• Title/Summary/Keyword: False Count

Search Result 30, Processing Time 0.024 seconds

Factors Associated with Indeterminate and False Negative Results of QuantiFERON-TB Gold In-Tube Test in Active Tuberculosis

  • Cho, Ki-Won;Cho, Eun-Ha;Kwon, Soo-Hoon;Im, Sang-Hyuk;Sohn, In;Song, Sook-Hee;Kim, Hye-Ok;Kim, Su-Hyun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.72 no.5
    • /
    • pp.416-425
    • /
    • 2012
  • Background: The sensitivities and specificities of interferon-gamma release assays (IGRAs) vary among different population studies, and the data on the routine use of IGRAs are limited. The aim of this study was to evaluate the role of QuantiFERON-TB Gold In-Tube (QFT-GIT) test in the diagnosis of active tuberculosis. Methods: We conducted a prospective study, enrolling 77 patients with suspected pulmonary tuberculosis (TB), at a secondary care teaching hospital in Seoul. Results: In total, 12 (15.6%) patients showed indeterminate results due to positive control failure on the QFT-GIT test. Indeterminate results were significantly associated with the elderly, history of the intensive care unit stay, lymphocytopenia, especially low CD4 count, increased C-reactive protein and decreased protein levels. Of the 77 patients, 44 (57.1%) were diagnosed with active pulmonary tuberculosis, and the percentage of false negative results of the QFT-GIT was 36.4% (vs. 31.8% with TST). In the TB group with >65 years old (n=12), the proportions of the indeterminate (33.3% vs. 3.1%) and the false negative results (58.3% vs. 25.0%) of the QFT-GIT were significantly higher than in the younger TB group (n=32). Conclusion: Indeterminate and false negative results of QFT-GIT test were not infrequent in tuberculosis, especially in the elderly. Care should be considered for the interpretation with the elderly, immunocompromised, chronic and severely diseased patients.

Studies on the Diagnosis of Subclinical Mastitis in Cows by the Measurement of the Electrical Conductivity: 1. Comparison of Various Methods of Handling Conductivity Data with the Use of California Mastitis Test and Direct Somatic Cell Count (전기전도도(電氣傳導度) 측정(測定)에 의한 유우(乳牛) 준임상형(準臨床型) 유방염(乳房炎)의 진단(診斷)에 관한 연구(硏究) 1. 전기전도도법(電氣傳導度法)과 간접검진법(間接檢診法)(CMT 및 총체세포수(總體細胞數))과의 비교(比較))

  • Kang, Byong-kyu
    • Korean Journal of Veterinary Research
    • /
    • v.24 no.1
    • /
    • pp.91-98
    • /
    • 1984
  • A total of 466 foremilk from dairy farms in Chonnam district was examined for the subclinical mastitis over a period of one year, using a method of the electrical conductivities(EC); absolute conductivity(AC) and differential conductivity(DC) and quarter difference value(QD), in relation to the California mastitis test(CMT) and the direct somatic cell count(DSCC). The compatibility and efficiency rating between the EC values and the other screening tests was conducted. Obtained results are summarized as follows. 1. A linear relationship was found between the EC values and the CMT scores and direct somatic cell counts and it was found that electrical conductivity measurements were comparable with other screening tests for diagnosing animals with mastitis. 2. Compatibilities between the EC and CMT were 70.4% in AC, 74.6% in DC and 70.7% in QD, and that of the EC and DSCC were 53.0% in AC, 63.1% in DC and 53.2% in QD. On the other hand, relative efficiency ratings of Postle's equation between EC and CMT were 37.3% in AC, 26.5% in DC and 13.6% in QD, and that of the EC and DSCC were 33.1% in AC, 20.2% in DC and 11.9% in QD. 3. In the foremilk samples collected from damaged quarters determined by EC, the false positive rate wart higher than the false negative rate, and consequently tests of EC produced lower compatibility or efficiency rating scores. These tendencies suggested that any factors other than the mastitic condition influencing the EC values might be existed.

  • PDF

The Decision Method of A Threshold in Sequence-based Anomaly Detection Sensor (순서기반 비정상행위 탐지 센서의 임계치 결정 방법)

  • Kim, Yong-Min;Kim, Min-Su;Kim, Hong-Geun;No, Bong-Nam
    • The KIPS Transactions:PartC
    • /
    • v.8C no.5
    • /
    • pp.507-516
    • /
    • 2001
  • In this paper, we implement sequence-based anomaly detection sensor using SOM and HMM, and analyze what is important information in system call and how a threshold is decided. The new filtering and reduction rules of SOM reduces the input size of HMM. This gives real-time processing to HMM-based anomaly detection sensor. Also, we introduced an anomaly count into the sensor. Due to lessened sensibility, a user easily understand easily the detection information and false-positive was decreased. And the active coordination of the threshold value makes the detection sensor adapt according to the system condition.

  • PDF

Conditional Signal-Acquisition Parameter Selection for Automated Satellite Laser Ranging System

  • Kim, Simon;Lim, Hyung-Chul;Kim, Byoungsoo
    • Journal of Astronomy and Space Sciences
    • /
    • v.36 no.2
    • /
    • pp.97-103
    • /
    • 2019
  • An automated signal-acquisition method for the NASA's space geodesy satellite laser ranging (SGSLR) system is described as a selection of two system parameters with specified probabilities. These parameters are the correlation parameter: the minimum received pulse number for a signal-acquisition and the frame time: the minimum time for the correlation parameter. The probabilities specified are the signal-detection and false-acquisition probabilities to distinguish signals from background noise. The steps of parameter selection are finding the minimum set of values by fitting a curve and performing a graph-domain approximation. However, this selection method is inefficient, not only because of repetition of the entire process if any performance values change, such as the signal and noise count rate, but also because this method is dependent upon system specifications and environmental conditions. Moreover, computation is complicated and graph-domain approximation can introduce inaccuracy. In this study, a new method is proposed to select the parameters via a conditional equation derived from characteristics of the signal-detection and false-acquisition probabilities. The results show that this method yields better efficiency and robustness against changing performance values with simplicity and accuracy and can be easily applied to other satellite laser ranging (SLR) systems.

A Selection of Threshold for the Generalized Hough Transform: A Probabilistic Approach (일반화된 허프변환의 임계값 선택을 위한 확률적 접근방식)

  • Chang, Ji Y.
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.1
    • /
    • pp.161-171
    • /
    • 2014
  • When the Hough transform is applied to identify an instance of a given model, the output is typically a histogram of votes cast by a set of image features into a parameter space. The next step is to threshold the histogram of counts to hypothesize a given match. The question is "What is a reasonable choice of the threshold?" In a standard implementation of the Hough transform, the threshold is selected heuristically, e.g., some fraction of the highest cell count. Setting the threshold too low can give rise to a false alarm of a given shape(Type I error). On the other hand, setting the threshold too high can result in mis-detection of a given shape(Type II error). In this paper, we derive two conditional probability functions of cell counts in the accumulator array of the generalized Hough transform(GHough), that can be used to select a scientific threshold at the peak detection stage of the Ghough.

The Role of Thallium-201 Scintigraphy in Bone and Soft Tissue Tumor (근골격계 종양에서 탈륨 스캔의 역할)

  • Shin, Duk-Seop
    • Journal of Yeungnam Medical Science
    • /
    • v.20 no.2
    • /
    • pp.117-128
    • /
    • 2003
  • Thallium-201 scintigraphy is used to discriminate the malignant bone tumor from the benign by qualitatively and quantitatively, and to predict the response of preoperative chemotherapy in osteosarcoma, by comparing the changes of thallium uptake ratio after chemotherapy to the tumor necrosis ratio. Thallium-201 scintigraphy scan should be done prior to surgical biopsy. PICKER Prism 2000 gamma camera with high resolution parallel hole collimator is usually used for scanning. The patient is injected with 2-3mCi of Tl-201 and the early phase is checked in 30 minutes and delayed phase in 3 hours. The scan images are visually evaluated by a blinded nuclear medicine physician. We could evaluate true positive, true negative, false positive and false negative by the comparison of results with those of biopsy, and calculate positive and negative predictive value(%), sensitivity(%), specificity(%) and diagnostic accuracy(%). For the quantitative analysis of thallium uptake, we drew the region of interest on the tumor side and contralateral normal side as mirror image, and calculated the uptake ratio with dividing the amount of gamma count in tumor side by normal side. We could calculate the percent changes of thallium uptake ratio in early and delayed phase, and compare them to the ratio of tumor necrosis. Thallium-201 scintigraphy proved as useful imaging study to discriminate malignant bone tumor from benign, but had exception in giant cell tumor and low grade malignant bone tumors. We can use T1-201 scan to differentiate the benign from the malignant tumor, and to evaluate the response of preoperative chemotherapy or radiotherapy, and to determine the residual tumor or local recurrence. For the better result, we need to have a more detail information about false positive cases and a more objective and quantitative reading technique.

  • PDF

Radionuclide identification method for NaI low-count gamma-ray spectra using artificial neural network

  • Qi, Sheng;Wang, Shanqiang;Chen, Ye;Zhang, Kun;Ai, Xianyun;Li, Jinglun;Fan, Haijun;Zhao, Hui
    • Nuclear Engineering and Technology
    • /
    • v.54 no.1
    • /
    • pp.269-274
    • /
    • 2022
  • An artificial neural network (ANN) that identifies radionuclides from low-count gamma spectra of a NaI scintillator is proposed. The ANN was trained and tested using simulated spectra. 14 target nuclides were considered corresponding to the requisite radionuclide library of a radionuclide identification device mentioned in IEC 62327-2017. The network shows an average identification accuracy of 98.63% on the validation dataset, with the gross counts in each spectrum Nc = 100~10000 and the signal to noise ratio SNR = 0.05-1. Most of the false predictions come from nuclides with low branching ratio and/or similar decay energies. If the Nc>1000 and SNR>0.3, which is defined as the minimum identifiable condition, the averaged identification accuracy is 99.87%. Even when the source and the detector are covered with lead bricks and the response function of the detector thus varies, the ANN which was trained using non-shielding spectra still shows high accuracy as long as the minimum identifiable condition is satisfied. Among all the considered nuclides, only the identification accuracy of 235U is seriously affected by the shielding. Identification of other nuclides shows high accuracy even the shielding condition is changed, which indicates that the ANN has good generalization performance.

Pedestrian Traffic Counting Using HoG Feature-Based Person Detection and Multi-Level Match Tracking (HoG 특징 기반 사람 탐지와 멀티레벨 매칭 추적을 이용한 보행자 통행량 측정 알고리즘)

  • Kang, Sung-Wook;Jung, Jin-dong;Seo, Hong-il;Lee, Hae-Yeoun
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.5 no.8
    • /
    • pp.385-392
    • /
    • 2016
  • Market analysis for a business plain is required for the success in the modern world. Most important part in this analysis is pedestrian traffic counting. A traditional way for this is counting it in person. However, it causes high labor costs and mistakes. This paper proposes an automatic algorithm to measure the pedestrian traffic count using images with webcam. The proposed algorithm is composed of two parts: pedestrian area detection and movement tracking. In pedestrian area detection, moving blobs are extracted and pedestrian areas are detected using HoG features and Adaboost algorithm. In movement tracking, multi-level matching and false positive removal are applied to track pedestrian areas and count the pedestrian traffic. Multi-level matching is composed of 3 steps: (1) the similarity calculation between HoG area, (2) the similarity calculation of the estimated position with Kalman filtering, and (3) the similarity calculation of moving blobs in the pedestrian area detection. False positive removal is to remove invalid pedestrian area. To analyze the performance of the proposed algorithm, a comparison is performed with the previous human area detection and tracking algorithm. The proposed algorithm achieves 83.6% accuracy in the pedestrian traffic counting, which is better than the previous algorithm over 11%.

Detecting Inner Attackers and Colluded nodes in Wireless Sensor Networks Using Hop-depth algorithm (Hop-depth 알고리즘을 이용한 무선 센서 네트워크상에서의 내부공격자 및 공모노드 검출)

  • Rhee, Kang-Hyeon
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.44 no.1
    • /
    • pp.113-121
    • /
    • 2007
  • Commonly, in the Sensor Network that composed with multiple nodes uses Ad-hoc protocol to communicate each other. Each sensed data packets are collected by base node and processed by Host PC. But the Ad-hoc protocol is too vulnerable to Sinkhole attack, where the intruder attracts surrounding nodes with unfaithful routing information, and then performs selective forwarding or changes the data passing through it. The Sinkhole attack increases overhead over the network and boosts energy consumption speed to decrease network's life time. Since the other attacks can be easily adopted through sinkhole attack, the countermeasure must be considered carefully. In this paper, we proposed the Hop-depth algorithm that detects intruder in Sinkhole attack and colluded nodes. First, the proposed algorithm makes list of suspected nodes and identifies the real intruder in the suspected node list through the Hop-depth count value. And recalculates colluder's path information to find the real intruder. We evaluated the performance of the proposed algorithm using NS2. We compared and analyzed the success ratio of finding real intruder, false positive ratio, false negative ratio, and energy consumption.

Validity of bag urine culture for predicting urinary tract infections in febrile infants: a paired comparison of urine collection methods

  • Kim, Geun-A;Koo, Ja-Wook
    • Clinical and Experimental Pediatrics
    • /
    • v.58 no.5
    • /
    • pp.183-189
    • /
    • 2015
  • Purpose: Catheter urine (CATH-U) and suprapubic aspiration (SPA) are reliable urine collection methods for confirming urinary tract infections (UTI) in infants. However, noninvasive and easily accessible collecting bag urine (CBU) is widely used, despite its high contamination rate. This study investigated the validity of CBU cultures for diagnosing UTIs, using CATH-U culture results as the gold standard. Methods: We retrospectively analyzed 210 infants, 2- to 24-month-old, who presented to a tertiary care hospital's pediatrics department between September 2008 and August 2013. We reviewed the results of CBU and CATH-U cultures from the same infants. Results: CBU results, relative to CATH-U culture results (${\geq}10^4$ colony-forming units [CFU]/mL) were widely variable, ranging from no growth to ${\geq}10^5CFU/mL$. A CBU cutoff value of ${\geq}10^5CFU/mL$ resulted in false-positive and false-negative rates of 18% and 24%, respectively. The probability of a UTI increased when the CBU bacterial count was ${\geq}10^5/mL$ for all infants, both uncircumcised male infants and female infants (likelihood ratios [LRs], 4.16, 4.11, and 4.11, respectively). UTIs could not be excluded for female infants with a CBU bacterial density of $10^4-10^5$ (LR, 1.40). The LRs for predicting UTIs based on a positive dipstick test and a positive urinalysis were 4.19 and 3.11, respectively. Conclusion: The validity of obtaining urine sample from a sterile bag remains questionable. Inconclusive culture results from CBU should be confirmed with a more reliable method.