• Title/Summary/Keyword: Facility maintenance

Search Result 872, Processing Time 0.026 seconds

Dynamic Characteristic Analysis of Water-Turbine Generator Control System of Sihwa Tidal Power Plant (시화조력발전소 수차발전기 제어시스템의 동적 특성 해석)

  • Ahn, Sang-Ji;Ban, Yu-Hyeon;Park, Chul-Won
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.61 no.4
    • /
    • pp.180-185
    • /
    • 2012
  • Tidal power is one of new and renewable energy sources. The seawater is stored inside a tidal embankment built at the mouth of a river or bay, where tides ebb and flow. The water turbine-generators produce power by exploiting the gap in the water level between the water outside and inside the embankment. Tidal power plant is a large plant that is installed on the sea. And then, the facility's operations and a separate control system for monitoring and maintenance is required. However, this plant predictive control of building systems and technologies have been avoided the transfer of technology from advanced global companies. Accordingly, the control system for core technology development and localization is urgently needed. This paper presents modeling and simulation using by PSS/E about generator, governor, exciter, and power system stabilizer for control system in Sihwa tidal power plant to improve the efficiency and develope of core technology. And the dynamic characteristics of governor and exciter were analyzed.

The Study on Evaluation Basis of Management Strategy in Public Buildings (공공건축물의 합리적인 운영평가기준 설정 방향에 관한 연구)

  • Lee, Sang-Beom;Noh, Byung-Ok
    • Journal of the Korea Institute of Building Construction
    • /
    • v.9 no.2
    • /
    • pp.69-76
    • /
    • 2009
  • Recently, the twenty-first century is called "the age of localization and regionalization" in Korea. So, local government should need to keep balance between the existing administrative management and new management strategies based on CEO's mind in order to deal with the situation of such that(the age of localization and regionalization) and improve efficiency of public service. In addition, they build public buildings after that they should operate and maintain them regularly. However, Korea local governments have tried to run many projects to expand insufficient local finance that was only for profit oriented public projects without considering management. Therefore, this paper is a basic study to establish and suggest the reasonable operation plan for local government by examining and reviewing actual operation condition in the public buildings. With the evaluation method which is demanded from public construction management to introduce a civil management technique manages an investment mind standard and management basis of assessment, proposes 8 sides of financial affairs, real estate maintenance and facility management, achievement evaluation, environmental safe crisis management, judiciary and explanation responsibility with base.

A Study on the Characteristics of the Earth Heat Extraction Using Termosyphon (Termosyphon의 지열채열 성능에 관한 고찰)

  • Shin, H.J.;Seo, J.Y.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.5 no.3
    • /
    • pp.226-233
    • /
    • 1993
  • Thermosyphons are simple devices that can passively transport thermal energy over relatively large distance with little temperature degradation. Especially, the thermosyphon system requires no costly energy input and is completely maintenance free. These attributes permit the use of low grade thermal energy for thermal control of structures including the stabilization of highway foundations. This paper presents the experimental results of the snow melting system in which thermosyphon was utilized to ransfer the earth energy to the pavement to remove snow and ice. The test facility, three earth heated and one unheated test panels, is designed to investigate the variables associated with removing snow and ice from pavement surfaces. The results of these test show that the earth heated panel surface temperature is higher $2{\sim}6^{\circ}C$ than unheated panel when the ambient air temperature is $-7^{\circ}C$. The thermal performance of this earth source thermosyphon system for road heating showed that there was no snow on the heated test panels when the snowfall was 5cm average for the region.

  • PDF

A Study on the Musculoskeletal Disorders in Petrochemical Industry (석유화학산업의 근골격계질환 실태에 관한 연구)

  • Park, Jung-Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.8 no.3
    • /
    • pp.77-86
    • /
    • 2006
  • After conducting an investigation of a specific workplace, 372 labor workers, who are employed at a certain domestic petrochemical company valve operating and maintenance processing section, were personally questioned about specific work-related ailments. According to the results, 57% of workers who were working in the petrochemical industry have suffered from pain-related musculoskeletal disorders in, at least, more than 1 body part. Specifically, there are more than 28% of workers suffering from pain in more than two body parts. Among the total work population, 18.8 % of workers are assumed to have a high probability of being diagnosed with musculoskeletal disorder. Also, according to the RULA checklist which evaluates environmental improvement conditions of the workplace, 76.7% of workplaces among the inspected areas have high hazardous work factors that are related to musculoskeletal disorder and needs to be improved upon and observed right away or in the foreseeable future. The prior factor has a high correlation and pain rate which is due to an improper work posture. Originally, this improper work posture is caused mostly by ergonomically incorrect facility design. Furthermore, the structure of the workplace does not consider the worker's individual build.

Development and Implementation of Measures for Structural and Reliability Importance by Using Minimal Cut Sets and Minimal Path Sets (최소절단집합과 최소경로집합을 이용한 구조 및 신뢰성 중요도 척도의 개발 및 적용)

  • Choi, Sung-Woon
    • Journal of the Korea Safety Management & Science
    • /
    • v.14 no.1
    • /
    • pp.225-233
    • /
    • 2012
  • The research discusses interrelationship of structural and reliability importance measures which used in the probabilistic safety assessment. The most frequently used component importance measures, such as Birnbaum's Importance (BI), Risk Reduction (RR), Risk Reduction Worth (RRW), RA (Risk Achievement), Risk Achievement Worth (RAW), Fussel Vesely (FV) and Critically Importance (CI) can be derived from two structure importance measures that are developed based on the size and the number of Minimal Path Set (MPS) and Minimal Cut Set (MCS). In order to show an effectiveness of importance measures which is developed in this paper, the three representative functional structures, such as series-parallel, k out of n and bridge are used to compare with Birnbaum's Importance measure. In addition, the study presents the implementation examples of Total Productive Maintenance (TPM) metrics and alternating renewal process models with exponential distribution to calculate the availability and unavailability of component facility for improving system performances. System state structure functions in terms of component states can be converted into the system availability (unavailability) functions by substituting the component reliabilities (unavailabilities) for the component states. The applicable examples are presented in order to help the understanding of practitioners.

Life Cycle Cost Analysis of Primary Cooling System by Systematic Support Cost (각종지원금제도에 의한 냉열원시스템의 라이프 사이클 코스트 분석)

  • Kim, C.M.;Jung, S.S.;Choi, C.H.
    • Journal of the Korean Solar Energy Society
    • /
    • v.22 no.4
    • /
    • pp.97-106
    • /
    • 2002
  • The purpose of this study is to analyze the life cycle cost of primary cooling system by systematic support cost. Life Cycle Cost(LCC) is the process of making an economic assessment of an item, area, system, or facility by considering all significant costs of ownership over an economic life, expressed in terms of equivalent costs. The essence of life cycle costing is the analysis of equivalent costs of various alternative proposals. In order to select economical primary cooling system in early heat source plan stages, the research investigates cost items and cost characteristics during project process phases such as planning/design, construction, maintenance /management, and demolition/sell phases. The study also analyze the life cycle cost by capacity leading to suggest the most economical primary cooling system by systematic support cost.

A Study on the Proper Location of Ventilation Outlets and Inlets in the Germ Free Pigs' Room (무균돈사내 급배기구의 적정위치설정에 관한 연구)

  • Kwon, Soonjung;Son, Deok-Young;Choi, Yoon-Ho
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.14 no.4
    • /
    • pp.39-46
    • /
    • 2008
  • Construction and operation of Germ Free Pigs' facilities are very expensive because pigs' rooms and other major rooms of the facility require germfree environments. Especially, running the HVAC system of aseptic facilities requires a lot of expenses. However, proper location and efficient shape of outlets/inlets for the ventilation of the room can reduce the excessive running cost. In order to do that, this study proposes alternative location and shape of ventilation outlets/inlets to the existing design pattern in germfree pigs' room. The design condition of this study is the maintenance of adequate temperature(24$^{\circ}C$, $NH_3$concentration level(below 1.5 ppm), and air stream speed(below .25m/sec) in the pigs' room for the summer and the winter together. As the Software Program, FLUENT(Ver. 6.2) has been used for the analysis of proposed ventilation patterns. In conclusion, wall inlets and ceiling inlet/outlet are advisable in summer, wall inlets and ceiling outlets is advisable in winter. As far as the shape is concerned, diffuser type for the ceiling outlet is desirable.

  • PDF

A Case Study on Server Consolidation of Public Organizations: Concentrated on NDMS (공공기관의 서버통합 사례연구: NDMS를 중심으로)

  • Na, Kwan-Sik
    • Journal of Information Technology and Architecture
    • /
    • v.9 no.1
    • /
    • pp.67-78
    • /
    • 2012
  • Organizations have many physical servers in their departments such as application servers, web servers, database servers, mail servers, and so forth. The problem of server sprawl is common in information system centers of most profit and nonprofit organizations. Server sprawls are characterized by the use of dedicated servers for single applications. This server sprawl causes the problems such as the low resource utilization, the large space consumption, and the high management cost. Server consolidation is crucial to solve these problems by providing savings in hardware, software, maintenance, facility, and labor costs. This paper proposed a method to implement server consolidation for public organizations by the NDMS(National Disaster Management Systems) case study.

Improving efficiency through the hydrological observation equipment performance test center and program (수문관측설비 성능시험센터 구축 및 프로그램 개발을 통한 효율 향상 방안)

  • Hong, Sung-Taek;Shin, Gang-Wook
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.11
    • /
    • pp.2731-2738
    • /
    • 2015
  • The importance of disaster observation facilities and system are increasing around the world in order to predict and prevent water disasters, which cause serious damage to life and property. A performance test center was built to stabilize performance, compatibility, and reliability of devices, and to verify new S/W. The aim of this study is to make a guideline to build standard verifying system for hydrological observation devices by building the performance test center. In addition, efficiency of management and operation of hydrological devices can be enhanced through device analysis, maintenance, database building, and grade certificate publishment after the device test.

Fault Diagnosis Algorithm of an Air-conditioning System by using a Neural No-fault Model and a Dual Fuzzy Logic (신경망무고장모델과 이중퍼지로직을 사용한 냉방기 고장진단 알고리즘)

  • Han Do-Young;Jung Nam-Chul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.10
    • /
    • pp.791-799
    • /
    • 2006
  • The fault diagnosis technologies may be applied in order to decrease the energy consumption and the maintenance cost of an air-conditioning system. In this paper, a fault diagnosis algorithm was developed by using a neural no-fault model and a dual fuzzy logic. Five different faults, such as the compressor valve leakage, the liquid line blockage, the condenser fouling, the evaporator fouling, and the refrigerant leakage of an air-conditioning system, were considered. The fault diagnosis algorithm was tested by using a fault simulation facility. Test results showed that the algorithm developed for this study was effective to detect and diagnose various faults. Therefore, this algorithm may be practically used for the fault diagnosis of an air-conditioning system.