• Title/Summary/Keyword: Failure wave

Search Result 312, Processing Time 0.03 seconds

Research on anti-seismic property of new end plate bolt connections - Wave web girder-column joint

  • Jiang, Haotian;Li, Qingning;Yan, Lei;Han, Chun;Lu, Wei;Jiang, Weishan
    • Steel and Composite Structures
    • /
    • v.22 no.1
    • /
    • pp.45-61
    • /
    • 2016
  • The domestic and foreign scholars conducted many studies on mechanical properties of wave web steel beam and high-strength spiral stirrups confined concrete columns. Based on the previous research work, studies were conducted on the anti-seismic property of the end plate bolt connected wave web steel beam and high-strength spiral stirrups confined concrete column nodes applied with pre-tightening force. Four full-size node test models in two groups were designed for low-cycle repeated loading quasi-static test. Through observation of the stress, distortion, failure process and failure mode of node models, analysis was made on its load-carrying capacity, deformation performance and energy dissipation capacity, and the reliability of the new node was verified. The results showed that: under action of the beam-end stiffener, the plastic hinges on the end of wave web steel beam are displaced outward and played its role of energy dissipation capacity. The study results provided reliable theoretical basis for the engineering application of the new types of nodes.

Prediction of the Failure Stress of Tofu Texture Using a Delay Time of Ultrasonic Wave (초음파의 지연 시간을 이용한 두부 조직의 물성변화 예측에 관한 연구)

  • Kim, Hak-Jung;Hahm, Young-Tae;Kim, Byung-Yong
    • Applied Biological Chemistry
    • /
    • v.38 no.4
    • /
    • pp.325-329
    • /
    • 1995
  • Changes in the physical properties of soybean curd upon the processing conditions such as coagulant concentration, heating temperature and molding pressure were determined by using a failure stress and residual delay time of ultrasonic wave(5 MHz). Maximum failure stress of Tofu was obtained at the 0.3% $CaCl_2$ coagulant concentration, $95^{\circ}C$ heating temperature and greater molding pressure, respectively, whereas the delay time is inverse proportion to the failure stress value. The results of the multiple regression analysis with factorial design showed that the model equation consisted with delay time and processing conditions gave the good prediction of the Tofu failure stress.

  • PDF

A Study on Fatigue Damage Accumulation of MMC using Ultrasonic Wave and Acoustic Emission (초음파와 AE기법을 이용한 금속복합재료의 피로손상진전 평가)

  • 이진경;이준현
    • Composites Research
    • /
    • v.13 no.4
    • /
    • pp.1-10
    • /
    • 2000
  • SiC particulate reinforced metal matrix composites(MMCs) are emerging as candidate materials for the automobile and aerospace industries due to their significant increase in elastic modulus and strength compared to conventional metallic materials. However, in order to make successful application of MMCs, it is very important to understand micro-failure mechanism under cyclic loading because failure mechanism of MMC is dominated by accumulation of micro-failure due to applied loading. In this study, ultrasonic Lamb wave and acoustic emission(AE) have been used to monitor microscopic damage accumulation under cyclic loading for SiC particulate reinforced metal matrix composite(SiCp/A356). It was found that the change in velocity and attenuation of ultrasonic Lamb wave due to the increase of loading cycles could be characterized by three different stages corresponding to the microscopic fracture processes. The characteristic of AE signal at each stage was analyzed and discussed by comparing with the change of ultrasonic characteristic in MMCs.

  • PDF

Development of the partial discharge detecting equipment using electromagnetic wave in deteriorated insulator (배전용 불량애자에서의 전자파 부분방전 검출장치 개발)

  • Kang, C.W.;Song, I.K.;Kim, J.Y.;Lee, B.S.;Kang, D.S.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1667-1669
    • /
    • 2001
  • The clack of Insulator, which results from internal or external surges such as electrical, mechanical, and thermal stress, might cause ground fault and a power failure without proper repairs. In order to minimize losses caused by a short-term or long-term power failure, it is necessary to detect the deteriorated insulator as early as possible. To do so, we will develop a new device, which can detect and trace an deteriorated insulator by monitoring its physical change the variation of frequency spectrum. This device will do so by finding a Periodic wave sharp (120 Hz), a peculiar wave generated by defused electricity.

  • PDF

Failure Analysis of RF SAW Filter by High Temperature Storage Test (고온저장시험에 의한 RF SAW Filter의 고장분석)

  • Kim, Young-Goo;Kim, Tae-Hong;You, Jong-Jun
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2003.11a
    • /
    • pp.140-144
    • /
    • 2003
  • To investigate failure analysis of surface acoustic wave (SAW) filter for radio frequency, high temperature storage test was carried out. The failure criteria were insertion loss at passband and rejection level at stopband. As a result, the insertion loss at passband increase about 4 dB was due to damages of interdigital transducer (IDT). That is caused by poor adhesion between metal electrode(AI) and piezoelectric substrate and defects on a manufacturing process. This result indicates that good adhesion between electrode and ceramic substrate is important factor And also we investigated the demage factors of electrode. Screen possible of saw filter using high temperature storage test(HTOL) in the manufacturing phase be presented.

  • PDF

Real-time Failure Detection of Composite Structures Using Optical Fiber Sensors (광섬유 센서를 이용한 복합재 구조물의 실시간 파손감지)

  • 방형준;강현규;류치영;김대현;강동훈;홍창선;김천곤
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2000.11a
    • /
    • pp.128-133
    • /
    • 2000
  • The objective of this research is to develop real-time failure detection techniques for damage assessment of composite materials using optical fiber sensors. Signals from matrix cracking or fiber fracture in composite laminates are treated by signal processing unit in real-time. This paper describes the implementation of time-frequency analysis such as the Short Time Fourier Transform(STFT) to determine the time of occurrence of failure. In order to verify the performance of the optical fiber sensor for stress wave detection, we performed pencil break test with EFPI sensor and compared it with that of PZT. The EFPI sensor was embedded in composite beam to sense the failure signals and a tensile test was performed. The signals of the fiber optic sensor when damage occurred were characterized using STFT and wavelet transform. Failure detection system detected the moment of failure accurately and showed good sensitivity with the infinitesimal failure signal.

  • PDF

The Susceptibility of LNA(Low Noise Amplifier) Due To Front-Door Coupling Under Narrow-Band High Power Electromagnetic Wave (안테나에 커플링되는 협대역 고출력 전자기파에 대한 저잡음 증폭기의 민감성 분석)

  • Hwang, Sun-Mook;Huh, Chang-Su
    • Journal of IKEEE
    • /
    • v.19 no.3
    • /
    • pp.440-446
    • /
    • 2015
  • This study has examined susceptibility of LNA(Low Noise Amplifier) due to Front-Door Coupling under Narrow-Band high power electromagnetic wave. M/DFR(Malfunction/Destruction Failure Rate) was measured to investigate the diagnostic of IC test. In addition, decapsulation analysis was used to understand the inside of the chip state in LNA devices. The experiments is employed as an open-ended waveguide to study the destruction effects of LNA using a 2.45 GHz Magnetron as a high power electromagnetic wave. The susceptibility level of LNA was assessed by electric field strength, and its failure modes were observed. The malfunction of LNA device has showed as the type of self-reset and power-reset. The electric field strength of malfunction threshold is 524 V/m and 1150 V/m respectively. Also, he electric field of destruction threshold is 1530 V/m. Three types of damaged LNA were observed by decapsulation analysis: component, onchipwire, and bondwire destruction. Based on these results, the susceptibility of the LNA can be applied to a database to help elucidate the effects of microwaves on electronic equipment.

Initial Electrocardiographic Changes associated with Clinical Severity in Acute Organophosphate Poisoning (급성 유기인계 중독과 관련된 초기 심전도 변화)

  • Lee, Hwan-Jung;Yoon, Jae-Chol;Jeong, Tae-O;Jin, Young-Ho;Lee, Jae-Baek
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.7 no.2
    • /
    • pp.69-76
    • /
    • 2009
  • Purpose: Various electrocardiogram (ECG) changes can occur in patients with acute organophosphate poisoning (OPP) and may be associated with the clinical severity of poisoning. The present study aimed to evaluate the extent and frequency of ECG changes and cardiac manifestations, and their association with acute OPP clinical severity. Methods: Seventy-two adult patients admitted to our emergency department with a diagnosis of acute OPP were studied retrospectively. ECG changes and cardiac manifestations at admission were evaluated. ECG changes between respiratory failure (RF) group and no respiratory failure (no RF) groups were compared. Results: Prolongation of QTc interval (n=40, 55.6%) was the most common ECG change, followed by sinus tachycardia (n=36, 50.0%). ST-T wave changes such as ST segment elevation or depression and T wave change (inversion or non-specific change) were evident in 16 patients (22.2%). Prolongation of QTc interval was significantly higher in the RF group compared with the no RF group (p=0.03), but was not an independent predictor for RF in acute OPP (OR; 4.00, 95% CI; 0.70-23.12, p=0.12). Conclusion: While patients with acute OPP can display ECG changes that include prolongation of QTc interval, sinus tachycardia, and ST-T wave changes at admission, these changes are not predictors of respiratory failure.

  • PDF

Ultrasonic Evaluation of Creep Damage in 316LN Stainless Steel

  • Yin, Song-Nan;Hwang, Yeong-Tak;Yi, Won
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.8 no.4
    • /
    • pp.33-37
    • /
    • 2007
  • Creep failure of 316LN stainless steel (SS) occurs due to the nucleation and growth of cracks. An investigation was performed to correlate the creep damage with ultrasonic wave speeds and angular frequencies using creep-tested 316LN SS specimens. Ultrasonic wave measurements were made in the direction of and perpendicular to the loading using contact probes with central frequencies of 10, 15, and 20 MHz. We found that the angular frequency and wave speed decreased with increasing creep time to rupture by analyzing the ultrasonic signals from the 15 and 20 MHz probes. Therefore, the creep damage was sensitive to the angular frequency and wave speed of ultrasonic waves.

Ocular Lens Test using Elastic Wave (탄성파를 이용한 안경렌즈 검사)

  • Joung, Maeng-Sig;Cho, Hyun-Soo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.4 no.1
    • /
    • pp.37-43
    • /
    • 1999
  • Ocular lens failure can be verified by measuring the elastic wave velocity diffraction patterns of monochromatic wave applied with elastic wave were detected using optical heterodyne method. The elastic wave velocity was measured by analysing the diffraction patterns. According to measured results of the longitudinal elastic wave velocity of the middle index-refraction and high index-refraction lens are 6588.5575 m/s and 3973.53 m/s, respectively.

  • PDF