• Title/Summary/Keyword: Fast magnetic resonance imaging

Search Result 142, Processing Time 0.028 seconds

Advances in Fast Vessel-Wall Magnetic Resonance Imaging Using High-Density Coil Arrays

  • Yin, Xuetong;Li, Nan;Jia, Sen;Zhang, Xiaoliang;Li, Ye
    • Investigative Magnetic Resonance Imaging
    • /
    • v.25 no.4
    • /
    • pp.229-251
    • /
    • 2021
  • Arteriosclerosis is the leading cause of stroke, with a fatality rate surpassing that of ischemic heart disease. High-resolution vessel wall magnetic resonance imaging is generally recognized as a non-invasive and panoramic method for the evaluation of arterial plaque; however, this method requires improved signal-to-noise ratio and scanning speed. Recent advances in high-density head and neck coil arrays are characterized by broad coverage, multiple channels, and closefitting designs. This review analyzes fast magnetic resonance imaging from the perspective of accelerated algorithms for vessel wall imaging and demonstrates the need for effective algorithms for signal acquisition using advanced radiofrequency system. We summarize different phased-array structures under various experimental objectives and equipment conditions, introduce current research results, and propose prospective research studies in the future.

Gradient Waveform Synthesizer in Magnetic Resonance Imaging System using Digital Signal Processors (DSP를 이용한 자기공명영상시스템의 경사자계 파형 발생기)

  • Go, Gwang-Hyeok;Gwon, Ui-Seok;Kim, Chi-Yeong;Kim, Hyu-Jeong;Kim, Sang-Muk;An, Chang-Beom
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.49 no.1
    • /
    • pp.48-53
    • /
    • 2000
  • In this paper, we develop a TMS320C31 (60MHz) digital signal processor (DSP) board to synthesize gradient waveforms for Spiral Scan Imaging (SSI), which is one of the ultra fast magnetic resonance imaging (MRI) methods widely used. In SSI, accurate gradient waveforms are very essential to high quality magnetic resonance images. For this purpose, sampling rate for synthesizing the gradient waveforms is set twice as high as the data sampling rate. With the developed DSP boards accurate gradient waveforms are obtained. Ultra fast spiral scan imaging with the developed with the developed DSP board is currently under development.

  • PDF

DEMO: Deep MR Parametric Mapping with Unsupervised Multi-Tasking Framework

  • Cheng, Jing;Liu, Yuanyuan;Zhu, Yanjie;Liang, Dong
    • Investigative Magnetic Resonance Imaging
    • /
    • v.25 no.4
    • /
    • pp.300-312
    • /
    • 2021
  • Compressed sensing (CS) has been investigated in magnetic resonance (MR) parametric mapping to reduce scan time. However, the relatively long reconstruction time restricts its widespread applications in the clinic. Recently, deep learning-based methods have shown great potential in accelerating reconstruction time and improving imaging quality in fast MR imaging, although their adaptation to parametric mapping is still in an early stage. In this paper, we proposed a novel deep learning-based framework DEMO for fast and robust MR parametric mapping. Different from current deep learning-based methods, DEMO trains the network in an unsupervised way, which is more practical given that it is difficult to acquire large fully sampled training data of parametric-weighted images. Specifically, a CS-based loss function is used in DEMO to avoid the necessity of using fully sampled k-space data as the label, thus making it an unsupervised learning approach. DEMO reconstructs parametric weighted images and generates a parametric map simultaneously by unrolling an interaction approach in conventional fast MR parametric mapping, which enables multi-tasking learning. Experimental results showed promising performance of the proposed DEMO framework in quantitative MR T1ρ mapping.

The Ability of Muscle Functional MRI to Detect the Slight Effect of Exercise on Trunk Muscle Activity

  • Tawara, Noriyuki
    • Investigative Magnetic Resonance Imaging
    • /
    • v.26 no.2
    • /
    • pp.117-124
    • /
    • 2022
  • Purpose: In this study, we provide a way to assess even a slight effect of exercise on trunk-muscle activity. Materials and Methods: Seven healthy male participants (mean age, 24.7 ± 3.2 years; height, 171.2 ± 9.8 cm; and weight, 63.8 ± 11.9 kg) performed 15 sets of an exercise with 20 repetitions of 90° hip and right-knee flexion while lying supine. The exercise intensity was measured using the 10-point Rating of Perceived Exertion Scale after the first and 15th sets of exercises. Although cross-sectional areas and functional T2 mapping using ultrafast imaging (fast-acquired muscle functional magnetic resonance imaging, fast-mfMRI) have been proposed for imaging to evaluate exercise-induced muscle activity in real time, no previous studies have reported on the evaluation of trunk-muscle activity using functional T2 mapping. As a method for assessing trunk-muscle activity, we compared functional T2 mapping using ultrafast imaging (fast-mfMRI) with cross-sectional areas. Results: Although the muscle cross-sectional areas were increased by the exercise, there was no significant difference at rest. On the other hand, for all sets, the changes in T2 were significant compared with those at rest (P < 0.01). These results demonstrate that T2, calculated from fast-mfMRI images can be used to detect even a small amount of muscle activity induced by acute exercise, which was impossible to do with cross-sectional areas. Conclusion: Fast-mfMRI, which can also display functional information with detailed forms, enabled non-invasive real-time imaging for identifying and evaluating the degree of deep trunk-muscle activity induced by exercise.

Improvement of Gibb's Phenomena in Fast Spin Echo Imaging Using Symmetric Echo Arrangement and Filtering (대칭적 에코 배치 및 필터링을 통한 Fast Spin Echo 영상에서의 Gibb's 현상 개선)

  • 안창범;김치영;오창현;신진교
    • Investigative Magnetic Resonance Imaging
    • /
    • v.1 no.1
    • /
    • pp.79-85
    • /
    • 1997
  • Fast spin echo imaging utilizes multiple spin echoes to encode multiple k-space lines instead of multiple $T_2-weighted$ images. As results, intensities in k-space data are varying according to T2 decay, which generates Gibb's artifact in the reconstructed image. The echo time for e encoding dc block determines contrast, as is specified by the effective echo time, however, all location of other echoes to different k-space frequency blocks in fast spin echo imaging is not f fully investigated. In this study, symmetric arrangement of multiple echoes in k-space is investigated to reduce Gibb's artifact. Design of filters based on the measurement of multiple e echo intensities is also proposed in two stage manner, i.e., equalization and filtering. From s simulation and experiment, it was observed that Gibb's phenomena were substantially reduced b by the proposed methods.

  • PDF

MAGNETIC RESONANCE IMAGING APPEARANCE OF EPIDURAL HEMATOMA IN DOG (개의 경막외 혈종의 자기공명영상학적 진단)

  • Choi, Chi-Bong;Kim, Hwi-Yool;Kim, Su-Gwan;Bae, Chun-Sik
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.27 no.5
    • /
    • pp.488-491
    • /
    • 2005
  • A 3-year-old female, 5kg, Shih-tzu developed an acute onset of depression, disorientation, hypersalivation, nystagmus after falling down 2 meter height place. In plain skull radiography, there was fracture line in the frontal and parietal bones and next day magnetic resonance imaging examination was performed. Magnetic resonance imaging of the brain was performed with 3.0 Tesla unit. Under general anesthesia, the dog was placed in prone with its head positioned in a birdcage coil. Transverse, sagittal and coronal fast spin echo images of the brain were obtained with the following pulse sequences: T1 weighted images (TR = 560 ms and TE = 18.6 ms) and T2 weighted images (TR = 3500 ms and TE = 80 ms). Magnetic resonance imaging showed epidural hematoma in the left frontal area resulting in compression of the adjacent brain parenchyma. Left lateral ventricle was compressed secondarily and the longitudinal fissure shifted to the right, representing mass effect. The lesion was iso-to slightly hyperintense on T1 weighted image and iso-slightly hypointense signal on T2 weighted image. At necropsy, there was a skull fracture and epidural hematoma in the left frontal area. Magnetic resonance imaging of epidural hematoma is reviewed.

Fast MRI in Acute Ischemic Stroke: Applications of MRI Acceleration Techniques for MR-Based Comprehensive Stroke Imaging

  • You, Sung-Hye;Kim, Byungjun;Kim, Bo Kyu;Park, Sang Eun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.25 no.2
    • /
    • pp.81-92
    • /
    • 2021
  • The role of neuroimaging in patients with acute ischemic stroke has been gradually increasing. The ultimate goal of stroke imaging is to make a streamlined imaging workflow for safe and efficient treatment based on optimized patient selection. In the era of multimodal comprehensive imaging in strokes, imaging based on computed tomography (CT) has been preferred for use in acute ischemic stroke, because, despite the unique strengths of magnetic resonance imaging (MRI), MRI has a longer scan duration than does CT-based imaging. However, recent improvements, such as multicoil technology and novel MRI acceleration techniques, including parallel imaging, simultaneous multi-section imaging, and compressed sensing, highlight the potential of comprehensive MR-based imaging for strokes. In this review, we discuss the role of stroke imaging in acute ischemic stroke management, as well as the strengths and limitations of MR-based imaging. Given these concepts, we review the current MR acceleration techniques that could be applied to stroke imaging and provide an overview of the previous research on each essential sequence: diffusion-weighted imaging, gradient-echo, fluid-attenuated inversion recovery, contrast-enhanced MR angiography, and MR perfusion imaging.

SSFP Interferometry (SSFPI) Technique Applied to functional MRI - A Fast and Direct Measurement of Magnetic Susceptibility Effect (SSFPI 기법을 이용한 MR 뇌기능 영상 -고 속의 자화율 효과의 직접적인 측정)

  • 정준영
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.4
    • /
    • pp.525-534
    • /
    • 1996
  • We have developed a fast steady state free precession interferometry (SSFPI) technique which is useful for the fMRl (functional Magnetic Resonance Imaging). As is known, SSFP sequence with a suitable adjustment of Vadient (readeut) allows us to measure precession angle 6 which in tw relates to the field inhomogeneity. Combining the two pulses (known as FID and Echo) in FADE (Fast Acquisition Double Echo) sequence, for example, one can obtain the interference term which is directly related to the precession angle It has been known that a fast high resolution magnetic field mapping is possible by use of the modified FADE sequence or SSFPI, and we have attempted to use the SSFPI technique for the susceptibility-induced fMRl. When the method is applied to the susceptibility effect based functional magnetic resonance imaging (fMRl), it was found that the direct susceptibility effect measurement was possible without perturbations such as the backgrounds and inflow effect. In this paper, simulation results and experimental results obtained with 2.0 Tesla MRI system are presented.

  • PDF

Fast Burt Imaging (고속 Burst 영상법 - pulse sequence 중심으로)

  • 강호경;노용만
    • Investigative Magnetic Resonance Imaging
    • /
    • v.3 no.1
    • /
    • pp.13-19
    • /
    • 1999
  • MRI imaging provides many benefits such as noninvasive, 3-dimensional imaging capabilities. But it has relatively serious drawback that is the long data collection time, compared with other imaging modality. Many studies have been performed for fast MR imaging. But EPI and SEPI (4-6) are required to expensive hardware. In this paper, we introduce to Burst imaging technique. It can reduce imaging time by use of a mulitple RF excitation technique. Further it is easily implemented to the normal MRI system. But a pixel profile in the conventional burst sequence is so poor that excited area by burst sequence is a small portion of a pixel. This causes poor signal to noise ratio in burst image. therefore frequency sweeping of RF pulse for burst imaging sequence is proposed to improve pixel profile. A burst pulse train is shaped by liner or nonlinear frequency sweeping function so that all the spins within a pixel are excited, thereby improving the signal to noise ratio. It also shows that the pixel profiles are dependent on how frequency sweep is made. Computer simulations with Bloch equation and experimental results obtained using a 1.0 T NMR imaging system are presented.

  • PDF