• 제목/요약/키워드: Fan-motor

검색결과 252건 처리시간 0.03초

F.E.M.을 이용한 냉장고용 FAN 모터의 해석과 Niching Algorithm을 이용한 최적 설계에 관한 연구 (A Study for the Optimum Design of Fan Motor In Refrigerator Using A Niching Algorithm and Characteristic Analysis Using The Finite E16men1 Method)

  • 한동규;정태경;진용선
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 A
    • /
    • pp.214-216
    • /
    • 1999
  • This paper discussed an optimal designs of 2 pole fan motors in refrigerator using a Niching Algorithm. We applied a Niching method to multi-objective optimal design of air gap construct. This Niching genetic algorithm is called "Restricted Competition Selection"(RCS) that is suitable for real world problem such as shape or structural optimization of electromagnetic device. The finite element method being used for nonlinear numerical characteristic analysis is provided exact solution in the system. Through this process is reduced the cogging torque ripple in air gap.

  • PDF

박판형 고효율 터보홴의 공력학적 설계 (Aerodynamic Design of Slim and High-efficient Turbo-Fan)

  • 이명재;김남욱;박덕준;조인수;이승배
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2600-2605
    • /
    • 2008
  • Turbo-fans for a FFU unit should be aerodynamically designed to provide the FFU system with the given flow-rate at the lowest rotational-speed by considering the interaction effect with the FFU casing. In this study, slim and highly efficient turbo-fans are designed to satisfy the given performance at the specific speed by using the hybrid-stacking method of an inducer and a 2D-bladed turbo fan. The mean-line analysis, cascade theory, and CFD technique are all together applied to control the passage areas on the meridional plane from the inlet to the exit of the blade. Furthermore, the torque control algorithm is adopted to improve the performances within the constraints by the motor rpm-torque characteristics, and the resulting measured performances of mock-up fans are discussed.

  • PDF

변풍량(變風量)시스템의 에너지해석(解析)에 관(關)한 연구(硏究) (Energy Analysis for Variable Air Volume System)

  • 박병규;조동우;신현준
    • 대한설비공학회지:설비저널
    • /
    • 제17권5호
    • /
    • pp.575-582
    • /
    • 1988
  • This paper presents an energy analysis on the VAV system of 10-story building in Seoul using DOE-2 program and Modified Bin Method. The use of VAV system is an excellent means of saving energy in new buildings and/or retrofit. The fan control techniques considered are cycling, discharge dampers, inlet vanes, and motor speed control. The monthly and annual energy consumption is calculated for fan control techniques, components, and chiller types. The results of annual fan electricity use are compared using DOE-2 and Modified Bin Method, and show fairly good agreement. In addition, factors affecting energy consumption are also described.

  • PDF

자속 집중형 모터를 이용한 팬 모터의 성능개선 설계 (Performance Improved Design of Fan Motor using Flux Concentration Type Motor)

  • 정재웅;이성구;이주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.720-721
    • /
    • 2015
  • 본 논문에서는 팬 모터의 성능개선 설계를 위하여 기존 표면 부착형 팬 모터를 자속 집중형으로의 개선, 변경 하는 연구를 진행하고 설계하였다. 성능 개선을 확인하기 위하여 역기전력과 Set 소비전력 측정을 진행하였다. 이러한 계측을 통하여 자속 집중형 모터의 모터 특성이 표면 부착형 대비 동등 이상임을 확인 하였다. 이에 더하여 중량 및 제조 비용까지 절감 하였다.

  • PDF

송풍기용 단상 SRM의 구동특성 (Driving Characteristics of Single Phase Switched Reluctance Motor for Fan Application)

  • 김봉철;안진우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(2)
    • /
    • pp.848-851
    • /
    • 2003
  • This paper proposes a new driving scheme for single-phase SRM. The driving scheme is very simple and inexpensive. By use of this scheme, simple power devices based on low switching losses enable to high efficiency SRM drive. Starting, One of the main problem in single-phase SRM is overcame by a new starting algorithm with one hall sensor and a parting magnet. The proposed single phase SRM has a high efficiency and robust drive characteristics compared to that of a universal motor.

  • PDF

대형 수직전동기 Cooler Housing의 이상소음 제어 (A Noise Control of Cooler Housing in Large Scale Vertical Motor)

  • 주원호;김동해
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 추계학술대회논문집
    • /
    • pp.132-137
    • /
    • 2000
  • Recently, a severe noise problem was encountered during a shop test of large scale vertical motor. In order to identify the noise characteristics and propose the countermeasure, a variety of experiments such as sound excitation test and contribution analysis was earned out in addition to ordinary noise and vibration measurements. The results showed that the severe noise level was dominated by an acoustic resonance phenonmenon in the cooler housing and higher sound power of outer fan. Through proper treatments, the noise level could be acceptable.

  • PDF

Aeroacoustic Characteristics and Noise Reduction of a Centrifugal Fan for a Vacuum Cleaner

  • Jeon, Wan-Ho;Rew, Ho-Seon;Kim, Chang-Joon
    • Journal of Mechanical Science and Technology
    • /
    • 제18권2호
    • /
    • pp.185-192
    • /
    • 2004
  • The aeroacoustic characteristics of a centrifugal fan for a vacuum cleaner and its noise reduction method are studied in this paper. The major noise source of a vacuum cleaner is the centrifugal fan. The impeller of the fan rotates at over 30000 rpm, and generates very high-level noise. It was revealed that the dominant noise source is the aerodynamic interaction between the rotating impeller and stationary diffuser. The directivity of acoustic pressure showed that most of the noise propagates backward direction of the fan-motor assembly. In order to reduce the high tonal sound generated from the aerodynamic interaction, unevenly pitched impeller and diffuser, and tapered impeller designs were proposed and experiments were performed. Uneven pitch design of the impeller changes the sound quality while the overall sound power level (SPL) and the performance remains similar. The effect of the tapered design of impeller was evaluated. The trailing edge of the tapered fan is inclined. This reduces the flow interaction between the rotating impeller and the stationary diffuser because of some phase shifts. The static efficiency of the new impeller design is slightly lower than the previous design. However, the overall SPL is reduced by about 4 dB(A). The SPL of the fundamental blade passing frequency (BPF) is reduced by about 6 dB (A) and the 2$\^$nd/ BPF is reduced about 20 dB (A). The vacuum cleaner with the tapered impeller design produces lower noise level than the previous one, and the strong tonal sound was dramatically reduced.

유한요소법을 이용한 쿨링팬의 진동 및 간섭에 관한 연구 (A Study on Resonance and Interference of a Cooling Fan Assembly by Using FEM)

  • 정일호;송하종;박태원;김주용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 춘계학술대회논문집
    • /
    • pp.919-924
    • /
    • 2004
  • A CFA(Cooling Fan Assembly) is composed of a fan, motor and shroud, which is at the back of the automotive radiator. By forcing the wind to pass, the CFA controls the cooling performance of the radiator. The noise and vibration of the CFA may be primarily due to the resonance between the CFA and engine. The Interference among the fan, shroud and radiator by deformation is considered when the CFA is designed. In this paper, in order to analyze the structural vibration of the CFA for automobiles, a finite element model of the CFA is established by using a commercial FEM code. After the finite element modeling, the natural frequencies and the mode shapes are obtained from the FE analysis. The natural frequencies are obtained from the vibration test as well. Then, the results of the vibration test are compared with those of the FE analysis. The natural frequencies obtained by experiment have a great similarity to the results from FE model. We have confirmed the validity of the FE model and verify the structural safety for the resonance. The stress and displacements are obtained from FE analysis. We have confirmed the safety for the interference and failure.

  • PDF

레인지 후드용 시로코 홴의 성능 향상을 위한 연구 (Numerical study on the Performance Improvement of the Sirocco Fan in a Range Hood)

  • 박상태;최영석;박문수;김철호;권오명
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2004년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.572-577
    • /
    • 2004
  • This paper presents numerical study on the performance improvement of the sirocco fan in a range hood. The performance of sirocco fan means a higher flowrate, a higher static pressure and a lower required motor power in a fixed geometry constraint. Various impeller geometric parameters, such as blade profile, blade diameter, blade thickness profile and blade exit angle, were investigated by numerically and the results were compared with each other to know the effects on the performance. In this approach, the volute geometry were fixed with the original shape. The numerical results show that the blade profile with airfoil shape and small exit blade thickness increases the performance. The blade exit angle shows optimum angle within a varied range. The efficiency of the optimized exit angle was about $10\%$ higher than the base blade exit angle and the static pressure was about $28\%$ higher at the flow coefficient 0.22.

  • PDF

차량용 공조 팬의 소음 저감에 대한 실험적 연구 (Experimental Study on Noise Reduction of Fan for Automotive Air Conditioner)

  • 이진갑;정병훈
    • 한국산학기술학회논문지
    • /
    • 제14권1호
    • /
    • pp.51-56
    • /
    • 2013
  • 본 논문은 철도 차량에 사용하는 라인 플로우 팬의 소음 저감을 위해 소음원을 규명하여 저감하는 실험적인 연구이다. 라인 플로우 팬의 소음은 공기 유동에 의한 난류성 유동 및 랜덤성 소음, 블레이드 통과 주파수(681Hz)의 소음, 모터 회전에 의한 로터의 불균형(28.4Hz)의 구조물 진동에 의한 소음 등 여러 요인에 의해 발생된다. 각각의 소음원에 대해 대책을 수립하여 하우징 가이드 각도 및 거리 조정, 유동 통로의 형상 변경, 로터 밸런싱을 통해 총 5.7dB(A)의 소음을 저감하였다.