• Title/Summary/Keyword: Faraday cell

Search Result 26, Processing Time 0.029 seconds

A Study on the Performance of Catalysts for the Recombination of Oxyhydrogen Gas Generated in Secondary Battery (이차전지내 발생하는 수소-산소 혼합기체 재결합용 촉매의 성능 측정 및 이론적 모델 연구)

  • Kim, Yong-Sik;Chang, Min-Hwan;Ju, Jeh-Beck
    • Journal of the Korean Electrochemical Society
    • /
    • v.17 no.1
    • /
    • pp.71-77
    • /
    • 2014
  • The performance of catalysts for the recombination of oxyhydrogen gas was measured and compared with the results obtained from theoretical model. The oxyhydrogen gas was generated by the electrolysis cell and recombined through the fixed bed catalytic reactor. The yield that is the ratio of water-amount produced to the water-amount consumed in the electrolysis cell was increased with the increase of KOH concentration in electrolysis cell and the applied current. The catalyst 1 showed the best performance and the yield was under 60 %. The faradic yield calculated by Faraday's law showed about 100% in maximum with catalyst 1. The production rate of water generated by the recombination was 5-40 g/day dependent on the flow rate of mixed gas. Considering the results calculated from the pseudo-homogeneous catalytic reactor model, the hot point inside the reactor was moved to the direction of outlet and the maximum temperatures were $440-480^{\circ}K$ when the gas flow rate increased. The production rate of water calculated from the theoretical model showed good agreement with experimental results below the flow rate of $0.5cm^3/sec$, but there were much differences above that flow rate.

Design of a high-speed DFE Equaliser of blind algorithm using Error Feedback (Error Feedback을 이용한 blind 알고리즘의 고속 DFE Equalizer의 설계)

  • Hong Ju H.;Park Weon H.;Sunwoo Myung H.;Oh Seong K.
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.42 no.8 s.338
    • /
    • pp.17-24
    • /
    • 2005
  • This paper proposes a Decision Feedback Equalizer (DFT) with an error feedback filter for blind channel equalization. The proposed equalizer uses Least Mean Square(LMS) Algorithm and Multi-Modulus Algorithm (MMA), and has been designed for 64/256 QAM constellations. The existing MMA equalizer uses either two transversal filters or feedforward and feedback filers, while the proposed equalizer uses feedforward, feedback and error feedback filters to improve the channel adaptive performance and to reduce the number of taps. The proposed equalizer has been simulated using the $SPW^{TM}$ tool and it shows performance improvement. It has been modeled by VHDL and logic synthesis has been performed using the $0.25\;\mu m$ Faraday CMOS standard cell library. The total number of gates is about 190,000 gates. The proposed equalizer operates at 15 MHz. In addition, FPGA vertification has been performed using FPGA emulation board.

Electrochemical Properties of a Zirconia Membrane with a Lanthanum Manganate-Zirconia Composite Electrode and its Oxygen Permeation Characteristics by Applied Currents

  • Park, Ji Young;Jung, Noh Hyun;Jung, Doh Won;Ahn, Sung-Jin;Park, Hee Jung
    • Journal of the Korean Ceramic Society
    • /
    • v.56 no.2
    • /
    • pp.197-204
    • /
    • 2019
  • An electrochemical oxygen permeating membrane (OPM) is fabricated using Zr0.895Sc0.095Ce0.005Gd0.005O2-δ (ScCeGdZ) as the solid electrolyte and aLa0.7Sr0.3MnO3-bScCeGdZ composite (LZab, electrode) as the electrode. The crystal phase of the electrode and the microstructure of the membrane is investigated with X-ray diffraction and scanning electron microscopy. The electrochemical resistance of the membrane is examined using 2-p ac impedance spectroscopy, and LZ55 shows the lowest electrode resistance among LZ82, LZ55 and LZ37. The oxygen permeation is studied with an oxygen permeation cell with a zirconia oxygen sensor. The oxygen flux of the OPM with LZ55 is nearly consistent with the theoretical value calculated from Faraday's Law below a critical current. However, it becomes saturated above the critical current due to the limit of the oxygen ionic conduction of the OPM. The OPM with LZ55 has a very high oxygen permeation flux of ~ 3.5 × 10-6 mol/㎠s in I = 1.4 A/㎠.

Effect of Current Density on Material Removal in Cu ECMP (구리 ECMP에서 전류밀도가 재료제거에 미치는 영향)

  • Park, Eunjeong;Lee, Hyunseop;Jeong, Hobin;Jeong, Haedo
    • Tribology and Lubricants
    • /
    • v.31 no.3
    • /
    • pp.79-85
    • /
    • 2015
  • RC delay is a critical issue for achieving high performance of ULSI devices. In order to minimize the RC delay time, we uses the CMP process to introduce high-conductivity Cu and low-k materials on the damascene. The low-k materials are generally soft and fragile, resulting in structure collapse during the conventional high-pressure CMP process. One troubleshooting method is electrochemical mechanical polishing (ECMP) which has the advantages of high removal rate, and low polishing pressure, resulting in a well-polished surface because of high removal rate, low polishing pressure, and well-polished surface, due to the electrochemical acceleration of the copper dissolution. This study analyzes an electrochemical state (active, passive, transpassive state) on a potentiodynamic curve using a three-electrode cell consisting of a working electrode (WE), counter electrode (CE), and reference electrode (RE) in a potentiostat to verify an electrochemical removal mechanism. This study also tries to find optimum conditions for ECMP through experimentation. Furthermore, during the low-pressure ECMP process, we investigate the effect of current density on surface roughness and removal rate through anodic oxidation, dissolution, and reaction with a chelating agent. In addition, according to the Faraday’s law, as the current density increases, the amount of oxidized and dissolved copper increases. Finally, we confirm that the surface roughness improves with polishing time, and the current decreases in this process.

Oxygen Ion Beam Deposition 법을 이용한 저온 ITO film에 Oxygen radical(O)이 미치는 영향에 대한 연구

  • 김정식;배정운;김형종;정창현;이내응;염근영
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2000.02a
    • /
    • pp.117-117
    • /
    • 2000
  • 높은 광학적 투과성과 전기전도성을 갖는 ITO film은 solar cell같은 optoelectronic device나 휴대용 소형 TV, flat panel display 등의 투명전극으로 그 응용 분야가 광범위하여 많은 연구가 수행되어져 왔다. 기판으로서 유리를 사용할 때 생기는 활용범위 제한을 극복하고자 최근 유기물 위에 증착이 가능한 저온 증착방법에 대한 연구가 활발히 이루어지고 있다. 그 가운데 이온빔과 같은 energetic한 beam을 이용한 박막의 제조는 기판을 플라즈마 발생지역으로부터 분리시켜 이온빔의 flux 및 에너지, 입사각 등의 자유로운 조절을 통해 상온에서도 우수한 성질의 박막형성 가능성이 제시되어 지고 있다. ITO박막을 형성하는 방법 중 스프레이법이나 CVD법과 같은 화학적 증착방법은 증착시 350-50$0^{\circ}C$의 고온이 필요하고 현재 가장 많이 응용되어 지고 있는 sputter법은 15$0^{\circ}C$정도의 가열이 필요하므로 앞으로 응용가능성이 매우 커서 많은 연구가 진행중인 플라스틱과 아크릴 같은 flexible 한 기판위 증착에 적용이 불가능하다. 본 실험에서는 IBAD(Ion Beam Assisted Deposition)법을 이용하여 저온 ITO film을 유리와 유기막위에 증착하는 연구를 수행하였다. 유기막위에 증착된 ITO는 보다 가볍고 충격에 강하고 유리에 못지 않은 투과성을 가지고 있으나 현재 film의 quality 향상에 대한 요구가 증대되어 지고 있는 실정이다. 따라서, 본 실험에서는 dual oxygen ion gun의 조건변화에 따른 ITO film의 특성변화를 관찰하였다. 고정된 증?율에 한 개 ion gun에 ion flux를 고정시킨 후 또 다른 ion gun에서 발생하는 oxygen radical의 영향을 조사하였으며 oxygen radical의 rf power에 따른 변화는 OES(Optical emission spectroscopy)를 사용하였다. 너무 적은 oxygen ion beam flux나 oxygen radical은 film의 전도도 및 투과도를 저하시켰고 반면 너무 과도한 flux의 증가 시는 전도도는 감소하였고 투과도는 증가하는 경향을 보였다. 기판에 도달하는 oxygen ion flux는 faraday cup을 이용하여 측정하였으며 증착된 ITO film은 XPS, UV-spectrometer, 4-point probe를 이용하여 분석하였다.

  • PDF

Evaluation of Corrosion Behavior of Railway Axle Material (RSA1) in Seawater (해수환경에서의 차축소재(RSA1) 부식특성 평가)

  • Choi, Dooho;Seo, Sung-il
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.8
    • /
    • pp.5039-5044
    • /
    • 2015
  • In this study, we evaluated corrosion behavior of a common rolling stock axle material, RSA1, in seawater. 3-electrode electrochemical cell experiment was conducted using artificial sea water, fabricated according to ASTM-D1141 set by American Society for Testing and Materials, where the corrosion current density and corrosion rate were determined to be $18.3{\mu}A/cm2$ and 0.217 mm/yr, respectively, by employing potentiodynamic test method and impedance spectroscopy method. Considering the fact that life time of railway car is ~25 years, the expected corrosion layer depth is 5mm. Constant-current corrosion test was conducted to accelerate the corrosion process, to reach corrosion periods of 1,3 and 4 years based on Faraday's law, followed by tension tests where the reduced specimen gauge cross-section was re-measured for stress calculation. While no apparent corrosion-related changes in mechanical properties were observed in the elastic regime, the reduction in ductility of the material was found to be increased as the corrosion period increased. The results of this study are expected to be basic corrosion data for the design of rolling stock axles, which will be operated in the sea water environment.