• 제목/요약/키워드: Failure in the continuity

검색결과 65건 처리시간 0.026초

Service Block Based Resource Allocation Scheme for Macrocell-Femtocell Networks

  • Lee, Jong-Chan;Lee, Moon-Ho
    • 한국컴퓨터정보학회논문지
    • /
    • 제20권6호
    • /
    • pp.29-35
    • /
    • 2015
  • The heterogeneous LTE (Long Term Evolution)-Advanced networks comprising a macrocell and femtocells can provide an efficient solution not only to extend macrocell coverage but also to deal with packet traffics increasing explosively within macrocells. An efficient resource management scheme is necessary to maintain the QoS (Quality of Service) of mobile multimedia services because the LTE-Advanced system should support not only voice but also mobile applications such as data, image and video. This paper proposes a resource management scheme to guarantee QoS continuity of multimedia services and to maximize the resource utilization in OFDMA (Orthogonal Frequency Division Multiple Access) based LTE-Advanced systems. This scheme divides the resources into several service blocks and allocates those resources based on the competition between macrocell and femtocell. Simulation results show that it provides better performances than the conventional one in respect of handover failure rate and blocking rate.

클라우드 도입이 서비스 연속성에 미치는 영향에 관한 사례 분석 - 장애 중심으로 (A Case Analysis on the Effects of Cloud Adoption on Service Continuity - Focusing on Failures)

  • 허지용;윤준희;한은경
    • 한국인터넷방송통신학회논문지
    • /
    • 제23권4호
    • /
    • pp.121-126
    • /
    • 2023
  • 최근 인공지능, 빅데이터, IOT 등 IT 기술에 대한 서비스 활용도가 높아짐에 따라 방대한 데이터와 이를 처리하는 IT 인프라 자원의 효율적인 관리를 위해 클라우드 컴퓨팅을 도입하여 인프라 비용을 효율화하면서 안정적이고 신뢰성 있는 정보서비스 제공을 위한 노력이 계속되고 있다. 본 논문은 전체 1,750여개의 클라우드 시스템을 운영중인 기업의 클라우드 시스템에서 전국 360개 지점 426개 시스템을 대상으로 클라우드 도입 전과 도입후의 운영결과를 시스템 장애 관점에서 비교분석 하였으며, 분석 결과 장애건수, 장애유형, 서비스 중단 시간 등을 종합할 때 클라우드 도입이 서비스 연속성을 확보하는데 유의미한 결과를 얻었다. 이 결과를 통해 클라우드 도입으로 서비스 연속성 확보를 기대하는 기업에게 의미 있는 시사점을 제공 할 것으로 기대한다.

네트워크 중단 최소화를 위한 On-Box 컨테이너 기반 스위치 설정 자동화 기술 (On-box Container-based Switch Configuration Automation Technology to Minimize Network Interruption)

  • 유경환;김태홍
    • 대한임베디드공학회논문지
    • /
    • 제19권3호
    • /
    • pp.141-149
    • /
    • 2024
  • This paper proposes a configuration automation technique to minimize service interruption time in the event of a corporate network access layer switch failure. The automation is achieved without the need for a separate external system, as the network setting information is stored in a container inside the switch, enabling rapid recovery without requiring separate storage. This approach ensures the continuity of network services and demonstrates the efficiency of configuration automation. The proposed technique improves corporate network stability by providing a quick response in the event of a failure.

Soil and ribbed concrete slab interface modeling using large shear box and 3D FEM

  • Qian, Jian-Gu;Gao, Qian;Xue, Jian-feng;Chen, Hong-Wei;Huang, Mao-Song
    • Geomechanics and Engineering
    • /
    • 제12권2호
    • /
    • pp.295-312
    • /
    • 2017
  • Cast in situ and grouted concrete helical piles with 150-200 mm diameter half cylindrical ribs have become an economical and effective choice in Shanghai, China for uplift piles in deep soft soils. Though this type of pile has been successful used in practice, the reinforcing mechanism and the contribution of the ribs to the total resistance is not clear, and there is no clear guideline for the design of such piles. To study the inclusion of ribs to the contribution of shear resistance, the shear behaviour between silty sand and concrete slabs with parallel ribs at different spacing and angles were tested in a large direct shear box ($600mm{\times}400mm{\times}200mm$). The front panels of the shear box are detachable to observe the soil deformation after the test. The tests were modelled with three-dimensional finite element method in ABAQUS. It was found that, passive zones can be developed ahead of the ribs to form undulated failure surfaces. The shear resistance and failure mode are affected by the ratio of rib spacing to rib diameter. Based on the shape and continuity of the failure zones at the interface, the failure modes at the interface can be classified as "punching", "local" or "general" shear failure respectively. With the inclusion of the ribs, the pull out resistance can increase up to 17%. The optimum rib spacing to rib diameter ratio was found to be around 7 based on the observed experimental results and the numerical modelling.

동맥간의 외과적 치료 (Surgical treatment of Truncus Arteriosus)

  • 전태국
    • Journal of Chest Surgery
    • /
    • 제24권2호
    • /
    • pp.143-152
    • /
    • 1991
  • From 1983, until June, 1990, 10 patients with various type of truncus arteriosus underwent total surgical correction including Rastelli procedure at Seoul National University Hospital. The age at operation ranged from 1 month to 9 years [mean 2.1 years]. Six patients had truncus type I, 3 patients had truncus type II, and one patients had truncus type IIIc. Right ventricular pulmonary artery continuity was established with a porcine valved conduit in 6 patients, mechanical valved conduit in 1 patient, and bovine pericardial conduit in 3 patients. The postoperative right ventricular /left ventricular pressure ratio ranged from 0.4 to 0.71 [mean 0.51${\pm}$0.14]. The lung histology revealed grade II pulmonary obstructive disease even at 4 month of age. Five patients were dead in hospital [50%], and they were less than 2 year of age. One patient, who had severs congestive heart failure preoperatively, died of low output syndrome and the other died of low output syndrome with postoperative bleeding. There were three death, because of a pulmonary hypertensive crisis that might have been prevented. Two of the five survivors had conduit failure over a mean follow up of 42 months [range 1 to 78 months]. Obstructed conduit was removed and a new conduit constructed using the conduit bed as the posterior wall and the patch of bovine pericardium and Dacron as patch the roof of the conduit. One patient died of acute cardiac failure during the operation. Although results in infants less than 2 years old have not been good, current improvement of intra-and postoperative care suggested that prompt repair is indicated for infants with truncus arteriosus.

  • PDF

이동 멀티미디어 서비스의 연속성 보장을 위한 핸드오버 방법 (A Handover Method for Service Continuity of Mobile Multimedia)

  • 이종찬;이문호
    • 한국통신학회논문지
    • /
    • 제32권7A호
    • /
    • pp.770-777
    • /
    • 2007
  • 차세대 이동 통신망에서는 광대역의 멀티미디어 서비스를 요구하는 다수의 사용자를 수용하기 위해 마이크로-셀 또는 피코-셀 구조를 채택하므로 핸드오버가 빈번히 발생한다. 또한 핸드오버 처리에 허용될 수 있는 시간이 단말기의 고속 이동에 의해 감소됨으로써 서비스 절단 가능성이 높아지게 되어 매우 짧은 시간의 서비스 중단으로도 치명적인 영향을 받을 수 있다. 더욱이 패킷의 손실을 보상하기 위한 재전송으로 인해 시스템 성능의 추가적인 저하를 초래한다. 본 논문에서는 차세대 이동 멀티미디어 통신망에서 단말기의 핸드오버 시에 기지국 기반 위치 정보와 GPS 위치 정보를 복합적으로 이용하여 멀티미디어 서비스의 지속성을 증대시키기 위한 방안을 제안한다. 제안된 방법의 성능을 평가하기 위해 핸드오버 실패율과 패킷 손실률을 시뮬레이션에 의해 분석하였다.

취성파괴수준과 파괴개시시점에 관한 진삼축 모형실험연구 (True Triaxial Physical Model Experiment on Brittle Failure Grade and Failure Initiation Stress)

  • 천대성;박찬;박철환;전석원
    • 터널과지하공간
    • /
    • 제17권2호
    • /
    • pp.128-138
    • /
    • 2007
  • 상대적으로 저심도에 건설되는 암반구조물의 경우 단층이나 절리 등 암반 내 존재하는 불연속면이 굴착 후 생성된 경계면과의 교차에 의해 구조적인 형태의 파괴가 지배적으로 발생하나, 고심도에 건설되는 경우 높은 현지응력과 굴착에 따른 유도응력으로 인해 공동 경계면에서 스폴링이나 슬래빙과 같은 취성파괴가 발생할 수 있다. 취성파괴는 암반구조물의 안정성을 약화시키는 주된 원인으로, 고심도 영역에서 암반구조물의 안정성을 확보하기 위하여 응력조건에 따라 발생하는 취성파괴의 개시시점, 파괴수준 및 파괴범위 등과 같은 파괴특성이 규명되어야 한다. 본 연구에서는 고심도의 암반구조물에서 발생할 수 있는 취성파괴의 파괴수준 및 개시시점과 재하응력사이의 관계를 정량적으로 평가하고자 진삼축 응력조건을 구현할 수 있는 모형실험장치를 설계, 제작하여 여러 응력조건에서 모형실험을 수행하였다. 공동주변에서 발생한 파괴수준을 육안관찰과 미소파괴음 발생양상에 의해 3단계로 구분하고, 진삼축 응력조건에 따라 제시하였다. 그 결과 파괴수준은 공동단면에 작용하는 재하응력$(S_v,\;S_{H2})$ 뿐 아니라 공동 축에 평행한 재하응력 $S_{H1}$에 영향을 받으며, $S_{H1}$$S_{H2}$의 크기가 증가할수록 동일한 $S_v$에서 파괴수준은 감소하였다. 파괴개시점 역시 $S_{H1}$$S_{H2}$의 증가에 따라 파괴개시를 위한 응력수준은 증가하였으며, 다중회귀분석을 통해 파괴개시시점과 진삼축 응력조건의 관계식을 도출하였다.

OFDMA 시스템에서 서비스 연속성 지원 방안 (Supporting Service Continuity in OFDMA Systems)

  • 이종찬;박상준
    • 한국산학기술학회논문지
    • /
    • 제14권2호
    • /
    • pp.850-857
    • /
    • 2013
  • 본 논문의 목적은 다중 셀 OFDMA 시스템에서 효율적인 부채널 할당에 근거하여 서비스 연속성을 제공하는 것이다. 특히 지연 및 손실에 의해 서비스 지속성에 악영향을 야기할 가능성이 있으므로 다양한 이동 멀티미디어 서비스의 QoS 요구사항을 유지하기 위하여 핸드오버를 위한 자원 관리 방안이 필요하다. 따라서 본 연구에서는 두 개의 부채널 할당 방법을 제안한다. 우선, 동일 부채널 간섭 원리를 사용하여 주파수 재사용 기법을 확장함으로서 간섭 채널의 중첩 할당 방식이 제안되고, 둘째로 핸드오버 요구를 위하여, 이동 멀티미디어의 서로 다른 서비스 특성과 서비스의 질에 따라서 할당된 채널의 수를 조정하는 새로운 부채널 할당 방법을 제안한다. 시뮬레이션을 통하여, 제안된 방법이 데이터 처리량을 20%까지 증가시키며, 핸드오버 실패율을 25% 정도 감소시킬 수 있음을 보인다.

임무컴퓨터를 위한 고가용 시스템의 구현 및 성능분석 (Implementation and Performance Analysis of High-availability System for Mission Computer)

  • 정재엽;박성종;임재석;이철훈
    • 한국콘텐츠학회논문지
    • /
    • 제8권8호
    • /
    • pp.47-56
    • /
    • 2008
  • 임무컴퓨터는 항공전자시스템에서 임무 수행에 필요한 각종 전술데이터 처리, 영상처리, 항법정보의 관리 및 융합 등의 매우 중요한 기능을 수행한다. 이러한 중요 시스템이 단일시스템으로 구성되면, 여러 가지 SPOF(Single Point Of Failure) 요소의 고장으로 인해 전체 시스템의 고장으로 이어질 수 있다. 이는 서비스 중단으로 인한 임무의 실패뿐만 아니라 조종사의 생명까지도 위협할 수 있다. 본 논문에서는 단일 시스템의 이중화를 통해 SPOF 요소를 제거하고, 이를 운영하기 위한 방안으로 리눅스 기반의 Heartbeat, Fake, DRBD(Distributed Replicated Block Device), Bonding 등의 기법을 이용하여 고가용 시스템을 구현하였다. 또한, 구현한 고가용 시스템에서 빠른 고장 탐지를 위한 FDT(Fault Detection Time)와 고장 발생 시 임무 연속성을 위해 중요한 요소일 MTTR(Mean Time To Repair)의 평균값을 측정하고, 그에 따른 성능분석 결과를 제시한다.

Modeling wind load paths and sharing in a wood-frame building

  • He, Jing;Pan, Fang;Cai, C.S.
    • Wind and Structures
    • /
    • 제29권3호
    • /
    • pp.177-194
    • /
    • 2019
  • While establishing adequate load paths in the light-frame wood structures is critical to maintain the overall structural integrity and avoid significant damage under extreme wind events, the understanding of the load paths is limited by the high redundant nature of this building type. The objective of the current study is to evaluate the system effects and investigate the load paths in the wood structures especially the older buildings for a better performance assessment of the existing building stock under high winds, which will provide guidance for building constructions in the future. This is done by developing building models with configurations that are suspicious to induce failure per post damage reconnaissance. The effect of each configuration to the structural integrity is evaluated by the first failure wind speed, amajor indicator beyond the linear to the nonlinear range. A 3D finite-element (FE) building model is adopted as a control case that is modeled using a validated methodology in a highly-detailed fashion where the nonlinearity of connections is explicitly simulated. This model is then altered systematically to analyze the effects of configuration variations in the model such as the gable end sheathing continuity and the gable end truss stiffness, etc. The resolution of the wind loads from scaled wind tunnel tests is also discussed by comparing the effects to wind loads derived from large-scale wind tests.