006
  • In this paper, new wideband lens amplifiers are proposed for C-band wireless communication service. In order to obtain the wideband property, all components of the proposed lens amplifiers are designed with balanced structure and wideband characteristics. Fat dipole antenna as the input and output antenna, balanced amplifier as amplifying components, and coplanar stripline(CPS) as the delay line fer the beam focusing are used fur composing the stable wideband lens amplifier. The $5{\times}5$ 2D lens amplifier has the characteristics that the absolute gain is 7.5 dB, the EIPG is 37.4 dB at 6 GHz, and the 3-dB gain bandwidth is 19.8 %.