• Title/Summary/Keyword: Failure Effect

Search Result 3,823, Processing Time 0.033 seconds

A study on nonlinear analysis and confinement effect of reinforced concrete filled steel tubular column

  • Xiamuxi, Alifujiang;Hasegawa, Akira;Yu, Jiang
    • Structural Engineering and Mechanics
    • /
    • v.56 no.5
    • /
    • pp.727-743
    • /
    • 2015
  • According to former studies, the mechanical properties of reinforced concrete filled tubular steel (RCFT) columns differed greatly from that of concrete filled steel tubular (CFT) columns because of interaction of inserted reinforcement in RCFT. Employing an experiment-based verification policy, a general FE nonlinear analysis model was developed to analyze the mechanical behavior and failure mechanism of RCFT columns under uniaxial compression. The reasonable stress-strain relationships were suggested for confined concrete, reinforcements and steel tube in the model. The mechanism for shear failure of concrete core was found out in the numerical simulation, and a none-conventional method and equation for evaluating the confinement effect of RCFT were proposed.

Effect of pre-stressed cable on pre-stressed mega-braced steel frame

  • Tang, Baijian;Zhang, Fuxing;Wang, Yi;Wang, Fei
    • Structural Engineering and Mechanics
    • /
    • v.59 no.2
    • /
    • pp.327-341
    • /
    • 2016
  • This study addresses the effect of pre-stressed cables on a pre-stressed mega-braced steel frame through employing static analysis and pushover analysis. The performances of a pre-stressed mega-braced steel frame and a pure steel frame without mega-braces are compared in terms of base shear, ductility, and failure mode. The influence of the cable parameters is also analyzed. Numerical results show that cable braces can effectively improve the lateral stiffness of a pure frame. However, it reduces structural ductility and degenerates structural pre-failure lateral stiffness greatly. Furthermore, it is found that 20% fluctuation in the cable pretension has little effect on structural ultimate bearing capacity and lateral stiffness. As comparison, 20% fluctuation in the cable diameter has much greater impact.

Examining the Impact of Co-branding Service Failures on Consumer Evaluations

  • Lee, Chia-Lin
    • Asia Marketing Journal
    • /
    • v.19 no.3
    • /
    • pp.19-44
    • /
    • 2017
  • Researchers do not fully understand consumers' responses to negative co-branding events; thus, they report inconsistent evidence regarding the negative impact on the partnering brands. Our research bridges a gap in this research stream, and answers an important question: When a service failure occurs, could the two different models of consumers' brand schema change affect their negative perception of each brand partner? By using a theoretical and mathematical modeling approach, we offer two propositions. The first proposition shows that, under consumers' book-keeping cognitive process, the negative spillover effect occurs for both brands. The second proposition argues that, when the sub-typing model is assumed, it is possible that one brand suffers while the other escapes the blame for the failure. To our knowledge, this is one of the first few studies to identify circumstances in which a negative spillover effect may or may not occur to brand partners in co-branding service failures.

The effect of Internal control over financial reporting on probability of firm failure (내부회계관리제도가 기업실패가능성에 미치는 영향)

  • Kim, Hyun-Jin
    • Management & Information Systems Review
    • /
    • v.33 no.1
    • /
    • pp.173-190
    • /
    • 2014
  • According to COSO(2013) "Internal control is a process that is designed to provide reasonable assurance that a firm can achieve its objectives, where differing aspects of internal control can be partitioned into operating objectives, reporting objectives, and compliance objectives." Internal control over financial reporting(ICFR) is focus on reporting objectives and includes that provide reasonable assurance regarding prevention or timely detection of unauthorized acquisition, use or disposition of the company's assets that could have a material effect on the financial statements. Thus, firms with weak ICFR have negative a effect on Firm value because those firms are great likelihood of misappropriation and inefficiency decision. In this regard, this study investigates the association of ICFR with the likelihood of firm failure. Specially, I measure the characteristic of ICFR as disclosures of material weaknesses and operating personnel of ICFR. I identify the likelihood of firm failure as going-concern opinion issued in audit report. As result, I find that a higher probability of firm failure is positively associated with the material weakness in ICFR also I find that a higher probability of firm failure is negatively associated with experience and qualified CPA of personnel in ICFR.

  • PDF

The Effect of Juglandis Semen Aquacupuncture on Diuresis of Rat in Glycerol-Induced Acute Renal Failure (호도약침(胡桃藥鍼)이 Glycerol로 유발(誘發)된 급성신부전(急性腎不全) 백서(白鼠)의 이뇨(利尿)에 미치는 영향(影響))

  • Jung, Hyun-Chol;Song, Choon-Ho
    • Journal of Acupuncture Research
    • /
    • v.17 no.1
    • /
    • pp.107-117
    • /
    • 2000
  • This study was undertaken to determine if Juglandis Semen Aquacupuncture(Ja) has a protective effect against glycerol-induced acute renal failure in rats. Rats were dehydrated for 24hr and then injected with $5m{\ell}/kg$ of 50% glycerol, one-half of dose in each hindlimb muscle. In experiments for Ja effect, rats received $0.1m{\ell}$ of Ja extraction in both sides of corresponding $Sh{\grave{e}}ns{\bar{u}}$($BL_{23}$) of human body and non-acupuncture points(the root of tail) for 3 days after injection of glycerol. The experimental group were divided into the Normal group, the Control group, the Ja to $Sh{\grave{e}}ns{\bar{u}}$($BL_{23}$) group(Ja-AS), the Ja to non-acupuncture points group(Ja-AN). There were significant decrease of Urine vollume, total protein and phosphate level in Ja-AS as compared with the control group. There were not any significant change of Urine creatinine in Ja-AS as compared with the control group. There were significant decrease of Unine glucose in Ja-AS, Ja-AN as compared with the control group. This suggests that Ja-AS could be used in prevention and treatment of acute renal failure. However, the precise mechanisms of Ja protection remain to be determined.

  • PDF

The Effect of Paljeong-San Pharmacopuncture Treatment on Glycerol-Induced Acute Renal Failure in Rats (팔정산(八正散) 약침(藥鍼)이 글리세롤로 유발된 흰쥐의 급성 신부전에 미치는 영향)

  • Lee, So-Young;Kim, Min-Ho;Yun, Yeo-Choong;Cho, Su-In;Lim, Se-Hyun
    • Journal of Haehwa Medicine
    • /
    • v.21 no.1
    • /
    • pp.163-174
    • /
    • 2012
  • Objective: The primary objective this study was to evaluate the effect of Paljeong-san (PJS) pharmacopuncture treatment on against the glycerol-induced acute renal failure in rats. Methods: Glycerol injection decreased GFR (glomerular filtration rate) and increased urine volume, serum creatinine, BUN level, urine albumine secretion and fractional excretion of Na+, K+. PJS was selected in the basis of invigorating kidney which can eliminate pathogens. Rats were treated with PJS pharmacopuncture on Shin-shu (BL23) and Chon-chu (ST25) point for 3 days, followed by 50% concentration of glycerol injection ($5m{\ell}/kg$ body weight). Results: After the 3 days treatment period, Paljeong-san (PJS) pharmacopuncture treatment improved renal function. In addition, Glycerol injection increased lipid peroxidation, and decreased Na-K-ATPase in renal cortex and which were prevented by PJS treatment. Conclusion: This study suggests that Paljeong-san (PJS) pharmacopuncture treatment show favorable effect on glycerol-induced acute renal failure in rats.

Case Study of Patient with Pleural Effusion Due to Congestive Heart Failure (울혈성 심부전으로 인한 흉막삼출에 대한 한방치험 1례)

  • Park, Jong Joo;Ko, Seung Woo;Kong, Kyung Kwan;Go, Ho Yeon;Moon, Ju Ho
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.27 no.4
    • /
    • pp.460-464
    • /
    • 2013
  • The purpose of this case was to report the effect of Korean medical treatment for patient with pleural effusion due to congestive heart failure. The patient was treated with herbal medicine(Cheongsingeonbi-tang) and acupuncture. The effect of treatment was evaluated by chest X-ray, New York Heart Association(NYHA) functional classification, and Hugh-Jones classification. After 3 weeks of treatment, the amount of pleural effusion was decreased and NYHA class, Hugh-Jones grade were improved. NYHA functional classification improved class III to II and Hugh-Jones classification changed grade IV to II. This result suggests that herbal medicine(Cheongsingeonbi-tang) and acupuncture treatment might have an effect on patient with pleural effusion due to congestive heart failure.

Beneficial Effect of Paljeong-san Pharmacopuncture Treatment Combined with Peritoneal Injection on Glycerol-Induced Acute Renal Failure in Rabbits (팔정산(八正散) 약침(藥鍼) 및 복강(腹腔) 주입 병용 시술이 글리세롤로 유발된 토끼의 급성 신부전에 미치는 영향)

  • Lim, Chi-Yeon;Kim, Min-Ho;Lee, Geum-San;Kim, Hyung-Woo;Kim, Bu-Yeo;Yun, Yeo-Choong;Cho, Su-In
    • Journal of Pharmacopuncture
    • /
    • v.13 no.3
    • /
    • pp.73-80
    • /
    • 2010
  • Purpose: The present study was carried out to determine if Paljeong-san extract (PJS) treatment exerts beneficial effect against the glycerol-induced acute renal failure in rabbits. Material and Method: PJS was selected in the basis of invigorating kidney which can eliminate pathogens. Rabbits were treated with PJS pharmacopuncture on Shin-shu ($BL_{23}$) point for 5 days right after the injection of 50% concentration of glycerol ($5m{\ell}/kg$ body weight). Results and Conclusions: Glycerol injection caused an increase in serum creatinine and BUN level and urine glucose secretion, which were accompanied by a reduction in GFR. PJS Pharmacopuncture treatment combined with peritoneal injection showed beneficial effect on glycerol-induced acute renal failure by inhibition of serum creatinine increase and GFR decrease.

Static test on failure process of tubular T-joints with initial fatigue crack

  • Wang, Yamin;Shao, Yongbo;Song, Shengzhi;Yang, Dongping
    • Steel and Composite Structures
    • /
    • v.24 no.5
    • /
    • pp.615-633
    • /
    • 2017
  • Fatigue crack initiated in welded tubular joints due to cyclic loading may produce harmful effect on the integrity of the tubular structures. To study such effect, both fatigue and static tests on nine circular tubular T-joint specimens made of carbon steel materials were carried out. The specimens were subjected to tensile loading in both fatigue and static tests. The load-displacement relation, the crack propagation and the failure mode of the specimens are all analyzed. The deterioration of the static strength of the cracked T-joints is also investigated and evaluated through an area reduction factor. Experimental results indicate that the static strength of a tubular T-joint with a surface crack seems to decrease slightly while a through crack has relatively remarkable effect on the reduction of the static strength. Additionally, experimental results also show that the toughness of the materials and the geometry of the specimens play an important role on the failure process of cracked tubular T-joints.

The Effect of Fault Failure with Time Difference on the Runup Height of East Coast of Korea (시간차를 지닌 단층파괴 활동이 동해안 처오름 높이에 미치는 영향)

  • Jung, Taehwa;Son, Sangyoung
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.32 no.4
    • /
    • pp.223-229
    • /
    • 2020
  • The fault failure process with time difference affects the initial generation of waveforms of tsunamis, which consequently changes the runup height on the coast. To examine the effect of time difference in fault failure process on the runup height, a numerical simulation was conducted assuming a number of virtual subsea earthquakes in the west coast of Japan. Results revealed that maximum runup heights along the east coast of Korea were minimal when the subfaults were aligned parallel with the shoreline. Meanwhile, if they were located perpendicular to the shoreline, the superposition effect of the initial surface by each subfault was noticeable, resulting in an increase in maximum runup height on the coast.