• 제목/요약/키워드: Fast MR imaging

검색결과 110건 처리시간 0.027초

Evaluation of Hydration Effect on Human Skin by $^1H$ MRS at 14.1T

  • Choi Chi-Bong;Hong Sung-Tak;Choe Bo-Young;Woo Dong-Chul;Yoon Seong-Ik;Cho Ji-Hyun;Lee Chul-Hyun;Cheong Chae-Joon;Park Sang-Yong;Oh Chil-Hwan
    • 한국자기공명학회논문지
    • /
    • 제10권1호
    • /
    • pp.105-114
    • /
    • 2006
  • Purpose: We achieved high resolution MR imaging and spectra of human skin in vitro with using a 14.1 T MRI/MRS system, and evaluated the hydration effect of various cosmetic products by measuring the skin's. moisture concentration. Materials and Methods: We used the Bruker 14.1 T MRI/MRS system with a vertical standard bore that was equipped with a DMX spectrometer gradient system (200 G/cm at a maximum 40 A), RF resonators (2, 5 and 10 mm) and Para Vision software. Spin echo and fast spin echo pulse sequences were employed for obtaining the high resolution MR images. The 3D-localized point resolved spectroscopy (PRESS) method was used to acquire the MR spectra. Results: The high resolution MR images and spectra of human skin in vitro were successfully obtained on a 14.1 T system. The water concentration of human skin after applying a moisturizer was higher than that before applying a moisturizer. Conclusions: The present study demonstrated that the high-resolution MR images and spectra of human skin from a high field NMR instrument could be applicable to evaluating the hydration state of the stratum corneum.

  • PDF

삼각 섬유성 연골(TFCC) 손상 환자의 자기공명영상 검사 시 Fat Suppressed 3D FSPGR T1 강조 기법에 대한 Fat Suppressed Isotropic 3D FSE T1 강조 기법의 비교 분석 및 유용성에 관한 평가 (The Comparative Analysis Study and Usability Assessment of Fat Suppressed 3D FSPGR T1 Technique and Fat Suppressed Isotropic 3D FSE T1 Technique when Examining MRI of Patient with Triangular Fibrocartilage Complex (TFCC) Tear)

  • 강성진;조용근;이성수
    • 한국자기학회지
    • /
    • 제26권3호
    • /
    • pp.105-114
    • /
    • 2016
  • 삼각 섬유성 연골(TFCC) 손상 환자의 평가를 위하여 fat suppressed 3D fast spoiled gradient recalled T1 기법과 fat suppressed Isotropic 3D fast spin echo T1 기법을 이용하여 영상을 획득하였다. 정량적 평가를 위해 각각의 영상에서 signal to noise ratio 및 contrast to noise ratio 값을 측정하고, Mann-Whitney U 검정으로 두 기법 간의 통계적 유의성을 검증하였다. 또한 정성적 평가를 위해 영상의학의 2명이 각각의 영상을 관찰하여, TFCC의 형태, 영상 내 인공음영, 병변의 묘사 정도의 3가지 항목을 선정한 후 이를 4점 척도(0: 진단 불가, 1: 부족함, 2: 충분함, 3: 좋음)로 평가하였고, Kappa-value 검정을 이용하여 두 관찰자 간의 일치도 검증을 하였다. 영상획득에는 3.0 Tesla MR 장비와 8-channel RF coil을 사용하였다. 정량적 평가 결과, 모든 영상 단면에서 signal to noise ratio 및 contrast to noise ratio 값이 Isotropic 3D fast spin echo T1 기법이 높게 나타났으며, Mann-Whitney U 검정을 이용한 두 영상기법 간의 검증도 통계적으로도 유의하였다(p < 0.05). 정성적 평가 결과, 관찰자 1, 2 모두에서 Isotropic 3D fast spin echo T1 기법의 평가 결과가 더 높게 나타났으며, Kappa-value 검증을 이용한 두 관찰자 간 평가 결과의 일치도 검증도 통계적으로 유의하였다(p < 0.05). 결론적으로 TFCC 손상 환자의 자기공명영상 검사 시 fat suppressed Isotropic 3D fast spin echo T1 기법의 적용은 TFCC 병변의 감별에 보다 유용한 진단적 정보를 제공 할 수 있을 것이라 생각된다.

Development of a Brain Phantom for Multimodal Image Registration in Radiotherapy Treatment Planning

  • H. S. Jin;T. S. Suh;R. H. Juh;J. Y. Song;C. B. Y. Choe;Lee, H .G.;C. Kwark
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.450-453
    • /
    • 2002
  • In radiotherapy treatment planning, it is critical to deliver the radiation dose to tumor and protect surrounding normal tissue. Recent developments in functional imaging and radiotherapy treatment technology have been raising chances to control tumor saving normal tissues. A brain phantom which could be used for image registration technique of CT-MR and CT-SPECT images using surface matching was developed. The brain phantom was specially designed to obtain imaging dataset of CT, MR, and SPECT. The phantom had an external frame with 4 N-shaped pipes filled with acryl rods, Pb rods for CT, MR, and SPECT imaging, respectively. 8 acrylic pipes were inserted into the empty space of the brain phantom to be imaged for geometric evaluation of the matching. For an optimization algorithm of image registration, we used Downhill simplex algorithm suggested as a fast surface matching algorithm. Accuracy of image fusion was assessed by the comparison between the center points of the section of N-shaped bars in the external frame and the inserted pipes of the phantom and minimized cost functions of the optimization algorithm. Technique with partially transparent, mixed images using color on gray was used for visual assessment of the image registration process. The errors of image registration of CT-MR and CT-SPECT were within 2mm and 4mm, respectively. Since these errors were considered within a reasonable margin from the phantom study, the phantom is expected to be used for conventional image registration between multimodal image datasets..

  • PDF

여러 간외담도 질환에서 삼차원적 자기공명 췌담관 조영술과 내시경적 역행성 췌담관 조영술과의 비교: 진단적 정확성을 중심으로 (Comparison of Diagnostic Accuracy of Three-Dimensional MR Cholangiopanceatography and ERCP in Various Extrahepatic Biliary Lesions)

  • 김경숙;이문규;김명환;이승규;김표년;오용호
    • Investigative Magnetic Resonance Imaging
    • /
    • 제1권1호
    • /
    • pp.148-153
    • /
    • 1997
  • 목적: 다양한 간외담도질환에서 3차원적 자기공명췌담도조영술(MR cholangiopancreatography, MRCP)의 진단적 가치를 내시경적 역생성 췌담도조영술(ENDOSCOPIC RETROGRADE CHOLANGIOPANCREATOGRAPHY, ERCP)와 비교하여 알아보고자 하였다. 대상 및 방법: 간외담도질환이 의심되는 46명의 환자에 대하여 MRCP와 ERCP를 각각 시행하였다. MRCP는 reverse fast imaging with a steady-state free precession(reverse FISP:PSIF) 기법을 이용하여 얻어낸 후 MIP algorithm을 이용하여 재구성하였다. 담도확장여부와 폐쇄부위 진단에 대한 MRCP의 정확성을 ERCP를 최적기준으로 하여 평가하였다. 또한 악성 및 양성병변의 감별과 종합적인 진단정확도를 MRCP와 ERCP간에 비교하였다. 결과: MRCP의 담도확장여부 예측은 민감도 94.6%, 특이도 75.0%, 정확도 91.1%였다. 폐쇄부위 예측의 정확도는 87.0%였다. 악성과 양성병변의 감별에 있어 MRCP와 ERCP의 민감도, 특이도, 정확도는 각각 76.2%, 87.5%, 82.2%와 71.4%, 83.3%, 77.8%였다. 각각의 지롼에 대한 전체적 진단의 정확도는 MRCP가 60.0%, ERCP가 55.6%였다. 결론: 3D MRCP는 간외담도질환에 있어 ERCP와 비교하여 손색없는 진단적 가치를 가지며, 앞으로 ERCP를 대체할 수 있는 좋은 검사방법이라고 생각된다.

  • PDF

The Role of Dynamic Contrast Enhanced MR Mammography in Differentiation between Benign and Malignant Breast Lesions

  • 한송이;차은숙;정상설;김학희;변재영;이재문
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2002년도 제7차 학술대회 초록집
    • /
    • pp.135-135
    • /
    • 2002
  • Purpose: To assess diagnostic accuracy of dynamic contrast enhanced MR mammography in differentiating between benign and malignant lesions. Materials and methods: Ninety-three patients with suspicious mammographic, sonographic or palpable findings underwent pre- or postoperative contrast-enhanced MR imaging of breast using three dimensional fast low-angle shot (3D FLASH) sequence (16/4 msec[repetition time / echo time], 20 flip angle, 3mm slice thickness with no slice gap, 256 by 256 in-plane matrix) covering whole breasts. T1 weighted images were obtained before and after bolus administration of gadopentetate dimeglumine (0.15 mmol/kg). Subtraction images and time-signal intensity curves of region of interest were obtained sequentially and correlated with pathologic diagnoses of lesions.

  • PDF

A Variational Model For Longitudinal Brain Tissue Segmentation

  • Tang, Mingjun;Chen, Renwen;You, Zijuan
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제16권11호
    • /
    • pp.3479-3492
    • /
    • 2022
  • Longitudinal quantification of brain changes due to development, aging or disease plays an important role in the filed of personalized-medicine applications. However, due to the temporal variability in shape and different imaging equipment and parameters, estimating anatomical changes in longitudinal studies is significantly challenging. In this paper, a longitudinal Magnetic Resonance(MR) brain image segmentation algorithm proposed by combining intensity information and anisotropic smoothness term which contain a spatial smoothness constraint and longitudinal consistent constraint into a variational framework. The minimization of the proposed energy functional is strictly and effectively derived from a fast optimization algorithm. A large number of experimental results show that the proposed method can guarantee segmentation accuracy and longitudinal consistency in both simulated and real longitudinal MR brain images for analysis of anatomical changes over time.

DSP를 이용한 자기공명영상의 경사자계 파형 발생기 개발 (Development of MRI gradient waveform generator using DSP)

  • 고광혁;권의석;송영철;김휴정;김치영;안창범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 G
    • /
    • pp.3147-3149
    • /
    • 1999
  • In this paper, we develop a TMS320C31- 60 DSP board to generate spiral gradient waveforms for Spiral imaging, one of the ultra fast MRI methods. In Spiral imaging, accurate gradient waveforms are very important to acquire high quality image. For this purpose, sampling rate for generating the gradient waveforms is set twice as high as the data sampling rate. With the developed DSP board accurate gradient waveforms are obtained. Ultra fast MR image with the developed DSP board is currently under development.

  • PDF

림프절의 자기공명영상의 특징: 가토에서 T1과 T2 강조영상의 비교 (Magnetic resonance imaging characteristic of lymph nodes: Comparison of T1 and T2 weighted image in normal rabbits)

  • 이기창;최민철;최호정;윤정희;최승홍;문우경;정진욱
    • 대한수의학회지
    • /
    • 제44권2호
    • /
    • pp.311-315
    • /
    • 2004
  • The detection of lymph node metastasis is an important step in tumor staging and is significant for therapy planning. It has been challenged to yield an appropriate image with diagnostic methods such as Magnetic Resonance (MR) and Computed Tomography (CT). Though CT has been used widely and accessed easily to show internal organs, it can hardly provide difference between lymph node and adjacent vessel or fat tissue. It has been well established that MR can reveal the subtle discrepancy within soft tissue. This study investigated the suitability of MR lymph node imaging without contrast enhancement by comparison of T1-weighted image (T1WI) and T2- weighted image (T2WI) in ten normal rabbits. According to the pulse sequence optimized from preliminary study, T1-weighted spin-echo (repetition time/echo time=400/12 ms) and T-2 weighted fast spin-echo (repetition time/echo time=3500/84 ms) images covering the hind limbs and pelvic region were acquired at 1.5 T. Two radiologists scrupulously evaluated the MR images in consensus. And signal intensity of lymph nodes was compared with that of adjacent fat. Statistical analysis showed that T1-weighted coronal image visualized the lymph nodes (iliac, superficial inguinal and popliteal lymph nodes) quickly and consistently rather than T2-weighted one. Conclusively, T1WI for evaluation of lymph nodes is moderately better than T2WI and appears to have potential for quick and sufficient mapping of the lymph nodes. In addition, this normal MR image of lymph nodes could be applied to further study for the evaluation of lymphatic system in abscess and tumor bearing animal model.

Carotid Intraplaque Hemorrhage Imaging: Diagnostic Value of High Signal Intensity Time-of-Flight MR Angiography Compared with Magnetization-Prepared Rapid Acquisition with Gradient-Echo Sequencing

  • Ahn, Ji-eun;Kwak, Hyo Sung;Chung, Gyung Ho;Hwang, Seung Bae
    • Investigative Magnetic Resonance Imaging
    • /
    • 제22권2호
    • /
    • pp.94-101
    • /
    • 2018
  • Purpose: To determine the value of the appearance of the high signal intensity halo sign for detecting carotid intraplaque hemorrhage (IPH) on maximum intensity projection (MIP) of time-of-flight (TOF) MR angiography (MRA), based on high signal intensity on magnetization-prepared rapid acquisition with gradient-echo (MPRAGE) sequencing. Materials and Methods: A total of 78 carotid arteries in 65 patients with magnetization-prepared rapid acquisition gradient-echo (MPRAGE) positive on carotid plaque MR imaging were included in this study. High-resolution MR imaging was performed on a 3.0-T scanner prior to carotid endarterectomy or carotid artery stenting. Fast spin-echo T1- and T2-weighted axial imaging, TOF, and MPRAGE sequences were obtained. Carotid plaques with high signal intensity on MPRAGE > 200% that of adjacent muscle on at least two consecutive slices were defined as showing IPH. Halo sign of high signal intensity around the carotid artery was found on MIP from TOF MRA. Continuous and categorical variables were compared among groups using the Mann-Whitney test and Fisher's exact tests. Results: Of these 78 carotid arteries, 53 appeared as a halo sign on the TOF MRA. The total IPH volume of patients with a positive halo sign was significantly higher than that of patients without a halo sign ($75.0{\pm}86.8$ vs. $16.3{\pm}18.2$, P = 0.001). The maximum IPH axial wall area in patients with a positive halo sign was significantly higher than that of patients without a halo sign ($11.3{\pm}9.9$ vs. $3.7{\pm}3.6$, P = 0.000). Conclusion: High signal intensity halo of IPH on MIP of TOF MRA is associated with total volume and maximal axial wall area of IPH.

유동모형을 이용한 저속유동의 자기공명영상 (MR Imaging of Slow-flow Using a Flow Phantom)

  • Dae-Cheol Cheong;Kyung-Jae Jung;Young-Hwan Lee;Nak-Kwan Sung;Duck-Soo Chung;Ok-Dong Kim;Jong-Ki Kim
    • Investigative Magnetic Resonance Imaging
    • /
    • 제5권2호
    • /
    • pp.116-122
    • /
    • 2001
  • 목적 : 고식적 스핀에코, 위상 대조 경사에코, 고속 GRASS, 중T-2강조 고속스핀에코 연쇄를 각각 유동모형에 적용시켜, 저속유동에 대한 자기공명영상의 민감도를 찾아내고자 한다. 대상 및 방법 뇌실-복강 단락 도관과 GE 모형으로 이루어진 유동모형으로 싸이폰 효과에 의한 지속적인 가변 유속의 흐름을 내보내고, 각각의 유속에 위의 네 가지 자기공명영상연쇄를 적용시켰다. 0.08 ml/min 에서 1.7 ml/min 범위의 유량의 흐르는 액체와 정지된 액체에서 획득된 자기공명영상의 신호강도를 비교한 결과를 요약하면 다음과 같다. 결과 0.17 ml/min 이상의 느린 흐름에서는 고식적 스핀에코영상이 가장 우수한 정지-유동 액체사이의 겉보기대조를 보이나, 그 이하의 매우 느린 흐름에서는 GRASS 영상이 더 높은 민감도를 보였다. 결론 : 4가지 자기공명펄스연쇄는 0.08 ml/min에서 1.7 ml/min 범위의 유량의 흐름에서 서로 다른 민감도를 보였다. 이 결과는 임상적으로, 단락수술후의 뇌척수액의 흐름이나 혈관내의 혈전에 의한 흐름의 변이 등의 인체내의 저속유동을 검출하는 비침습적방법으로 유용하게 적용될 수 있을 것이다.

  • PDF