• 제목/요약/키워드: Fan/Blowers

검색결과 14건 처리시간 0.02초

터보 블로워 표준화 제품 개발 사례 (Development of Standard Series for Turbo Blowers)

  • 송귀은;김광호;강신형;김회룡
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2000년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.99-103
    • /
    • 2000
  • This paper describes the development of standard series for turbo blowers. In mass production system, it is very required to standardize blowers to improve the productivity of ordering, estimating, manufacturing. To standardize blowers, we performed researches on the effects of $b_1$(impeller inlet width), $b_2$(impeller outlet width), ${\beta}_1$(blade inlet angle), ${\beta}_2$(blade outlet angle), Z(number of blades) of impellers and geometry of casing experimentally. Through this study, we chose the several best model of turbo blowers with high efficiency and low noise, which represent each specific speed series 63, 80, 100, 125, 160, 200, 250, 315. After the development of such standardized blowers, the test results are used to prepare the fan geometry and performance database for a selection software.

  • PDF

엇회전식 축류홴의 공력 특성에 관한 실험적 연구 (Experimental Study on the Aerodynamic Characteristics of a Counter-Rotating Axial Fan)

  • 최진용;조이상;조진수;원유필
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집B
    • /
    • pp.441-446
    • /
    • 2000
  • The experiments of the Aerodynamic characteristics of a counter-rotating axial fan were carried out. The performance tests of a single and a counter-rotating axial fan were carried out based on the Korean Standard Testing Methods for Turbo-fans and Blowers(KS B 6311). The performances of single and counter-rotating axial fans were obtained and compared with each other. The flow fields of a counter-rotating axial fan at the peak efficiency point were measured using a five-hole probe. As a result, compared with the performance of a single-rotating axial fan, that of a counter-rotating axial fan was superior. And it is confirmed that most of the swirl flow generated by the front rotor was eliminated by the rear rotor.

  • PDF

엇회전식 축류 펜의 공력 특성에 관한 실험적 연구 (Experimental Study on the Aerodynamic Characteristics of a Counter-Rotating Axial Flow Fan)

  • 최진용;조이상;조진수;원유필
    • 대한기계학회논문집B
    • /
    • 제26권2호
    • /
    • pp.201-210
    • /
    • 2002
  • Experiments were done for performance and flow characteristics of a counter-rotating axial flow fan. Performance curves of a counter-rotating axial flow fan were obtained and compared by varying the blade pitch angles. The fan characteristic curves were obtained following the Korean Standard Testing Methods for Turbo Fans and Blowers (KS B 6311). The fan flow characteristics were measured using a five-hole probe and a slanted hot-wire. The velocity profiles between the hub and tip of the fans were measured and analyzed at the peak efficiency point. The peak efficiency of the counter-rotating axial flow fan was improved about 15% respectively, compared with the single rotating axial fan. The single rotating axial flow fan showed relatively law efficiency due to the swirl velocities behind rotor exit which produced pressure losses. The counter-rotating axial flow fan showed that the swirl velocity generated by the front rotor was eliminated by the rear rotor and the associated dynamic pressure is recovered in the from of the static pressure rise.

2단 축류팬과 엇회전식 축류팬의 공력 특성에 관한 실험적 연구 (Experimental Study on the Aerodynamic Characteristics of a Two Stage and a Counter-Rotating Axial Flow Fan)

  • 조이상;조진수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.541-547
    • /
    • 2000
  • Experiments were done for the comparison of performance and flow characteristics between a two stage axial flow fan and a counter-rotating axial flow fm. The fan performance curves were obtained by the Korean Standard Testing Methods for Turbo Fans and Blowers (KS B 6311). The fan flow characteristics were measured using a five-hole probe by the non-nulling method. Each stage of the two stage axial flow fan used for the present study has an eight bladed rotor and thirteen stator blades. The front and the rear rotor of the counter-rotating axial flow fan have eight blades each and are driven by coaxial counter rotating shafts through a gear box located between the rear rotor and the electric motor. Both of the two axial fan configurations use identical rotor blades and the same operating conditions for the one-to-one comparison of the two. Performance characteristics of the two configurations were obtained and compared by varying the blade setting angles and axial gaps between the blade rows. The passage flow fields between the hub and tip of the fans were measured and analyzed for the particular operating conditions of peak efficiency, minimum and maximum pressure coefficients.

  • PDF

2단 축류홴과 엇회전식 축류홴의 공력특성에 관한 실험적 연구 (Experimental Study on the Aerodynamic Characteristics of a Two-Stage and a Counter-Rotating Axial Flow Fan)

  • 조진수;조이상
    • 대한기계학회논문집B
    • /
    • 제25권10호
    • /
    • pp.1281-1292
    • /
    • 2001
  • Experiments were done for the comparison of performance and flow characteristics between a two -stage axial flow fan and a counter-rotating axial flow fan. Each stage of the two -stage axial flow fan used fur the present study has an eight bladed rotor and thirteen slater blades. The front and the rear rotor of the counter - rotating axial flow fan have eight blades each and are driven by coaxial counter ro latins shafts through a gearbox located between the rear rotor and the electric motor. Both of the two axial fan configurations have identical rotor blades and the same operating condition fur the one -to-one comparison of the two. Performance curves of the two configurations were obtained and compared by varying the blade pitch angles and axial gaps between the blade rows. The fan characteristic curves were obtained following the Korean Standard Testing Methods for Turbo Fans and Blowers (KS B 6311). The fa n flow characteristics were measured using a five-hole probe by a non-nulling method. The velocity profiles between the hub and tip of the fans were measured and analyzed at the particular operating condition s of peak efficiency, minimum and maximum pressure coefficients. The peak efficiency of the counter-rotating axial fan was improved about 2% respectively, compared with the two stage axial fan. At the minimum pressure coefficient point of the two stage axial fan, the fan inlet flow patterns show that axial velocity highly decreased in the vicinity of the blade tip region. Also, the reverse flow took place at the blade tip.

고성능 2단 축류송풍기의 공력설계를 위한 수치해석 및 실험에 관한 연구 (A Numerical Method & Experiments for the Aerodynamic Design of High Performance 2-Stage Axial Flow Fans)

  • 조진수;한철희;조이상
    • 대한기계학회논문집B
    • /
    • 제23권8호
    • /
    • pp.1048-1062
    • /
    • 1999
  • A numerical method and experiments for the aerodynamic design of high performance two-stage axial flow fans was carried out. A vortex ring element method used for the aerodynamic analysis of the propellers was extended to the fan-duct system. Fan Performance and velocity profiles at the fan inlet and outlet are compared with experimental data for the validations of numerical method. Performance test was done based on KS B 6311(testing methods for turbo-fans and blowers). The velocity profile was obtained using a 5-hole pitot tube by the non-nulling method. The two stage axial flow fan configurations for the optimal operation conditions were set by using the experimental results for the single rotating axial flow fan and the single stage axial flow fan. The single rotating axial flow fan showed relatively low efficiency due to the swirl velocities behind rotor exit which produced pressure losses. In contrast, the single stage and the two-stage axial flow fans showed performance improvements due to the swirl velocity reduction by the stator. The peak efficiency of the two stage axial flow fan was improved by 21% and 6%, compared to the single rotating axial flow fan and the single stage axial flow fan, respectively.

원심 전향익 송풍기 제품규격 KS B 6326의 개정 해설 (Revision of Forward Curved Bladed fans: KS B 6326)

  • 이승배;김회룡;김광용;정근화
    • 한국유체기계학회 논문집
    • /
    • 제4권1호
    • /
    • pp.46-51
    • /
    • 2001
  • The revision is proposed for forward curved bladed fans in order to make the KS B 6326 established in 1987 in agreements with newly revised KS standards. This proposal includes modification of Aplication range, numbering system, classification based on performance, and allowing dimensions for specified sizes.

  • PDF

원심 전향익 송풍기 제품규격 KS B 6326의 개정 (Revision of Forward Curved Bladed Fans: KS B 6326)

  • 이승배;김회룡;김광용;정근화
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2000년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.104-109
    • /
    • 2000
  • The revision was proposed for forward curved bladed fans in order to make the KS B 6326 established in In in agreements with newly revised KS standards. This proposal includes modification of Application range, numbering system classification based on performance, and allowing dimensions for specified sizes.

  • PDF

타워형 에어컨 송풍기 소음의 능동제어 (Active Control of Noise from Fan Blowers in Tower-type Air Conditioners)

  • 류경완;홍진숙;정의봉
    • 한국소음진동공학회논문집
    • /
    • 제27권1호
    • /
    • pp.87-93
    • /
    • 2017
  • This paper investigates active noise control of tower-type air conditioners using the filtered-x least mean square (FXLMS) algorithm to reduce fan blower noise transmission. Firstly, the main components required for the active control system including the error sensor, the control speaker and the reference sensors are selected. Since the noise could significantly reduce if the reference signal includes every frequency response information, a various reference signals from accelerometers and a microphone are used. Secondly, the controller based on the FXLMS algorithm with a single-channel reference signal is implemented. Then, the control performance is examined experimentally for the different reference signals. It is found that the accelerometer signal well possesses the motor vibration related noise and a microphone signal could includes global noise. When using the reference signal with a microphone located near the motor and the fan blower, the active control system reduces the noise globally, except for several peaks.