• Title/Summary/Keyword: Facility Field Research

Search Result 485, Processing Time 0.03 seconds

Characteristics of a Corona between a Wiring Clamp(Dead End Clamp) and a Porcelain Insulator Used in a 154[kV] Power Receptacle

  • Han, Un-Ki;Kim, Jong-Min;Bang, Sun-Bae;Kim, Han-Sang;Choi, Hyeong-Jun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.9
    • /
    • pp.57-63
    • /
    • 2007
  • The occurrence of a corona is that electrical discharge due to the heterogeneity that occurs when an electrical field is concentrated in an electrode due to a cusp formed on said electrode. Wire treatment at the end of a 154[kV] dead end clamp for end users accelerates the occurrence of corona, which in turn leads to power loss and noise. In this study, the characteristics of the corona which occurs between porcelain insulators and support clamps of overhead lines used in 154[kV] power receiving facilities for end users were investigated. The corona, which cannot be identified by one common method, was measured utilizing a UV image camera. A risk assessment for fire damage and its status was suggested. The stress distribution of the electrical field by length of bare wire was suggested by means of the finite element method(FEMLAB). As a result, it was found to affect a porcelain insulators. These results can be utilized for the enhancement of clamp installation and safety in power facilities.

A Study on the Antecedents of Research Facility Public Usage Enhancement: Focusing on Service Quality, User Satisfaction and Reuse/Recommendation Intention in the Case of RFID/USN Support Center (공공 연구시설 활용 증진의 선행요인에 대한 연구: RFID/USN 종합지원센터의 서비스품질, 이용자만족, 재이용 및 추천의도를 중심으로)

  • Yoo, Seuck-Cheun;Jung, Uk;Park, Chan-Kyoo
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.35 no.2
    • /
    • pp.37-51
    • /
    • 2010
  • Understanding the antecedents of high public usage of national R&D facilities is a critical issue for both academics and facility managers. Previous researchrelated to general service management has identified service quality and user satisfaction as important antecedents of reuse and recommendation intention. The current paper reports findings from a survey which looked into the impact of service quality dimensions and user satisfaction on reuse and recommendation intention in the field of R&D facility public usage. Findings indicate that service quality appears to be linked to user satisfaction, and user satisfaction to be linked to reuse and recommendation intention. Findings also indicate that user satisfaction played as a mediator on the relationship between service quality and reuse/recommendation intentions in R&D facility public usage domain.

A Study in the Selection Factors of Facility Management(FM) Enterprises Using AHP Analysis (AHP 분석을 활용한 Facility Management(FM) 기업의 선택 요인에 관한 연구)

  • Han, Sanghun;Kim, Seungchul;Park, Sohyun
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.42 no.3
    • /
    • pp.193-205
    • /
    • 2019
  • Looking at recent safety accidents in buildings, most of them due to lack of FM expertise, and this is due to human resources. In each all industry areas, some companies are competitive, representational, and leading in the market through long-term expertise and research in their respective fields. In the field of FM industry, some companies offer core-competencies in internal and external innovative building management through competition with others. However, old custom and old management form still exist in the FM field. However, an old custom and old management system still exist in the FM field; it forces cost-cutting and caused by carelessness in technical development competitiveness and safety measures. The government control by safety inspection and facility inspection through legislation of building management, but the management is still weak as a side of in the facility management section due to inspect sth as a mere formality and submit a paper report. These facts exist different kind of usage of the building have a three-party encounter between a building owner, user, and FM enterprises. In this research identify survey, especially building owner (manager)'s choice perception priority for optional factors to choose FM enterprises. Based on this, FM enterprises will be forced to seek a new dimension for better building management. In this light, the purpose of the research is to shape changes in the FM market culture safely and providing better service in building management and understanding building owner's insight through this research's information.

Effects of Human Safety due to Leakage Current by Outdoor Electrical Facility in the Submerged Condition(I) (옥외 전기시설물 침수시 누설전류에 의한 인체영향(I))

  • Ha, Tae-Hyun;Lee, Hyun-Goo;Kim, Dae-Hyeong;Bae, Jeong-Hyo;Lee, Ji-In;Kim, Suk-Won
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.244-246
    • /
    • 2002
  • In this paper, We studied about effects of human safety due to leakage current on the point of cable connection for outdoor electrical facility in the submerged condition and conducted its evaluation in the testing field. In this case, the reason of leakage on the point of cable connection is caused by formation of electrical pass between the grounded outdoor electrical facility and the enclosure of electrical facility which is connected to grounding system.

  • PDF

Effects of Human Safety due to Leakage Current by Outdoor Electrical Facility in the Submerged Condition(II) (옥외 전기시설물 침수시 누설전류에 의한 인체영향(II))

  • Ha, Tae-Hyun;Lee, Hyun-Goo;Kim, Dae-Kyeong;Bae, Jeong-Hyo;Lee, Ji-In;Kim, Suk-Won
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.247-249
    • /
    • 2002
  • In this paper, We studied, about effects of human safety due to leakage current on the point of cable connection for outdoor electrical facility in the submerged condition and conducted its evaluation in the testing field. In this case, the reason of leakage on the point of cable connection is caused by formation of electrical pass between the grounded outdoor electrical facility and the other outdoor electrical facility which is disconnected to grounding system.

  • PDF

The Near-field Behavior of Effluent discharged from Confined Disposal Facility (제한투기시설에서 배출되는 여수의 근역거동)

  • 정대득;이중우
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2000.11a
    • /
    • pp.95-107
    • /
    • 2000
  • The primary purpose of dredging work is to maintain navigational readiness and to increase environmental amenity, so that the dredging project which is composed of excavating, removing, transporting, storing and disposing dredged material must be carefully managed to insure that dredging works are completed in a cost-effective and environmentally safe manner. The most important point in dumping operations is an estimating and reducing the impacts of discharges at the dumping area. One of the most effective method for the reduction of ecological impacts at dumping area is using the schematic process composed of the sophisticated plan, precise work and predicting/reducing the impacts based on the numerical model and field observation. In this study, the numerical model is used to predict the near-field spatial fate and begavior of effluent discharged from Confined Dumping Facility(CDF) located near coastal area. To to this purpose, reappearing of tidal current was preceded. The model is then applied to Mokpo harbor, where capital dredging and maintenance dredging are conducted simultaneously and the CDF is under construction;. In the series of model case study, we found that the near-field behavior of effluent discharged from CDF was governed by the receiving water condition, outfall geometry, characteristics of efflent and CDF operating conditions.

  • PDF

Study on the Decommissioning of Small Nuclear Facility through Analyzing Foreign Decommissioning Practices (국외 해체 사례 분석을 통한 국내 소규모 방사선이용시설 해체에 관한 연구)

  • Kwon, Dayeong;Kim, Yongmin
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.3
    • /
    • pp.125-130
    • /
    • 2015
  • RI & RG are used in various field such as medical field, industrial field, agricultural and food&life field. The number of small nuclear facilities is on the increase. We need to take an interest in decommissioning of small nuclear facility and predict the occurring problem from facility decommissioning. Because of the relatively low radiation risk, the preparation of the small nuclear facility dismantling is often neglected. As the accident in Goiania, Brazil showed, the impact of the decommissioning of small nuclear facilities is not less than the large nuclear facilities although it may seem dangerless. Therefore, we analyzed the each institutional characteristics of the decommissioning of small nuclear facilities through foreign case study on this research. Also, we proposed several considerations on decommissioning such as reuse of facility and source, lack of space, stakeholder involvement and failures of protection. Through these study, we tried to make guideline of the small nuclear facilities decommissioning.

Electric Field Strength and Shielding Effectiveness Comparison According to the Size of Shielding Facility (방호 시설 크기에 따른 전계강도 및 차폐 효과 비교)

  • Kang, Ho-Jae;Huh, Chang-Su;Bang, Jeong-Ju;Choi, Jin-Su;Park, Woo-Chul
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.27 no.4
    • /
    • pp.221-225
    • /
    • 2014
  • In modern times, threat of high power electromagnetic wave is increasing. When the electrical grid and communication network are attacked by these high power electromagnetic wave, the whole infrastructure is paralyzed. To protect the infrastructure from these high power electromagnetic wave threat, the shielding facility that can block high power electromagnetic wave is constructed. Also shielding effectiveness evaluation about the constructed facility is important. But, because of space efficiency and saving of construction cost to construct the actual shielding facility, the shielding room wall is generally adjacent to exterior concrete structures. As space between shielding facility wall and concrete structures is very small, arranging the transmitting antenna exterior shielding facility is realistically difficult. Therefore, in this research, The shielding effectiveness measurement plan in the state of exterior narrow space of HEMP shielding facility is presented. And to apply this plan, The influence of shielding effectiveness according to the size of the shielding facility is analyzed.

Design of online damage images detection system for large-aperture mirrors of high power laser facility based on wavefront coding technology

  • Fang, Wang;Qinxiao, Liu;Dongxia, Hu;Hongjie, Liu;Tianran, Zheng
    • Nuclear Engineering and Technology
    • /
    • v.53 no.9
    • /
    • pp.2899-2908
    • /
    • 2021
  • The laser transport system of the high power laser facility is mainly composed of large-aperture laser transport mirrors (TMs). Obtaining the high-resolution online damage images during the operation, which is of great significance for operating safely of the mirrors and the facility. Based on wavefront coding, pan-tilt scanning and image stitching technologies, an online laser-damage images detection system is designed, and it can achieve high-precision detection of surface characteristics of large-aperture laser transport mirrors. The preliminary simulation proves that the system can solve the depth of field matching problem caused by pan-tilt tilt imaging and achieve higher resolution.

ERGONOMIC ANALYSIS OF A TELEMANIPULATION TECHNIQUE FOR A PYROPROCESS DEMONSTRATION FACILITY

  • Yu, Seungnam;Lee, Jongkwang;Park, Byungsuk;Kim, Kiho;Cho, Ilje
    • Nuclear Engineering and Technology
    • /
    • v.46 no.4
    • /
    • pp.489-500
    • /
    • 2014
  • In this study, remote handling strategies for a large-scale argon cell facility were considered. The suggested strategies were evaluated by several types of field test. The teleoperation tasks were performed using a developed remote handling system, which enabled traveling over entire cell area using a bridge transport system. Each arm of the system had six DOFs (degrees of freedom), and the bridge transport system had four DOFs. However, despite the dexterous manipulators and redundant monitoring system, many operators, including professionals, experienced difficulties in operating the remote handling system. This was because of the lack of a strategy for handling the installed camera system, and the difficulty in recognizing the gripper pose, which might fall outside the FOV (field of vision) of the system during teleoperation. Hence, in this paper, several considerations for the remote handling tasks performed in the target facility were discussed, and the tasks were analyzed based on ergonomic factors such as the workload. Toward the development of a successful operation strategy, several ergonomic issues, such as active/passive view of the remote handling system, eye/hand alignment, and FOV were considered. Furthermore, using the method for classifying remote handling tasks, several unit tasks were defined and evaluated.