• 제목/요약/키워드: False-negative results

검색결과 302건 처리시간 0.029초

The Relationship between Chinese Parents' Reaction to Children's Negative Emotions and Children's Understanding of Emotions

  • Jin, Rihua;Lee, Young
    • Child Studies in Asia-Pacific Contexts
    • /
    • 제4권2호
    • /
    • pp.109-126
    • /
    • 2014
  • The purpose of this study was to investigate Chinese parents' reaction to their children's negative emotions and how these reactions relate to their children's understanding of emotions. Forty-two Chinese children (aged 4) and their parents participated in this study. Coping with Children's Negative Emotion Scale was given to parents to assess their reaction to their children's negative emotions. Children's emotional understanding was assessed using the modified emotional false-belief task and mixed emotion task. The results showed that Chinese parents gave supportive reactions more than non-supportive reactions to their children, and no difference in sex was found. The percentages of correct answers to false-belief task and mixed emotion task were low with no gender difference in both tasks. When age and sex of children were controlled, only fathers' supportive reactions to children's negative emotions significantly explained the variances in the level of children's understanding of emotions in both tasks. That is, children whose fathers showed greater supportive reactions to their negative emotions performed better at both tasks. It was concluded that fathers' supportive reactions to their children's negative emotions are very influential for emotional understanding among 4-year-old children in China.

경부 종류의 세침 흡인 세포학적 검사에 대한 임상적 고찰 (A Clinical Observation of Fine Needle Aspiration Cytology in the Neck Mass)

  • 임종학;김재준;이동화;허경발
    • 대한두경부종양학회지
    • /
    • 제8권1호
    • /
    • pp.31-36
    • /
    • 1992
  • Neck mass is common neoplasms, but it poses a diagnostic dilemma for the physician. The differential diagnosis include neoplastic, inflammatory and developmental causes. The FNAC is one of the most valuable tests in the initial assessment and differential diagnosis of the neck mass. FNAC was performed with 267 cases of the neck mass, during the period from April, 1988 to October, 1990 at the department of General Surgery, Soon Chun Hyang. University Hospital. Thyroid lesions were excluded from this analysis. Final diagnosis was based on resection histology in 58 cases, and surgical specimens were compared with FNAC. The following results were obtoired ; 1) Of 267 cases, there we re 9 cases(3.4%) of congenital lesion, 74 cases(27.7%) of inflammatory lesion, 40 cases(15.0%) of benign tumor, 12 cases(4.5%) of primary malignant tumor, 37 cases(13.8%) of metastatic tumor, 75cases(28.1%) of reactive hyperplasia, 20 cases(7.5%) of unsatisfactory. In the pathologic classification, inflammatory lesion was the most common. 2) In the 58 cases of excisional biopsy, sensitivity 93.8%, specificity 95.2%, false positive 11.8%, false negative 2.4%, positive predictive value 88.2%, negative predictive value 97.6%, accuracy 94.8%. 3) The most common disease was the tuberculous lymphadenitis (53 cases, 19.8%). sensitivity 57.9%, specificity 100.0%, false positive 0.0%, false negative 17.0%, positive predictive value 100.0%, negative predictive value 83.0%, accuracy 86.2%.

  • PDF

갑상선 결절의 세침흡인 세포검사: 진단성적의 검토 및 세포학적 진단의 평가 (Fine Needle Aspiration Cytology of Thyroid Nodules: Assessment of diagnostic accuracy and evaluation of each cytologic diagnosis)

  • 박인애;함의근
    • 대한세포병리학회지
    • /
    • 제10권1호
    • /
    • pp.43-53
    • /
    • 1999
  • We retrospectively reviewed the results of 1,850 fine needle aspiration cytology(FNAC) of thyroid nodules performed from 1990 to 1991 in the Department of Pathology, Seoul National University Hospital. Among 1,528 cases and 322 cases aspirated by clinicians and a pathologist, 465 cases(30.4%) and 13 cases(4.0%) of the aspirates were inadequate, respectively. In 227 cases, correlation of the FNAC diagnosis and histologic diagnosis was done. Excluding the inadequate cases, the sensitivity nor the detection of neoplasm(malignancy together with follicular adenoma) was 86.4% and the specificity was 70.7%. The overall diagnostic accuracy was 79.0%. There were 16 false-positive cases(7.0%), and 19 false-negative cases(8.4%). The predictive value of each cytologic diagnosis was 92% in papillary carcinoma, and 100%, in Hashimoto's thyroiditis. The expectancy of malignancy was 52.8% in "suspicious malignancy" and 26.7% in "atypical lesion".

  • PDF

간 혈관종의 Tc-99m 표지 적혈구 혈액풀 스캔 (Evaluation of Hepatic Hemangioma by Tc-99m Red Blood Cell Hepatic Blood Pool Scan)

  • 손명희
    • 대한핵의학회지
    • /
    • 제39권3호
    • /
    • pp.151-162
    • /
    • 2005
  • Hemangioma is the most common benign tumor of the liver, with a prevalence estimated as high as 7%. Tc-99m red blood cell (RBC) hepatic blood pool scan with single photon omission computed tomography (SPECT) imaging is extremely useful for the confirmation or exclusion of hepatic hemangiomas. The classic finding of absent or decreased perfusion and increased blood pooling ("perfusion/blood pool mismatch") is the key diagnostic element in the diagnosis of hemangiomas. The combination of early arterial flow and delayed blood pooling ("perfusion/blood pool match") is shown uncommonly. In giant hemangioma, filling with radioactivity appears first in the periphery, with progressive central fill-in on sequential RBC blood pool scan. However, the reverse filling pattern, which begins first in the center with progressive peripheral filling, is also rarely seen. Studies with false-positive blood pooling have been reported infrequently in nonhemangiomas, including hemangiosarcoma, hepatocellular carcinoma, hepatic adenoma, and metastatic carcinomas (adenocarcinoma of the colon, small cell carcinoma of the lung, neruroendocrine carcinoma). False-negative results have been also reported rarely except for small hemagniomas that are below the limits of spatial resolution of gamma camera.

공격 횟수와 공격 유형을 고려하여 탐지 성능을 개선한 차량 내 네트워크의 침입 탐지 시스템 (Intrusion Detection System for In-Vehicle Network to Improve Detection Performance Considering Attack Counts and Attack Types)

  • 임형철;이동현;이성수
    • 전기전자학회논문지
    • /
    • 제26권4호
    • /
    • pp.622-627
    • /
    • 2022
  • 본 논문에서는 공격 횟수와 공격 유형을 모두 고려하여 차량 내 네트워크에서 해킹을 탐지하는 침입 탐지 시스템의 성능을 개선하는 기법을 제안한다. 침입 탐지 시스템에서 침입을 정상으로 잘못 인식하는 FNR(False Negative Rate)과 정상을 침입으로 잘못 인식하는 FPR(False Positive Rate)은 모두 차량의 안전에 큰 영향을 미친다. 본 논문에서는 일정 홧수 이상 공격으로 탐지된 데이터 프레임을 자동적으로 공격으로 처리하며, 자동 공격으로 판단하는 방법도 공격 유형에 따라 다르게 적용함으로서 FNR과 FPR을 모두 개선하는 침입 탐지 기법을 제안하였다. 시뮬레이션 결과 제안하는 기법은 DoS(Denial of Service) 공격과 Spoofing 공격에서 FNR과 FPR을 효과적으로 개선할 수 있었다.

A NEW SYSTEM OF VISUAL PRESENTATION OF ANALYSIS OF TEST PERFORMANCE: THE 'DOUBLE-RING' DIAGRAM

  • Stefadouros Miltiadis A.
    • 대한예방의학회:학술대회논문집
    • /
    • 대한예방의학회 1994년도 교수 연수회(역학)
    • /
    • pp.142-149
    • /
    • 1994
  • Substitution of graphic representation for extensive lists of numerical statistical data is highly desirable by both editors and readers of medical journals, faced with an exploding abundance of contemporary medical literature. A novel graphic tool. the 'double-ring diagram', is described herein which permits visual representation of information regarding certain statistical variables used to describe the performance of a test or physical sign in the diagnosis of a disease. The diagram is relatively easy to construct on the basis of a number of primary data such as the prevalence and the true positive, true negative. false positive and false negative test results. These values are reflected in the diagram along with the values of other statistical variables derived from them. such as the sensitivity. specificity, predictive values for positive and negative test result. and accuracy. This diagram may be useful in visualizing a test's performance and facilitating visual comparison of performance of two or more tests.

  • PDF

Comparative Study of Electromyography and Hand Elevation Test in Carpal Tunnel Syndrome

  • Yun, Tae Kyoung;Kim, Deok-Yeol;Ahn, Duck Sun
    • Archives of Reconstructive Microsurgery
    • /
    • 제24권1호
    • /
    • pp.13-15
    • /
    • 2015
  • Purpose: Since the hand elevation test was first introduced by Ahn in 2001, it has been one of most performing provocative test for diagnosing carpal tunnel syndrome. Although many studies have been published on the hand elevation test, there are no study that can explain why false-negative results of hand elevation test appears in carpal tunnel syndrome patients diagnosed by electromyography (EMG) findings. Therefore we searched out whether hand elevation test is related with EMG severity. Materials and Methods: We made a retrospective study of 654 bilateral carpal tunnel syndrome patients. Among them 134 were studied which had different hand elevation test results on each hands. The paired samples t-test was used to compare the EMG severity of each group. The relationships between hand elevation test and EMG severity were examined using Pearson-product correlations. Comparing whether the frequency of false negative hand elevation were different between both hands, and whether the severity of EMG depends on which side of hand is, was evaluated with Mann-Whitney U-test. Results: Severity of EMG in positive group was moderate to severe on average, whereas mild to moderate on negative group, with significant difference statistically (p<0.001). Correlation between the hand elevation test results and EMG severity also showed significance statistically (p<0.001). Conclusion: Mild severity of EMG was found out to be the factor affecting the false results. However, EMG severity and hand elevation test shows a meaningful correlation, supporting the value of hand elevation test.

Estimation of Leucine Aminopeptidase and 5-Nucleotidase Increases Alpha-Fetoprotein Sensitivity in Human Hepatocellular Carcinoma Cases

  • Abouzied, Mekky Mohammed;Eltahir, Heba M.;Fawzy, Michael Atef;Abdel-Hamid, Nabil Mohie;Gerges, Amany Saber;El-Ibiari, Hesham Mohmoud;Nazmy, Maiiada Hassan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권3호
    • /
    • pp.959-963
    • /
    • 2015
  • Purpose: To find parameters that can increase alpha-fetoprotein (AFP) sensitivity and so help in accurate diagnosis and rapid management of hepatocullular carcinoma (HCC), as AFP has limited utility of distinguishing HCC from benign hepatic disorders for its high false-positive and false negative rates. Materials and Methods: Serum levels of AFP, 5'-nucleotidase enzyme activity (5-NU) and leucine aminopeptidase enzyme (LAP) activity were measured in 40 individuals. Results: LAP and 5'NU were elevated in HCC at p<0.001. Pearson correlation coefficients showed that changes in AFP exhibited positive correlation with both 5'-NU and LAP at (p<0.001). The complementary use of LAP only with AFP resulted in an increase in sensitivity of AFP from 75% to 90% in detecting HCC. The complementary use of both LAP and 5-NU with AFP resulted in an increased sensitivity of AFP in detecting HCC from 75% to 95%. Conclusions: LAP and 5-FU can be determined in HCC patients in combination with AFP to improve its sensitivity and decrease false negative results.

Computer-Aided Detection with Automated Breast Ultrasonography for Suspicious Lesions Detected on Breast MRI

  • Kim, Sanghee;Kang, Bong Joo;Kim, Sung Hun;Lee, Jeongmin;Park, Ga Eun
    • Investigative Magnetic Resonance Imaging
    • /
    • 제23권1호
    • /
    • pp.46-54
    • /
    • 2019
  • Purpose: The aim of this study was to evaluate the diagnostic performance of a computer-aided detection (CAD) system used with automated breast ultrasonography (ABUS) for suspicious lesions detected on breast MRI, and CAD-false lesions. Materials and Methods: We included a total of 40 patients diagnosed with breast cancer who underwent ABUS (ACUSON S2000) to evaluate multiple suspicious lesions found on MRI. We used CAD ($QVCAD^{TM}$) in all the ABUS examinations. We evaluated the diagnostic accuracy of CAD and analyzed the characteristics of CAD-detected lesions and the factors underlying false-positive and false-negative cases. We also analyzed false-positive lesions with CAD on ABUS. Results: Of a total of 122 suspicious lesions detected on MRI in 40 patients, we excluded 51 daughter nodules near the main breast cancer within the same quadrant and included 71 lesions. We also analyzed 23 false-positive lesions using CAD with ABUS. The sensitivity, specificity, positive predictive value, and negative predictive value of CAD (for 94 lesions) with ABUS were 75.5%, 44.4%, 59.7%, and 62.5%, respectively. CAD facilitated the detection of 81.4% (35/43) of the invasive ductal cancer and 84.9% (28/33) of the invasive ductal cancer that showed a mass (excluding non-mass). CAD also revealed 90.3% (28/31) of the invasive ductal cancers measuring larger than 1 cm (excluding non-mass and those less than 1 cm). The mean sizes of the true-positive versus false-negative mass lesions were $2.08{\pm}0.85cm$ versus $1.6{\pm}1.28cm$ (P < 0.05). False-positive lesions included sclerosing adenosis and usual ductal hyperplasia. In a total of 23 false cases of CAD, the most common (18/23) cause was marginal or subareolar shadowing, followed by three simple cysts, a hematoma, and a skin wart. Conclusion: CAD with ABUS showed promising sensitivity for the detection of invasive ductal cancer showing masses larger than 1 cm on MRI.

프레임간의 상대적인 차이를 이용한 비디오의 셔트 검출 기법 (Shot Boundary Detection Using Relative Difference between Two Frames)

  • 정인식;권오진
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2001년도 하계종합학술대회 논문집(4)
    • /
    • pp.101-104
    • /
    • 2001
  • This paper proposes a unique shot boundary detection algorithm for the video indexing and/or browsing. Conventional methods based on the frame differences and the histogram differences are improved. Instead of using absolute frame differences, block by block based relative frame differences are employed. Frame adaptive thresholding values are also employed for the better detection. for the cases that the frame differences are not enough to detect the shot boundary, histogram differences are selectively applied. Experimental results show that the proposed algorithm reduces both the “false positive” errors and the “false negative” errors especially for the videos of dynamic local and/or global motions

  • PDF