• Title/Summary/Keyword: Fall-down

Search Result 295, Processing Time 0.031 seconds

Study on redundancy resolution algorithm of humanoid

  • Yoo, Dong-Su;So, Byung-Rok;Choi, Jae-Yeon;Yi, Byung-Ju;Kim, Whee-Kuk
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.2759-2764
    • /
    • 2003
  • Humans usually employ more joints than they actually need, and thus they can be categorized as a kinematically redundant system. Therefore, the behavior of the human body can be analyzed by several redundancy resolution algorithms. Different from typical industrial robots that are fixed to the ground, the COG/ZMP condition should be taken into account in the human body motion in order not to fall down. Thus a COG/ZMP stability index is employed as a measure of stability. Kinematic redundancy inherent in the human body can be exploited to satisfy the COG/ZMP condition. Simulation result shows that the COG/ZMP condition can be satisfied by exploiting the null space motion of the kinematically redundant human body model.

  • PDF

Visual Bean Inspection Using a Neural Network

  • Kim, Taeho;Yongtae Do
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2003.09a
    • /
    • pp.644-647
    • /
    • 2003
  • This paper describes a neural network based machine vision system designed for inspecting yellow beans in real time. The system consists of a camera. lights, a belt conveyor, air ejectors, and a computer. Beans are conveyed in four lines on a belt and their images are taken by a monochrome line scan camera when they fall down from the belt. Beans are separated easily from their background on images by back-lighting. After analyzing the image, a decision is made by a multilayer artificial neural network (ANN) trained by the error back-propagation (EBP) algorithm. We use the global mean, variance and local change of gray levels of a bean for the input nodes of the network. In an our experiment, the system designed could process about 520kg/hour.

  • PDF

Traumatic Diaphragmatic Injuries (외상성 횡격막 손상)

  • 오창근
    • Journal of Chest Surgery
    • /
    • v.24 no.6
    • /
    • pp.579-584
    • /
    • 1991
  • The records of 25 patients with traumatic diaphragmatic injuries seen at Chosun University Hospital from February 1977 to May 1991 were reviewed. We treated 20 male and 5 female patients ranging in age from 6 to 72 years. The diaphragmatic injuries were due to blunt trauma in 19 cases[traffic accident 13, fall down 4, compression injury 2] and penetrating trauma in 6 cases[stab wound 5, gun shot 1]. Most common symptoms were dyspnea[72%], chest pain[56%] and abdominal pain [40%], Chest X-ray were normal in 7 cases[28%] and 22 cases[88%] were diagnosed or suspected as diaphragmatic injuries preoperatively. The repair of 25 cases were performed with thoracic approach in 16 cases, thoracoabdominal approach in 6 cases and abdominal approach in 3 cases. Postoperative complications included atelectasis, wound infection and empyema. there was no postoperative death.

  • PDF

Surgical Treatment of Thoracic Injuries Combined with Abdominal Injuries (복부 손상을 동반한 흉부손상 환자의 외과적 치료)

  • Jeong, Seong-Un;Kim, Byeong-Jun;Lee, Seong-Gwang
    • Journal of Chest Surgery
    • /
    • v.28 no.9
    • /
    • pp.842-846
    • /
    • 1995
  • Recently, the trauma patients have been markedly increasing due to the vast increase of traffic accident, industrial disaster, incidental accident and violence. The authors have analysed of 22 patients of thoracic injuries combined with abdominal injuries and summarized as follows. The ratio of male to female was 3.4:1 and their age distribution was from 5 years to 68 years and mean age was 34.4 years. The etiologies of injury were traffic accident, stab wound, fall down and violence. Associated injuries were fractures, bowel perforation, kidney rupture, head injury, liver laceration, spleen rupture and so forth. The modes of treatment were closed thoracostomy, repair of diaphragm, ruptured bowel repair, explo-thoracotomy, splenectomy, hepatic lobectomy in this order of frequency. The postoperative complications were atelectasis, wound infection, pneumonia, empyema, acute renal failure, respiratory failure and bleeding. The mortality rate was 13.6% [3/22 and the causes of death were respiratory failure 1 case, acute renal failure 1 case and hypovolemic shock 1 case.

  • PDF

Traumatic Diaphragmatic Injuries - A report of 23 cases - (외상성 횡격막 손상: 23례 보고)

  • 최세영
    • Journal of Chest Surgery
    • /
    • v.24 no.2
    • /
    • pp.197-201
    • /
    • 1991
  • Twenty-three patients with traumatic diaphragmatic injuries treated at the Department of Thoracic and Cardiovascular Surgery, Keimyung University Dongsan Medical Center from Aug. 1978 to Nov. 1990 were reviewed. There were 19 male and 4 female patients. The age distribution was ranged from 1.5 to 72 years, with a mean age of 34.3 years. Sixteen patients had blunt trauma[traffic accident 14, fall down 2], and 7 had penetrating injuries[stab wound 6, broken glass 1]. Sixteen [70 percent]of the injuries occurred on the left side and 7[30 percent] on the right side. Fifteen patients were operated on during the acute phase, 5 patients during the latent phase, 2 patients during the obstructive phase. The surgical approach in 20 patients was through a thoracotomy; in 2 patients, a thoracoabdominal incision was necessary, and in 1 patient, a laparotomy was performed. Herniated organs in thorax included stomach[10], colon[5], small bowel[5], spleen[4], liver[2]. Postoperative complications included wound infection, empyema, pneumonia, hepatitis and respiratory failure. There were 3 postoperative deaths, 2 with cerebral dysfunction and 1 with sepsis.

  • PDF

Surgical Management of Chronic Pulmonary Embolism - Surgical treatment and perioperative problems - (만성 페색전증의 외과적 요법수술 및 수술 전후 문제)

  • 김응수
    • Journal of Chest Surgery
    • /
    • v.20 no.1
    • /
    • pp.139-147
    • /
    • 1987
  • in general rapid and complete resolution of pulmonary emboli, even massive, is the natural history. However, rarely, the emboli do not resolve but rather became fibrotic organization and densely adherent to the arterial wall, therefore, may lead to significant clinical disability. In patients with chronic pulmonary embolism, medical management usually has little effect and only surgical treatment can offer improvement. The case was 30-year-old man who had admission to the Hanyang University Hospital due to fall-down from 11th floor 407 days before operation and then transferred to our department for surgical management under the diagnosis of chronic pulmonary embolism, Pulmonary angiogram demonstrated multifocal thromboembolism with infarction and lung scans showed no improvement in spite of anticoagulant and thrombolytic therapy. At median sternotomy for pulmonary artery thromboembolectomy, the well organized and multiple septic emboli could be removed by gallstone forceps. But reoperation of left upper lobectomy was performed because of the repeated hemoptysis and suspicious pulmonary arterio-bronchial fistula 19 days postoperatively. Despite of ventilatory support and drug treatment, the patient died due to right heart failure associated with cor pulmonale 27 days after first operation. Discussion of the operative and perioperative problems are offered.

  • PDF

A Study on the Characteristic of Capacitor Current by Voltage Harmonics (전압 고조파에 의한 커패시터 전류 특성 해석)

  • Kim, Jong-Gyeum;Kim, Sung-Hyun;Kim, Il-Jung
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.2
    • /
    • pp.148-153
    • /
    • 2009
  • As the increasing of non-linear load, we have a growing interest in power quality. Power quality has come to the voltage quality. Voltage harmonics consist in at the PCC by the non-linear load. Capacitor is generally used for the power compensation and as the passive filter by the serial connection with reactor. Capacitor has low impedance as the frequency increases, so easily fall down by the harmonic component of non-linear load. Small voltage of low-order acts on quite a few at the capacitor by the current increase. In this paper, we measured the magnitude and angle of voltage at the PCC and calculated under the same condition. we checked out that lower voltage of higher order produces current magnification.

Tracking Control for Biped Robot (이족 보행 로봇을 위한 추적 제어)

  • 이용권;박종현
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.315-318
    • /
    • 1995
  • In this paper, an optimal trunk trajectory for stable walking of biped robots is expressed as a simple differential equation, which is then solved by numerical methods. We used ZMP (Zero Moment Point), the virtual total ground reaction point within the region of the supporting food, as the criterion of stability of biped robot walking. If the ZMP is located outside of the stable region in dynamic walking, biped robots fall down. The biped robot considered in this paper consists of two legs and a trunk. The trajectories of the two legs and the ZMP of the biped robot are determined such that they are similar ti those of a human. Based upon those trajectories, the trunk trajectory is solved by numerically integrating differential dynamic equations. Leg motions are controlled by the computed torque control method. The effectiveness of control algorithm as well as the trajectories is confirmed by computer simulations.

  • PDF

A Study on Stable Motion Control of Biped Robot with 18 Joints (18관절 2족보행 로봇의 안정한 모션제어에 관한연구)

  • Park, Youl-Moon;Thu, Le Xuan;Won, Jong-Beom;Park, Sung-Jun;Kim, Yong-Gil
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.17 no.2
    • /
    • pp.35-41
    • /
    • 2014
  • This paper describes the obstacle avoidance architecture to walk safely around in factory and home environment, and presents methods for path planning and obstacle avoidance for the humanoid robot. Solving the problem of obstacle avoidance for a humanoid robot in an unstructured environment is a big challenge, because the robot can easily lose its stability or fall down if it hits or steps on an obstacle. We briefly overview the general software architecture composed of perception, short and long term memory, behavior control, and motion control, and emphasize on our methods for obstacle detection by plane extraction, occupancy grid mapping, and path planning. A main technological target is to autonomously explore and wander around in home environments as well as to communicate with humans.

Diffusion Modelling of Cold Discharge on Coastal waters (연안역의 냉배수 확산모델링)

  • Kim, Jong-Kyu;Kim, Jong-Hwa
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.13 no.2
    • /
    • pp.132-145
    • /
    • 2001
  • The cold discharge from LNG(liquefied natural gas) terminal makes the water temperature around the terminal fall down. This temperature reduction may result in serious changes on marine ecosystem of the coastal area. The numerical model experiments of material transport and tidal circulation in the inner bay, Chinhae Bay are investigated in the dispersion of cold discharge from LNG terminal. The condition of ambient water is exposed to tide, tidal current and cold discharge temperature. Simple numerical model experiments highlight the importance of tidal circulation and cold discharge at each case and some results are discussed. The results of this study can be used as the guideline for the site selection of LNG terminals and long-term marine environmental impact assessment.

  • PDF