• Title/Summary/Keyword: Fan flow performance

Search Result 420, Processing Time 0.04 seconds

Optimum Design of a Cross Flow Fan (횡류팬의 최적설계방안)

  • Kim Dong-Hoon;Park Hyung-Koo
    • Journal of computational fluids engineering
    • /
    • v.8 no.4
    • /
    • pp.50-57
    • /
    • 2003
  • Cross-flow fans are widely used in various applications, due to their large capacity of mass flow and size compactness. The flow field of the cross-flow fan is, however, complex and has many design parameters. Thus, the general design guide has not been sufficiently established yet and the design strategies of cross-flow fans have been mostly based on experiments. In the present study, the performance and their two-dimensional flow characteristics are numerically analyzed by using the STAR-CD(commercial computational fluid dynamics code). The simulation is done by varying the several design parameters such as the impeller blade shapes and the gap between the stabilizer and impeller. The computational results are compared with the experimental data at the fan outlet region. Finally, some helpful guides for the optimum design of cross-flow fans are proposed.

Optimum Design of a Cross Flow Fan

  • Kim Dong-Hoon;Park Hyung-Koo
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.260-262
    • /
    • 2003
  • Cross-flow fans are widely used in various applications, due to their large capacity of mass flow and size compactness. The flow field of the cross-flow fan is, however, complex and has many design parameters. Thus, the general design guide has not been sufficiently established yet and the design strategies of cross-flow fans have been based on experiments. In the present study, the performance and their two-dimensional flow characteristics are numerically analyzed by using the STAR-CD(commercial computational fluid dynamics code). The simulation is done by varying the several design parameters such as the impeller blade shapes and the gap between the stabilizer and impeller. The computational results are compared with the experimental data at the fan outlet region. Finally some helpful guides for the optimum design of cross-flow fans are proposed.

  • PDF

Experimental study on the design parameter effect on the noise in the cross flow fan (실험에 의한 CROSS FLOW FAN 소음 분석)

  • 안철오;류호선
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.615-620
    • /
    • 1997
  • The flow rate and the noise level of 18 cross flow fans were measured to analyze the effect of design variables on these and to finally find the optimal design value. These data were analyzed by the Taguchi method and the neural network. The optimal values obtained by the neural network showed good agreements with that by the Taguchi method. The effects of eight design variables on the fan performance and the noise were evaluated and discussed.

  • PDF

Design Program of Low Noise Centrifugal Fans (저소음 원심형 홴의 설계 프로그램)

  • 박준철;손정민;김기황;이승배
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11a
    • /
    • pp.529-535
    • /
    • 2001
  • A centrifugal fan design code was developed and packaged together with iDesignFan/sup TM/ as new models. This code generate centrifugal forward curved and backward curved bladed impeller optimally. It also predicts the aerodynamic performance and the overall sound pressure level of the rotating fan by assuming steady blade loading. The overall sound pressure level is used as an input parameter from the third loop of the designing process to acquire the most silent fan for the given aerodynamic performance parameters. With this kind of inverse design concept used in the code, the period of designing a fan is significantly shortened. A centrifugal fan design code, developed in this study and included in iDesignFan/sup TM/, predicts the aerodynamic performance such as design flow rate and static pressure. The aerodynamic performance in the design and off-design conditions is calculated by using the mean line analysis. For the steady loading calculation, the lift force distribution in a blade is used.

  • PDF

Application of Gurney Flaps on a Centrifugal Fan Impeller

  • Dundi, Thomas Manoj Kumar;Sitaram, Nekkanti;Suresh, Munivenkatareddy
    • International Journal of Fluid Machinery and Systems
    • /
    • v.5 no.2
    • /
    • pp.65-71
    • /
    • 2012
  • The objective of the present investigation is to explore the possibility of improving the performance of a centrifugal fan at low Reynolds numbers using a simple passive means, namely Gurney flap (GF). GFs of 1/$8^{th}$ inch brass angle (3.175 mm) corresponding to 15.9% of blade exit height or 5.1% of blade spacing at the impeller tip are attached to the impeller blade tip on the pressure surface. Performance tests are carried out on the centrifugal fan with vaneless diffuser at five Reynolds numbers (viz., 0.30, 0.41, 0.55, 0.69, $0.82{\times}10^5$, i.e., at five speeds respectively at 1,100, 1,500, 2,000, 2,500 and 3,000 rpm) without and with GF. Static pressures on the vaneless diffuser hub and shroud are also measured for each speed at four flow coefficients [${\phi}$=0.23 (below design flow coefficient), ${\phi}$=0.34 (design flow coefficient), ${\phi}$=0.45 (above design flow coefficient) and ${\phi}$=0.60 (above design flow coefficient)] with and without GF. From the performance curves it is found that the performance of the fan improves considerably with GFs at lower Reynolds numbers and improves marginally at higher Reynolds number. Similar improvements are observed for the static pressures on the diffuser hub and shroud. The effect of Reynolds number on the performance and static pressures is considerable. However the effect is reduced with GFs.

Experimental Study on the Aerodynamic Performance Characteristics of a Small-Size Axial Fan with the Different Depths of Bellmouth (벨마우스 깊이가 다른 소형축류홴의 공력특성에 대한 실험적 연구)

  • Kim, Jang-Kweon;Oh, Seok-Hyung
    • Journal of Power System Engineering
    • /
    • v.17 no.6
    • /
    • pp.73-78
    • /
    • 2013
  • A Small-size axial fan(SSAF) has widely been utilized to circulate a cooling air in a refrigerator, etc. Generally, the aerodynamic performance of SSAF is strongly dependent upon the depth between SSAF and bellmouth, and it includes axial, partially stalled, mostly stalled and radial flow regions according to the flow coefficient. In this study, four kinds of bellmouth depths were considered to analyze the aerodynamic performance of SSAF. As a bellmouth depth increases, a maximum flowrate decreases, but a maximum static pressure increases. Also, stall region includes an inflection point in all aerodynamic performance curves. Finally, a static pressure efficiency shows the maximum value of 37%.

Performance Improvement of Sirocco Fan using Design of Experiments (실험계획법을 이용한 시로코팬의 성능향상)

  • Choi, Young-Seok;Jung, Uk-Hee;Lee, Kyoung-Yong
    • 유체기계공업학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.283-286
    • /
    • 2006
  • This paper presents a numerical study on the overall performance and local flow characteristics of the sirocco fan. The effects of impeller and volute shape distribution on the performance of the sirocco fan were numerically studied using a commercial CFD code and a DOE (design of experiments) software. At present, our attention was focused on the relation of the results of DOE and the performance of the sirocco fan. As a main result of the optimization, the performance of the sirocco fan was successfully improved. Also, detailed effects of geometric parameter of impeller and volute in the sirocco fan were discussed.

  • PDF

Anallysis of the flow and noise characteristics of small turbo fan in a ultra slim note PC (초박형 노트북 냉각 터보팬의 유동 및 소음 분석)

  • Jeon, W.H.;Lim, T.G.;Minorkkawa, Gaku;Miyahara, Masaharu
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2013.10a
    • /
    • pp.775-780
    • /
    • 2013
  • In recent years, a notebook like an ultrabook gets thinner. Its thickness causes problems in cooling fan performance, system installation condition, and so on. In this study, we installed a small turbofan in notebook system with very narrow gap in order to generate similar condition to a real product. Experiments were performed to measure the fan's performance and the flow and noise characteristics, its results were compared with computational ones. Prediction of P-Q curve using CFD showed under about 5% error in high flow rate and its trend was agreed with experimental one over the flow field. Experimental data to measure the noise at a distance of 100 mm from a rotation axis direction of an impeller corresponded well with computational ones of broadband and BPF noise. The noise experiments to measure at a distance of 100 mm from a rotation axis direction of an impeller corresponded well with computational ones of broadband and BPF noise. Especially, tip part of impeller blade and part of exit and bottom near in an analysis by a commercial program(FlowNoise).

  • PDF

A Study on the Reduction of Discrete Frequency Tones of a Cross-Flow Fan of Air-Conditioners -Studies on the Random Distribution of Fan Blades and the Skewed Stabilizers- (에어컨 용 횡단류 홴의 특정 주파수 소음 성분의 저감 대책에 관한 연구 -날개의 랜덤 배열과 경사진 스태빌라이저에 대한 연구-)

  • 구형모
    • Journal of KSNVE
    • /
    • v.8 no.5
    • /
    • pp.870-878
    • /
    • 1998
  • The cross-flow fan which constitutes a fan-duct system with a stabilizer and a scroll casing is widely used in many air-ventilating and air-conditioning devices. Its ooperating points of high efficiency and loading conditions frequently induce a annoying sharp tonal component of discrete frequency on the noise spectrum, which is open called as a BPF(Blade-Passing-Frequency) noise and degrades the sound quality of the devices. this BPF tone has been one of the defects of the cross-flow fan. This study proposes two methods in order to reduce this tonal noise component, which are the random distributions of the fan blades and the skewed shapes of the stabilizer. The proposed methods are verified by a simple analytical model and are applied in manufacturing the cross-flow fan and the stabilizer samples. Some experiments are carried out to verify the reduction capability of BPF tones of above two schemes and the experimental results are analyzed. The comparison between two method is also carried out.

  • PDF

Experimental Study on the Thermal Performance of Piezoelectric Fan in an Enclosure (밀폐공간 내에서 압전세라믹 냉각홴의 열성능에 대한 실험적 연구)

  • Park, Sang-Hee;Choi, Moon-Chul
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.12 s.255
    • /
    • pp.1173-1180
    • /
    • 2006
  • This study deals with fluid flow and heat transfer around a module cooled by forced air flow generated by a piezoelectric(PZT) fan in an enclosure. The fluid flows were generated by a flexible PZT fan which deflects inside a fluid transport system of comparatively simple structure mounted on a PCB in an enclosure($270\times260\times90mm^3$). Input voltages of 30V and 40V, and a resonance frequency of 28Hz were used to vibrate the cooling fan. Input power to the module was 4W. The height in an enclosure was changed 23$\sim$43mm. The fluid flow around the module was visualized by using PIV system. The temperature distributions around a heated module were visualized by using liquid crystal film. As the height in an enclosure and the input voltage of PZT fan increased, the cooling effect of module using a PZT fan increased. We found that the flow type was T- or Y-shape and the cooling effect was increased by the wake generated by a PZT fan.