• Title/Summary/Keyword: Fan performance

Search Result 908, Processing Time 0.024 seconds

A Study on the Viewing Experience and Performance of Professional Baseball Team: The Team Performance Side and the Fan Performance Side

  • Byun, Kyung-Won
    • International journal of advanced smart convergence
    • /
    • v.10 no.1
    • /
    • pp.166-175
    • /
    • 2021
  • The purpose of this study is to analyze the structural relationship among fan experience, fan satisfaction, team attachment, psychological well-being, team loyalty and quality of life. Specifically, the structural equation model is analyzed for the team performance side leading to fan experience-fan satisfaction-team attachment-team loyalty and the an performance side leading to fan experience-fan satisfaction-psychological well-being-quality of life. The survey to achieve the goal of this study is a professional baseball fan. 150 pilot envestigation and 348 main envestigation were selected as the final effective samples. Data processing was done with SPSS 23 for frequency analysis, exploratory factor analysis and reliability analysis. Also, AMOS 21 was used for confirmatory factor analysis and structural equation model analysis. The results of the analysis are as follows: First, fan experience had a positive effect on the fan satisfaction. Second, fan satisfaction had a positive effect on the team attachment. Third, fan satisfaction had a positive effect on the psychological well-being. Fourth, team attachment had a positive effect on theteam loyalty. Fifth, psychological well-being had a positive effect on the quality of life.

Development of a High-efficiency and Low-noise Axial Flow Fan through Combining FanDAS and CFX codes (FanDAS-CFX 결합을 통한 고효율-저소음 축류 송풍기의 개발)

  • Lee, Chan;Kil, Hyun Gwon;Noh, Myung-Keun
    • The KSFM Journal of Fluid Machinery
    • /
    • v.15 no.5
    • /
    • pp.37-41
    • /
    • 2012
  • High-efficiency and low-noise axial flow fan is developed by combining the FanDAS, a computerized axial fan design/performance analysis system, and CFD software(CFX). Based on fan design requirements, FanDAS conducts 3-D blade geometry design, quasi-3D flow/ performance analyses and noise evaluation by using through-flow analysis method and noise models for discrete frequency and broadband noise sources. Through the parametric studies of fan design variables using FandDAS, preliminary and baseline design is achieved for high efficiency and low noise fan, and then can be coupled with a CFD technique such as the CFX code for constructing final and optimized fan design. The FanDAS-CFX coupled system and its design procedure are applied to actual fan development practice. The FanDAS provides an optimized 3-D fan blade geometry, and its predictions on the performance and the noise level of designed fan are well agreed with actual test results.

Experimental Study on Performance Characteristics with Various Spacings between Automobile Cooling Fan and Engine Block (차량용 냉각 팬과 엔진 블럭의 간격 변화에 따른 성능 특성 연구)

  • Yu, Byoung-Min;Ryu, Ki-Wahn;Jang, Jea-Kyung;Ih, Kang-Duck;Hong, Sung-Kyu
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.10a
    • /
    • pp.143-149
    • /
    • 2009
  • Recently, according to the tendency to the more comfortable automobile, the improvement of performance of the cooling fan is required. The performance of cooling fan is affected by many peripheral parts, such as radiator, condenser, engine block and etc. Therefore, it is important to consider the effect of peripheral components on the fan performance in design and analysis stages. In this paper, the performance of automobile cooling fan is investigated experimentally by using the large capacity fan tester based on the ASHRAE and the AMCA standards. In particular, the various spacing between cooling fan and engine block are considered to obtain the effect of engine block. An empirical relation between the fan flow rate and the spacing was proposed.

  • PDF

A study on Low-Noise and High-Efficiency Sirocco Fan Development (저소음 고효율 시로코 홴 개발에 관한 연구)

  • Park, Kwang-Jin;Lee, Sang-Hwan;Son, Byung-Jin
    • The KSFM Journal of Fluid Machinery
    • /
    • v.2 no.2 s.3
    • /
    • pp.46-56
    • /
    • 1999
  • This study is on the performance prediction and design of a sirocco fan. Slip coefficient is very important factor for the performance analysis of a centrifugal-type fan. Because generally used slip coefficient equations of backward curved centrifugal fan are not appropriate for forward curved sirocco fan, in this study a proper slip coefficient equation for a sirocco fan is suggested. Using this equation performance prediction program for sirocco fan is composed of and also included the total noise prediction that include the turbulent noise at the fan inlet and boundary layer noise. A comparison between the values obtained from performance prediction program and experimental values shows that the program predicts the sirocco fan performance in a practical rate.

  • PDF

A study on low-noise and high-efficiency sirocco fan development (저소음 고효율 시로코 팬 개발에 관한 연구)

  • Park, K.J.;Lee, S.H.;Son, B.J.
    • 유체기계공업학회:학술대회논문집
    • /
    • 1998.02a
    • /
    • pp.63-72
    • /
    • 1998
  • This study Is on the performance prediction and design of sirocco fan. Slip coefficient is very important factor for the performance analysis of centrifugal-type fan. Because generally used slip coefficient equations of backward curved centrifugal fan are not appropriate for forward curved sirocco fan, in this study a proper slip coefficient equation for sirocco fan is suggested. Using this equation performance prediction program for sirocco fan is composed and also included the total noise prediction that include turbulent noise at the fan Inlet and boundary layer noise. A comparison between the values obtained from performance prediction program and experimental values shows that the program predicts the sirocco fan performance in a practical rate.

  • PDF

The Operation and Vibration Characteristics of Tail-Fan Performance Test System (테일팬 성능시험장치의 운용과 진동특성)

  • Song, Ken-Woong;Kim, Jun-Ho;Kang, Hee-Jung;Rhee, Wook;Sim, Jung-Wook
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.508-512
    • /
    • 2004
  • This paper described operation and vibration characteristics of 'Tail-Fan' performance test system. KARI(Korea Aerospace Research Institute) developed 'Tail-Fan' system as a kind of helicopter anti-torque system(ATS) and designed ATS performance test-rig for Tail-Fan system performance test. Test-rig consists of driving parts, supporting parts and rotating parts. For Tail-Fan system performance tests, firstly, test-rig operation tests were carried out for verification of design specifications. Secondly, natural frequencies of fan blade and test-rig were measured respectively. Lastly, to find the operation rotating speed for performance tests, vibration tests using accelerometers on tail gear box(TGB) were carried out. Through the fanplot and vibration test results, Tail-Fan performance test conditions to avoid a resonance were found and performance tests were well done safely.

  • PDF

A Numerical Investigation of Flow and Performance Characteristics of a Small Propeller Fan Using Viscous Flow Calculations

  • Oh, Keon-Je;Kang, Shin-Hyoung
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.3
    • /
    • pp.386-394
    • /
    • 2002
  • The present work is aimed at investigating an unusual variation in flow and performance characteristics of a small propeller fan at low flow rates. A performance test of the fan showed dual performance characteristics, i.e., radial type characteristics at low flow rates and axial type at high flow rates. Dual performance characteristics of the fan are numerically investigated using viscous flow calculations. The Finite Volume Method is used to solve the continuity and Navier-Stokes equations in the flow domain around a fan. The performance parameters and the circumferentially averaged velocity components obtained from the calculations are compared with the experimental results. Numerical values of the performance parameters show good agreement with the measured values. The calculation simulates the steep variations of performance parameters at low flow rates and shows the difference in the flow structure between high and low flow rates. At a low flow coefficient of $\Phi$=0.2, the flow enters the fan in an axial direction and is discharged radially outward at its tip, which is much like the flow characteristics of a centrifugal fan. The centrifugal effect at low flow rates makes a significant difference in performance characteristics of the fan. As the inlet flow rate increases, flow around the fan changes into the mixed type at $\Phi$=0.24 and the axial discharge at $\Phi$=0.4.

The Study on Performance of Propeller Fan according to Distance of Front Plate (프로펠라 팬과 앞판과의 간격이 팬 성능에 미치는 영향에 관한 연구)

  • 엄윤섭;부정숙;윤인철
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.24 no.4
    • /
    • pp.494-501
    • /
    • 2000
  • A study on performance of a propeller fan according to the distance between the front plate and the fan was conducted experimentally. Different characteristics of performance were found on the performance curve. Flow measurements using the three dimensional LDV system show that the zone of recirculation exists around the fan. The differences of performance in changes of the distance occurs because the zone of recirculation is much wider at the distance of 24mm than at that of 30mm.

  • PDF

Experimental and Numerical Studies on the Flow Characteristics of a Fan-Sink (팬싱크의 유동 특성에 관한 실험 및 수치해석적 연구)

  • Lee Kyoung-Yong;Choi Young-Seok;Yun Jae-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.3
    • /
    • pp.225-230
    • /
    • 2006
  • The overall performance and local flow fields of the fan, heat sink, and fan-sink were experimentally and numerically studied to investigate the flow characteristics of a fan-sink. The flow resistance of the heat sink was measured by small fan tester based on AMCA standards and compared with the CFD results to select available cooling fan for the fan-sink. The nonuniform velocity profile behind the fan outlet was shown by the flow visualization. The effects of nonuniform velocities on the performance of heat sink were discussed. To validate the commercial CFD code CFX-5.6, the predicted performance curve was compared with that of fan testing. The local flow fields of the fan-sink were analyzed by CFD results. MFR (multiple frame of reference) was used as a computational model combining rotating fan and stationary heat sink. Through the CFD results of the fan-sink, the flow patterns behind the fan outlet influenced the flow resistance and overall performance of the heat sink.

The Operation and Vibration Characteristics of Tail-fan Performance Test System (테일홴 성능시험장치의 운용과 진동특성)

  • Song, Keun-Woong;Kim, Jun-Ho;Kang, Hee-Jung;Rhee, Wook;Sim, Joung-Wook
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.4 s.97
    • /
    • pp.421-428
    • /
    • 2005
  • This paper described operation and vibration characteristics of a 'tail-fan' anti-torque performance test system. KARI (Korea Aerospace Research Institute) developed a 'tail-fan' anti-torque system of a helicopter and a performance test-rig to test the performance of the tail-fan. The performance test-rig consists of driving, supporting and rotating parts. In the process of the performance test, firstly, operation test of the test-rig were carried out to verify design specifications. Secondly, natural frequencies of fan blade and test-rig were measured respectively. Lastly, to find the operation rotating speed for the performance test, vibration test were carried out using accelerometers on tail gear box. The performance test conditions of the tail-fan to avoid a resonance were found from the fan-plot and vibration test results. The tail-fan performance tests were well done safely.