• 제목/요약/키워드: Fan speed

검색결과 316건 처리시간 0.027초

인자 분석을 통한 플라즈마 디스플레이 패널(Plasma Display Panel) 텔레비전에서의 냉각 홴 시스템 소음 저감 (Noise Reduction of PDP TV Cooling Fan System through Parameter Analysis)

  • 김규영;최민구;이덕주
    • 한국소음진동공학회논문집
    • /
    • 제16권2호
    • /
    • pp.107-114
    • /
    • 2006
  • The present experimental study deals with noise reduction and improvements in cooling performance in a plasma display panel (PDP) television (TV). The main ideas of the fan system noise reduction are maintenance of uniform inflow condition and reduction of the system loss, ${\Delta}P.$ The discrete noise is mainly related with the inflow condition therefore removing the structure which distorts inflow makes the discrete noise reduction. The broadband noise in PDP TV is related with the system losses which result from the presence of the fan downstream obstacle, PDP rear case. Through the modification of the distance and preventing the leakage flow between the fan and rear case, we can obtain the system loss and broadband noise reduction. Additionally we can reduce fan rotating speed because of increased flow rate which obtains from the reduction of system loss (resistance). Finally, 4.2 dB(A) noise reduction and $10\%$ increase in flow rate are achieved. From these results, we show that the reduction of system loss is the most effective way of the fan system noise reduction.

청소기용 터보홴의 비정상 유동장 및 공력소음 해석 (An Analysis of the Unsteady Flow-Field and Aerodynamic Sound of a Turbo Fan used in a Vacuum Cleaner)

  • 전완호;김창준;류호선
    • 한국유체기계학회 논문집
    • /
    • 제5권2호
    • /
    • pp.36-42
    • /
    • 2002
  • A new method to calculate the aeroacoustic pressure of a centrifugal fan that is used in a vacuum cleaner has been developed. The centrifugal fan consists of the impeller, the diffuser, and the circular casing. Due to the high rotating speed of the impeller and the small gap distance between the impeller and diffuser, the centrifugal fan makes very high noise levels at BPF and its harmonic frequencies. In order to calculate the sound pressure of a centrifugal fan, the unsteady flow field data is needed. This unsteady flow field is calculated by the vortex method. The sound pressure is then calculated by acoustic analogy. In this paper, only dipole term is considered in the equation. The noise generated by moving impeller and stationary diffuser is calculated separately. The predicted acoustic pressures agree very well with the measured data. The difference between the two is less than 4dB

발전소 대용량 FD Fan 전동기의 교류 가변속 장치 (VVVF) 적용에 관한 연구 (Research Study on the Application of AC Adjustable speed Drive for FD Fan Motor in power plant.)

  • 허성광;류홍우;한경희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 B
    • /
    • pp.1203-1205
    • /
    • 1992
  • Due to poor energy resources, the importance of energy saving has been greatly emphasized. It can be one method of energy saving to reduce the power. The AC adjustable speed drive systems show excellent efficiency, which have been developed in recent years. The adjustable speed drive system improves the efficiency in lightly load condition and extend the life span of motor by limiting the over-current at starting. The main topic of study is the results of energy saving and emergency transfer.

  • PDF

대기 조건에 따른 공랭식 응축기 성능 저하 개선 연구 (Study on Performance Improvement Air Cooled Condenser Considering Ambient Condition)

  • 차훈;류광년;김정래
    • 대한기계학회논문집 C: 기술과 교육
    • /
    • 제3권3호
    • /
    • pp.201-207
    • /
    • 2015
  • 공랭식 응축기(ACC, Air Cooled Condenser)는 공기를 냉매로 이용하여 저압 스팀을 응축하는 설비로써 사막이나 내륙 등 물이 부족한 지역에서 주로 사용된다. 공랭식 응축기의 성능은 풍속이나 대기온도와 같은 외기 조건에 의해 크게 영향을 받으므로 성능 저하 개선을 위해 여러 장치들이 설치된다. 본 연구에서는 풍속에 의한 ACC 성능 변화를 확인하고 윈드 스크린에 의한 성능 개선 효과를 분석하기 위해 CFD 해석을 수행하였다. CFD 는 질량 보존, 운동량 보존 등 미분방정식을 차분방정식으로 변환하여 검사 체적에 대해 속도, 온도 등을 계산하는 기법이다. 풍속이 3m/s 에서 7m/s 로 상승할 때, ACC 에 설치된 팬 공급 유량은 약 15.76% 감소하며 ACC 유입 공기 온도는 $5.55^{\circ}C$ 증가한다. 윈드 스크린을 적절히 설치한 경우, 풍속이 7m/s 이고 윈드 스크린이 설치되지 않은 경우에 비해 팬 공급 유량이 약 5.18% 증가하며 ACC 유입 공기 온도 상승은 $2.08^{\circ}C$ 감소하는 효과가 있다.

부분부하 조건에서 히트펌프의 운전변수 최적화를 통한 냉방계절성능(SEER) 향상에 관한 실험적 연구 (An Experimental Study on the Performance Improvement of the Seasonal Energy Efficiency Ratio(SEER) of a Heat Pump by Optimizing Operating Parameters under Partial Load Conditions)

  • 최성경;이상헌;김선재;김용찬
    • 설비공학논문집
    • /
    • 제29권3호
    • /
    • pp.111-118
    • /
    • 2017
  • Performance factors such as the EER(Energy Efficiency Ratio) and the COP (Coefficient of Performance) are being replaced by seasonal energy efficiency factors, like the SEER (Seasonal EER) and the SCOP (Seasonal COP) to evaluate the performance of a heat pump by the time of the year. Seasonal performance factors, such as the CSPF (Cooling Seasonal Performance Factor) and the HSPF (Heating Seasonal Performance Factor) are used to describe the heat pump's performance during the cool and hot seasons. In this study, the optimization of all heat pump's operating parameters was experimentally conducted to enhance the SEER based on the EU standard (EN 14825). Moreover, the SEER was improved by the compressor frequency, as well as indoor and outdoor fan speeds. In addition, the performance characteristics of the heat pump were studied under partial load conditions. As a result, the SEER was enhanced by 17% when the compressor frequency was optimized. An additional 2% improvement was achievable with the optimization of indoor and outdoor fan speeds.

수치해석적 기법을 이용한 횡류홴 성능 평가 (Performance Estimation of Cross-Flow Fan by Numerical Method)

  • 김동원;이준화;박성관;김윤제
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2002년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.152-157
    • /
    • 2002
  • A cross-flow fan is widely used on many industrial fields: a blower for the general industry, mining industry, automobile and home appliances. The design point of the cross-flow fan is generally chosen by based on the region within low static pressure and high flow rate. It relatively makes high dynamic pressure at low speed because a working fluid passes through an impeller blade twice. However, it has low static pressure efficiency between $30\%$ and $40\%$ because of relative high impact loss. Recently, in the air-conditioning systems, the operating behaviors at the off-design points are highly regarded to broaden the application area for various air-cooling loads. Especially, at the low flow rate, there exists a rapid pressure head reduction, a noise increase and an irregular flow against a rearguider as a scroll of centrifugal fan. Numerical analyses are carried out for cross-flow fan including the impeller, the rearguider and the stabilizer. Numerical domains are discretized by hexahedral cells. Three-dimensional, unsteady governing equations are solved using FVM, SIMPLE algorithm, sliding grid system and standard k-$\epsilon$ turbulence model.

  • PDF

진공청소기용 원심팬 주위의 유동해석을 통한 성능개선 (THE PERFORMANCE IMPROVEMENT OF VACUUM CLEANER BY ANALYSIS OF THE FLOW AROUND CENTRIFUGAL FAN)

  • 박진우;기민철;박형구
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2007년도 추계 학술대회논문집
    • /
    • pp.82-87
    • /
    • 2007
  • A cleaner has trouble with too much noise and power consumption. To solve these problems, the investigation for motors, which are the main component of vacuum cleaner, is required. However, it is difficult to analyze the flow by the experimental means because of the high speed of the fan rotation ranging from 30,000 rpm to 50,000 rpm. Moreover it takes much time to perform the numerical simulation for the flow. In this research, it is aimed to analyse the flow through the centrifugal fan which is believed to be a main noise source, by the computational method. The efficiency of the centrifugal fan is affected by friction loss, shock loss and so on. Those losses depend on factors like the velocity of impeller, blade shape and etc. Accordingly, the influence of the shape of impeller on the flow is investigated in this study. The computational analysis was done by changing impeller shapes. The flow around the centrifugal fan is simulated by applying the moving mesh. To verify the validity of the computation results, the air flow rate and the pressure field to the cleaner is compared with the experimental data. All simulations are performed by using commercial code SC/Tetra. The calculated results show good agreement with the experimental ones qualitatively and it is believed to be promising to use computational simulation in the improvement of the vacuum cleaner performance.

  • PDF

진공청소기 흡입효율 개선을 위한 모터 주위의 유동해석 (Performance Improvement of a Vacuum Cleaner by CFD Analysis around Motor)

  • 박진우;기민철;박형구
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.522-525
    • /
    • 2008
  • A vacuum cleaner is the widely used home equipment. However, it has a trouble with too much power consumption. Most losses occur at the centrifugal fan. To remedy this trouble the investigation of motor, which is the main component of vacuum cleaner, is required. The flow characteristics around the high-speed rotating centrifugal fan which is influenced by the very low inlet pressure is quite different from a commonly used fan. Hence it is quite difficult to analyze the flow by the experimental means or by the numerical simulation. In this research, it is aimed to improve the air-suction performance of a vacuum cleaner through the flow analysis around a motor. The efficiency of the centrifugal fan is affected by blade shape, blade number, blade pitch, etc. The influence of the shape of impeller on the flow is investigated in this study. The flow around the centrifugal fan is simulated by applying the moving mesh. To verify the validity of the computation results, the air flow rate and the pressure field to the cleaner is compared with the experimental data. All simulations are performed by using commercial code SC/Tetra. The calculated results show good agreement with the experimental ones and it is believed to be promising to use computational simulation in the improvement of the vacuum cleaner performance.

  • PDF

Performance and Flow Condition of Contra-rotating Small-sized Axial Fan at Partial Flow Rate

  • Shigemitsu, Toru;Fukutomi, Junichiro;Okabe, Yuki;Iuchi, Kazuhiro
    • International Journal of Fluid Machinery and Systems
    • /
    • 제3권4호
    • /
    • pp.271-278
    • /
    • 2010
  • Small-sized axial fans are used as air cooler for electric equipments. But there is a strong demand for higher power of fans according to the increase of quantity of heat from electric devices. Therefore, higher rotational speed design is conducted, although, it causes the deterioration of efficiency and the increase of noise. Then the adoption of contrarotating rotors for the small-sized axial fan is proposed for the improvement of performance. In the present paper, the performance curves of the contra-rotating small-sized axial fan with 100mm diameter are shown and the velocity distributions at a partial flow rate at the inlet and the outlet of each front and rear rotor are clarified with experimental results. Furthermore, the flow conditions between front and rear rotors of the contra-rotating small-sized axial fan are investigated by numerical analysis results and causes of the performance deterioration of the contra-rotating small-sized axial fan at the partial flow rate is discussed.

산업용 Turbo형 송풍기의 Cutoff 각도에 따른 유동특성 (Flow Characteristics due to Cutoff angle of Turbo-Fan for Industries)

  • 윤지훈;정인국;이중섭;서정세
    • 한국기계가공학회지
    • /
    • 제10권5호
    • /
    • pp.91-96
    • /
    • 2011
  • This study aims to analyze the flow characteristics of turbo-fan which is applied to the industrial field. Numerical analysis has been carried out to investigate the pulsation behavior of exhaust air flown out turbo fan by rotating impeller with constant speed. Moving mesh technique is proved as time-accurate solution for the flow inside impeller. As numerical results come within the error range of 1% by comparing with theoretical results, the numerical analysis can be verified. Cutoff angle has large influence on the amplitude of pulsation and the least pulsation of flow can be generated by the cutoff angle of $20^{\circ}$.