• Title/Summary/Keyword: Fan-out

Search Result 535, Processing Time 0.028 seconds

The performance and flow characteristics of a small propeller fan with a back-plate (뒷판이 있는 소형 프로펠러 팬의 성능 및 유동특성)

  • Gang, Sin-Hyeong;Kim, Jin-Gwon;Lee, Seung-Bae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.4
    • /
    • pp.1491-1500
    • /
    • 1996
  • Unstable performance deterioration was found on the performance curve of a small propeller fan with a back plate. To investigate this phenomenon and the effects of the back-plate on the performance of the fan, performance tests and flow measurement using 3-hole pitot tube were carried out. Measurements showed that when the flow rate is small, the radial flow dominates, and when the flow rate is large, the axial flow dominates. Performance characteristic of the propeller fan changes from radial to axial type as the flow rate increases. Unstable performance changes are the result of type change of the flow through the fan.

Effects of Silencer Design on the Performance of Jet-fan (제트홴 소음기 형상이 성능에 미치는 영향)

  • Oh, In-Gyu;Choi, Young-Seok;Kim, Joon-Hyung;Yang, Sang-Ho;Kwon, Oh-Myoung
    • The KSFM Journal of Fluid Machinery
    • /
    • v.13 no.6
    • /
    • pp.25-29
    • /
    • 2010
  • In this paper, a numerical study has been carried out to investigate the influence of silencer design variables on the performance of a jet fan. In order to achieve an optimum jet fan design and to explain the interactions between the different geometric configurations in the jet fan, three-dimensional computational fluid dynamics and the Design of Experiments method have been applied. Two geometric variables, i.e., cap size and silencer length, were employed to improve the performance of the jet fan. The objective functions of the jet fan are defined as the effective velocity and total efficiency at the operating condition. Based on the results of computational analyses, the flow characteristics were discussed. The effect of silencer with a specific roughness on the performance was also discussed.

Study on Noise Reduction of an Axial Fan for Refrigerator through Modification of the Blade Tip (깃 끝단 개선을 통한 냉장고용 축류홴 저소음화에 대한 연구)

  • 김창준;전완호;정용규
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.639-644
    • /
    • 2002
  • In this paper, a successful noise reduction of an axial flow fan for a refrigerator is presented. The vortex sheet generated at the blade tip of fan was suppressed by changing the shape of the tip. The structure of vortex sheet and detailed flow pattern around the fan were studied by two-dimensional LDV(Laser-Doppler Velocimetry). Effective ways to work out the result as mentioned above are to make the tip of the blade varied in thickness and to have elliptical shapes. To seek the optimal value fur the shape of new fan, several cases were examined. Through the application of the methods, the refrigerator became less noisy by 3.8 dB(A) in terms of air-borne noise produced only by the axial flow fan compared to the current one.

  • PDF

A Study on the Design of a Fan-Sink Considering the Flow Fields Behind the Fan Outlet (홴 후방 유동장을 고려한 홴싱크 설계에 관한 연구)

  • Jo, Jin-Su;Han, Seung-Ho;Han, Cheol-Hui
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.8
    • /
    • pp.1055-1061
    • /
    • 2002
  • A numerical and experimental study on the flow fields behind the fan outlet was carried out to improve the performance of a conventional fan-sink(fan and heat sink). Conventional fan-sinks have a heat sink of which fin configurations tend to increase the flow resistance, thus decreasing the performance and the cooling capabilities of a fan-sink. Lifting surface method is used for the prediction of flow fields behind the fan outlet. Oil-dot flow visualization technique is applied for the validation of numerical results. The numerical results and experimental data show agreement each other. A conventional heat sink is modified and redesigned using flow patterns behind the fan outlet. The newly designed heat sink has the configuration of curved fins which minimize flow resistance. It showed improvements in both cooling: capabilities and volumetric flow rate compared to the conventional one.

Design of Automotive Engine Cooling Fan and Study on Noise Reduction through Modification of System (자동차용 냉각홴의 설계와 시스템 개선을 통한 저소음화 연구)

  • 김병주;강상규;김규영;이재영;이덕호;신동수
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.11
    • /
    • pp.1107-1114
    • /
    • 2004
  • Axial fans are widely used for automotive engine cooling device due to their ability to produce high flow rate to keep engine cool. At the same time, the noise generated by these fans causes one of the most serious problems. Especially, engine cooling fan noise in idle condition of a car is noticeable. Therefore. the high efficient and low-noise fan is seriously needed. When a new fan system is designed, system resistance and non-uniform inflow are the key factors to get the high performance and low noise fan system. In this study, aerodynamic and acoustic calculations are carried out on the automotive cooling fan and system. Effects of various design parameters are studied through the free wake analysis and experiments. Better performance and noise characteristic are obtained for the new design fan using the methodology. Furthermore through the modification of the fan system geometry parameters, the fan system produce more flow rate and become less noisy.

MULTI STAGE SHAPE OPTIMIZATION OF CENTRIFUGAL FAN FOR HOME APPLIANCE USING CFD (전산유체역학을 활용한 가전 제품용 원심팬 블레이드의 단계별 형상 최적화)

  • Kim, J.S.;Kang, T.G.
    • Journal of computational fluids engineering
    • /
    • v.21 no.3
    • /
    • pp.39-47
    • /
    • 2016
  • We conducted a multi-stage optimization to secure the desired performance of a centrifugal fan for home appliance in an early stage of product development. In optimization, the static pressure at the outlet of the fan is chosen as an objective function that is to be maximized, providing the required flow rate at the operating point of the fan. The optimization procedure begins with parameters for an initial baseline fan design. The baseline design is optimized by using a commercial optimization package. Accordingly, the corresponding blade models with a set of geometrical parameters are generated. Flow through a fan is simulated by solving the Reynolds-averaged Navier-Stokes equations. A multi-stage optimization scheme is employed to determine the family of optimum values for the parameters, leading to the pressure increase at the outlet of the fan. To validate the numerically obtained optimal design parameters, we fabricated the three types of fans using rapid prototyping and assessed the performance using a fan tester. Experimental results show that the design parameters at each stage satisfy the goal of optimization. The multi-stage optimization process turned out to be a useful tool in the development of a centrifugal fan.

Investigation of Heating Performance of Kerosene Fan Heater (석유 홴 히터의 난방 능력 고찰)

  • Kim, Jang-Kweon;Jeong, Kyu-Jo
    • Journal of Power System Engineering
    • /
    • v.1 no.1
    • /
    • pp.51-60
    • /
    • 1997
  • In this paper, we investigated the heating performance and the basic characteristics required for normal combustion of kerosene fan heater. And also the iso-velocity contours and the iso-temperature contours of hot gas discharged from the exit of kerosene fan heater were analyzed. The experiment was carried out with kerosene fan heater attached to the blow-down-type subsonic wind tunnel with a test section of $240mm{\times}240mm{\times}1200mm$. The purpose of this paper was to obtain the basic data for new design from conventional kerosene fan heater. Consequently it was found that (i) the pressure ratio $P_2/P_1$ had a comparatively constant value of 0.844 according to the increase of the revolution of turbo fan, (ii) the primary excess air ratio had a range of $0.84{\sim}1.11$ during normal combustion, and (iii) the heating performance of kerosene fan heater had a range of $1,494{\sim}3,852kcal/hr$.

  • PDF

Development of Fan Balancer System for Detecting Unbalance of Automobile Cooling Fan (자동차용 냉각팬의 불량검출을 위한 팬 밸런서 시스템 개발)

  • Kim, Sung-Ho;Youk, Yui-Su
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.19 no.1
    • /
    • pp.83-89
    • /
    • 2009
  • Generally, automobile cooling fan is used to lower the temperature of radiator. The cooling fans are manufactured by plastic injection molding process. The center of gravity of cooling fan is often deviated from the center due to the use of deteriorated materials. As the unbalanced of the cooing fan can generate noise, it is required to measure the degree of deviation of center of gravity in the cooling fan. In this work, automatic fan balancer which can effectively detect the magnitude and position of the unbalanced cooling fan is proposed and several experiments are carried out to verify the feasibility of the proposed algorithm.

Flow Characteristics due to Cutoff angle of Turbo-Fan for Industries (산업용 Turbo형 송풍기의 Cutoff 각도에 따른 유동특성)

  • Yun, Ji-Hun;Jeong, In-Guk;Yi, Chung-Seob;Suh, Jeong-Se
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.10 no.5
    • /
    • pp.91-96
    • /
    • 2011
  • This study aims to analyze the flow characteristics of turbo-fan which is applied to the industrial field. Numerical analysis has been carried out to investigate the pulsation behavior of exhaust air flown out turbo fan by rotating impeller with constant speed. Moving mesh technique is proved as time-accurate solution for the flow inside impeller. As numerical results come within the error range of 1% by comparing with theoretical results, the numerical analysis can be verified. Cutoff angle has large influence on the amplitude of pulsation and the least pulsation of flow can be generated by the cutoff angle of $20^{\circ}$.

An Experimental Study on Selection Pitch Angle on backward flow of an Axial Fan with Adjustable Pitch Angle Blades (피치각 조정형 송풍-역풍 겸용 축류팬에서 배연용 피치각 선정을 위한 실험적 연구)

  • Chang, Taek-Soon;Hur, Jin-Huek;Moon, Seung-Jae;Lee, Jae-Heon
    • Plant Journal
    • /
    • v.5 no.1
    • /
    • pp.45-50
    • /
    • 2009
  • In this study, the experimental study has carried out to select pitch angle on the backward flow in an axial fan that has adjustable pitch blades. With the change of pitch angle of axial fan with adjustable blade, air flow rate, pressure and air flow direction can be changed. Because of this merit, adjustable axial fan can be used in the backward flow. For the selection of the backward flow pitch angle, fan performance test method is selected by KS B 6311. Dynamic pressure, static pressure, electric current and voltage are measured in each pitch angles of axial fan that are $36^{\circ}$, $-16^{\circ}$, $-21^{\circ}$, $-26^{\circ}$, $-31^{\circ}$ and $-36^{\circ}$. In the result of test, fan performance curves at several pitch angle has been investigated. Finally, pitch angle of $-26^{\circ}$ has been selected to get largest flow rate at backward flow situation.

  • PDF