• 제목/요약/키워드: Fan Flow Rate

검색결과 310건 처리시간 0.025초

유량에 따른 축류홴의 익단누설와류 특성 (Flow Characteristics of a Tip Leakage Vortex at Different Flow Rates in an Axial Flow Fan)

  • 장춘만;김광용
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1383-1388
    • /
    • 2004
  • The flow characteristics in the blade passage of a low speed axial flow fan have been investigated by experimental analysis using a rotating hot-wire sensor for design and off-design operating conditions. The results show that the tip leakage vortex is moved upstream when flow rate is decreased, thus disturbing the formation of wake flow near the rotor tip. The tip leakage vortex interfaces with blade pressure surface, and results in high velocity fluctuation near the pressure surface. From the relative velocity distributions near the rotor tip, large axial velocity decay is observed at near stall condition, which results in large blockage compared to that at the design condition. Througout the flow measurements using a quasi-orthogonal measuring points to the tip leakage vortex, it is noted that the radial position of the tip leakage vortex is distributed between 94 and 96 percent span for all flow conditions. High spectrum density due to the large fluctuation of the tip leakage vortex is observed near the blade suction surface below the frequency of 1000 Hz at near stall condition.

  • PDF

Analysis of interaction between river and groundwaterin Kurobe river fan by a grid-based hydrological model

  • Takeuchi, Masanobu;Murata, Fumito;Katayama, Takeshi;Nakamura, Shigeru;Nakashima, Noriyuki;Yamaguchi, Haruka;Baba, Aki
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2012년도 학술발표회
    • /
    • pp.26-26
    • /
    • 2012
  • The Kurobe river, which runs through eastern Toyama Prefecture is one of the most famous rivers for wild water because of its steep slope in the range from 1/5 to 1/120. This river forms an alluvial fan in the range up to 13 kilometers from the sea. In this region, significant seepage flow occurs and thus the stream sometimes been intermitted. Moreover, the amount of seepage flow seems to vary with the groundwater level of the region. To keep the river environment healthy for flora and fauna, especially to conserve good condition for spawning of fishes, an appropriate environmental flow should be maintained in the river. To achieve this target, controlling of the upstream reservoir has to be studied in depth. One of the major problems to decide the amount of water to be released from the reservoir to maintain the environmental flow is to estimate the amount of water leaked into the groundwater from the river. This phenomenon is affected by the river flow rate as well as the groundwater level in the alluvial fan and the conditions vary in space and time. Thus, a grid-based hydrological cycle analysis model NK-GHM has been applied to clarify the hydrological cycle componentsin this area including seepage/discharge from/to the river. The model was tested by comparing with river flow rate, groundwater levels and other observations and found that the model described those observations well. Consequently, the seepage from the Kurobe river was found significant but it was also found that the groundwater in this region has been preserved by the recharge from the irrigation water supply into paddy fields in the alluvial fan.

  • PDF

덕트누기시험기용 풍량측정 오리피스의 최적위치 선정에 관한 연구 (A Study on the Optimal Orifice Location for Air flow Measurement in an Air Duct Leakage Tester)

  • 이승철
    • 설비공학논문집
    • /
    • 제18권2호
    • /
    • pp.186-191
    • /
    • 2006
  • In this study, five experiments were carried out, with an orifice located downstream of a fan in case I where upstream duct length is 6 D, and that in the downstream is 4 D and different downstream distance to the fan in the rest, so as to determine the optimal location of the orifice and reduce the duct length of airflow measurement device. The resulting flow rate-pressure drop correlations were found to satisfy the limitation of SMACNA standard, which specified an error of $\pm7.5\%$ based on the real flow rate. Also, the best one of five. cases was achieved with the orifice located midway of the orifice duct four times its diameter long.

덕트누기시험기용 풍량측정 오리피스의 최적위치 선정에 관한 연구 (Optimal Location of Orifice in Duct Leakage Tester for Air Flow Measurement)

  • 이승철;박만흥;김광추
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.2151-2156
    • /
    • 2004
  • In this study, five experiments were carried out, with an orifice located downstream of a fan in case I and upstream distance to the fan in the rest cases(case $II{\sim}$), so as to determine the optimal location of the orifice and reduce the size of airflow measurement device. The resulting flow rate-pressure drop correlations were found to satisfy the limitation of SMACNA standard, which specified an error of ${\pm}7.5%$ based on the real flow rate. The best outcome was achieved with the orifice located midway of the orifice duct 4 times its diameter long.

  • PDF

저소음 원심형 홴의 설계 프로그램 (Design Program of Low Noise Centrifugal Fans)

  • 박준철;손정민;김기황;이승배
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 추계학술대회논문집 I
    • /
    • pp.529-535
    • /
    • 2001
  • A centrifugal fan design code was developed and packaged together with iDesignFan/sup TM/ as new models. This code generate centrifugal forward curved and backward curved bladed impeller optimally. It also predicts the aerodynamic performance and the overall sound pressure level of the rotating fan by assuming steady blade loading. The overall sound pressure level is used as an input parameter from the third loop of the designing process to acquire the most silent fan for the given aerodynamic performance parameters. With this kind of inverse design concept used in the code, the period of designing a fan is significantly shortened. A centrifugal fan design code, developed in this study and included in iDesignFan/sup TM/, predicts the aerodynamic performance such as design flow rate and static pressure. The aerodynamic performance in the design and off-design conditions is calculated by using the mean line analysis. For the steady loading calculation, the lift force distribution in a blade is used.

  • PDF

A Suggested Mechanism of Significant Stall Suppression Effects by Air Separator Devices in Axial Flow Fans

  • Yamaguchi, Nobuyuki
    • International Journal of Fluid Machinery and Systems
    • /
    • 제4권1호
    • /
    • pp.57-66
    • /
    • 2011
  • Radial-vaned air separators show a strong stall suppression effect in an axial flow fans. From a survey of existing literature on the effects and the author's data, a possible mechanism for the significant effects has been proposed here. The stall suppression is suggested to have been achieved by a combination of the following several effects; (1) suction of blade and casing boundary layers and elimination of embryos of stall, (2) separation and straightening of reversed swirling flow from the main flow, (3) induction of the fan main flow toward the casing wall and enhancement of the outward inclination of meridional streamlines across the rotor blade row, thus keeping the Euler head increase in the decrease in fan flow rate, and (4) reinforcement of axi-symmetric structure of the main flow. These phenomena have been induced and enhanced by a stable vortex-ring encasing the blade tips and the air separator. These integrated effects appear to have caused the great stall suppression effect that would have been impossible by other types of stall prevention devices. Thus the author would like to name the device "tip-vortex-ring assisted stall suppression device".

외측 회전형 심구형 유도전동기의 특성 (The characteristics of deep slot outside rotor type IM)

  • 안병원;박영산;노영오;배철오
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2000년도 추계종합학술대회
    • /
    • pp.547-552
    • /
    • 2000
  • 팬의 동력원으로 사용되고 있는 일반전동기는 실치 시 팬의 전동기 부분이 돌출되어 송풍량을 제한 한다든지 곡관을 설치해야하는 문제점이 있다. 따라서 이러한 단점을 보완하기 위한 새로운 형식의 축류팬용 유도전동기를 개발하여 특성을 파악하였다. 이 유도전동기는 기존전동기와는 달리 내측이 전기자인 고정자이고 외측이 회전자로 구성되어 있다.

  • PDF

등압법과 T-method를 이용한 공조시스템 배관 설계에 관한 연구 (A Study on the Duct Design of HVAC System Using the Equal Friction Method and the T-method)

  • 박준석;최길환;조대승
    • 대한조선학회논문집
    • /
    • 제46권4호
    • /
    • pp.435-443
    • /
    • 2009
  • Optimal duct design of a HVAC system requires analysis technology to accurately evaluate its pressure losses, flow rate and velocity for making a compromised design among fan capacity and duct size affecting initial manufacturing and operation costs, and noise induced by the HVAC system. In this paper, we carry out initial duct design using the equal friction method. Using the result, the T-method is applied for accurate analysis of flow rate. Then, the duct size is modified using the difference between the required and the calculated flow rate, which can guarantee required flow rate, reduce the pressure unbalance among duct paths and lead to select optimal fan performance. To verify the validity and effectiveness of the proposed design method, an example for HVAC system design including noise analysis is demonstrated.

제트 팬 위치에 따른 곡선형 장대터널의 환기해석 (Ventilation Analysis According to Jet Fan Location in Curved Long Road Tunnel)

  • 변주석;강신형;김지성;이진호
    • 설비공학논문집
    • /
    • 제19권9호
    • /
    • pp.669-678
    • /
    • 2007
  • In this study, the ventilation characteristics is investigated numerically of the longitudinal ventilation method in the curved long road tunnel. Numerical work has been conducted for the jet fan location by utilizing the commercial finite-volume code, FLUENT. Configuration of the tunnel is three-lane, 1600 m long, $120m^2$ in area, 3000 m curvature radius. The velocity profile, distribution of mono-dioxide carbon and flow rate of air are examined in the tunnel. Through the analysis, it is found that the difference of ventilation flow rate Is a little by the jet fan location, but tunnel outlet setup (CASEIII) of jet fans is the most efficient concerned with CO concentration.

타원관 열교환기를 적용한 팬코일 유닛의 운전 조건이 무차원 성능계수에 미치는 영향 (Effect of Operating Conditions of a Fan-Coil Unit with an Oval Tube Type Heat Exchanger on Non-Dimensional Performance Coefficient)

  • 윤재동;이영훈;성재용
    • 한국지열·수열에너지학회논문집
    • /
    • 제15권1호
    • /
    • pp.1-8
    • /
    • 2019
  • In this study, the effect of operating conditions of fan-coil unit with an oval tube type heat exchanger on its non-dimensional performance coefficient has been investigated. Pressure drops and heat transfer rates were measured under heating condition for various water flow rates, inlet temperatures and wind speeds. As a non-dimensional performance coefficient, Colburn j-factor was evaluated. The results show that the most sensitive parameter on heat flux is the inlet temperature, which affects the heat flux 4.7 and 7.2 times more than the wind speed and water flow rate, respectively. On the other hand, the Colburn j-factor as a non-dimensionalized index decreases with the wind speed, and has an maximum when the wind speed is about 1 m/s. the Colburn j-factor increases slowly with the water flow rate and inlet temperature but at a certain range of inlet temperature, the opposite phenomenon is found.