• 제목/요약/키워드: Fan system

검색결과 1,108건 처리시간 0.028초

축사 환기팬 후류의 풍에너지 평가 및 기류 형상의 전산유체역학 모델링 (Evaluation and CFD Modelling of Flow behind Livestock Ventilation Fan for Small-Scale Wind Power Generation)

  • 홍세운;이인복;서일환;권경석;하태환;황현섭
    • 한국농공학회논문집
    • /
    • 제54권5호
    • /
    • pp.79-89
    • /
    • 2012
  • The objectives of this paper were to evaluate the wind flow behind the livestock ventilation fan for small-scale wind power generation and to make flow profiles of imaginary ventilation fan for future simulation works. The field experiments using typical 50-inch fan indicated that the wind flow behind the ventilation fan had a good possibility of power generation with its high and steady wind speeds up to a distance of 2 m. The expected electricity yield was almost 101~369 W with a small (0.8 m radius) wind turbine. The decline of ventilation fan performance caused by the obstacle was also not significant with about 4 % from a distance of 2 m. The flow profiles for the computational fluid dynamics (CFD) simulation was created by combining the direction vectors analyzed from tuft visualization test and the flow predicted by the rotating fan modeling. The flow profiles are expected to provide an efficient saving of computational time and cost to design a better wind turbine system in future works.

최대유량역에서 소형 축류 홴의 3차원 난류유동 특성에 관한 연구 (A Study on the Three-Dimensional Turbulent Flour Characteristics of a Small-sized Axial Fan at the Maximum Flowrate Region)

  • 김장권
    • 동력기계공학회지
    • /
    • 제4권3호
    • /
    • pp.25-33
    • /
    • 2000
  • This study represents three-dimensional turbulent flow characteristics around an axial fan measured at the operating point ${\varphi}=0.32$, which is equivalent to the maximum flowrate region, by using three-dimensional fiber-optic type LDA system. This LDA system is composed of a 5 W Argon-ion laser, two optics in back-scatter mode, three BSA's, a PC, and a three-dimensional automatic traversing system. A kind of paraffin fog is used for laser particles in this study. Mean velocity profiles around an axial fan along the downstream radial distance show that the streamwise and the tangential components exist as a predominant velocity and have the maximum value at the radial distance ratio 0.8, while the radial component has a small scale distribution and its flow direction is inward except a part of blade tip. The turbulent intensity profiles show that the radial component exists the most greatly. And also the turbulent kinetic energy shows about 60% as a maximum value at the radial distance ratio 0.9. Moreover, the Reynolds shear stresses do not exist at upstream flow, but the streamwise and the radial components of them show about 20% as a maximum value at the radial distance ratio 0.9 at downstream flow.

  • PDF

저소음 HDD 구현을 위한 동작 알고리즘에 관한 연구 (A Study of Working Algorithm which makes silent Hard Disk Drive)

  • 변상돈;정기현
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2010년도 춘계학술대회
    • /
    • pp.274-276
    • /
    • 2010
  • 노트북 시스템의 소음 원으로는 크게 3가지가 있는데 HDD, System Cooling Fan 그리고 ODD로 나뉠 수 있다. 이 중 HDD를 제외한 다른 두 가지는 사용자가 소음을 인지하고 받아들이는데 무리가 없지만 HDD는 소음 발생 이유를 납득하기가 어렵다. 즉, System Fan은 CPU와 Chipset의 온도를 낮추어야 하니 반드시 필요한 소음으로 인지하고, ODD는 필요시에만 동작하여 소음을 발생하니 소음이라고 생각하지 않는다. 하지만 HDD의 경우 사용자가 HDD를 Access하지 않아도 Disk 작업이 발생하는 경우가 있는데(캐쉬 정리, Defragmentation 등) 이 때에는 사용자가 소음을 납득하지 않는다. 더군다나 도서관이나 새벽의 방 안에서처럼 조용한 환경에서 사용 시에는 더욱 더 소음이 두드러져 사용자의 불만을 야기하게 된다. 이에 사용자가 소음에 대해 거부감을 갖지 않고 HDD의 감성불만인 소음에 대해 Claim을 제기하지 않도록 HDD의 소음 수준을 낮추는 알고리즘을 개발하고 적용하는 방법에 대해 연구한다.

  • PDF

T-method를 이용한 고층 아파트 욕실 배기 시스템의 층별 유량분배 해석 (Analysis of Air Flow Rate Distribution for the Bathroom Exhaust System in High-rise Buildings Using T-method)

  • 문종선;강석윤;이승철;유호선;이재헌
    • 설비공학논문집
    • /
    • 제16권3호
    • /
    • pp.265-272
    • /
    • 2004
  • Based on the T-method, a new scheme for predicting air flow rate distribution in a bathroom exhaust system is developed. Introduction of individual duct route enables us to disintegrate a complicated multi-fan ductwork into a set of simultaneous single-fan subsystems. The scheme is validated via the analysis of a well-posed test problem, showing physical consistency. In order to demonstrate the utility and capability of our method, the bathroom ventilation system in a 20-story residential building is selected as an example. Under the typical design condition, the air flow rate of each exhaust fan at the balancing point is successfully predicted, and such information can lead to an engineering estimation for the overall system performance. While some deficiencies in ventilation are found at bathrooms at lower floors with 6mmAq-rated exhaust fans, they disappear over the whole building by using fans of enhanced static pressures, 7 and 8mmAq. Finally the present scheme seems to be useful for practical design of multi-branched, multi-fan ventilation systems.

유도전동기 시스템의 동특성 연구 (A Study on Dynamic Characteristics of Induction Motor System)

  • 이형우
    • 한국정밀공학회지
    • /
    • 제23권5호
    • /
    • pp.128-136
    • /
    • 2006
  • To predict the noise and vibration characteristics of induction motor system, it is necessary to develop the mathematical model including all the mechanical elements such as shaft, blower, rotor, fan, bearing, case and mounting parts. Coupling effect between case-mount system and rotor- shaft system including shaft, blower, rotor, fan and bearing is examined. Impact exciting experimentation was done in order to verify vibration model of the induction motor system. From experimental results, we can appreciate that the natural frequencies of induction motor system are in good agrements with analysis.

버섯재배사의 공조시스템 설계에 대한 연구 (A study on the design of air conditioning system in the mushroom cultivation greenhouse)

  • 류경진;손재환;한창우;나규동
    • 한국산학기술학회논문지
    • /
    • 제18권2호
    • /
    • pp.743-750
    • /
    • 2017
  • 온실에서 버섯을 재배할 때 균일한 온도 분포가 되도록 하는 것이 중요하다. 지하 공기를 이용하여 비닐 하우스, 버섯재배사에 일정 온도의 공기를 공급하며 균일하게 유지하게 한다. 버섯재배사 구조는 7단 4열의 다배열 균상들 사이의 공기 흐름을 원활히 하고 위, 아래 균상 간의 환경 차이를 방지한다. 0.5m/s의 속도로 유입되는 공기는 초기 내부온도 간의 차이에 따라 밀도 차에 따른 부력에 의한 효과 역시 무시할 수 없으며, 온실내의 유동 해석을 통해 적정 온도가 균등하게 분포하도록 FCU(Fan Coil Unit)와 Fan의 위치를 정해야 한다. 본 연구에서는 유동해석을 통해 FCU와 Fan으로 구성된 샌드위치 단열 패널형의 버섯재배사의 공조시스템을 설계할 수 있었다. 그리고 재배사 내부의 온도 및 유동 해석을 통해 FCU(유입구)와 Fan(출구)의 위치가 서로 다른 Case에서 유입되는 공기의 순환 경로가 길어지면서 비교적 균일한 온도분포를 갖는데 유리함을 알 수 있었다. 따라서 이러한 환경 개선을 통해 버섯의 생육 및 품질 균일성을 도모할 수 있었다.

팬 모터 구동을 위한 집적화된 홀 센서 IC의 제작 및 특성 (Fabrication and Characteristics of the Integrated Hall Sensor IC For Driving Fan Motors)

  • 이철우
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 하계종합학술대회 논문집(2)
    • /
    • pp.73-76
    • /
    • 2002
  • In this paper we present an integrated Hail sensor It for fan motors, fabricated in industrial bipolar process. As a discrete Hall sensor and signal processing circuitry In the fan motor system were Integrated into single chip a temperature dependence of Hall sensitivity and Hall offset voltage can be compensated and cancelled by on-chip circuitry. We Propose a novel temperature compensation of Hall sensitivity with negative temperature coefficient (TC) using the differential amplifier gain with Positive TC. After a package of the chip was sealed using a plastic Package 20 Pins, the thermal and magnetic characteristics were investigated. The obtained experimental results are in agreement with analytical predictions and have more excellent performance than\ulcorner conventional the fan motor system using discrete Hall sensor.

  • PDF

에어컨 실내기 터보팬의 소음 저감 (Noise Reduction of Turbo Fans for Air-Conditioner Indoor Units)

  • 김진백;최원석;구형모;이재권
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 춘계학술대회논문집
    • /
    • pp.93-96
    • /
    • 2004
  • A turbo-fan for the 4-way cassette indoor units of air-conditioners has been investigated. The main purpose of this investigation is the reduction of the turbo-fan noise. In order to reduce the noise level, many design parameters of turbo-fans such as blade section, blade thickness, geometry of blade leading edge, blade width, blade angle and bellmouth depth have been studied. With the experimental data of these parameters, a new turbo-fan was made for our system. The noise level of the new system was at least 3 dB(A) lower than that of the current in use.

  • PDF