• Title/Summary/Keyword: Facility maintenance

Search Result 872, Processing Time 0.031 seconds

Current Statues of Outdoor Exercise Equipment and Improvement Research - Focused on the Neighborhood Park of Dongtan New Town - (야외체력단련기구 이용현황과 개선방안에 관한 연구 - 동탄신도시 근린생활권 근린공원을 중심으로 -)

  • Kim, Do-Kyong;Kim, Seung-Hwan
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.39 no.1
    • /
    • pp.84-95
    • /
    • 2011
  • The purpose of this study is to increase the usage of satisfaction of outdoor exercise equipment installed at parks when plans and designs are made for renovation or formation of parks. In order to do so, the study surveyed and analyzed the usage satisfaction of 150 men and women who use outdoor exercise equipment in neighborhood parks located in Dongtan New Town. There were four factors that affect the variables of usage satisfaction. They can be defined as the main facility factor, awning factor, maintenance factor, and additional facility factor. From the result regression analysis of the total satisfaction rate and the factors, the main facility factor was the most influential of the variables. This could indicate that the facility factor affects the satisfactory rate of outdoor exercise equipment. This research is done only with the examples of neighborhood parks, so it limits the possibility of analysis of seasonal use. It is necessary to conduct analysis research of parks which installed many outdoor exercise equipment, such as a vest-pocket park, children's garden, and pedestrian/urban/metropolitan neighborhood parks.

Residual Settlement Behavior in Soft Ground Improved by PBD during Operating Facilities (PBD공법이 적용된 연약지반에서 운용 중인 시설물의 잔류침하거동)

  • Kang, Gichun;Kim, Taehyung;Jeong, Choonggi
    • Journal of the Korean GEO-environmental Society
    • /
    • v.15 no.8
    • /
    • pp.13-21
    • /
    • 2014
  • The Plastic Board Drain is used to improve soft soils deposited in container terminal area at a port. This paper describes settlement behavior of soft ground in this area from PBD installation to the time of operating facilities. Previous researches focused on soil improvement effect of PBD, that is, the settlement occurred during ground improvement period. The residual settlement occurred during operating the facility is very important from the maintenance and management point of view. However, the study of this residual settlement has been rarely conducted. In this study, by analyzing the measured settlement data obtained from the container terminal area at the port, it was verified that the residual settlement induced during operating facilities occurred in a layer with PBD improvement. In addition, by comparison the settlement predicted by a numerical analysis with the settlement measured in the field, it was confirmed that the actual settlement is in the range of predicted settlement.

Suggestion for the Maintenance Program of the Sea Dike Using Geophysical Methods (지구물리학적 방법을 이용한 방조제 유지·관리 체계 제안)

  • Yong, Hwan-Ho;Cho, In-Ky;Song, Sung-Ho
    • Geophysics and Geophysical Exploration
    • /
    • v.16 no.4
    • /
    • pp.275-283
    • /
    • 2013
  • The sea dike is the most important facility of reclamation projects, and plays an important role in securing freshwater in the reservoir. Systematic research on practical approaches and data analysis techniques are lacking even though some geophysical methods such as electrical resistivity and self-potential surveys are included within the inspection processes. Hence, geophysical methods were considered for improvement of precision safety diagnosis methods after problems in the maintenance system have been identified, such as safety checks and precision safety diagnoses. In addition, geophysical methods customized according to variations in ambient environmental limiting factors such as pore pressure changes by tidal fluctuation, compaction characteristics of the fill materials, and the surface condition of the embankment were suggested.

History Management Technology of Building Construction and Maintenance Using Vector Photo Information and BIM (벡터사진 정보와 BIM을 활용한 건축물의 시공·유지관리 이력관리기술)

  • Kim, Kyoon-Tai;Lim, Myung-Gu;Kim, Gu-Taek
    • Journal of the Korea Institute of Building Construction
    • /
    • v.14 no.6
    • /
    • pp.605-613
    • /
    • 2014
  • Recently proposed intelligent images are generating, storing and managing along with existing image information and 5W1H information. Therefore, these vector images can be useful in searching and managing photos taking during building construction and maintenance processes. In addition, when the vector photos, a key to the intelligent image, is linked with BIM, it is possible to find BIM objects by utilizing information included in vector photos. And if the taken vector photo is saved as attributes of the extracted object, the vector photo can be managed as the historical data. Furthermore, this new technology will contribute to make the management of construction information more efficiently. This study is about the development of the technology of extracting BIM objects from vector photo information and managing the attributes of the extracted objects. Also the prototype modules was developed and tested to evaluate the processes of setting reference points, converting coordinate system, calculating positions, and so on. Through these processes, it was confirmed that the possibility of extracting BIM objects from vector photos and of managing attribute data of objects.

Indoor Air Quality in Various Type of Public Facilities at Honam Province (호남지역의 다중이용시설별 실내공기질 실태 조사)

  • Seo, Byeong-Ryang;Jeong, Man-Ho;Jeon, Jun-Min
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.5 s.92
    • /
    • pp.387-397
    • /
    • 2006
  • This study was performed to investigate the characteristics of indoor air quality(IAQ) in 91 public facilities from September 2004 to March 2005 in the Honam province(Chonnam, Gwangju). The measured air pollutants are $PM_{10}$, formaldehyde(HCHO), CO, $CO_{2}$ and total suspended bacteria(TSB), the maintenance standard materials of IAQ management law established by ministry of environment in Korea(MOE). We also surveyed establishment and operation of ventilation equipment. It was measured $1.2m{\sim}1.5m$ on the floor between 8 o'clock AM and 7 o'clock PM. As the result, $PM_{10}$ and CO was showed the highest concentration, $188.89{\mu}g/m^{3}$, 8.67 ppm, at the indoor parking. The concentration of HCHO was the highest in large store and steamer room. The concentration was respectively $118.70{\mu}g/m^{3}\;and\;113.21{\mu}g/m^{3}$. The concentration of $CO_{2}$ was the highest at the reading room of the library on the condition of natural ventilation. The concentration of $CO_{2}$ was 1,816 ppm and higher than the IAQ standards established by MOE. The TSB was just measured in the hospital and silver town. It was the highest at the admission room of hospital. The concentration of TSB was $766CFU/m^{3}$. The public facilities of this study were not exceed each maintenance standards except $CO_{2}$ but it was surveyed that the management will be needed about some air pollutant according to target facilities.

A Study of Evaluation System of NATM Tunnel using Delphi and AHP (델파이 및 AHP 기법을 활용한 NATM 터널의 평가체계 연구)

  • Park, Kwang-Rim;Chung, Jee-Seung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.6
    • /
    • pp.25-34
    • /
    • 2017
  • Since the 30-year-old facility is expected to surge from 10.5% to 23.9% in 10 years, the new evaluation system is needed to establish efficient maintenance system for securing the safety and extending the life span of existing facilities. In this study, Delphi and AHP(Analytic Hierarchy Process) was conducted to provide a systematic new evaluation system for the NATM tunnel, which is the most frequently constructed structure of the existing tunnel. Since the existing assessment systems are limited in scope of evlauatuon criteria, the survey was conducted in conjunction with closed questionnaires on existing items and open questionnaires for eliciting new items. In results, suitable evaluation factors were derived for the NATM tunnel through the validation of the survey results. Also after calculating weighted value of the derived assessment item using AHP technique, a new evaluation system is proposed to meet the characteristics of the NATM tunnel, so that they can be used as reference materials for revising and supplementing detatiled guidelines in the future.

Lateral Load Distribution Estimation of a PSC Girder Bridge from Dynamic Loading Test (동적재하시험을 통한 PSC 거더교의 횡분배 측정)

  • Kim, Sung-Wan;Cheung, Jin-Hwan;Kim, Seong-Do;Park, Jae-Bong;Lee, Myoung-Jin
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.3
    • /
    • pp.60-68
    • /
    • 2017
  • Since the bridge is the main facility of the road that is the core of the civil infrastructure, the bridge is constructed to ensure stability and serviceability during the traffic use. In order to secure the safety of bridges, evaluating the integrity of bridges at present is an important task in the maintenance work of bridges. In general, to evaluate the load carrying capacity of bridges, it is possible to confirm the superimposed behavior and symmetric behavior of bridges by estimating the lateral load distribution factor of the bridges through vehicle loading tests. However, in order to measure the lateral load distribution factor of a commonly used bridge, a static loading test is performed. There is a difficulty in traffic control. Therefore, in this study, the static displacement component of the bridge measured in the dynamic loading test and the ambient vibration test was extracted by using empirical mode decomposition technique. The lateral load distribution was estimated using the extracted static displacement component and compared with the lateral load distribution factor measured in the static loading test.

Evaluation of Tension of PSC Box Girder Bridges Using Risk Matrix (리스크 매트릭스를 활용한 PSC박스 거더교의 긴장재 평가)

  • Kim, Hyungjo;Ji, Seunggu;Kim, Hunkyom;Kim, Pilsoo;Kim, Hunkyom;Lee, Minjae
    • Korean Journal of Construction Engineering and Management
    • /
    • v.19 no.5
    • /
    • pp.53-60
    • /
    • 2018
  • In particular, the investigation of tendons in PSC Box Girder Bridge should be done in a systematic way. It is important to identify preventative maintenance activities that should be carried out in order to analyze the risk factors by type of representative tensions and to reduce risks in the long term. However, in the current maintenance system, various methodologies for investigating and repairing tensions have been studied, but it is difficult to investigate precisely tensions. Therefore, to apply the risk assessment for screening of tensions to the domestic PSC Box Bridge, we presented a risk matrix evaluation index that is consistent with the state assessment and maintenance system.

Conceptualizing a Strategic Facilities Management Decision Framework for Heritage Building Maintenance Management

  • Adegoriola, Mayowa I.;Yung, Esther H.K.;Lai, Joseph H.K.;Chan, Edwin H.W.
    • International conference on construction engineering and project management
    • /
    • 2022.06a
    • /
    • pp.992-1000
    • /
    • 2022
  • Heritage buildings (HBs) as structures with historical and architectural relevance that form an integral part of contemporary society. HBs deserve to be protected for as long as possible to retain their significance. Therefore, prioritizing HB maintenance management (HBMM) is pertinent. However, the decision-making process of HBMM can be relatively daunting. The decision-making challenge may be attributed to the multiple 'stakeholders' expectation and requirement which needs to be met. To this end, professionals in the built environment have identified the need to apply the strategic concept of facilities management (FM) in decision making. However, studies exploring the application of FM in decision-making seem lacking. To bridge this gap, this study focuses on developing a framework for strategic decision-making HBMM, which helps achieve HBMM sustainability. At the study's inception, relevant works of literature in the domains of HBMM and FM were conducted. This review helped identify contemporary maintenance practices and their applicability to HBMM. Afterward, a conceptual framework to aid decision-making in HBMM was developed. This framework integrated the concept of FM scope (people, place, process, and technology) while ensuring that decisions and plans were made at strategic, tactical, and operational levels. The conceptual framework presents a holistic guide for professionals in HBMM to ensure that decision processes and outcomes are practical and efficient. It also contributes to the existing body of knowledge on the integration of FM in HBMM. Furthermore, it will help achieve HB sustainability through an effective decision-making process.

  • PDF

Development of an Economic Evaluation model for Coating System Based on Environmental Conditions of Power Generation Structure (발전구조물의 환경조건을 반영한 도장계 선정 경제성 평가 모델 개발)

  • Kim, In Tae;Lee, Su Young;An, Jin Hee;Kim, Chang Hak
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.40 no.1
    • /
    • pp.77-85
    • /
    • 2020
  • Currently, life-cycle cost analysis methods are introduced to maintain large infrastructure facilities in Korea. However, there are not many cases in which maintenance models are applied that reflect conditions such as the location of a facility and its surroundings. In order to establish an appropriate maintenance strategy, a cost prediction, deterioration model, and a decision model reflecting uncertainty should be established. In this study, an economic analysis model was developed for long-term cost planning and management based on user decisions based on maintenance methods and judgment criteria for painting specifications applied to power generation structures. The performance of the paintwork was assessed through the paint deterioration test for the application of the economic analysis model, and the results of the economic analysis according to the applied paint specifications (Urethan, polysiloxane, fluorine) were verified by applying the proposed economic analysis model. In this study, it is believed that the selection of the repair cycle and evaluation methods applied with the development model rather than the performance of the painting can be expected to be used as basic data for the maintenance cycle, even if it is not limited to the painting.