• Title/Summary/Keyword: False-negative results

Search Result 303, Processing Time 0.024 seconds

Comparison between Visual Inspection of Cervix and Cytology Based Screening Procedures in Bangladesh

  • Nessa, Ashrafun;Nahar, Khadiza Nurun;Begum, Shirin Akhter;Anwary, Shahin Ara;Hossain, Fawzia;Nahar, Khairun
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.12
    • /
    • pp.7607-7611
    • /
    • 2013
  • Background: Cervical cancer continues to be a major problem in Bangladesh with approximately 18,000 new cases annually of which over 10,000 women die from it. Visual inspection of the cervix after 3-5% acetic acid (VIA) application is a simple and easy to learn method for cervical cancer screening, although cytology-based screening is more often applied in developed countries where it has successfully reduced the prevalence of cervical cancer. Objective: To compare the efficacy of VIA and cytology-based primary methods for cervical cancer screening in Bangladesh. Materials and Methods: This hospital based comparative study was conducted at the VIA centre and Colposcopy Clinic of Bangabandhu Sheikh Mujib Medical University (BSMMU) from October 2008 to October 2010. Results: Among 650 women, 74 (11.4%) were VIA+ve and 8 (1.2%) had abnormalities in their Pap smear reports. During colposcopy, 38 (7.7%) women had different grades of CIN and 4 (0.6%) had cervical cancer. The gold standard histology findings proved 20 women had CIN I, 14 had CIN II/II and 4 had cervical cancer. Among the 38 histology diagnosed abnormalities, VIA test could identify 30 abnormalities including two cervical cancers. However, Pap smear could detect only 8 cases of histological abnormalities (2 low grade and 6 had high grade lesion) and it missed all the cervical cancer cases. The sensitivity and specificity of VIA were 88.9% and 52.1%. The positive predictive value (PPV) and negative predictive value (NPV) were 41.0%, and 92.6% respectively. Moreover, the sensitivity, specificity, PPV and NPV of Pap smear were 33.3%, 95.8%, 75.0% and 79.3%, respectively. Conclusions: VIA test should be used as the primary screening tool even with its low sensitivity and specificity in low resource countries like Bangladesh. False positive results may be greater, but overtreatment can be minimized by colposcopy evaluation of the VIA positive women.

Sentinel Lymph Node Identification Using $^{99m}Tc$-Neomannosyl Human Serum Albumin in Esophageal Cancer; Comparison with $^{99m}Tc$-Phytate (식도암 환자에서 $^{99m}Tc$-Neomannosyl Human Serum Albumin과 $^{99m}Tc$-Phytate를 이용한 감시림프절 탐색의 비교)

  • Kim, Hyun-Koo;Kang, Du-Young;Kim, Seung-Eun;Park, Jong-Jae;Jeong, Jae-Min;Mok, Young-Jae;Choi, Young-Ho
    • Korean Journal of Bronchoesophagology
    • /
    • v.16 no.2
    • /
    • pp.109-114
    • /
    • 2010
  • Background: The aim of this study was to compare a novel mannose receptor-binding agent(Technetium-99m human serum albumin, $^{99m}Tc$-MSA) with $^{99m}Tc$-phytate for sentinel node mapping in patients with esophageal cancer. Material and Method: Twenty patients with clinical stage T1N0m0 or T2N0M0 esophageal cancer that were candidates for esophagectomy were enrolled. Endoscopic injection of $^{99m}Tc$-MSA or $^{99m}Tc$-phytate was administered at the peri-tumor region before surgery in 10 patients. The radioactive lymph nodes were identified with a handheld gamma probe after lymph node dissection. Results: The patient's age and the sex ratio of both groups were similar. The clinical stage, tumor location, and operative technique did not differ. The total number of dissected lymph nodes did not differ ($28.5{\pm}9.12$ in MSA group, $32.2{\pm}11.24$ in phytate group, p=0.430). The sentinel node was identified in all cases in both groups. The number of sentinel nodes per patient was $2.7{\pm}1.57$ in the MSA group, which was significantly greater than the $1.7{\pm}0.88$ in the phytate group (p=0.036). Five out of 20 patients whose sentinel nodes could be identified had metastases; however, neither group had any false-negative results for sentinel node identification. Conclusion: Sentinel nodes were detected more frequently with MSA than with phytate.

  • PDF

Analysis of the reasons why single women in their thirties or forties choose not to marry: - implications for population education - (30-40대 싱글여성이 '결혼을 하지 않는 이유'분석 - 인구교육의 시사점 도출을 위하여 -)

  • Wang, Seok Soon;Jun, Joo Ram;Ryu, Kyung Hee
    • Journal of Korean Home Economics Education Association
    • /
    • v.27 no.2
    • /
    • pp.35-51
    • /
    • 2015
  • The purpose of the present study is to investigate the various reasons that might lead single women to choose not to marry. Semi-structured in-depth interviews were arranged with 18 single women who met the criteria for the present research purpose. We considered only those responses of the interviewees that are directly related to their reasons why they choose not to marry, where the collected data were analyzed in three steps by methods of thematic analysis. As a result of the analysis, the reasons for which they chose not to marry could be grouped into three main clusters of themes which may be labeled as (1) themes centered on 'Myself', (2) themes centered on 'Family' and (3) themes centered on 'Surrounding Environments and Friends'. Among the first category of themes of 'Myself', we have found five sub-themes such as "Lack of emotional communication", "Not-found spouse meeting my criteria", "My personality", "Self-narcissism or self-centeredness", "False beliefs in marriage". As for the second category of themes 'Family', three sub-themes have been found including "Family of origin conflict", "Closeness to family of origin", "Comfortable daily lives". And for the final category of themes 'Surrounding Environments and Friends', there were found three sub-themes which include "Negative effects of married friends", "Emotional support system", "Changing social atmosphere". In all there are eleven sub-themes to consider. On the basis of these results, we presented some conclusions on the reasons why single women in their thirties or forties choose not to marry. We also presented some implications of these results on population education and future research.

  • PDF

Scoring System to Predict Malignancy for MRI-Detected Lesions in Breast Cancer Patients: Diagnostic Performance and Effect on Second-Look Ultrasonography (유방암 환자의 MRI에서 발견된 병변의 악성 예측을 위한 점수체계: 진단적 능력과 이차 초음파 결정에 미치는 영향)

  • Young Geol Kwon;Ah Young Park
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.2
    • /
    • pp.379-394
    • /
    • 2020
  • Purpose To design a scoring system to predict malignancy of additional MRI-detected lesions in breast cancer patients. Materials and Methods Eighty-six lesions (64 benign and 22 malignant) detected on preoperative MRI of 68 breast cancer patients were retrospectively included. The clinico-radiologic features were correlated with the histopathologic results using the Student's t-test, Fisher's exact test, and logistic regression analysis. The scoring system was designed based on the significant predictive features of malignancy, and its diagnostic performance was compared with that of the Breast Imaging-Reporting and Data System (BI-RADS) category. Results Lesion size ≥ 8 mm (p < 0.001), location in the same quadrant as the primary cancer (p = 0.005), delayed plateau kinetics (p = 0.010), T2 isointense (p = 0.034) and hypointense (p = 0.024) signals, and irregular mass shape (p = 0.028) were associated with malignancy. In comparison with the BI-RADS category, the scoring system based on these features with suspicious non-mass internal enhancement increased the diagnostic performance (area under the receiver operating characteristic curve: 0.918 vs. 0.727) and detected three false-negative cases. With this scoring system, 22 second-look ultrasound examinations (22/66, 33.3%) could have been avoided. Conclusion The scoring system based on the lesion size, location relative to the primary cancer, delayed kinetic features, T2 signal intensity, mass shape, and non-mass internal enhancement can provide a more accurate approach to evaluate MRI-detected lesions in breast cancer patients.

Clustered Microcysts Detected on Breast US in Asymptomatic Women (무증상 여성의 유방초음파에서 발견된 군집 미세낭종)

  • Hyun Jin Kim;Jin Hwa Lee;Young Mi Park;Kyungjae Lim
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.3
    • /
    • pp.676-685
    • /
    • 2023
  • Purpose To investigate the incidence, outcomes, and imaging characteristics of clustered microcysts detected on breast US in asymptomatic women, and suggest appropriate management guidelines. Materials and Methods We identified and reviewed the lesions recorded as "clustered microcysts" on breast US performed in asymptomatic women between August 2014 and December 2019. The final diagnosis was based on pathology and imaging follow-up results for at least 12 months. Results The incidence was 1.5% and 100 patients with 117 lesions were included. Among 117 lesions, 3 (2.6%), 2 (1.7%), and 112 (95.7%) were malignant, high-risk benign, and benign lesions, respectively. The malignant lesions included two cases of ductal carcinoma in situ and one invasive ductal carcinoma. Two of them were assessed as category 4, showing mammographic suspicious microcalcifications and internal vascularity on Doppler US. The remainder was a false negative case and showed echo pattern change on the 12-month follow-up US. Conclusion The incidence of clustered microcysts on breast US in asymptomatic women was 1.5% and malignancy rate was 2.6% (3 of 117). Knowledge of outcomes and imaging features of benign and malignant clustered microcysts may be helpful for radiologists, thereby aiding categorization and management recommendations.

Comparison of Thallium-201 Scan and Tc-99m Sestamibi Scan in the Differential Diagnosis of Breast Mass (유방암 진단에 있어서 탈륨스캔과 Tc-99m MIBI 스캔의 비교)

  • Cho, Ihn-Ho;Won, Kyu-Jang;Lee, Hyung-Woo;Lee, Soo-Jung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.1
    • /
    • pp.76-83
    • /
    • 1999
  • Purpose: We performed this study to compare T1-201 and Tc-99m MIBI scans for the differentiation of malignant from benign breast mass. Materials and Methods: Thirty-eight female patients underwent T1-201 breast scan and thirty-two of them also underwent Tc-99m MIBI scan of the breast. After intravenous injection of 74-111 MBq of T1-201, early (10 minutes) and delayed (3 hours) images were obtained. Then, 555-740 MBq of Tc-99m MIBI was injected and images after 30 minutes were obtained. We compared T1-201 and Tc-99m MIBI scans with pathologic results. Results: Twenty-three patients were confirmed to have infiltrating duct carcinoma and fifteen patients to have benign breast mass by excisonal biopsy. The sensitivity of early and delayed T1-201 scan and Tc-99m MIBI scan in the detection of malignant breast lesion were 100% (23/23), 82% (18/22), and 90% (18120), respectively. The sensitivity of early T1-201 scan was significantly higher than that of delayed T1-201 scan (p<0.05). The specificity of early and delayed T1-201 scan and Tc-99m MIBI scan were 73% (l1/15), 73% (l1/15) and 83% (10/12), respectively (p: not significant). Three patients out of nine with fibroadenoma and one patient with atypical duct hyperplasia were false positive in both early and delayed T1-201 scans. The size of fibroadenoma with false positive in early and delayed T1-201 scan (4 cases) was larger than that of 11 fibroadenoma with true negative scan (p<0.01). Metastatic axillary lymph node involvement was present in fifteen patients. The sensitivity to detect metastatic nodes was 38% (5/13) for early T1-201 images, 15% (2/13) for delayed T1-201 images, 58% (7/12) for Tc-99m MIBI planar images and 67% (4/6) for Tc-99m MIBI SPECT. The sensitivity of Tc-99m MIBI planar or SPECT was significantly higher than that of delayed T1-201 images (p<0.05). Conclusion: Early T1-201 and Tc-99m MIBI scan are useful noninvasive methods to differentiate malignant from benign mass of breast Tc-99m MIBI scan was sensitive in detecting axillary lymph node metastasis in patients with breast cancer.

  • PDF

Report on the External Quality Assessment Scheme of Hepatitis Viral Markers in Korea, (2016-2017) (간염바이러스 항원항체검사 신빙도조사 결과보고 (2016-2017))

  • Cho, Eun-Jung;Choi, Ae Ran;Ryu, Ji Hyeong;Yun, So Jeong;Lee, Woochang;Chun, Sail;Min, Won-Ki;Oh, Eun-Jee
    • Laboratory Medicine and Quality Assurance
    • /
    • v.40 no.2
    • /
    • pp.51-69
    • /
    • 2018
  • As part of the immunoserology program of the Korean Association of External Quality Assessment Service, we organized two trials on the external quality assessment of hepatitis viral markers in 2016 and 2017. The hepatitis viral antigens and antibodies program consisted of 10 test items. We delivered two and three types of pooled sera specimens to 965 and 965 institutions for the first and second trials of external proficiency testing in 2016, respectively. The number of participating laboratories was 915 (94.8%) and 913 (95.0%) in the first and second trials in 2016, respectively. We also delivered three kinds of pooled sera specimens to 936 and 1,015 institutions for the first and second trials of external proficiency testing in 2017, respectively. The number of participating laboratories was 920 (98.3%) and 996 (98.1%) in the first and second trials in 2017, respectively. The most commonly tested items were hepatitis B surface antigen, followed by the antibodies to hepatitis B surface antigen, anti-hepatitis C virus, hepatitis B envelope antigen, antibodies to hepatitis B envelope antigen, anti-hepatitis A virus and antibodies to hepatitis B core antigen. The most frequently used methods for detecting viral markers were the chemiluminescence immunoassay and the electrochemiluminescence immunoassay, but they yielded a few-false positive results due to the matrix effect. The immunochromatographic assay yielded false-negative results for anti-hepatitis A virus due to low sensitivity. Continuous improvement in the quality of viral hepatitis testing through participation in the survey seems necessary.

Colonic Uptake Patterns of F-18-FDG PET in Asymptomatic Adults: Comparison with Colonoscopic Findings (무증상 성인의 F-18-FDG PET 대장 섭취양상 : 대장내시경 소견과의 비교)

  • Pai, Moon-Sun;Cho, Yoo-Kyung;Jung, Sung-Ae;Shim, Ki-Nam;Lee, Hong-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.1
    • /
    • pp.15-20
    • /
    • 2005
  • Purpose: Physiologic intestinal FDG uptake is frequently observed in asymptomatic individuals for cancer screening FDG PET Colonic FDG accumulation is a well-known confusing findings that interfere true cancer detection or cause false positive. The aim of this study was to evaluate the pattern and intensity of colonic uptake in whole body FDG PET in asymptomatic healthy adults and to correlate them with colonoscopic findings. Materials and Methods: We reviewed retrospectively 64 subjects (age: 27-87, M:F=31:33) who underwent both FDG PET and colonoscopy for cancer screening. FDG uptake patterns were classified as focal, segmental and diffuse. Maximum SUV were measured. The PET results were compared with colonoscopic and histologic findings. Results: In 13 patients FDG bowel uptake was interpreted as focal, in 17 patients as segmental and in 34 patients as diffuse uptake. Six adenomas (17.6%, average diameter=5.0 mm) were found in diffuse pattern, 7 adenomas (41.1%, 5.6 mm) in segmental and 4 adenomas and 1 adenocarcinoma (38.5%, 16.4 mm) in focal uptake pattern. In patients with focal uptake, four were non-adenomatous pathologic lesions (30.8%, 2 intestinal tuberculosis, 2 mucosal ulcer). There is no difference of mean SUV between patients with adenoma and with negative colonoscopic results in each group of intestinal FDG pattern (Diffuse: $1.7{\pm}0.1\;vs.\;1.9{\pm}0.5$, Segmental: $4.8{\pm}3.6\;vs.\;4.2{\pm}1.2$, Focal: $6.5{\pm}4.7\;vs.\;3.5{\pm}1.3$). large adenomas (>1 cm) can be detected more in the focal uptake pattern (4 out of 5) rather than in segmental (1 out of 7) or diffuse uptake (none) and had higher SUV ($6.3{\pm}4.8$) than small adenomas ($3.5{\pm}3.0$) (statistically insignificant). Conclusion: focal FDG uptake is associated more often with large adenoma and other pathologic findings in colonoscopy. Segmental uptake cannot discriminate presence of adenoma from negative results, while diffuse pattern may have more chance to be normal.

How Reliable is Sputum PCR Test in the Diagnosis of Pulmonary Tuberculosis When Sputum Smear is Negative? (객담 결핵균 도말검사가 음성일때 중합효소연쇄반응검사와 진단적 신뢰도에 관한 연구)

  • Baek, Seung-Hoon;Lee, Jae-Myung;Kang, Min-Jong;Son, Jee-Woong;Lee, Seung-Joon;Kim, Dong-Gyu;Lee, Myung-Goo;Hyun, In-Gyu;Jung, Ki-Suck;Lee, Kyung-Wha;Joe, Hyun-Chan
    • Tuberculosis and Respiratory Diseases
    • /
    • v.50 no.2
    • /
    • pp.222-228
    • /
    • 2001
  • Backgrounds : Recent technological developments have introduced a new method to identifying M. tuberculosis complex DNA in clinical samples directly. The direct amplification test (DAT) is approved for identifying M. tuberculosis complex in respiratory specimens that are smear-positive for acid-fast bacilli (AFB). When there is a discrepancy between the AFB smear and DAT, no information on their clinical utility is currently available. In this study, the diagnostic reliability of DAT was investigated in suspected pulmonary tuberculosis patients whose sputum AFB smear was negative. Methods : From June 1, 1998 through May 30, 1999, 909 patients with presumed active pulmonary tuberculosis were enrolled. A sputum AFB stain, culture, DAT and/or biopsy were performed. Using the criteria of clinical tuberculosis or confirmed tuberculosis, the positive predictive value of DAT in diagnosing pulmonary tuberculosis was investigated. Results : The positive predictive value of DAT was 82.1% by the clinically active tuberculosis criteria. However, it decreased to 61.5% when diagnosis was restricted to only to culture positive or biopsy proven cases. The false positive rate of DAT was 18.0%. Conclusion : The DAT is a valuable diagnostic method in suspected patients whose sputum AFB is was negative.

  • PDF

The Clinical Usefulness of Ultrasound-Guided Fine Needle Aspiration Cytology in Thyroid Nodules (갑상선 결절에서 초음파 유도 미세침흡인검사의 임상적 유용성)

  • Kim, Mi-Young;Park, Young-Sun
    • Journal of radiological science and technology
    • /
    • v.31 no.2
    • /
    • pp.141-147
    • /
    • 2008
  • Thyroid nodules are a common disease in clinical practice. Fine needle aspiration (FNA) is an accurate and safe method for the diagnosis of thyroid nodules. One of the limitations of FNA is the variable rate of unsatisfactory specimens, especially in small sized, deep seated or complex cystic nodules. To overcome this problem, ultrasound-guided FNA (US-FNA) has been widely used. In this study, the clinical usefulness of US-FNA cytology in thyroid nodules was investigated. Female to male ratio was 6.58:1. The incidence of nodules were 157 (43.1%) cases on the right, 130 (35.7%) cases on the left and 9 (2.5%) cases in isthmus. Total 139 cases (38.2%) belong to less than 1cm and 225 cases (61.8%) belong to more than 1cm. As for the echo type in the nodules, solid types were 255(70.1%), cystic type 39 (10.7%) cases, and the percentage of mixed type was 19.2%. The results show that US-FNA reduces the possibility of unsatisfactory cytologic specimens and the rate of false-negative diagnosis, and improves the diagnostic accuracy in investigation thyroid nodules.

  • PDF