• Title/Summary/Keyword: Fabry-Perot sensor

Search Result 95, Processing Time 0.023 seconds

Sound Detection Characteristics Using Fabry-Perot Fiber Optic Sensor which Simply Supported in Structure (양단이 지지된 Fabry-Perot 광섬유센서의 음압 감지 특성 연구)

  • 이종길;이진우;이준호
    • The Journal of the Acoustical Society of Korea
    • /
    • v.22 no.7
    • /
    • pp.585-591
    • /
    • 2003
  • In this paper, fiber optic sensor using Fabry-Perot interferometer which had benefit of minimize and light-weight was used. The sensor head has 1cm in length, total length of fiber is 9.5 chi and the sensor supported at both ends, simply. To analyze the acoustic characteristic non-directional speaker is used as a sound source. Acoustic applied in lateral direction and detected two signals were compared each other. Below 1㎑ fiber optic sensor has more sensitive than microphone, but in 2㎑ fiber optic sensor has less sensitive than microphone. This characteristic varies to the supporting system of fiber optic sensor. It was confirmed that the Fabry-Perot interferometric sensor detected acoustic signal, effectively. This kind of sensor can be applied to the structural health monitoring field of intellectual structure.

Sound Measurements of the Discharge Break Down Using Fabry-Perot Sensor Array (Fabry-Perot형 광섬유 배열센서의 방전 음압 계측)

  • Lee, Jong-Kil;Lee, June-Ho;Lee, Jin-Woo
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.770-773
    • /
    • 2003
  • To measure discharge breakdown acoustic signal, Fabry-Perot interferometer fiber optic sensor is used. Fiber optic sensor array can measure the partial discharge acoustic signal caused by defect of power facilities such as power cables, transformers and gas insulation. Fabry-Perot interferometer is selected as an fiber optic sensor array. It is shown that Fabry-Perot fiber optic sensor array detected discharge breakdown acoustic signal, effectively.

  • PDF

Fiber Fabry-Perot interferometric sensor for the measurement of current flowing into a small fuse (소형 퓨즈에 흐르는 전류 측정용 광섬유 패브리-페로 간섭형 센서)

  • Park, Sung-Sun;Park, Jae-Hee;Kim, Kyung-Chan
    • Journal of Sensor Science and Technology
    • /
    • v.14 no.2
    • /
    • pp.91-95
    • /
    • 2005
  • A fiber Fabry-Perot interferometric sensor for the measurement of current flowing into a small fuse have been studied. The proposed current sensor was fabricated with a fiber Fabry-Perot interferometer attached close to a fuse line inside a small fuse. The fiber Fabry-Perot interferometer used in the experiment had the 10 mm cavity length and the 3.5 % reflectance mirrors. The phase shift of the output signal of the current sensor was proportional to the square of current applied to the fuse and the sensitivity of the current sensor was 0.87 degree/$mA^{2}$. The experiment results show that this sensor can be used for measuring current flowing into the fuse.

Lateral direction acoustic detection of fiber optic sensor array using Fabry-Perot (Fabry-Perot을 이용한 두 개의 광섬유 센서배열의 횡방향 음압 감지 특성)

  • Lee, Jong-Kil
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.342-345
    • /
    • 2005
  • To detect external acoustic signal, fiber optic sensor array using Fabry-Perot interferometer which had benefit of minimize and light-weight was used. The sensor head has 1cm in length, total length of fiber is 9.5cm, and the sensor supported at both ends, simply. External sound applied in lateral direction and detected two signals were compared each other. It was confirmed that the Fabry-Perot interferometric sensor array detected acoustic signal, effectively.

  • PDF

Signal Processing System of Multi-Fiber Bragg Grating Strain Sensor using Wavelength Scanning-Locking of a Fabry-Perot (Fabry-Perot 필터의 파장 스캐닝-로킹을 이용한 다중 Fiber Bragg Grating Strain 센서의 신호처리 시스템)

  • 이성은;한대우;이호준;김기수
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.24 no.8B
    • /
    • pp.1472-1479
    • /
    • 1999
  • In this paper, e proposed and implemented multi-FBG strain sensor system which used both wavelength scanning and locking of Fabry Perot filter for improve the performance of sensor system. The resolution of the sensor system is 3 and 10 $\mu$strain for the single and multi sensor system respectively.

  • PDF

Linear Interrogation of Distributed Fiber Grating Temperature Sensor Network using a Fabry-Perot ITU Filter (Fabry-Perot ITU 필터의 기준파장을 이용한 분배형 광섬유 격자 온도센서의 선형복조)

  • Park, Hyoung-Jun;Song, Min-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.7
    • /
    • pp.54-60
    • /
    • 2007
  • We constructed a fiber-optic temperature sensor system using a sensor array with 15 fiber Bragg gratings for distributed temperature monitoring in electrical power systems. A polynomial fitting algorithm was used to compensate the nonlinear action of the MEMS tuneable wavelength filter used for Bragg wavelength demodulation Fixed passband wavelengths from a Fabry-Perot ITU filter were used as reference wavelengths for the fitting algorithm which obtained constant accuracy regardless of the wavelength scanning range and frequency. About 0.18[%] of linearity error compared to reference thermocouple thermometer has been obtained in the preliminary experimental results.

Characteristics of A Diaphragm-Type Fiber Optic Fabry-Perot Interferometric Pressure Sensor Using A Dielectric Film (유전체 박막을 이용한 다이아프램형 광섬유 Fabry-Perot 간섭계 압력센서의 특성)

  • Kim, M.G.;Yoo, Y.W.;Kwon, D.H.;Lee, J.H.;Kim, J.S.;Park, J.H.;Chai, Y.Y.;Sohn, B.K.
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.3
    • /
    • pp.147-153
    • /
    • 1998
  • The strain characteristics of a fiber optic Fabry-Perot pressure sensor with high sensitivity using a $Si_{3}N_{4}/SiO_{2}/Si_{3}N_{4}$ (N/O/N) diaphragm is experimentally investigated. A 600 nm thick N/O/N diaphragm was fabricated by silicon anisotropic etching technology in 44 wt% KOH solution. An interferometric fiber optic pressure sensor has been manufactured by using a fiber optic Fabry-Perot intereferometer and a N/O/N diaphragm. The 2 cm length fiber optic Fabry-Perot interferometers in the continuous length of single mode fiber were produced with two pieces of single mode fiber coated with $TiO_{2}$ dielectric film utilizing the fusion splicing technique. The one end of the fiber optic Fabry-Perot interferometer was bonded to a N/O/N diaphragm. and the other end was connected to an optical setup through a 3 dB coupler. For the N/O/N diaphragm sized $2{\times}2\;mm^{2}$ and $8{\times}8\;mm^{2}$, the pressure sensitivity was measured 0.11 rad/kPa and 1.57 rad/kPa, respectively, and both of the nonlinearities were less than 0.2% FS.

  • PDF

Multiplexed fabry-perot interferometric sensor system (다중화 Fabry-Perot 간섭형 광섬유 센서 시스템)

  • 나도성;예윤해;이동영;박광순
    • Korean Journal of Optics and Photonics
    • /
    • v.10 no.4
    • /
    • pp.273-278
    • /
    • 1999
  • A TDM-multiplexed fiber optic pressure/temperature sensor system utilizing fiber optic Fabry-Perot interferometers as sensing devices was developed and applied to measure water level variations and temperature variations. The maximum measurement speed of the system without saving measurement data is 4500 times per second and the response time of the sensors is thought to be ~ms. The difference between the theoretical value and the measured value for the scale factor of water level sensor and temperature sensor was +13.7%, -18% respectively. The nonlinearity of the sensors after calibration was less than 1%. The sensor system was applied to verify the capability of measuring the temperature variations and water level variations at a high speed.

  • PDF

Investigation of the Lateral Acoustic Signal Detection Using by Two Fabry-Perot Fiber Optic Sensor Array (두 개의 Fabry-Perot 광섬유 센서 배열을 이용한 횡방향 음압 감지 특성 연구)

  • Lee, Jong kil
    • 대한공업교육학회지
    • /
    • v.31 no.1
    • /
    • pp.185-199
    • /
    • 2006
  • In this paper, to detect lateral direction sound pressure fiber optic sensor using Fabry-Perot interferometeric sensor array was fabricated and experimented. This parallel sensor array composed of one light source and the light split into each sensor using directional coupler and to see the output signal the array system do not need any digital signal processor. As a lateral direction sound source arbitrary sound frequency of 100Hz, 200Hz, and 655Hz using by nondirectional speaker were applied to the array sensor which installed on $60cm{\times}60cm{\times}60cm$ latticed structure. The detected signals from the two sensors were analyzed in the time and frequency domains. It was confirmed that the suggested sensor array detected applied sound source well but there were a little amplitude differences in between the sensors. Because the sensor supported simply at both ends theoretical analysis was performed and its solution was suggested. To compare the theoretical and experimental results arbitrary sound frequency of 2kHz was applied to the sensor array. It shows that experimental results was good agreement with theoretical results.