• 제목/요약/키워드: Failure Code

검색결과 639건 처리시간 0.024초

Effects of Pre-Strains on Failure Assessment Analysis to API 5L X65 Pipeline

  • Baek, Jong-Hyun;Kim, Young-Pyo;Kim, Woo-Sik;Seok, Chang-Sung
    • 비파괴검사학회지
    • /
    • 제29권3호
    • /
    • pp.219-223
    • /
    • 2009
  • This paper prescribed the structural integrity of the API 5L X65 pipeline subjected to tensile pre-strain. The effects of pre-strain on the mechanical properties of API 5L X65 pipe were substantially investigated through a variety of the experimental procedures. Axial tensile pre-strain of 1.5, 5 and 10% was applied to plate-type tensile specimens cut from the pipe body prior to mechanical testing. Tensile test revealed that yield strength and tensile strength were increased with increasing tensile pre-strain. The increasing rate of the yield strength owing to the pre-strain is greater than that of the tensile strength. However, the pre-strain up to 5% had a little effect on the decreasing of the fracture toughness. The structural integrity of the API 5L X65 pipeline subjected to large plastic deformation was evaluated through the fitness-for service code.

항공기 외장 탑재장비의 음향소음 내구성 검증 (Acoustic Noise Durability Verification for a Jet Aircraft External Store)

  • 이종학;이유경;강영식;최지호;강동석
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.42-47
    • /
    • 2014
  • In this paper, fatigue life analysis of each structure was performed through theoretical analysis method at design stage in order to verify the success or failure of the store's acoustic noise durability according to the Method 515.5 standard of MIL-STD-810F. In addition, experimental analysis was carried out through the ground and flight test by manufacturing the measuring store, and verification of the sound durability was completed through the flight test after manufacture of the actual store. Furthermore, the commercial FEM code through the PSD calculation method applying measured SPL enables verify the durability of new store components development for the future.

  • PDF

Runtime Software Monitoring Based on Binary Code Translation for Real-Time Software

  • Choi, Kiho;Kim, Seongseop;Park, Daejin;Cho, Jeonghun
    • Journal of Information Processing Systems
    • /
    • 제15권6호
    • /
    • pp.1462-1471
    • /
    • 2019
  • Real-time embedded systems have become pervasive in general industry. They also began to be applied in such domains as avionics, automotive, aerospace, healthcare, and industrial Internet. However, the system failure of such domains could result in catastrophic consequences. Runtime software testing is required in such domains that demands very high accuracy. Traditional runtime software testing based on handwork is very inefficient and time consuming. Hence, test automation methodologies in runtime is demanding. In this paper, we introduce a software testing system that translates a real-time software into a monitorable real-time software. The monitorable real-time software means the software provides the monitoring information in runtime. The monitoring target are time constraints of the input real-time software. We anticipate that our system lessens the burden of runtime software testing.

비선형 유한요소해석을 이용한 철근콘크리트 깊은 보의 내하력 평가 (Load Capacity Assesment of Reinforced Concrete Deep Beams using Nonlinear Finite Element Analysis)

  • 천주현;김태훈;이상철;신현목
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(I)
    • /
    • pp.147-150
    • /
    • 2005
  • This paper presents a method for the load capacity assesment of reinforcement concrete deep beams using nonlinear finite element analysis. A computer program, named RCAHEST (Reinforced Concrete Analysis in Higher Evaluation System Technology), for the analysis of reinforced concrete structures was used. From the results, determine the reliability index for the failure base from the Euro Code. Then, calculated additional reduction coefficient to satisfy the goals from the reliability analysis. The proposed numerical method for the load capacity assesment of reinforced concrete deep beams is verified by comparison with the others methods

  • PDF

장지간 PSC 바닥판의 정적펀칭강도 (Punching Strength of Long-Span PSC Deck Slabs)

  • 황훈희;조창빈;윤혜진;김성태
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(I)
    • /
    • pp.467-470
    • /
    • 2005
  • This study was performed to evaluate the static strength of long-span PSC deck slabs. In the previous study, the minimum thickness of PSC deck slabs in the composite two-girder bridge was proposed. To examine the structural behavior and safety of the PSC deck slabs designed in accordance with the proposed minimum thickness, 1/3 scaled PSC deck slabs in the composite two-girder bridge were tested under the static loading. The test results were compared with the predicted values proposed by the code and Matsui. Test results showed ultimate static strength of the PSC deck slabs designed in accordance with the proposed minimum thickness have enough margin of safety. The static failure mode of each test specimen was punching shear mode.

  • PDF

Using radial basis function neural networks to model torsional strength of reinforced concrete beams

  • Tang, Chao-Wei
    • Computers and Concrete
    • /
    • 제3권5호
    • /
    • pp.335-355
    • /
    • 2006
  • The application of radial basis function neural networks (RBFN) to predict the ultimate torsional strength of reinforced concrete (RC) beams is explored in this study. A database on torsional failure of RC beams with rectangular section subjected to pure torsion was retrieved from past experiments in the literature; several RBFN models are sequentially built, trained and tested. Then the ultimate torsional strength of each beam is determined from the developed RBFN models. In addition, the predictions of the RBFN models are also compared with those obtained using the ACI 318 Code equations. The study shows that the RBFN models give reasonable predictions of the ultimate torsional strength of RC beams. Moreover, the results also show that the RBFN models provide better accuracy than the existing ACI 318 equations for torsion, both in terms of root-mean-square error and coefficients of determination.

Experimental investigation of infilled r/c frames with eccentric openings

  • Kakaletsis, D.;Karayannis, C.
    • Structural Engineering and Mechanics
    • /
    • 제26권3호
    • /
    • pp.231-250
    • /
    • 2007
  • The influence of masonry infills with eccentric openings on the seismic performance of reinforced concrete (r/c) frames that were designed in accordance with current code provisions are investigated. Eight 1/3-scale, single-story, single-bay frame specimens were tested under cyclic horizontal loading up to a drift level of 4%. In all examined cases the shear strength of columns was higher than the cracking shear strength of solid infill. The parameters investigated include the shape and the location of the opening. Assessment of the behavior of the frames is also attempted, based on the observed failure modes, strength, stiffness, ductility, energy dissipation capacity and degradation from cycling loading. Based on these results there can be deduced that masonry infills with eccentrically located openings has been proven to be beneficial to the seismic capacity of the bare r/c frames in terms of strength, stiffness, ductility and energy dissipation. The location of the opening must be as near to the edge of the infill as possible in order to provide an improvement in the performance of the infilled frame.

여분을 갖는 통신시스템에서의 자기검사특성 향상에 관한 연구 (A Study on Enhanced Self-Checking Characteristics in Redundant Communication System)

  • 신덕호;김현기;이재훈;이창훈;이기서
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2000년도 춘계학술대회 논문집
    • /
    • pp.352-359
    • /
    • 2000
  • In this paper, the method is used that each system isolates the part in which faults are occurred in case of fault occurrence since total system is designed in the type of hot standby sparing system construction and self-checking circuit in each system is attached to the memory being of the high failure rate in common communication system. Thus reliability and availability in system are improved. In this thesis, self-checking circuit was designed using 2 out of 6 code and didn't have any effect to the system operation. For the purpose of verification, each system attached with self-checking circuit was simulated through fault injection arid the continuity of each system in hot standby sparing system was tested in case that the system was switched when faults in the system were occurred.

  • PDF

유연성 원리를 이용한 철도변 사면보강시스템 적용사레연구 (Flexible Concept Applicable to Railway)

  • 최우경;최승일;노병돈;김형민
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 추계학술대회 논문집
    • /
    • pp.203-210
    • /
    • 2005
  • Rockey slopes adjacent to railways are disclosed from severe weathering and hazard of failure of themselves. Consequently it causes directly rockfall or landsliding on the railway. Conventional solutions-rigid system like rocksheds, shotcrete, retaining walls, etc to these causes are limited to protect train, rail, our properties and lives from the harmful attack - rockfall. debris flow and sliding. Flexible concept for solutions with passive and active type method based on Euro Code 7 capable of high energy absorption and light materials are rapidly replacing the rigid systems with natural friendly, early installation, cost and time saving and reducing danger in works all over the world.

  • PDF

Improved earthquake resistant design of torsionally stiff asymmetric steel buildings

  • Kyrkos, M.T.;Anagnostopoulos, S.A.
    • Earthquakes and Structures
    • /
    • 제2권2호
    • /
    • pp.127-147
    • /
    • 2011
  • In a companion paper as well as in earlier publications, it has been shown that in asymmetric frame buildings, designed in accordance with modern codes and subjected to strong earthquake excitations, the ductility demands at the so called "flexible" edges are consistently and substantially higher than the ductility demands at the "stiff" edges of the building. In some cases the differences in the computed ductility factors between elements at the two opposite building edges exceeded 100%. Similar findings have also been reported for code designed reinforced concrete buildings. This is an undesirable behavior as it indicates no good use of material and the possibility for overload of the "flexible" edge members with a consequent potential for premature failure. In the present paper, a design modification will be introduced that can alleviate the problem and lead to a more uniform distribution of ductility demands in the elements of all building edges. The presented results are based on the steel frames detailed in the companion paper. This investigation is another step towards more rational design of non-symmetric steel buildings.