• 제목/요약/키워드: Facial unit

검색결과 96건 처리시간 0.028초

Paresthesia diagnosed using cone-beam computed tomography: a case report

  • Kumar, Umesh;Kaur, Charan Kamal;Vashisht, Ruchi;Rattan, Vidya
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제20권2호
    • /
    • pp.95-99
    • /
    • 2020
  • Various dental procedures, such as injection administration, surgical treatment, and endodontic treatment, can cause injury to the nerves. The most commonly injured nerves are the inferior alveolar and lingual nerves. This can manifest as altered sensation to the area of innervation of the injured nerve, such as the lower lip, chin, teeth, tongue, and mucosa. Altered sensations or loss of sensation are relatively infrequent complications in daily dental practice. Here, we report an uncommon case of altered sensation in the midfacial region caused by an endodontic procedure and discuss the need to consider local dental causes in the differential diagnosis of numbness in the facial region.

성장기 3급 부정교합 환자에서 악안면 형태에 대한 측모두부계측방사선학적 연구 (A Lateral Cephalometric Study of Maxillofacial Morphologic Features in Class III Malocclusion Children)

  • 손우일;장익준;송재철;진병로
    • Journal of Yeungnam Medical Science
    • /
    • 제18권2호
    • /
    • pp.208-214
    • /
    • 2001
  • 성장기 3급 부정 교합인 남아 20명의 두부계측방사선 사진을 Harvold 분석법을 중심으로 하여 정상 대조군과 비교하여 다음과 같은 결론을 얻었다. 상하악간 상대적인 길이 차를 나타내는 악간 길이 차는 3급 부정교합자군에서 유의하게 더 크게 나타났다(p<0.05). 전하안면 고경은 3급 부정교합군에서 정상교합군보다 더 크게 나타났으나, 통계적으로 유의한 차는 없었다.

  • PDF

얼굴 표정 데이터의 최적의 가시화를 위한 선형 및 비선형 투영 기법의 비교 분석 (Comparative Analysis of Linear and Nonlinear Projection Techniques for the Best Visualization of Facial Expression Data)

  • 김성호
    • 한국콘텐츠학회논문지
    • /
    • 제9권9호
    • /
    • pp.97-104
    • /
    • 2009
  • 본 논문은 고차원 얼굴 모션 캡처 데이터를 선형 및 비선형 투영 기법에 각각 적용하고, 이를 2차원 평면으로 투영하기 위한 최적의 방법론에 대한 것이다. 본 방법의 핵심 요소는 프레임 단위의 고차원 얼굴 표정 데이터를 선형 투영 기법인 PCA와 비선형 투영 기법인 Isomap, MDS, CCA, Sammon's Mapping, LLE 등에 적용하고 이를 저차원 공간에 분포시키는 방법론 및 그 결과를 비교 분석하는 것이다. 이를 위해서는 먼저 기존의 고차원 얼굴 표정 프레임 데이터들 사이의 거리를 구하고, 선형 및 비선형 투영 기법들을 적용한 상태에서 기존의 데이터들 사이의 거리 관계를 유지하면서 저차원인 2차원 평면 공간에 분포시키는 것이다. 그리고 2차원 공간에 분포된 얼굴 표정 데이터가 원형 데이터와 비교 했을 때, 최적의 상태로 프레임 데이터들 사이의 거리 관계를 유지하고 있는 투영 기법을 찾는다. 결국 본 논문에서는 고차원 얼굴 표정 데이터를 저차원 공간에 투영하기 위한 선형 및 비선형 투영 기법들을 비교 분석하고, 각각에서 최적의 투영 기법을 찾아낸다.

임상가를 위한 특집 1 - 성장기 아동에서 상하악 폭경 부조화와 하악과두의 비대칭 성장과의 관계 (The relationship between the transverse discrepancy of the jaws and asymmetric growth of the condyles in children)

  • 이지나
    • 대한치과의사협회지
    • /
    • 제51권6호
    • /
    • pp.302-312
    • /
    • 2013
  • It has been established that disk displacement of the temporomandibular joint(TMJ) can cause mandibular asymmetry in growing subjects. One of the causes of internal derangement of TMJ seems to be the result of poor positioning of the joint structure in unilateral cross bite, and the subsequent occlusal trauma transferred to the functioning unit of the mandible, the joint and disc. Transverse discrepancy of the maxillary and the mandibular posterior dentoalveolar units was often found in mandibular asymmetric subjects. Most of the asymmetry in growing subjects becomes worse with further growth if left untreated. However once sufficient posterior overjet is gained through orthodontic treatment, many cases have shown improvement in facial asymmetry. Furthermore, the position of condyles in computed tomogram(con-beam CT) changed from anatomically unfavorable position to more concentric position.

효율적인 수화 통신을 위한 코믹한 감정 표현 (Comic Emotional Expression for Effective Sign-Language Communications)

  • 고광훈;김상훈
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1999년도 하계종합학술대회 논문집
    • /
    • pp.651-654
    • /
    • 1999
  • In this paper we propose an emotional expression method using a comic model and special marks for effective sign-language communications. Until now we have investigated to produce more realistic facial and emotional expression. When representing only emotional expression, however, a comic expression could be better than the real picture of a face. The comic face is a comic-style expression model in which almost components except the necessary parts like eyebrows, eyes, nose and mouth are discarded. In the comic model, we can use some special marks for the purpose of emphasizing various emotions. We represent emotional expression using Action Units(AU) of Facial Action Coding System(FACS) and define Special Unit(SU) for emphasizing the emotions. Experimental results show a possibility that the proposed method could be used efficiently for sign-language image communications.

  • PDF

A STUDY ON THE MARGINAL FIT OF COLLARLESS METAL CERAMIC FIXED PARTIAL DENTURES

  • Yoon Jong-Wook;Yang Jae-Ho;Han Jung-Seok;Lee Jae-Bong
    • 대한치과보철학회지
    • /
    • 제43권6호
    • /
    • pp.707-716
    • /
    • 2005
  • Statement of problem. Collarless metal ceramic fixed partial dentures(FPDs) had an esthetic problem such as opaque reflection in cervical region. To overcome this, modified coping which removed its facial cervical metal could be used. The marginal quality could be worsen according to the amount of its facial metal reduction. Purpose. The purpose of this study was to evaluate marginal fits of collarless metal ceramic FPDs with retainers of modified copings. Material and method. Dentoform maxillary left central incisor and right lateral incisor were prepared for 3-unit collarless metal ceramic FPD and fixed in yellow stone. This model was duplicated to PBT resin dies via CAD/CAM and injection molding. Four different facial margin design groups were investigated. Group A was a coping with a thin facial metal collar, group B was a collarless coping with its facial metal to the shoulder, group C was a collarless coping with its facial metal 1 mm short of the shoulder, and group D was a collarless coping with its facial metal 2 mm short of the shoulder. Seven collarless metal ceramic FPDs per group were fabricated. They were cemented to PBT resin dies with resin cement. After removal of pontics, each retainers were separated and observed under Accura 2000 optical microscope. Then, retainers were embeded in orthodontic resin and cross sectioned faciopalatally. Internal marginal fits of midfacial porcelain margins were observed under FE-SEM. Result and conclusion. Within the limitations of this in vitro study. The following conclusions were drawn. 1. Mean marginal gaps of collarless FPDs were in the $50-60{\mu}m$ range. 2. In midfacial margin, marginal discrepancies were greater in group A than in the experimental groups(p<0.05). 3. In midpalatal margin, marginal gaps were greater in group C and D than in group A and B(p<0.05). 4. Marginal fits of porcelain margins were better than those of metal margins in collarless metal ceramic FPDs. 5. In both teeth, internal marginal gaps of group C and D were greater than those of group A and B(p<0.05).

안와골절 정복술에 사용된 인공삽입물의 전산화단층촬영 추적관찰 (CT Observation of Alloplastic Materials Used in Blow Out Fracture)

  • 이원;강동희
    • Archives of Plastic Surgery
    • /
    • 제37권4호
    • /
    • pp.380-384
    • /
    • 2010
  • Purpose: Distinguishing different types of implants and assessing the position and size of implants by radiologic exam after orbital wall reconstruction is important in determining the surgery outcome and forecasting prognosis. We observed time-dependent density changes in three types of implants (porous polyethylene, resorbing plate and titanium mesh plate) by performing facial bone CT after orbital wall reconstructions. Methods: A total of 32 patients, who had underwent orbital wall fracture surgery from October 2006 to March 2009 and received facial bone CT as outpatients at 1 postoperative year were included in the study. Follow-up facial bone CT was performed on the patients pre- operatively, 1 month post-operatively, and 1 year post-operatively to observe the status of the orbital implants. Medpor $^{(R)}$ (Porex Surgical, Inc., Newnan, Ga.) was used as porous polyethylene and followed-up in 14 cases; for resorbing plate, Synthes mesh plate (Synthes, Oberdorf, Switzerland) was used in the reconstruction, and followed-up in 11 cases; and titanium mesh plate usage was followed-up in 7 cases. Computed tomographic scan (CT) and water's view were done for radiography, and hounsfield unit (HU) was used to compare density of those facial bone CT. Wilcoxon signed rank test was applied to statistically verify measurement difference in each group of hounsfield units. Results: Facial bone CT examination performed in 1 month post-operative showed that the density of porous polyethylene, resorbing plate and titanium mesh plate were -42.07, 105.67 and 539.48 on average, respectively. Among the three types of implants, titanium mesh plate showed the highest density due to its radiopaque feature. Following up the density of three types of implants in CT during 1 year after the orbital wall fracture surgery, the density of porous polyethylene increased in 10.52 House Field Units and the resorbing plate was decreased in 26.87 HouseField Units. There were no significant differences between densities in 1 month post-operatively and 1 year post-operatively in each group ($p{\geq}0.05$). Conclusion: We performed facial bone CT on patients with orbital fractures during follow-up period, distinguishing the types of implants by the different concentration of implant density, and the densities showed little change even at 1 year post-operative. To observe how implant densities change in facial bone CT, further studies with longer follow-up periods should be carried out.

Surgical Treatment of Dermatomal Capillary Malformations in the Adult Face

  • Kim, Yoo-Jeong;Oh, Suk-Joon;Lee, Jun-Sang;Yang, Ji-Hoon;Koh, Sung-Hoon;Jung, Sung-Won
    • Archives of Plastic Surgery
    • /
    • 제39권2호
    • /
    • pp.126-129
    • /
    • 2012
  • Background : Facial capillary malformations (CMs) rarely recede; they often become darker and raised in proportion to their growth. These malformations may hypertrophy in adulthood, resulting in increased disfigurement and dysfunction. Laser treatment is considered a first-line therapy for focal CMs, but thick wide lesions, which are accompanied by hypertrophy and have a well-circumscribed nodularity, may be treated with surgical excision and reconstruction. Methods : We retrospectively reviewed the records of 25 consecutive patients who had undergone complete or partial excisions of facial capillary malformations in our unit. After the excisions, the defects that encompassed their facial aesthetic units were subsequently covered by various methods, including primary closures, local flaps, expanded flaps, split-thickness skin grafts, and full thickness skin grafts. Results : The data demonstrated satisfactory results and reliability. Our patients were treated without significant complications, and all of the patients were moderately or fully satisfied with the outcome of their surgeries. Conclusions : Among the many reconstructive options for adult patients with facial capillary malformations, thick split-thickness skin grafts can be a good choice for the coverage of widely excised wounds.

3급 부정교합의 초기치료 (Early Treatment of Class III Malocclusion)

  • 김가영;김진영;김병섭
    • 대한심미치과학회지
    • /
    • 제10권1호
    • /
    • pp.8-15
    • /
    • 2001
  • The Class III malocclusion classified in two types of Skeletal Class III and Pseudo Class III. In the case of the maxillary deficiency, the protraction H-G(facemask) with Bonded RPE can be used. For children with A-P and vertical maxillary deficiency, the preferred treatment is to move the maxilla into a more anterior and inferior position, which also increases its size as bone is added at the posterior and superior sutures. Successful forward repositioning of the maxilla can be accomplished before age 8. To resist tooth movement as much as possible, the maxillary teeth should be splinted together as a single unit. The maxillary appliance must have hooks for attachment to the facemask that are located in the canine-primary molar area above the occlusal plane. The facemask usually worn until a positive overjet of 2-5mm is achieved interincisally. Occipital chin cup is successful in those patients who can bring their incisors close to an edge-to-edge position when in centric relation. This treatment is particularly useful in patients who begin treatment with a short lower anterior facial height, as this type of treatment can lead to an increase in lower anterior facial height. If the pull of the chin cup is directed below the condyle, the force of the appliance may lead to a downward and backward rotation of the mandible.

  • PDF

Hemifacial Transplantation Model in Rats

  • Lim, Jong Woo;Eun, Seok Chan
    • 대한두개안면성형외과학회지
    • /
    • 제15권2호
    • /
    • pp.89-93
    • /
    • 2014
  • Background: To refine facial transplantation techniques and achieve sound results, it is essential to develop a suitable animal model. Rat is a small animal and has many advantages over other animals that have been used as transplantation models. The purpose of this study was to describe a rat hemifacial transplantation model and to verify its convenience and reproducibility. Methods: Animals used in this study were Lewis rats (recipients) and Lewis-Brown Norway rats (donors). Nine transplantations were performed, requiring 18 animals. The hemifacial flap that included the ipsilateral ear was harvested based on the unilateral common carotid artery and external jugular vein and was transferred as a single unit. Cyclosporine A therapy was initiated 24 hours after transplantation and lasted for 2 weeks. Signs of rejection responses were evaluated daily. Results: The mean transplantation time was 1 hour 20 minutes. The anatomy of common carotid artery and external jugular vein was consistent, and the vessel size was appropriate for anastomosis. Six of nine allografts remained good viable without vascular problems at the conclusion of study (postoperative 2 weeks). Conclusion: The rat hemifacial transplantation model is suitable as a standard transplantation training model.