• 제목/요약/키워드: Fast imaging

검색결과 458건 처리시간 0.027초

레이져 용접을 위한 고속 용접선 추적 알고리즘 (A Fast Seam Tracking Algorithm for Laser Welding)

  • 배재욱
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1997년도 한국자동제어학술회의논문집; 한국전력공사 서울연수원; 17-18 Oct. 1997
    • /
    • pp.52-55
    • /
    • 1997
  • This paper discusses an automatic visual-servoing system, in which a laser and a CCD camera are used for imaging the pattern of joint groove. The algorithm used here is simple and robust to find out the gap width and gap center. As a consequence, the speed of algorithm is very fast and optimized. A feature of this system is that it processes only by summing the vertical line and horizontal line of screen without any image preprocessing in order to get the energy information of lines alternatively. It is practical and useful for the system requiring a fast process time of vision.

  • PDF

고속 컴퓨터 집적 영상 복원 방법을 이용한 비선형 3D 영상 상관기 (Nonlinear 3D Image Correlator Using Fast Computational Integral Imaging Reconstruction Method)

  • 신동학;이준재
    • 한국정보통신학회논문지
    • /
    • 제16권10호
    • /
    • pp.2280-2286
    • /
    • 2012
  • 본 논문에서는 고속 컴퓨터 집적 영상 복원 방법을 이용하여 새로운 형태의 3D 비선형 상관기를 제안한다. 고속 컴퓨터 집적 영상 복원 방법을 구현하기 위해서 기존의 방법에서 확대 과정을 제거함으로서 고속 계산이 가능하다. 제안하는 상관기는 먼저 기준 물체와 목표 물체의 요소 영상들을 렌즈 배열을 통해 픽업한다. 이 픽업된 영상에 고속 컴퓨터 집적 영상 복원 방법을 사용하여 목표 평면 영상과 기준 평면 영상들이 복원된다. 복원된 기준 평면 영상과 목표 평면 영상들 간의 비선형 상호상관을 통해 인식을 수행한다. 비선형 상관 연산의 사용은 상관기의 3D 물체 인식 성능 향상시킬 수 있다. 제안된 방법의 유용함을 보이기 위해 기존의 방법과 비교하여 기초적인 상관관계 실험을 수행하고 그 결과를 보고한다.

3T 자기공명영상 장비에서 신생아 뇌의 T1 강조 영상: 스핀에코, 고속 역전회복, 자기화 삼차원 경사에코기법의 비교 (T1-weighted MR Imaging of the Neonatal Brain at 3.0 Tesla: Comparison of Spin Echo, Fast Inversion Recovery, and Magnetization-prepared Three Dimensional Gradient Echo Techniques)

  • 정지영;유소영;장경미;어홍;이정희;김지혜
    • Investigative Magnetic Resonance Imaging
    • /
    • 제11권2호
    • /
    • pp.87-94
    • /
    • 2007
  • 목적: 3T 장비의 신생아 뇌자기공명영상에서 T1 강조 고속 역전회복기법 (fast inversion recovery, FIR)과 자기화 삼차원 경사에코기법, (magnetization-prepared three dimensional gradient echo sequence, 3D GRE)을 스핀에코기법 (SE)과 비교하여 유용성을 알아보는 데 있다. 대상 및 방법: 20명의 신생아에서 T1 강조 SE, FIR, 그리고 3D GRE의 신호소음비 (SNR)와 대조소음비 (CNR)를 측정하고 시각적으로 회백질-백질 구별, 수초화 인식, 인공음영 발생을 점수화하여 비교하였다. 각 영상기법의 CNR 비교에는 Wilcoxon signed ranked test를 사용하였다. 결과: 세가지 영상기법 중 3D GRE가 가장 우수한 SNR을 보였고 CNR은 FIR과 3D GRE 모두 SE보다 우수하였으며 FIR보다 3D GRE가 더 우수하였다. 회백질-백질의 구분과 수초화 유무 역시 스핀에코보다 FIR과 3D GRE에서 더 잘 보였다. 그러나 3D GRE는 움직임에 의한 인공음영이 많았고 FIR에서 혈류에 의한 혈관의 고신호강도가 자주 발견되었다. 결론: 3T 장비에서 신생아 뇌영상을 얻을 때 FIR과 3D GRE 기법은 SE보다 좋은 T1 강조영상을 제공할 것으로 기대된다.

  • PDF

직결장암 조직의 자기공명영상과 초음파 소견에 대한 비교 연구 (In Vitro imaging of MRI and Ultrasound for Colorectal Carcinoma)

  • 이황규;지금난;홍수진;고재향
    • Investigative Magnetic Resonance Imaging
    • /
    • 제17권2호
    • /
    • pp.133-143
    • /
    • 2013
  • 목적 : 직결장암 조직의 자기공명영상과 고주파 초음파검사를 시행한 후 종양의 탐지와 침윤 깊이에 대해 각각의 영상 소견과 병리 소견을 비교하여 진단적 정확도를 두 영상 기기 간 비교하고, 자기공명영상의 경우 종양의 침윤 깊이를 주변 정상 조직과 가장 명확히 보여주는 펄스 연쇄 (pulse sequence)에 대해 알아보았다. 대상 및 방법 : 직결장암으로 절제술을 시행한 45명의 환자에서 얻은 45예의 제거된 종양 조직을 수조에 넣고 생리 식염수에 담가서 고주파수 (5-17 MHz)의 선형 탐촉자를 이용하여 초음파영상을 얻었으며 8-channel 두경부 코일에 넣어 자기공명영상을 얻었다. 이 연구에 대하여 기관감사위원회의 공지에 입각한 동의는 면제되었다. 자기공명영상은 정- 및 탈위상 경사에코 T1 강조영상, 급속스핀에코 T2 강조영상 및 이의 지방억제 영상, fast imaging employing steady-state acquisition (FIESTA)와 이의 지방억제영상, 확산강조영상 등 일곱 가지 펄스 연쇄를 시행하였다. 각 조직의 자기공명영상과 초음파영상 소견을 각각 독립적으로 종양의 탐지와 침윤 깊이에 대하여 두 명의 영상의학과 의사가 합의 하에 평가하였고 각각의 영상 소견을 병리 조직 소견과 비교하여 두 영상 기기 간 진단적 정확도를 비교하였다. 자기공명영상의 일곱 가지 펄스 연쇄 중에 종양의 침윤 깊이를 주변 정상 조직과 구분하여 명확히 보여주는 펄스 연쇄에 대해 알아보았다. 결과 : 직결장암 조직의 종양 탐지와 침윤 깊이를 평가하는데 있어 자기공명영상과 초음파의 진단적 정확도는 각각 91.1%와 86.7%로 높게 나타났다. 조기 직결장암의 경우 초음파 검사의 정확도는 87.5%, 자기공명영상 검사의 정확도는 75.0%로 나왔다. 두 영상 기기 간에 통계적으로 유의한 차이는 없었다 (p > 0.05). MR의 펄스 연쇄 중에 종양의 침윤 깊이를 주변 정상 조직과 구분하여 명확하게 보여주는 영상은 직결장암 및 조기 직결장암 모두 급속 스핀에코 T2 강조영상이었다. 결론 : 자기공명영상과 초음파 검사는 직결장암 조직의 종양 탐지와 침윤 깊이를 평가하는데 높은 진단적 정확도를 가지고 있으며, 자기공명영상의 급속스핀에코 T2 강조영상이 직결장암 조직의 종양 침윤 깊이를 평가하는데 가장 우수하였다.

흉부질환의 자기공명영상 (Magnetic Resonance Imaging in Thoracic Disease)

  • 송군식
    • Tuberculosis and Respiratory Diseases
    • /
    • 제40권4호
    • /
    • pp.345-352
    • /
    • 1993
  • The role of magnetic resonance(MR) imaging in the evaluation of thoracic disease has been limited Nontheless, MR has inherent properties of better contrast resolution than CT allowing tissue-specific diagnosis. MR has capability of direct imaging in sagittal, coronal, and oblique planes which provide better anatomic information than axial images of CT such as lesions in the pulmonary apex, aorticopulmonary window, peridiaphragmatic region, and subcarinal region. MR is sensitive to blood flow making it an ideal imaging modality for the evaluation of cardiovascular system of the thorax without the need for intravenous contrast media. Technical developments and better control of motion artifacts have resulted in improved image quality, and clinical applications of MR imaging in thoracic diseases have been expanded. Although MR imaging is considered as a problem-solving tool in patients with equivocal CT findings, MR should be used as the primary imaging modality in the following situations: 1) Evaluation of the cardiovascular abnormalities of the thorax 2) Evaluation of the superior sulcus tumors 3) Evaluation of the chest wall invasion or mediastinal invasion by tumor 4) Evaluation of the posterior mediastinal mass, especially neurogenic tumor 5) Differentiation of fibrosis and residual or recurrent tumor, especially in lymphoma 6) Evaluation of brachial plexopathy With technical developments and fast scan capabilities, clinical indications for MR imaging in thorax will increase in the area of pulmonary parenchymal and pulmonary vascular imaging.

  • PDF

Beam-scanning Imaging Needle for Endoscopic Optical Coherence Tomography

  • Yang, Woohyeok;Hwang, Junyoung;Moon, Sucbei
    • Current Optics and Photonics
    • /
    • 제5권5호
    • /
    • pp.532-537
    • /
    • 2021
  • We present a compact endoscopic probe in a needle form which has a fast beam-scanning capability for optical coherence tomography (OCT). In our study, a beam-scanning OCT imaging needle was fabricated with a 26G syringe needle (0.46 mm in outer diameter) and a thin OCT imaging probe based on the stepwise transitional core (STC) fiber. The imaging probe could freely rotate inside the needle for beam scans. Hence, OCT imaging could be performed without rotation or translation of the needle body. In our design, the structural integrity of the needle's steel tubing was preserved for mechanical robustness. Probing the optical signal was performed through the needle's own window formed at the end. For hand-held operation of our imaging needle, a light and compact scanner module (130 g and 45 × 53 × 60 mm3) was devised. Connected to the imaging needle, it could provide rotational actuation driven by a galvanometer. Because of its finite actuation range, our scanner module did not need a fiber rotary joint which might add undesirable complexity. The beam scan speed was 20 Hz and supported 20 frames per second at the maximum for endoscopic OCT imaging.

만성 기능성 변비 환자에서 동적 MR Defecography의 최신동향 (The Latest Trend of Dynamic MR Defecography for the Chronic Constipation Patient)

  • 윤석환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제27권4호
    • /
    • pp.17-21
    • /
    • 2004
  • 최근 의학 영상 기술의 발전과 함께 동적 골반 MRI(Pelvic magnetic resonance imaging)가 소개되었고 이러한 기술을 이용하여 동적 MR 배변조영술이 소개되어 환자의 진단에 도움을 주기 위해 사용되고 있다. 처음에 도입 당시에는 탈장(Enterocele)과 방광탈출증(Cystocele) 등을 진단하기 위하여 사용되었지만, 이후 장기의 탈출증(Prolapse), 또는 다른 골반 장기의 이상에 점점 그 유용성이 증명되어 현재는 기능성변비 등 다른 질환에서도 많은 보고가 있다. 본 논고에서는 골반 MRI 및 동적 MR 배변조영술에 대해서 소개하고 앞으로의 임상적 응용에 대한 전망을 살펴보도록 한다. 최근까지도 Pelvic MRI의 결과들은 앙와위(Supine position)에서 골반의 움직임을 관찰하는데 Yang 등은 26명의 골반 기관의 탈출증(Pelvic organ prolapse)을 가진 환자들을 관찰하고 Pubococcygeal line을 해부학적인 지표로 이용하여 좋은 결과를 얻었다고 보고했다. 이들은 Fast gradient recalled acquisition(fast GRASS)을 이용하여, Cystocoele, Prolapse, Enterocoele 그리고 Rectocoele 등을 증상이 없는 대조군과 비교하여 보고하였다. Kruyt 등은 Posterior compartment를 주로 관찰하여 MRI가 Fluoroscopy에 비하여 더 도움이 된다고 보고하였다. Healy 등은 Fast GRASS sequence를 이용하여 변비를 가진 환자와 변실금을 가진 환자, 그리고 증상이 없는 대조군을 대상으로 하여 동적 MRI 검사를 실시하였다. 이들은 변비나 변실금 증상과 관련되어 환자들의 Posterior compartment에 여러 곳에서 Prolapse을 관찰할 수 있었다. 이후 MRI 기술은 Lienemann 등에 의해서 더욱 발전했는데 그는 Fast T2 weighted turbo spin echo 기술을 이용하여 영상을 좀더 세밀하게 얻을 수 있게 되었다. 지금까지의 앙와위에서의 검사로 진단에 한계가 있었던 Intussusception 등의 질환을 Open MR 등의 방법으로 극복할 수 있다면 장래에는 방사선학적 배변조영술을 대체할 수 있는 검사법으로 발전할 수 있을 것으로 생각된다.

  • PDF

초분광 분해기의 광학계 설계 및 영상 처리 (Optical System Design and Image Processing for Hyperspectral Imaging Systems)

  • 허아영;최승원;이재훈;김태형;박동조
    • 한국군사과학기술학회지
    • /
    • 제13권2호
    • /
    • pp.328-335
    • /
    • 2010
  • A hyperspectral imaging spectrometer has shown significant advantages in performance over other existing ones for remote sensing applications. It can collect hundreds of narrow, adjacent spectral bands for each image, which provides a wealth of information on unique spectral characteristics of objects. We have developed a compact hyperspectral imaging system that successively shows high spatial and spectral resolutions and fast data processing performance. In this paper, we present an overview of the hyperspectral imaging system including the strucure of geometrical optics and several image processing schemes such as wavelength calibration and noise reduction for image data on Visible and Near-Infrared(VNIR) and Shortwave-Infrared(SWIR) band.

Demonstration of an ultrasonic imaging system for molten lead

  • Jonathan Hawes;Jordan Knapp;Robert Burrows;Robert Montague;Paul Wilcox;Hual-Te Chien;Jeff Arndt;Steve Walters
    • Nuclear Engineering and Technology
    • /
    • 제56권4호
    • /
    • pp.1460-1471
    • /
    • 2024
  • 2D and 3D ultrasonic imaging has so far not been demonstrated in pure molten lead in the open literature. In this study the development of such an ultrasonic device for imaging is outlined and results from testing at 380 ℃ in lead are presented. The main difficulties were found to be achieving then maintaining suitable wetting while ensuring suitable durability of the device, both due to the harsh nature of molten lead and the elevated temperatures. The successful detection and imaging (2D and 3D), of differently shaped targets, where the features were above the size of the transmitted ultrasound beam was demonstrated.