• Title/Summary/Keyword: Facilities for damage prevention

Search Result 139, Processing Time 0.021 seconds

The Way for improvement of facility to strengthen accessibility of the site for fire department (소방대의 현장접근성 강화를 위한 설비의 개선방안)

  • Oh, Taek-Hum;Sung, Ja-Man;Pak, Chan-Suk
    • Journal of the Korea Safety Management & Science
    • /
    • v.14 no.3
    • /
    • pp.67-75
    • /
    • 2012
  • Because recently(July 14, 2011) fire occurred in the engine room of a moving taxi under Namsan Tunnel 1, 51 vehicles' driver and more than 250 passengers in the road tunnel were urgently evacuated with abandoned vehicles. Vehicle fires in Namsan Tunnel that day, Sufferers struggled to escape quickly difficult to escape the two-way by abandoned vehicles on the road and to fear many casualties by using vehicle fuel and combustible interior and the driver who is ignorant of vehicle accident continuous entered in the road tunnel had accessibility the site of fire department was more difficult. In this study, It is to investigate structure and basic materials, such as fire extinguish equipment and facilities for damage prevention and to analyze the problems and to plan improvement method of fire extinguish equipment, facilities for damage prevention and transportation facilities(Large traffic signs, Breaker, etc.) on the Namsan Tunnel that in the long-term plan is prepared to strengthen for accessibility of the site of fire department in case of Vehicle's fire.

An Analysis of the Korean Peninsula Damages Vulnerabilities for a Natural Disaster Mitigation : Focus on Public Facilities Damages (자연재해저감을 위한 한반도 피해 취약성 분석 : 공공시설피해를 중심으로)

  • Park, Jong-Kil;Jung, Woo-Sik;Choi, Hyo-Jin
    • Journal of Environmental Science International
    • /
    • v.17 no.4
    • /
    • pp.413-422
    • /
    • 2008
  • This study aims to find out a state of the damages and vulnerable areas from natural disasters in the Korean peninsula using the prevention meteorological database information made by Park(2007b). Through the correlation analysis between damage elements and total property losses, we investigate the damages of public facilities, which have high correlation coefficient, and the cause of disasters and want to propose the basic information to set up the disaster prevention measures in advance. As a result, because most of the total property losses is the damages of public facilities, we can reduce the damages of natural disasters if we can predict the damages of public facilities or carry out the prevention activities in advance. The most vulnerable area for the natural disasters are Cangwon-do and Gyeongsangnam-do provinces. The vulnerable areas for the damages of public facilities by typhoon are Daegu metropolitan city, Cangwon-do, and Gyeongsangbuk-do provinces. These vulnerable areas will take place more frequently due to the climate change including Gyeongsangnam-do province so that we need to set up the disaster prevention measures and natural disaster mitigation plan. Also, we think that it has effect on reducing the damages of natural disasters to predict the damage scale and strongly perform the prevention activities in advance according to typhoon track and intensity.

A Flood Damage Preventation and Permanent Restoration Method (수해 예방과 항구적인 복구 방안)

  • 구본충
    • Journal of the Korean Professional Engineers Association
    • /
    • v.32 no.6
    • /
    • pp.94-99
    • /
    • 1999
  • Recently, flood damage is rapidly increasing because of warming of globe, urbanization and industrialization. As a countermeasure to prevent these flood damages, it is quite required to extend the flood control ability by improving the objective rivers in the watershed and building more medium to large scale reserviors. Simultaneously repairing and rehabilitation of facilities through the safety diagnosis for reinforcement of the facilities should be continuously proceeded. Also extensive implementation of drainage improvement, establishment of prevention and refairing system against flood damage and raise of accuracy of weather forecasting should be proceeded.

  • PDF

Development and Evaluation of Potential Flood Damage Index for Public Facilities (공공시설물 잠재홍수피해지수 체계 개발 및 평가)

  • Kim, Gilho;Baeck, Seung Hyub;Jung, Younghun;Kim, Kyungtak
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.58 no.4
    • /
    • pp.97-106
    • /
    • 2016
  • Since public facilities have high property values and are directly exposed to the flood hazard, they account for the highest share of disaster damages compared to other assets such as housing, industry, vehicle and agriculture in case of floods. Therefore, this study was conducted to develop and suggest the potential flood damage index for public facilities to evaluate potential flood damage of specific local government directly or indirectly as a tool for decision-making related to flood prevention, maintenance, management, and budget allocation. The flood damage assessment system proposed in this study was evaluated in 231 local governments nationwide. Evaluation results showed that higher values were obtained in Seoul metropolitan government, Gyeonggi-do (province), coastal areas in Gyeongsangnam-do (province), and Jeju island.

A Study on the Disaster Prevention Plan to minimize the School Damage in the Earthquake Disaster (학교 지진피해 최소화를 위한 방재대책 개선에 관한 연구)

  • Lee, Byoungho;Cho, Woncheol
    • Journal of Korean Society of societal Security
    • /
    • v.3 no.1
    • /
    • pp.67-73
    • /
    • 2010
  • School is a place to be done the education of Disaster Prevention and to be established the function of Disaster Prevention and seismic performance to secure the safety of children as well as emergency evacuation facilities for local communities in case of disaster. To improve the ability of Earthquake Disaster Prevention for students and teachers schools have to put the Earthquake Disaster Prevention on the subjects, for an example ethics, social study, science and gym and make a plan to efficiently manage school disaster prevention facilities. Seismic retrofitting on school facilities have to be established with the method of construction for steel bracings and seismic shear walls choosing old architectures first which is not the design with the seismic performance considering educational environmental aspects, and reconstruction of old architectures to get the agreement of societies. Furthermore, there is great demand for the effective, efficient and systematic improvement of school facilities for the use of shelters to be disaster prevention facilities.

  • PDF

Field Investigation of Debris Flow Hazard Area on the Roadside and Evaluating Efficiency of Debris barrier

  • Lee, Jong Hyun;Lee, Jung Yub;Yoon, Sang Won;Oak, Young Suk;Kim, Jae Jeong;Kim, Seung Hyun
    • The Journal of Engineering Geology
    • /
    • v.25 no.4
    • /
    • pp.439-447
    • /
    • 2015
  • In this study, specific sections vulnerable to debris flow damage were selected, and a complete enumeration survey was performed for the sections with debris flow hazards. Based on this, the characteristics of the sections with debris flow hazards and the current status of actions against debris flow were examined, and an efficient installation plan for a debris flow damage prevention method that is required in the future was suggested. The results indicated that in the Route 56 section where the residential density is relatively higher between the two model survey sections, facilities for debris flow damage reduction were insufficient compared to those in the Route 6 section which is a mountain area. It is thought that several sites require urgent preparation of a facility for debris flow damage reduction. In addition, a numerical analysis showed that for debris barriers installed as a debris flow damage prevention method, distributed installation of a number of small-scale barriers facilities within a valley part was more effective than single installation of a large-scale debris barrier at the lower part of a valley.

A Study on Development of Flood Vulnerability Evaluation Indicators for Sewage Treatment Plant (환경시설물 대상 홍수취약성 평가지표 개발에 관한 연구 - 하수처리장을 중심으로 -)

  • Roh, Jae-Deok;Han, Ji-Hee;Lee, Chang-Hee
    • Journal of Convergence for Information Technology
    • /
    • v.10 no.12
    • /
    • pp.110-118
    • /
    • 2020
  • This study developed a evaluation indicators on environmental facilities highly vulnerable to flood damage from quantitative and qualitative perspectives in order to reinforce the ability or preemptive disaster prevention. At first, this study classified the facilities into structural factor and non-structural factor. The structural factor consists of 11 indicators, the non-structural factor consists of 8 internal indicators and 6 external indicators. This study is expected to be prepared for flood damage by evaluating flood vulnerability of environmental facilities.

A Study on the Analysis of Fire Risk for each Building Usage Based on the Reliability of Operation of Fire Protection System (소방설비 작동신뢰성 기반 건축용도별 화재리스크 분석에 관한 연구)

  • Jin, Seung-hyeon;Kim, Hye-Won;Seo, Dong-Goo;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.06a
    • /
    • pp.113-114
    • /
    • 2020
  • In the design and maintenance of buildings, identifying the degree of damage in the event of a fire is an important factor in fire prevention and fire safety design. In order to predict fire damage, safety measures should be established by predicting the nature of evacuation according to fire, smoke and in-house characteristics, and the effects of the operation of fire safety facilities should also be considered, but in Korea, the risk analysis due to the operation of fire safety facilities is insufficient. Accordingly, this study uses fire statistics and sprinkler inspection data to analyze the degree of fire damage caused by the operation of sprinkler facilities in a probabilistic manner.

  • PDF

The issue point and Improvement countermeasure on Disaster prevention countermeasure of Agriculture infrastructure facilities - About disaster example by Typhoon "maemi" in Kyongsangnamdo region - (농업기반시설 재해예방대책의 문제점과 개선방안 - 태풍"매미"로 인한 경남지역 피해 사례 중심으로 -)

  • Um, Dae-Ho;Kim, Chae-Soo;Chung, Byeong-Ho;Kim, Tai-Cheol;Kim, Dae-Sik;Han, Kyung-Soo;Jun, Teak-Ki
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.91-94
    • /
    • 2003
  • In this study we propose the improvement countermeasure of disaster prevention by analyzing the damage cause and issue point from examination by Typhoon "maemi" in Kyongsangnamdo region. The main damage cause by Typhoon "maemi" in this region is the rising of water level in river and the overflowing of bank. The basic countermeasure is executing the disaster policy enforcement for the improvement of agriculture infrastructure facilities.

  • PDF

A Study on Facilities Damage Characteristics Caused by Forest Fire in Goseong-Gun (고성산불로 인한 시설물피해특성 연구)

  • Yeom, Chanho;Lee, Si-young;Park, Houngsek;Kwon, Chungeun
    • Journal of the Society of Disaster Information
    • /
    • v.15 no.4
    • /
    • pp.469-478
    • /
    • 2019
  • Purpose: In this studies we examine the facilities damage characteristics caused by forest fire. Therefore, we surveyed damaged facilities from forest fire which was occurred on Goseong-Gun on march 28 in 2019.(damaged areas was 40ha) The types of facilities uses were house, public facility, warehouse and so on. 17 facilities were destroyed. The purpose of this study was to for establishing a disaster safety village in rural areas where damage from a similar type of disaster occurs repeatedly by conducting the consciousness survey targeting at experts and disaster safety officials in a local government. Method: We surveyed meteorological factors(temperature, wind speed, wind direction, humidity) per a minute for analyzing weather condition on Goseong-Gun when forest fire was occurred, spread and extinguished. And we surveyed forest fire risk factors(a slope degree, a slope direction, a geographical feature, a distance between forest and facility, main species, the existence of crown fire ignition, the direction of facility, the main material of building) around 10 damaged facilities. Finally, we analyzed damage pattern of facilities using meteorological factor and forest fire reisk fator Result: The weather condition of Kanseonng AWS (No.517) was high temperature, arid and strong wind, when the forest fire was occurred and spread. An average wind speed was 4.1m/s and the maximum wind speed was 11.6m/s. The main direction of wind was W(225~315°). Damaged facilities were located on the steep slope area and on the mountaintop. The forest density around facilities was high and main species was korean red pine. The crown fire was occurred in the forest around damaged facilities. The average distance was 13.5m from forest to facilities. When the main matarial of building was made by fire resistance materials (for example, rainforced concrete), the damage was slightly. on the other hand, when by flammable material (for example, a Sandwich Panel), the facilities were totally destroyed Conclusion: The results of this research which were the thinning around house, making a safety distance, the improvement of main material of building and etc, will be helpful for establishing a counter measure for a forest fire prevention of facilities in wild land urban interface