A Study on the Estimation of Electric Equipment Capacity in Office Buildings (사무소건물(事務所建物)의 전기설비용양(電氣設備容量) 산정(算定)에 관한 연구(硏究))

  • Kim, Se-Dong;Choi, Do-Hyuk
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.666-668
    • /
    • 1992
  • This paper shows a reasonable design standard of electric equipment capacity for office buildings, that was made by the systematic and statistical way considering actual conditions, such as investigated electric equipment capacity, electric power consumption, etc for 121 buildings. The saving of electric equiment investment, the decrease of power loss, the improvement of facilities utilization and the decreasse of electric power rates can be contributed by the application of the design standard.

  • PDF

A Study on the Eco-friendly Properties of Apartment Housing Playground in Germany (독일 공동주택 놀이터의 친환경적 특성 연구)

  • Kim, Ja Kyung
    • Korean Institute of Interior Design Journal
    • /
    • v.24 no.5
    • /
    • pp.87-98
    • /
    • 2015
  • As an apartment house as well as improving quality of life is becoming one of the brands, it is increasing the importance of the outer space with the facilities in the housing complex. In particular, the outdoor playground such as the community facilities that children and adults share as the activity areas for residents has received attention. However, actually children have not used many of Korean apartment housing playgrounds that were installed formally in the scrap area according to the housing plan by residential construction standards. it is considered necessary to improve the quality of the playground in housing complex and reform it in order to make the eco-friendly play space in which children can play safely and h healthily. As an alternative, we analyzed the eco-friendly properties of the playgrounds installed in the eco-friendly housing complex in Germany and derived the main planning elements of eco-friendly playground. In the observational survey of the 10 playgrounds in 9 housing complexes in 5 regions in Germany, we evaluated the environment-friendliness of these playgrounds in the 8 fields(location and placement, ecological environment, play space, play equipment and facilities, additional facilities, materials and resources, energy saving, environmental load reduction) according to the levels(suitable, partial reflection, unsuitable, non-reflection) of reflection of eco-friendly planning factors. The following is the summary of the results about the reflection of eco-friendly planning factors. In terms of "suitable": location and placement(88.8%), play equipment and facilities(73.5%), additional facilities(60.6%), environmental load reduction(54%), and ecological environment(50%) were higher than others. In terms of "unsuitable": there was nothing. In terms of "non-reflection": energy saving(95%), additional facilities(32.2%), and materials and resources(30.9%) were in order. Therefore, on the basis of these results, this study proposed the planning indicators to be considered first and the planning factors that should be complemented and improved in the construction of apartment housing playground in future.

Nonchange of Grounding Current due to Equipment Measuring Insulation Resistance (절연저항 측정 장치에 의한 지락사고 전류의 비변화)

  • Um, Kee-Hong;Lee, Kwan-Woo
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.3
    • /
    • pp.175-180
    • /
    • 2015
  • With progress in industrialization, facilities for generating, delivering, and receiving high levels of electric power are in great demand. The scale of electric power equipment is increasing in both size and complexity. This has contributed to the development of our modern, high-tech and information-based society. However, if the generation of electric power is suspended due to unexpected accidents at power facilities or power stations, a range of equipment the operations of which are dependent on electric power can be damaged, causing substantial socioeconomic losses in an industrial society. A great deal of time and money would be expended to repair damaged facilities at a power station, causing enormous economic loss.In order to detect the deterioration processes of power cables, and to prevent the destruction of power cables, the operation status of power cables should be monitored on a regular basis. We have installed equipment at Korea Western Power Co., Ltd., located in Taean, in order to predict and prevent the destruction of power cables. This is an entirely new installation: a set of equipment invented specifically to measure the insulation resistance of power cables. Installation of the equipment does not cause the flow of earth fault current. This ensures accurate measurement of insulation resistance values by the equipment. We have been studying this equipment in order to develop preventive technology that would show the deterioration processes of power cables.

Policy Suggestions for Korean Research Equipment Industry According to the State of Construction of National Research Facility and Equipment by Country of Manufacture : Focusing on Basic and Analytical Science Field (제조국가별 국가연구시설장비 구축 현황에 따른 국산연구장비 산업 활성화 정책 제언: 기초·분석과학 분야 중심으로)

  • Kim, Chang-Yong;Chung, Taewon;Kong, Jaehyun;Seo, In-Su;Park, Chan-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.5
    • /
    • pp.322-333
    • /
    • 2019
  • The purpose of the current study was to investigate the level of market size and market share of domestic research equipments for analyzing the difference of the number and amount of construction by the manufacturing countries in the basic and analytical science fields based on the information of the research equipment invested by the Korean government for the past 14 years. As of January 1 2019, from 2005 to 2018, 20,687 research facilities & equipments (main equipment with a construction cost of 30 million won or more) built in the basic and analytical science fields were selected for this study and their components, standard classification, number of construction, and amount of construction by country of manufacture were analyzed. Differences of the number and amount of construction among manufacturing countries were tested using a single sample chi-square test and one-way analysis of variance, followed by Bonferroni's post-hoc test. As a result of this study, the number of construction (p<.001) and construction amount (p<.05) were statistically different for each manufacturing country. The level of market size and market share was significantly different according to the equipment standard classification (p<.05). Therefore, differentiated strategies of the government and policy research projects will be required for each type of equipment and amount in order to support the policy for the localization of research equipment.

A Study on the Lift Pier and Equipment of Design Criteria for Effective Vessel Management in the Marina (마리나 항만의 효율적인 선박 관리를 위한 상하가 시설 및 장비의 설계기준에 관한 연구)

  • Moon, Jung-Hwan
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.24 no.6
    • /
    • pp.654-661
    • /
    • 2018
  • This paper analyzes the type of facilities and equipment of the marina port and analyzes its lift facilities (lift pier) and equipment (marine mobile lift). It set up the lift facilities and equipment standards. Depending on the gross tonnage of vessels in operation in Korea, the required inner width of lift piers is 5.50 m for 35-ton vessels, and 6.20 m for 50-ton vessels. The inside width of the marine mobile lift is 6.10 m for 35-ton vessels, and 6.80 m for 50-ton vessels. There are two places where the target ship can be lifted from the lift pier installed on the domestic marina, and other marinas' lift piers inner widths are insufficient by about 0.35 ~ 0.50 m. Among the marine mobile lifts in operation, there were two apparatuses that secured the inside width necessary to lift the target vessel. Other marine mobile lifts' inner widths are insufficient by about 0.3 ~ 0.6 m.

An Empirical Study on the Strategies for the Container Terminal in Pusan (부산항 컨테이너터미널의 경쟁력 제고를 위한 전략에 관한 실증연구)

  • 권능중;김성규;안기명
    • Journal of Korean Port Research
    • /
    • v.13 no.2
    • /
    • pp.245-254
    • /
    • 1999
  • This paper aims to derive the strategies for the container terminal in Pusan. So it has focused on analyzing the current conditions of Pusan container terminal while evaluating the difficulties arising from the existing facilities/equipment and the operating system in the Pusan Korea Container Terminal through the workers at the container terminal and at off-dock CY. The object of this study is to assist the existing terminals to operate the facilities/equipment reasonably and to contribute shaping the ports policy which will be the basis of constructing new ports that will remain competitive while maintaining superiority over the ports in northeast area. According to the analysis 68% of the supplier answered that their terminal services which are the most important factor in running a terminal were superior to the other while only 28% of the user answered that they thought the current services were superior. For the areas of supplementing the terminal the people working at the terminal answered in the order of business operation equipment the number of berth service and management ability while the user answered in the order of service computer system transportation system and equipment. According to the regression analysis it became clear that there should be more effort toward improving or supplementing the facility scale facility usage charge transportation facilities which will assist in developing competitiveness of the terminal. It was also noted that management ability and business ability were mentioned as the important factors in operating a terminal.

  • PDF

Development of Message Broker-Based Real-Time Control Method for Road Traffic Safety Facilities Equipment and Devices Integrated Management System

  • JeongHo Kho;Eum Han
    • Journal of the Korea Society of Computer and Information
    • /
    • v.29 no.1
    • /
    • pp.195-209
    • /
    • 2024
  • The current road traffic signal controller developed in the 1990s has limitations in flexibility and scalability due to power supply problems, various communication methods, and hierarchical black box structures for various equipment and devices installed to improve traffic safety for road users and autonomous cooperative driving. In this paper, we designed a road traffic safety facilities equipment and devices integrated management system that can cope with the rapidly changing future traffic environment by solving the using direct current(DC) and power supply problem through the power over ethernet(PoE) technology and centralized data-driven control through message broker technology. In addition, a data-driven real-time control method for road traffic safety facilities equipment and devices operating based on time series data was implemented and verified.

A Study of Efficient Floor Planning and Facility Improvement for Physical Therapy Room of Domestic Long-term Hospitals (국내 요양병원의 물리치료실의 효율적 평면계획 및 시설개선에 관한 연구)

  • Chung, Kwang-Ho
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.11 no.4
    • /
    • pp.5-11
    • /
    • 2011
  • The present study investigated the actual conditions of physical therapy rooms at long-term hospitals in Korea and conducted a comparative analysis to develop an efficient floor plan and facility improvement measures. 1. At hospitals surveyed, physical therapy services were used at a high frequency but they did not have enough space for rehab treatment and long paths of patient flow were found to make patient management inconvenient. Therefore, physical therapy units should be conveniently located both in terms of distance and direction so as to be accessible from patient rooms or wards. The space should be organized in a concentrated layout for efficiency of physical therapy, and floor planning for therapy units should ensure the best possible viewing angle to therapists. 2. With regard to the disease characteristics of patients, many physical therapy rooms were in difficult circumstances because of poor facilities, so they need to secure skilled personnel, supplement apparatuses and equipment and have rooms for functional recovery, hydrotherapy and operation treatment. In addition, each of the curtained or partitioned areas for treatment should be set up with consideration for the amount of space taken up by medical equipment. The area under each bed should be designed for patient convenience so that it can be used as storage space for patient's belongings and shoes. 3. Patients complained about the lack of physical therapy space, resting places or exercise areas and demanded the expansion of rehab programs and facilities. Physical therapy facilities need to be improved for patient privacy and effective natural ventilation. 4. At most of the long-term hospitals surveyed, physical therapy units were found to have small areas and treatment equipment and devices were insufficient compared to the number of patients. Therefore, it is required to secure more space (at least 138.24 sq. meters per 100 beds) and improve facilities for better physical therapy services.

Analysis of the School Foodservice Facilities & Sanitary Education (Seoul, Gyeonggi, Kangwon and Choongchung Areas in Korea) (학교급식 시설 현황 및 위생교육 실태 분석 - 서울, 경기, 강원, 충청지역을 중심으로 -)

  • Kim, Gyoung-Mi;Lee, Sim-Yeol
    • Korean Journal of Community Nutrition
    • /
    • v.14 no.5
    • /
    • pp.576-589
    • /
    • 2009
  • The purpose of this study was to analyze the status of school foodservice facilities, utilities and equipment & sanitary education in provinces, This study was carried out from September 2008 until December 2008 and is targeted towards schools' dietitians that work at schools with school foodservice. 1,623 schools participated in this research and Kangwondo, Choongchungdo including the metropolitan area with frequent occurrence of food bone disease were the targets of this research. The regional distribution of this research is as follows; 377 schools in Seoul, 648 schools in Gyeonggido, 160 schools in Kangwondo, 438 schools in Choongchungdo equaling 1,623 schools in total. And out of the total 1,623 schools, 815 (50.2%) were elementary schools and 808 (48.8%) were middle and high schools (p < 0.001). Most of the elementary schools, excluding 4 schools, were self-operated. In the case with middle and high schools, 81.5% (513 schools) were self-operated and 18.4% (295 schools) were contracted. When dealing with the sanitation management of school foodservice in Kangwondo and Seoul, elementary schools were less equipped with equipment and facilities than middle and high schools which proved that they were in need of improvements (p < 0.01). Schools with self-operated foodservice, in particular, were in need of preparation zone improvements. 52.3%~88.0% of stainless equipment such as utensils, spoons/chopsticks, subsidiary food tray, and food trays were sterilized by dryers. Work tables, vegetable slicers, and mincers were chemically sterilized and plastic materials were sterilized by ultraviolet rays. Data from newspapers, Internet and TV are collected beforehand and then an annual hygiene educations plan for employees are put together. Hygiene education for employees are carried out monthly through oral method.

Assessment of Food Safety Management Performance for School Food Service in the Seoul Area (서울지역 학교급식 위생관리 수행수준 평가)

  • Lee, Ji-Hyun;Goh, Yu-Kyoung;Park, Ki-Hwan;Ryu, Kyung
    • Korean Journal of Community Nutrition
    • /
    • v.12 no.3
    • /
    • pp.310-321
    • /
    • 2007
  • Effective and systematic sanitation management programs are necessary to prevent foodborne disease outbreaks in school foodservice operations. The purpose of this study was to identify the elements to improve in order to ensure the safety of school food service by evaluating sanitation management practices implemented under HACCP-based programs. The survey was designed to assess the level of hygiene practices of school food service by using an inspection checklist of food hygiene and safety. Fifty-four school foodservice establishments considered as poor sanitation practice groups from two year inspections by Seoul Metropolitan Office of Education were surveyed from September to December in 2005. Inspection checklists consisted of seven categories with 50 checkpoints; facilities and equipment management, personal hygiene, ingredient control, process control, environmental sanitation management, HACCP system and safety management. Surveyed schools scored $68.0{\pm}12.42$ points out of 100 on average. The average score (% of compliance) of each field was 10.7/20 (53.3%) for facilities and equipment management, 7.4/11 (67.2%) for personal hygiene, 7.4/11 (74.1%) for ingredient control, 22.4/32 (69.8%) for process control, 8.9/12 (73.8%) for environmental sanitation management, 4.2/7 (59.7%) for HACCP systems management, and 7.2/8 (89.7%) for safety management, respectively. The field to be improved first was the sanitation control of facilities and equipment. The elements to improve this category were unprofessional consultation for kitchen layout, improper compartment of the kitchen area, lacks of pest control, inadequate water supply, poor ventilation system, and insufficient hand-washing facilities. To elevate the overall performance level of sanitation management, prerequisite programs prior to HACCP plan implementation should be stressed on the school officials, specifically principals, for the integration of the system.