• 제목/요약/키워드: Failure of fixation

검색결과 161건 처리시간 0.022초

Multiple Spinal Revision Surgery in a Patient with Parkinson's Disease

  • Malla, Hridayesh Pratap;Kim, Min Ki;Kim, Tae Sung;Jo, Dae Jean
    • Journal of Korean Neurosurgical Society
    • /
    • 제59권6호
    • /
    • pp.655-658
    • /
    • 2016
  • Parkinson's disease (PD) patients frequently have several spinal deformities leading to postural instabilities including camptocormia, myopathy-induced postural deformity, Pisa syndrome, and progressive degeneration, all of which adversely affect daily life activities. To improve these postural deformities and relieve the related neurologic symptoms, patients often undergo spinal instrumentation surgery. Due to progressive degenerative changes related to PD itself and other complicating factors, patients and surgeons are faced with instrument failure-related complications, which can ultimately result in multiple revision surgeries yielding various postoperative complications and morbidities. Here, we report a representative case of a 70-year-old PD patient with flat back syndrome who had undergone several revision surgeries, including anterior and posterior decompression and fusion for a lumbosacral spinal deformity. The patient ultimately benefitted from a relatively short segment fixation and corrective fusion surgery.

축추 이하 경추손상 환자에서 외상성 탈구에 의한 도수 정복의 실패 요인의 분석과 수술적 치료에 대한 분석 (Analysis of Surgical Treatment and Factor Related to Closed Reduction Failure for Patients with Traumatically Locked Facets of the Subaxial Cervical Spine)

  • 팽성화
    • Journal of Trauma and Injury
    • /
    • 제25권1호
    • /
    • pp.7-16
    • /
    • 2012
  • Purpose: Cervical dislocations with locked facets account for more than 50% of all cervical injuries. Thus, investigating a suitable management of cervical locked facets is important. This study examined factors of close reduction failure in traumatically locked facets of the subaxial cervical spine patients to determine suitable surgical management. Methods: We retrospectively analyzed of the case histories of 28 patients with unilateral/bilateral cervical locked facets from Nov. 2004 to Dec. 2010. Based on MRI evaluation of disc status at the injury level, we found unilateral dislocations in 9 cases, and bilateral dislocations in 19 cases, The patients were investigated for neurologic recovery, closed reduction rate, factors of the close reduction barrier, fusion rate and period, spinal alignment, and complications. Results: The closed reduction failed in 23(82%) patients. Disc herniation was an obstacle to closed reduction (p=0.015) and was more frequent in cases involving a unilateral dislocation (p=0.041). The pedicle or facet fracture was another factor, although some patients showed aggravation of neurologic symptoms, most patients had improved by the last follow up. The kyphotic angle were statistically significant (p=0.043). Sixs patient underwent anterior decompression/fusion, and 15 patients underwent circumferential fusion, and 7 patients underwent posterior fusion. All patients were fused at 3 months after surgery. The complications were 1 case of CSF leakage and 1 case of esphageal fistula, 1 case of infection. Conclusion: We recommend closed reduction be performed as soon as possible after injury to maximize the potential for neurological recovery. Patients fot whom closed reduction of the cervical locked facets have a higher incidence of anatomic obstacles to reduction, including facet fractures and disc herniation. Immediate direct open anterior reduction or circumferential fixation/fusion of locked cervical facets is recommended as a treatment of choice for traumatic locked cervical facet patients after closed reduction failure.

이종 조직판막의 재치환수술 (Replacement of the Xenograft Cardiac Valves)

  • 김종환
    • Journal of Chest Surgery
    • /
    • 제21권4호
    • /
    • pp.619-629
    • /
    • 1988
  • The increasing number of replacement of the substitute cardiac valves were seen in these 2 years. Out of a total 1,408 patients with cardiac valve replacement, 54 required replacement of the substitute valves. Fifty-nine substitute valves replaced were 43 in mitral, 14 in aortic and 2 in tricuspid positions; and they were 36 Ionescu-Shiley, 15 Hancock and 3 Angell-Shiley bioprosthetic valves and 3 St. Jude Medical and 2 Bjork-Shiley prosthetic valves. Primary tissue failure was the most frequent reason of replacement[38 patients] followed by paravalvular leak[9 patients], prosthetic valve endocarditis[6 patients] and valve thrombosis[1 patient] in order. The most pronounced pathology of the failed xenograft valves seen in the primary tissue failure group was calcification and fixation of the cusps with or without tear and defect of the cuspal tissue. The operative mortality rate was 7.4%. Fifty early survivors were followed up for a total of 82.6 patient-years and there was no late death. Actuarial survival rate was 92.3*3.8% at 6 years after surgery. Although the definite tendency toward early and accelerated degeneration of the xenograft valves has been seen in patients younger than 20 to 25 years of age, no strict age limit from where the tissue failure slows down could be determined. The requirement of the ideal substitute valves would be the durability of the recently developed mechanical prostheses armed with the low thrombogenicity of the bioprostheses. At the present time, the need of compromise in selection between less thrombogenic bioprosthetic and more durable mechanical valves should be stressed. The difficulty in choice is yet important in patients of middle age and children where the use of homograft valves may be one of the solution despite of certain limitations from sociomedical reasons.

  • PDF

Impact of Screw Type on Kyphotic Deformity Correction after Spine Fracture Fixation: Cannulated versus Solid Pedicle Screw

  • Arbash, Mahmood Ali;Parambathkandi, Ashik Mohsin;Baco, Abdul Moeen;Alhammoud, Abduljabbar
    • Asian Spine Journal
    • /
    • 제12권6호
    • /
    • pp.1053-1059
    • /
    • 2018
  • Study Design: Retrospective review. Purpose: To detect the effect of cannulated (poly-axial head) and solid (mono-axial head) screws on the local kyphotic angle, vertebral body height, and superior and inferior angles between the screw and the rod in the surgical management of thoracolumbar fractures. Overview of Literature: Biomechanics studies showed that the ultimate load, yield strength, and cycles to failure were significantly lower with cannulated (poly-axial head) pedicle comparing to solid core (mono-axial head). Methods: The medical charts of patients with thoracolumbar fractures who underwent pedicle screw fixation with cannulated or solid pedicle screws were retrospectively reviewed; the subjects were followed up from January 2011 to December 2015. Results: Total 178 patients (average age, $36.1{\pm}12.4years$; men, 142 [84.3%]; women, 28 [15.7%]) with thoracolumbar fractures who underwent surgery and were followed up at Hamad Medical Corporation were classified, based on the screw type as those with cannulated screws and those with solid screws. The most commonly affected level was L1, followed by L2 and D12. Surgical correction of the local kyphotic angle was significantly different in the groups; however, there was no significant difference in the loss of correction of the local kyphotic angle of the groups. Surgical correction of the reduction in the vertebral body height showed statistical significance, while the average loss of correction in the reduction of the vertebral body height was not significantly different. The measurement of the angles made by the screws on the rods was not significantly different between the cannulated (poly-axial head) and solid (mono-axial head) screw groups. Conclusions: Solid screws were superior in terms of providing increased correction of the kyphotic angle and height of the fractured vertebra than the cannulated screws; however, no difference was noted between the screws in the maintenance of the superior and inferior angles of the screw with the rod.

견관절 오구돌기 골절의 고정 후 발생한 오구돌기하 충돌증후군 - 증례 보고 - (Subcoracoid impingement After the Fixation of the Fractured Coracoid Process -A Case Report-)

  • 구정회;조형래;조수현;황태혁;박만준;최재혁
    • 대한관절경학회지
    • /
    • 제14권3호
    • /
    • pp.192-195
    • /
    • 2010
  • 상완골두의 전상방부와 전방 오구견봉 궁 사이의 비정상적인 접촉으로 인해 발생되는 오구돌기하 충돌증후군은 견관절 전방부 동통을 유발하는 비교적 드문 질환이다. 이는 견관절부의 수술적 치료로 인해 오구돌기와 소결절 사이의 해부학적 관계가 변형되어 견갑하근과 점액낭을 포함한 주변 연부조직의 충돌을 유발 하게 된다. 저자들은 오구돌기 골절을 유관나사를 이용해 고정한 환자에서 오구돌기하 공간의 협소화로 인해 견갑하건 파열을 동반하는 오구돌기하 충돌증후군을 경험하였다. 관절경하에서 유관나사 제거 및 견갑하건 봉합 시행 후 술전 환자의 증상은 소실되었다. 오구돌기하 충돌증후군은 견관절 수술 후 지속적 견관절 동통을 유발하는 원인 중의 하나가 될 수 있다.

  • PDF

Prevention of Implant Malposition in Inframammary Augmentation Mammaplasty

  • Kim, Yoon Ji;Kim, Yang Woo;Cheon, Young Woo
    • Archives of Plastic Surgery
    • /
    • 제41권4호
    • /
    • pp.407-413
    • /
    • 2014
  • Background Implant malposition can produce unsatisfactory aesthetic results after breast augmentation. The goal of this article is to identify aspects of the preoperative surgical planning and intraoperative flap fixation that can prevent implant malposition. Methods This study examined 36 patients who underwent primary dual plane breast augmentation through an inframammary incision between September 1, 2012 and January 31, 2013. Before the surgery, preoperative evaluation and design using the Randquist formula were performed. Each patient was evaluated retrospectively for nipple position relative to the breast implant and breast contour, using standardized preoperative and postoperative photographs. The average follow-up period was 10 months. Results Seven of 72 breasts were identified as having implant malposition. These malpositions were divided into two groups. In relation to the new breast mound, six breasts had an inferiorly positioned and one breast had a superiorly positioned nipple-areolar complex. Two of these seven breasts were accompanied with an unsatisfactory breast contour. Conclusions We identified two main causes of implant malposition after inframammary augmentation mammaplasty. One cause was an incorrect preoperatively designed nipple to inframammary fold (N-IMF) distance. The breast skin and parenchyma quality, such as an extremely tight envelope, should be considered. If an extremely tight envelope is found, the preoperatively designed new N-IMF distance should be increased. The other main cause of malposition is failure of the fascial suture from Scarpa's fascia to the perichondrium through an inframammary incision. As well, when this fixation is performed, it should be performed directly downward to the perichondrium, rather than slanted in a cranial or caudal direction.

Follow-up Comparison of Two Different Types of Anterior Thoracolumbar Instrumentations in Trauma Cases : Z-plate vs. Kaneda Device

  • Park, Jung-Keun;Kim, Keun-Su
    • Journal of Korean Neurosurgical Society
    • /
    • 제41권2호
    • /
    • pp.77-81
    • /
    • 2007
  • Objective : In a variety of thoracolumbar diseases, corpectomy followed by interbody bone graft and anterior instrumentation has allowed direct neural decompression and reconstruction of the weight-bearing column by short segments fusion. In this study, we compared spinal stability of the two different anterior thoracolumbar instruments : Z-plate and Kaneda device representing plate and two-rods type, respectively. Methods : A retrospective review was performed for all the patients with thoracolumbar diseases or traumas treated with anterior corpectomy, autologous iliac bone graft, and fixation with instruments from 1996 to 2000. For the anterior instrumentation, Z-plate or Kaneda device was used for 24 [M:F=5:9, average age=37] and 12 [M:F=9:3, average age=41] patients, respectively. The plain AP and lateral flexion-extension films were taken immediately after surgery and at each follow-up. The sagittal and coronal Cobb's angles at the operation segments were used to observe the change of initial fixation status. The surgical time length and bleeding amount of the two groups were compared. Intra-operative and post-operative instrument associated complications were evaluated. Student t-test was used for statistical analysis and p-value less than 0.05 was considered to be significant. Results : Mean follow-up durations for Z-plate and Kaneda device were 24 and 21 months, respectively. The fusion rate was 91% for Z-plate and 100% for Kaneda device. Two cases of Z-plate group showed instrumentation failure during the follow up period, in which additional surgery was necessary. The mean differences of sagittal Cobb's angles among the AP images immediate after surgery and at follow-up were 7 and 2 degrees for Z-plate and Kaneda device, respectively [p<0.05]. The mean differences of coronal Cobb's angles were 5 and 2 degrees for Z-plate and Kaneda device, respectively [p<0.05]. No Intra-operative complication has occurred in both groups. There was no difference in surgery time and bleeding amount between two groups. Conclusion : We think that Kaneda device [rod type] is stronger than Z-plate [plate type] to keep the spinal stability after anterior thoracolumbar surgery.

상완골 경부 이분 골절에서 T형 금속판을 이용한 치료 (Treatment of Two-Part Fracture of Humerus Neck Using T Plate Fixation)

  • 남일현;안길영;윤호현;김재철;문기혁
    • Clinics in Shoulder and Elbow
    • /
    • 제9권1호
    • /
    • pp.34-41
    • /
    • 2006
  • Purpose: This study is to analyze the result and complications of internal fixation with T-plate for two-part fracture of the neck of the humerus. Materials and Methods: The clinical results of fourteen patients who had been performed with this method mentioned above were reviewed. Their average age was 49.6. Postoperative mean follow up period was 24.1 months. Radiological evaluation was done by Kronberg's and shoulder function by Neer's. Results: By Kronberg evaluation, nine cases were good, two cases acceptable and three cases poor. By Neer's, mean score of shoulder function was 77.6 and 4 cases were excellent, one satisfactory, five unsatisfactory and four failure. The complications were the sfiff shoulder, loss of reduction and avascular necrosis of humeral head. Conclusion: In this study, there were differences according to the age. And we obtained an unsatisfactory result in patients over 50 years old. We consider that in patients over 50 years old, the differences were due to the muscle weakness through wide surgical approaches, postoperative implant loosening or the stiffness caused by poor rehabilitation.

골연부 종양에서 저온 열처리한 자가골을 이용한 재건술 (Autogenous Low Heat Treated Bone Graft for Bone Reconstruction in Bone and Soft Tissue Tumors)

  • 전대근;이종석;김석준;조완형;곽봉준;이수용
    • 대한골관절종양학회지
    • /
    • 제4권2호
    • /
    • pp.81-87
    • /
    • 1998
  • Although autoclaved autogenous bone reconstruction is one of the established procedures, it may have some problems in bone regeneration and mechanical property. The purpose of this study is to evaluate the efficacy of more biologic and anatomical reconstruction where allograft is not readily available. From Aug.1991 to Feb. 1996 the authors analyzed 32 cases of reconstruction with autogenous low heat treated bone. Autogenous graft sites were humerus 4, tibia 4, pelvis 9, and 15 femur. Average follow-up period was 23(range;12-51) months. There were 49 graft-host junctional sites. Diaphysis was 22, metaphysis 10, and flat bone 17. Average duration of healing for the 38 united sites was 7 months. Average union time for each anatomical area 8 months in 19 diaphysis, 12 months in 7 metaphysis, and 12.7 months in 12 flat bone(pelvis). Eleven nonunion sites consisted of 3 diaphysis(3/22), 3 metaphysis(3/10), and 5 flat bone(5/17). Complications other than nonunion were local recurrence(4), bone resorption(3), graft fracture(2), osteomyelitis(1), metal failure(2), and wound infection(1). Initial bone quality and stable fixation technique was important for union rate. Plate and screw is a good method for diaphyseal lesion. Metaphyseal and flat bone are weak area for rigid fixation and one stage augmentation with iliac bone graft can be a salvage procedure.

  • PDF

Minimally Invasive Percutaneous Plate Osteosynthesis via a Deltoid-splitting Approach with Strut Allograft for the Treatment of Displaced 3- or 4-part Proximal Humeral Fractures

  • Noh, Young-Min;Kim, Dong Ryul;Kim, Chul-Hong;Lee, Seung Yup
    • Clinics in Shoulder and Elbow
    • /
    • 제21권4호
    • /
    • pp.220-226
    • /
    • 2018
  • Background: This study introduces a surgical technique with good clinical outcome useful in the treatment of osteoporotic displaced 3- or 4-part proximal humeral fractures. Methods: From May 2014 to February 2016, 16 patients with displaced 3- or 4-part proximal humeral fractures were treated by application of a locking plate with an endosteal strut allograft via a deltoid splitting approach with a minimum follow-up of 12 months. The allograft was inserted through a fractured gap of the greater tuberosity to support the humeral head and then fixed by a locking plate with meticulous soft tissue dissection to protect the axillary nerve. Surgical outcomes were evaluated by the American Shoulder and Elbow Surgeons (ASES) and visual analogue scale (VAS) scores, radiological imaging, and clinical examination. Fixation failure on radiographs was defined as a >$5^{\circ}$ loss of neck shaft angle (NSA) compared to that on an immediate postoperative radiograph. Avascular necrosis (AVN) of the humeral head was also evaluated. Results: In all cases, complete union was achieved. The ASES and VAS scores were improved to $85.4{\pm}2.1$ and $3.2{\pm}1.3$, respectively. Twelve patients (75.0%) had greater than a $5^{\circ}$ change in NSA; the average NSA change was $3.8^{\circ}$. Five patients (31.3%) had unsatisfactory ranges of motion exhibiting a <$100^{\circ}$ active forward flexion. No axillary nerve injuries or AVN were observed at the last follow-up. One patient was converted to reverse total arthroplasty due to severe pain and functional deficit. Conclusions: Minimally invasive fixation via a locking compression plate and an endosteal fibula strut allograft in Neer classification 3-or 4-part fractures with severe osteoporosis in elderly patients can achieve good clinical results.