• Title/Summary/Keyword: Facility Area

Search Result 1,867, Processing Time 0.029 seconds

A Study on the Functional Area Composition and Correlation Factors of Elderly Care Floor in Nursing Home (노인요양시설 요양층의 기능별 면적구성과 상관요인에 관한 연구)

  • Yoon, So-Hee;Kim, Suk-Tae
    • Korean Institute of Interior Design Journal
    • /
    • v.24 no.3
    • /
    • pp.156-164
    • /
    • 2015
  • Nursing Homes do not have a defined standard in the space area nor does it have a detailed standard facility requirement by law. This can possibly lead to the deterioration of the facility and the system. This directly affects the medical treatment space area within the nursing home. The medical treatment area provides medical treatment to seniors and this is where the seniors get most of their daily services. Therefore, this is research is about the study of the space area of the medical center and the ratio trend of the space area for the medical treatment facility located in senior nursing homes. Ten facilities have been selected in this study to analyze the correlation factors between space area and its trends. The analysis performed includes the conditions relating to the area and what affects the center. We have followed up with a proposal for improvement of the facility and area configuration for the medical treatment facility. Based on the analysis, the following conclusion can be made: First, the senior welfare centers are mostly used as a residence purpose followed a temporary stay of residence facility for the seniors. Second, research indicates that the bigger the facility, nursing and public functions took a larger portion of the space area compared to other services within the senior welfare centers. Third, the study shows the management space area took up about 1%~6% of the entire medical center within the nursing home which is a narrow space area because of the integrated management. Fourth, analysis based on the trend in the time-series indicate after the adoption of the system, there is a continued decline in the space area of nursing, management and public areas. Lastly, since before and after 2008, the space area composition of the nursing facility shows a continuous decline in our study. We can safely conclude that the revised senior welfare act's construction plan has an effect in the facility and is effectively working to meet its requirement. Therefore, the revision of the law is required to reflect the social needs of the residents.

The Development of National Framework Data Model in Facility Area (시설물분야 기본지리정보 데이터모델 개발)

  • 이현직;박은관;최동주
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.22 no.2
    • /
    • pp.161-170
    • /
    • 2004
  • This study is to standardize framework data model in facility area. This study focuses on standization of application oriented data model in facility management and other facility applications. In order to outline the framework data model in facility area, building and cultural sub-themes which have been proposed in a previously conducted research have initially been considered. Also various international and domestic standards in framework data for facility area have been analyzed to identify appropriate feature classes and types. In order to avoid future conflicts, many facilities experts from various facility areas including facility database and facility manarement have provided their inputs in this study based on their viewpoints and prospects. As a results of this study, we are developed to features and data model or framework data in facility area.

A Facility Design Model for 1300 Capacity School Foodservice with Adjacency and Bubble Diagrams (근접요구도와 버블다이어그램을 적용한 1300식 규모의 학교급식 시설 설계 모델)

  • Jang, Sun-hee;Chang, Hye-Ja
    • Korean Journal of Community Nutrition
    • /
    • v.16 no.1
    • /
    • pp.98-112
    • /
    • 2011
  • This study aimed to suggest a 1300 scale of a middle school foodservice facility floor plan which was compliant to the principle of HACCP, as well as ensuring food and work safety, and the flow of personnel and food materials. which consisted of 46 nutrition teachers and 6 experts, responded with a questionnaire on the relationship of functional area and space. Using their opinions, key principles for the design of the facility were single direction movement of food materials, customers and workers; minimization of the cross-contamination through the separation of functional space; and securement of customer-focused efficiency; staff-centered convenience and efficiency; and work and food safety. After the completion of an adjacency diagram, bubble diagram and program statement, the functional areas of a 1300 scale middle school food-service facility were allocated as follows: $9.9\;m^2$ for the receiving area, $56.1\;m^2$ for the pre-preparation area, $10.5\;m^2$ for the food storage area, $6.0\;m^2$ for the supplies storage area, $97.8\;m^2$ for the cooking area, $33.6\;m^2$ for the service area, $52.5\;m^2$ for dish washing area, cafeteria $410.5\;m^2$, $4.5\;m^2$ for the front room, for a total of $725.8\;m^2$. Expert groups have pointed to limitations within this model as there are no windows in the office for the influx of fresh outside air and a need for the straight line installation of steam-jacket and frying kettles on the sides of windows. This study can be useful as the guidelines for estimating the investment cost of the facility and placing the placement of functional areas and equipment in the renovation of the facility. It can be also useful data for a methodology of foodservice facility design.

A Study on The Arangemnent Type and The Improvement of Collective Facility Areas in National Park (국립공원 집단시설지구 배치유형 및 개선방안에 관한 연구)

  • 장광은;임승빈
    • Proceedings of the Korean Society of Rural Planning Conference
    • /
    • 1998.10a
    • /
    • pp.31-33
    • /
    • 1998
  • The purpose of this study is to suggest the arrangement type and the improvement of the Collective Facility Areas in Korean National Park. The process of this study consists of 3-steps. The first step is to analyze spatial patterns of each Collective Facility Area and categorize Collective Facility Areas into 3 types. In the second step, the critical issues are found in landscape management of Collective Facility Areas. Thirdly the alternative design of each case which can be applicable to the planning of the Collective facility Area is suggested.

  • PDF

Tree Structure Modeling and Genetic Algorithm-based Approach to Unequal-area Facility Layout Problem

  • Honiden, Terushige
    • Industrial Engineering and Management Systems
    • /
    • v.3 no.2
    • /
    • pp.123-128
    • /
    • 2004
  • A tree structure model has been proposed for representing the unequal-area facility layout. Each facility has a different rectangular shape specified by its area and aspect ratio. In this layout problem, based on the assumption that the shop floor has enough space for laying out the facilities, no constraint is considered for a shop floor. Objectives are minimizing total part movement between facilities and total rectangular layout area where all facilities and dead spaces are enclosed. Using the genetic code corresponding to two kinds of information, facility sequence and branching positions in the tree structure model, a genetic algorithm has been applied for finding non-dominated solutions in the two-objective layout problem. We use three kinds of crossover (PMX, OX, CX) for the former part of the chromosome and one-point crossover for the latter part. Two kinds of layout problems have been tested by the proposed method. The results demonstrate that the presented algorithm is able to find good solutions in enough short time.

A Study on the Size Computation of Seogwipo Cruise Terminal CIQ Facilities (서귀포 크루즈터미널 CIQ시설 규모산정에 관한 연구)

  • Park, Chung-Keun
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.17 no.3
    • /
    • pp.27-36
    • /
    • 2015
  • This research studies the adequate size standard of Seogwipo cruise terminal CIQ facility that is scheduled to be built around Gangjeong harbor area in Seogwipo-city. In order to respond to the highly increasing number of passenger cruise ships compared to Seogwipo cruise terminal design in 2010, the adequate size standard of Seogwipo cruise terminal CIQ facility was examined for passenger service level grade. Based on size computation elements such as the number of passengers of cruise ships with the largest size of port entry, ship landing rate, passenger processing ratio, and surge factor, the CIQ facility size for each service level grade was reviewed. As a result, the area of 2,971m2 (A grade), 2,409 m2 (B grade), and 2,088 m2 (C grade) were computed. This showed that the area of B grade was about 82% and C grade 70% compared to the area of A grade. The CIQ facility size computed for each service level grade in this research was analyzed that its area needed to be increased by 322% at least and 458% at most, compared to the CIQ facility area of 649m2 of the existing design (2010). In order to respond to the increasing number of cruise passengers, provide high-level passenger service, and improve the international image of Jeju, Seogwipo cruise terminal should secure the size that is equal to or higher than the B grade of service level.

Quality Improvement and Application increase of Framework Data in the Facility Area (시설물분야 기본지리정보 품질 향상 및 활용 증대 방안)

  • Ru Ji-Ho;Heo Min;Lee Hyun-Jik
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.24 no.1
    • /
    • pp.79-88
    • /
    • 2006
  • The facility area occupies approximately 50% of the topographic landmarks playing an important role in the utilization of geographical information in various fields, and requires more up-to-date information than the framework data of other areas. However, the expression mode in the 1:5000 digital map, which is a primitive data used for the preparation of framework data in the facility area, limits the description of the information on buildings, and its revision/renewal term of 5 years makes it far from up-to-date or accurate. Therefore, this study aimed to analyze the problems and quality deteriorating factors that may occur in establishing the framework data on the basis of existing establishment process of them in the facility area, and improve the qualify of the framework data in facility area by upgrading the methods of quality improvement. Expanding the information on attributes and improving the accuracy of locations were proposed as ways to increase the degree of utilization of the framework data in the facility area. And as the methods of expanding the information on attributes, it was proposed to improve the accuracy of the information on attributes for the framework data in the facility area using the information on attributes in the 1:1000 scale maps, and also to diversify the information on attributes in connection with the LMIS and AIS. To improve the accuracy of the locations, analyses were made with the potential problems that may occur in the establishment process through an experiment on the framework data in the facility area based on 1:1,000 digital map, and the results were used to present an improved, optimum process.

A Comparison Analysis on the Facility Standards and Campus Sizes of the National Universities in Korea and Japan (한·일 국립대학 시설 기준 및 캠퍼스 면적 비교·분석)

  • Choi, Hyeong Ju
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.18 no.3
    • /
    • pp.1-15
    • /
    • 2019
  • This study analyzes universities in Japan, which haves many similarities with those in Korea in certain aspects of the educational system and a common problem of reduced university admission resources, Korea's national university facility standards, policy related to nation-level university facility, and practical campus case. Through this, the study aims to examine the difference in the national approach and basic philosophy about university facilities in Korea and Japan, and also identify the major planning factors and improvement directions when establishing plans for university campuses in the future. The results of this study are as follows. First, Korea tends to promote policies related to university facilities by individual projects centered on a major pending problem or issue, while Japan has been shown to promote national university facility policies under a comprehensive mid-to-long-term plan by establishing a maintenance plan aimed at national university facilities every five years. Second, In the case of the university facility areas, the average university facility area of the examined universities in Japan is about 5.6% larger than the average university facility area in Korea. Additionally, the university facility area per student in Japan is about 13% wider than that of Korea. The total floor area of university facilities in Japan is also about 20.7% larger than that of Korea, and the university facility area per student in Japan is about 56.7% wider than that of Korea as well. Among support facilities, the total floor area of dormitories in Korea was 2.5 times wider than that of Japan, however, the acceptance rate of dormitory in Korea was 5.6% higher than Japan. Third, the university facility criteria items and systems of two countries are similar. but there are slight differences in the content such as the method of calculating student capacity, division classification, and the method of calculating the number of teachers.

Application of the GIS in the Hydrologic Effects Caused by the Second Collective Facility Area Development in Mt. Kyeryong National Park (GIS를 이용한 계룡산국립공원 제2집단시설지구개발의 수문영향파악)

  • Ye, Woo-Sung;Lee, Hee-Sun;Lee, Kyoo-Seock
    • Journal of Environmental Impact Assessment
    • /
    • v.3 no.2
    • /
    • pp.57-67
    • /
    • 1994
  • The National Park should be preserved as described in the regulation. However, the development has resulted in degrading the environment in the park. Especially, the collective facility area has been developed for the commercial benefit rather than for the preservation. So, it is necessary to figure out the impact of the development plan proposed. Thus, the purpose of this study is to explore the hydrologic effects due to the collective facility area development in the National Park. The study site is the second collective facility area of Mt. Kyeryong National Park. The analysis of hydrologic effects due to the development has been carried out using the GIS in this study. The Rational Method and Soil Conservation Service(SCS) were used to estimate the runoff volume. During this procedure, GIS software, ARC/INFO was used to integrate, manipulate, and calculate the attribute value of a number of ploygons which represen each land use characteristic. A program was written to compute the attribute value of each polygon and to estimate the difference of peaktime runoff volume before and after development.

  • PDF

Improvement for Classification System of Building Use on Neighborhood Living Facility (근린생활시설 용도분류체계 개선방안 연구)

  • Lee, Sung-Ok;Hwang, Eun-Kyoung
    • Journal of architectural history
    • /
    • v.21 no.6
    • /
    • pp.53-62
    • /
    • 2012
  • The purpose of this study is to present improvement for classification system of current neighborhood living facility to correspond rapid social change and various industries after understanding its status and problem. In current Building Standard Law, various kinds of buildings are classified for their structure, purpose of use, and building types. The Neighborhood Living Facility is divided into First Neighborhood Living Facility and Second Neighborhood Living Facility with applying area standards, according to facilities of convenience degree for neighborhood inhabitants. This classification, however, has problem in an arbitrary decision and applying of buildings without any definition or standards to adopt. And, there are some mixed neighborhood public functional facilities and amusement business affecting public morals among the Neighborhood Living Facility, so hazard environmental problems are also existed. According to the improved program, the study presents a prompt adoption of new facilities according to various industry increase, with minimum public discontent over adopted area standards. This study suggests making a clear scope through reclassification of Neighborhood Living Facility within the scope of the law on current Neighborhood Living Facility and an improvement plan of introducing necessary definitions on purpose of facility.