• 제목/요약/키워드: Fast magnetic resonance imaging (MRI)

검색결과 84건 처리시간 0.02초

THE CURRENT STATUS OF BIOMEDICAL ENGINEERING IN THE USA

  • Webster, John G.
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1992년도 춘계학술대회
    • /
    • pp.27-47
    • /
    • 1992
  • Engineers have developed new instruments that aid in diagnosis and therapy Ultrasonic imaging has provided a nondamaging method of imaging internal organs. A complex transducer emits ultrasonic waves at many angles and reconstructs a map of internal anatomy and also velocities of blood in vessels. Fast computed tomography permits reconstruction of the 3-dimensional anatomy and perfusion of the heart at 20-Hz rates. Positron emission tomography uses certain isotopes that produce positrons that react with electrons to simultaneously emit two gamma rays in opposite directions. It locates the region of origin by using a ring of discrete scintillation detectors, each in electronic coincidence with an opposing detector. In magnetic resonance imaging, the patient is placed in a very strong magnetic field. The precessing of the hydrogen atoms is perturbed by an interrogating field to yield two-dimensional images of soft tissue having exceptional clarity. As an alternative to radiology image processing, film archiving, and retrieval, picture archiving and communication systems (PACS) are being implemented. Images from computed radiography, magnetic resonance imaging (MRI), nuclear medicine, and ultrasound are digitized, transmitted, and stored in computers for retrieval at distributed work stations. In electrical impedance tomography, electrodes are placed around the thorax. 50-kHz current is injected between two electrodes and voltages are measured on all other electrodes. A computer processes the data to yield an image of the resistivity of a 2-dimensional slice of the thorax. During fetal monitoring, a corkscrew electrode is screwed into the fetal scalp to measure the fetal electrocardiogram. Correlations with uterine contractions yield information on the status of the fetus during delivery To measure cardiac output by thermodilution, cold saline is injected into the right atrium. A thermistor in the right pulmonary artery yields temperature measurements, from which we can calculate cardiac output. In impedance cardiography, we measure the changes in electrical impedance as the heart ejects blood into the arteries. Motion artifacts are large, so signal averaging is useful during monitoring. An intraarterial blood gas monitoring system permits monitoring in real time. Light is sent down optical fibers inserted into the radial artery, where it is absorbed by dyes, which reemit the light at a different wavelength. The emitted light travels up optical fibers where an external instrument determines O2, CO2, and pH. Therapeutic devices include the electrosurgical unit. A high-frequency electric arc is drawn between the knife and the tissue. The arc cuts and the heat coagulates, thus preventing blood loss. Hyperthermia has demonstrated antitumor effects in patients in whom all conventional modes of therapy have failed. Methods of raising tumor temperature include focused ultrasound, radio-frequency power through needles, or microwaves. When the heart stops pumping, we use the defibrillator to restore normal pumping. A brief, high-current pulse through the heart synchronizes all cardiac fibers to restore normal rhythm. When the cardiac rhythm is too slow, we implant the cardiac pacemaker. An electrode within the heart stimulates the cardiac muscle to contract at the normal rate. When the cardiac valves are narrowed or leak, we implant an artificial valve. Silicone rubber and Teflon are used for biocompatibility. Artificial hearts powered by pneumatic hoses have been implanted in humans. However, the quality of life gradually degrades, and death ensues. When kidney stones develop, lithotripsy is used. A spark creates a pressure wave, which is focused on the stone and fragments it. The pieces pass out normally. When kidneys fail, the blood is cleansed during hemodialysis. Urea passes through a porous membrane to a dialysate bath to lower its concentration in the blood. The blind are able to read by scanning the Optacon with their fingertips. A camera scans letters and converts them to an array of vibrating pins. The deaf are able to hear using a cochlear implant. A microphone detects sound and divides it into frequency bands. 22 electrodes within the cochlea stimulate the acoustic the acoustic nerve to provide sound patterns. For those who have lost muscle function in the limbs, researchers are implanting electrodes to stimulate the muscle. Sensors in the legs and arms feed back signals to a computer that coordinates the stimulators to provide limb motion. For those with high spinal cord injury, a puff and sip switch can control a computer and permit the disabled person operate the computer and communicate with the outside world.

  • PDF

연골성 분화를 보이는 화생성 유방암의 영상의학적 소견: 증례 보고 (Imaging Findings of Metaplastic Breast Carcinoma with Chondroid Differentiation: A Case Reports)

  • 김지영;김성희;정명자;이지혜;강미진;곽금희;유수현
    • 대한영상의학회지
    • /
    • 제83권6호
    • /
    • pp.1385-1393
    • /
    • 2022
  • 화생성 유방암은 상피성 암과 다양한 화생성 변화가 혼합된 형태의 암으로, 드물게 발생하나, 높은 재발률과 전이율을 보이는 공격적 성향을 가진 암이다. 연골성 분화를 보이는 화생성 암은 화생성 유방암의 아형 중에서도 상대적으로 드물게 발생하며, 다른 아형에 비해 비교적 좋은 예후를 보인다. 저자들은 연골성 분화를 보이는 화생성 유방암으로 진단된 3명의 환자의 영상의학적 소견을 다음과 같이 보고한다. 유방촬영상 무정형 또는 거친 불균질한 석회화를 동반한 고밀도 종괴를 보이고 초음파상 미세소엽형 또는 불분명한 경계를 가진 복합성 낭성 및 고형성 종괴(complex cystic and solid mass)로 보인다. 자기공명영상에서 비교적 경계가 분명한 또는 부분적으로 경계가 불분명한 종괴로, T2 강조영상에서 비균질한 고신 호강도를 보이고, 빠른 초기 조영증강 및 말기 세척형의 신호강도 감소를 동반한 비균질한 조영증강이나 가장자리 조영증강을 보인다.

B-values 변환 자기공명영상: 국소 직장암 수술 전 검출을 위한 적합한 b-value 유용성 (Usefulness of High-B-value Diffusion - Weighted MR Imaging for the Pre-operative Detection of Rectal Cancers)

  • 이재승;구은회;이선엽;박철수;최지원
    • 한국콘텐츠학회논문지
    • /
    • 제9권12호
    • /
    • pp.683-690
    • /
    • 2009
  • 본 연구의 목적은 직장암 국소병변의 수술 전 검출을 위한 고 확산경사계수(High-b-values) 자기공명영상의 유용성을 평가하고자 한다. 직장암의 진단을 위하여 확산강조 자기공명영상을 시행한 60명의 환자 중 연령분포는 38 - 78세(평균 60세)였고 남자 40명, 여자가 20명 이었다. 사용된 장비는 1.5 Tesla 자기공명 영상기기(GE, General Electric Medical System, Excite HD)로 사용하였고, 검사 프로토콜은 고속기법 T2, T1강조영상을 얻은 후 정확한 병변 검출을 위하여 같은 위치를 정하여 확산강조영상을 얻었다. 확산강조영상의 b-value$(s/mm^2)$값은 250, 500, 750, 1000, 1500, 2000까지 변화시키면서 얻었다. 영상평가는 정량적 분석방법으로 직장, 방광과 종양간 대조도대 잡음비(rectum, bladder to tumor contrast noise ratio, 이하 CNR)를 GE software Functool tool을 사용하여 비교분석 하였고. 정성적 분석방법은 영상내의 인공물의 유무, 병변의 명확성, 직장벽 구분을 기준으로 네 명의 경험 있는 영상의학과 의사와 세 명의 방사선사가 영상을 분석하였다. 영상의 유의성 평가는 각 b-values 값에 대하여 ANOVA 검증과 Freedman 검증을 이용하여 분석하였다(p<0.05). 정량적 분석결과는 b-values 값 중 1000에서 직장, 종양의 평균 대조도대잡음비는 27.21, 24.44로 가장 높았고(p<0.05), 이때 확산계수는 $0.73\times10^{-3}$이었다. 정성적 분석결과로서, 병변의 명확성과 직장벽 구분은 $4.0\pm0.14$, $4.4\pm0.16$로 1000 값에서 가장 높았으며, 인공물유무는 $4.8\pm0.25$로 2000 값에서 높은 결과 이었다(p<0.05). 결론적으로, 확산강조영상은 수술 전 직장암 환자의 병변 검출에 유용성 있는 정보를 제공해 주었으며, 정확한 종괴의 발견을 위해는 고 확산경사계수 값 1000 영상이 가장 우수한 확산경사계수 값 이었다.

뇌의 고속스핀에코 T2강조영상에서 지방조직 억제를 위한 SPAIR의 반전시간(TI) 결정 및 STIR 영상과의 비교 연구 (Selection of TI for Suppression Fat Tissue of SPAIR and Comparative Study of SPAIR and STIR of Brain Fast SE T2 Weighted Imaging)

  • 이후민;김함겸;공석교
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제32권1호
    • /
    • pp.95-99
    • /
    • 2009
  • 본 연구는 뇌의 T2고속스핀에코 3.0T 자기공명영상에서 지방조직의 억제능력을 유지하면서 동시에 지방조직의 불균일성을 최소화할 수 있는 SPAIR의 적정 반전시간(TI)을 찾아보고, 지방억제기법인 STIR기법과도 비교하고자 한다. SPAIR 프로토콜의 반전시간(TI)은 SPAIR TR(420 msec)의 1/2, 1/3, 1/6, 1/12, 즉 210 msec(8명), 140 msec(26명), 70 msec(26명), 35 msec(18명)로 설정하고, STIR의 TI는 250 msec(26명)로 설정하여 뇌의 축방향 영상(104개)을 획득하였다. 출력영상의 지방조직, 근육조직, 백그라운드의 ROI($50\;mm^2$)를 설정하여 신호강도(SI)를 측정하였고, 지방과 근육조직과의 CNR을 산출하고, 지방조직에서 불균일치는 측정된 지방 신호의 평균치(mean)에 대한 표준편차(SD)로서 그 산출은 SD/mean으로 계산하였다. 측정결과는 첫째, SPAIR TI가 70 ms일 때, 지방조직의 신호강도가 TI가 140 ms 보다 낮게 측정되어 지방억제능력이 우수하였다. 둘째, SPAIR TI가 140 ms일 때, 영상의 질 측면에서 지방조직의 불균일치는 70 ms 보다 낮아서 영상의 질은 우수하게 나타났다. 따라서 SPAIR TI의 선택은 TR(420 ms)의 1/3인 140 ms와 1/6인 70 ms에서 결정되어야 하는데 지방조직의 억제능력과 지방조직의 불균일치에서 각각 통계적으로 유의한 차이(p < .001)를 보여 화질 측면에서 TI : 140 ms를 선택하는 것이 바람직하다고 생각한다. 한편, SPAIR(TI : 140 ms)와 STIR의 비교는 지방억제는 통계적으로 유의한 차이가 없으나(p < .252), 화질 측면에서 SPAIR가 STIR보다 우수한 결과를 보였고, 통계적으로 유의한 차이를 보였다(p < .01).

  • PDF