• 제목/요약/키워드: Facility Area

검색결과 1,862건 처리시간 0.032초

(중요도-성취도)분석에 의한 청소년수련시설 운영실태 조사연구 (A Research on the Youth Facilities Management with Importance-Performance Analysis)

  • 구태익
    • 한국조경학회지
    • /
    • 제23권2호
    • /
    • pp.137-147
    • /
    • 1995
  • This research is a preliminary study to improve the criteria of youth facilities which regulated in Youth Fundamental Act, with the method of Importance-Performance Analysis on youth facilities management. Evaluation inquiry had been made, and were collected from the youth facility managers who attended The Korean Youth Facility Managers' Seminar held on 24th Nov. 1994 at Pakdaljae Youth Center. The results are as follows; 1. Keep Up the Good Work : indoor facilities in community area, and outdoor facilities and accommodations in natural area are resulted in high in Importance and. Performance. They need to be operated constantly. 2. Concentrate Here : Counselling room, hobby room and outdoor meeting places in community area, and care room in natural area are perceived high in Importance but low in Performance. They need to provide proper leaders and equipment. 3. Low Priority : Care room, forest and outdoor facilities in community area, arid forest and folk playground in natural area are low in both Importance and Performance. So, it is considered that they are not necessary ones in both areas, but some outdoor facilities are so essential in natural area that they need to be provided properly. 4 Possible Overkill : Courtyard and library in community area, and outdoor facilities in natural area are low in Importance but high in Performance. They need to improve their importance through the development of applicable activity programs.

  • PDF

병영 생활관 시설 분류 개선에 관한 연구 - 육·해·공·해병대 설문 조사 및 군 간부 면담 조사를 중심으로 - (Study on facility classification development of Military Barracks - Focusing on the questionnaire survey and military officials' interview of the army, navy, air force and Marine -)

  • 성이용;이상호
    • 한국실내디자인학회논문집
    • /
    • 제22권1호
    • /
    • pp.19-27
    • /
    • 2013
  • The objective of this study was to establish Facility classification for military barracks among military facilities. The military barracks are the place where soldiers spend most of their time. Thus, a new type of space in military barracks is required to improve the quality of life of the soldiers and make the military more advanced for national defense. The research method was to derive problems through a survey of the previous literature and case studies and to select target places in the Army, Navy, Air Force, and Marine based on the derived problems. An improvement scheme was proposed by developing criteria for military barracks spaces through a questionnaire survey. The following results were obtained: Facility classification inside of national defense military facility standard should be reorganized. The alternative plan is demanded for some camp which has no need about setting up the office facility. And the study of reasonable facility area after improvementing facility categorization is required.

수소 취급설비의 누출원에 인접한 방폭전기기기의 가스그룹 IIC 기기 회피 방안에 관한 연구 (A Study on the Method to Avoid the Gas Group IIC Equipment of Explosion Proof Electrical Equipment Adjacent to the Source of Release of Hydrogen Handling Facility)

  • 변윤섭
    • 한국수소및신에너지학회논문집
    • /
    • 제33권4호
    • /
    • pp.383-390
    • /
    • 2022
  • Appropriate explosion proof electrical equipment should be installed in hazardous areas. In areas where hydrogen is handled, explosion proof electrical equipment adjacent to the hydrogen handing facility must be reviewed for selection of gas group IIC (or IIB+H2) equipment. When selecting explosion proof electrical equipment for the flammable substance handling facility in areas where hydrogen and flammable substance are handled, the method to avoid gas group IIC (or IIB+H2) equipment has been suggested by using the operating pressure of the hydrogen handling facility. When the operating pressure of the outdoor hydrogen handling facility is 1.065 MPa or less, it has been confirmed that there is no need to install gas group IIC (or IIB+H2) equipment for the flammable substance handling facility adjacent to the hydrogen handling facility. And the method of selecting explosion proof electrical equipment for the flammable substance handling facility has been suggested as a flowchart, so it will be able to be utilized when selecting appropriate explosion proof electrical equipment.

농촌지역 학교시설의 재구성에 대한 사례 연구 -의성군을 중심으로- (A Case Study on the Reorganization of School Facilities in the Rural Area -Focused on Uiseong-gun-)

  • 양금석
    • 한국농촌건축학회논문집
    • /
    • 제13권3호
    • /
    • pp.37-44
    • /
    • 2011
  • This study is to clarify the actual conditions of school facilities in the rural area. The purpose of this paper is to present the direction for reorganization of school facilities. Surbey area was Uiseong, Gyeongbuk, the number of students decreased rapidly. And elementary, middle and high school facilities were surveyed. The results are as the follows; 1)After consider living zone, commuting distance, opinions of residents, it is advisable that the small size school(the number of students under 60) will be combined stronghold school. 2)Reorganization of school facilities should be considered that the characteristics of living zone, exchanging educational program between elementary and middle schools and an integrated use of the facility.

블록별 부지분류 적용 해안시설 영역에서의 HAZUS 기반 지진피해 추정 (Preliminary Estimation of Earthquake Losses Based on HAZUS in a Coastal Facility Area with Blocks Applying Site Classification)

  • 선창국;천성호
    • 한국지리정보학회지
    • /
    • 제17권4호
    • /
    • pp.10-27
    • /
    • 2014
  • HAZUS-MH는 지진, 홍수 및 허리케인의 세 가지 다중 재해현상에 대한 잠정적 손실을 추정하기 위한 GIS 기반의 컴퓨터 프로그램이다. 지진 재난에 대해서는 HAZUS에 설정한 가상이나 실제 지진 특성에 따라 지진동의 세기가 평가되고 이에 따라 손실을 계산하게 된다. 본 연구에서는 해안 플랜트시설 영역의 향후 지진에 대한 대비의 일환으로 HAZUS를 활용하였다. 대상 시설 영역의 특성 평가를 위해 기존 지반조사 보고서를 토대로 지반특성 자료들을 취합하였다. 또한, 시설구조물들의 재료 및 구조 특성에 따라서도 분류하였다. 연구 영역은 부지 조성 및 시설 분포 상황을 고려하여 17개 블록으로 나누고 지반 조건을 내진설계기준의 부지분류 체계에 따라 구분하였다. 뿐만 아니라, 수치 모델링을 통해 주요 시설물들의 지진취약도 곡선들을 도출하고 HAZUS 데이터베이스에 적용하였다. 이 연구 영역에 대한 HAZUS 활용 추정 결과는 부지 조건 및 구조물 종류에 따라 다양한 지진 피해와 손실 정도를 보였다. 본 사례 연구를 통해 해안시설 영역의 지진 피해 평가를 위한 HAZUS의 적용 가능성을 확인하였다.

읍.면 지역 최저주거기준 방향 설정 및 기준안 제시 (Proposal of Minimum Housing Standard for Eup-Myun Area)

  • 윤희정
    • 농촌계획
    • /
    • 제17권2호
    • /
    • pp.13-21
    • /
    • 2011
  • The federal government has been implemented several housing policies attempting to improve living quality at Eup-Myun area(rural area), but those were mostly fund supports to reconstruct or repair houses. Existing minimum housing standard is focused on urban apartments and indoor space, but the houses of Eup-Myun area are scattered and are different from urban's house space. Therefore, this study focused on these area, and intended to propose suitable minimum housing standard for Eup-Myun area. Based on literature reviews about housing standard of England, U.S., Japan and South Korea, questionnaire survey was given to 50 experts divided into 2 groups, professors of architecture and researchers on rural environment. This study proposed the direction of new minimum housing standard of Eup-Myun area, it could be added to 2 household composition, be divided into 2 groups, agricultural and non-agricultural residents into facility guideline, be added to outdoor facilities, for example warehouse and open yard, and finally be inserted water quality into environment standard. The results of this study provide insightful strategies for rural housing standard.

노인전문요양시설의 프로그램 실시 공간 사용실태 (A Survey on Space Use by Program of Skilled Nursing Facilities for the Elderly)

  • 이민아
    • 대한가정학회지
    • /
    • 제43권10호
    • /
    • pp.125-139
    • /
    • 2005
  • The purpose of this study was to provide basic information about the program space planning of skilled nursing facilities for the elderly in order to consider elderly health and diversity and to improve their rehabilitation ability. A mail survey was undertaken and 58 out of 78 facilities $(74.4\%)$ responded to the questionnaire. The answers of $56 (71.8\%)$ were used for analysis. The results of the study were as follows. Many programs, especially exercise, recreation, and facility events programs that require dynamic activity, were conducted in the lounge of the facilities because that area was wide with various equipments such as tables, sofas, and sound facilities, and did not require any huge movements of the elderly since it was very close to the elderly individual rooms. The art and human knowledge programs, managed with small groups, were peformed in separate program rooms or elderly individual room so that the elderly could pay attention to the programs. On the other hand, as for the design elements, the spaces for the art and human knowledge programs required good lightings and separate program rooms. The area of the spaces for the exercise, recreation and facility events programs was found to be the most problematic element, even though they were performed in the comparatively wide lounge. For future research, a field observation study is suggested to analyze the detail relations among the program spaces.

일본 유니트형 노인요양시설의 기능별 공간구성 분석 - 동북지방 농촌지역 5곳 사례를 중심으로 - (Space arrangement Analysis of Unit Care Facility in Japan - 5 Case Study in Tohoku Rural Area -)

  • 남윤철
    • 한국농촌건축학회논문집
    • /
    • 제20권3호
    • /
    • pp.37-45
    • /
    • 2018
  • There are many advantages to unit-care welfare facilities' care services for the elderly in Japan. The field research was conducted after holding interviews with employees at five elderly welfare facilities in Japan. This research analyzes the space arrangement of unit-care welfare facilities in Japan's Tohoku rural area. The purpose of this study is to provide design data on the space arrangement of a unit-care facility for Korea. The results of research are as follows. 1. Cafes, restaurants, and stores were operated in the elderly welfare facilities, which were open to the general public as well. Therefore, local residents frequently visited. 2. The kitchen, living rooms, private bedrooms and construction of the elderly welfare facilities were similar to that of normal residential houses. 3. The event hall is conveniently located at the center of the facility. 4. It was easy to understand the health status of the elderly by having a health office in the open living room. 5. There were open spaces which are frequently used by the homebound elderly, including room rehabilitation, daycare and short term residence. The above results will be used for space planning data in Korean unit-care facilities.

공장 및 제조장 난개발 방지를 위한 지구제 적용방안에 관한 연구 -화성시를 사례로- (A Study on the Applied Zoning System for the Preventing Reckless Developments due to Industrial Facility Construction -A Case Study on Hwasung-)

  • 김철홍;이원영;최형석
    • 한국환경복원기술학회지
    • /
    • 제5권5호
    • /
    • pp.45-57
    • /
    • 2002
  • This study aims to suggest the applied zoning system for preventing reckless developments due to individual industrial facility construction. According to the types of reckless developments which has been found in Hwasung, the applied zoning system including 4 kinds of districts can be proposed. Collective Inducement District can be designated to where many industrial facilities have already existed with poor infrastructure, and the other districts such as Residential Area Protection District, Reservoir-Around and Agricultural Area Protection District, or Landscape Protection District may be designated to the sites where reckless developments due to individual industrial facility construction may happen. This zoning system seems to be used as a guideline of new zoning of revised NLUPL(National Land Use and Plan Law) after the execution.

Specific Process Conditions for Non-Hazardous Classification of Hydrogen Handling Facilities

  • Choi, Jae-Young;Byeon, Sang-Hoon
    • Safety and Health at Work
    • /
    • 제12권3호
    • /
    • pp.416-420
    • /
    • 2021
  • Hazardous area classification design is required to reduce the explosion risk in process plants. Among the international design guidelines, only IEC 60079-10-1 proposes a new type of zone, namely zone 2 NE, to prevent explosion hazards. We studied how to meet the zone 2 NE grade for a facility handling hydrogen gas, which is considered as most dangerous among explosive gases. Zone 2 NE can be achieved considering the grade of release, as well as the availability and effectiveness of ventilation, which are factors indicative of the facility condition and its surroundings. In the present study, we demonstrate that zone 2 NE can be achieved when the degree of ventilation is high by accessing temperature, pressure, and size of leak hole. The release characteristic can be derived by substituting the process condition of the hydrogen gas facility. The equations are summarized considering relation of the operating temperature, operating pressure, and size of leak hole. Through this relationship, the non-hazardous condition can be realized from the perspective of inherent safety by the combination of each parameter before the initial design of the hydrogen gas facility.